![](/html/e6/e63b/e63b5efdafd13737e19bd3d699e5deece9df194bec1a1865303f5eb0972efe40/bg1.png)
RUSH MH 6 Wash CT
The RUSH MH 6 Wash CT is designed for key lighting applications
within the House of Worship, Performing Arts and Live Stage
environments where color temperature control of white light is critical
but also a compact and light weight design is desired for smaller
applications
The RUSH MH 6 WASH CT is a bright single-lens LED moving head
with fully premixed white color temperatures. With twelve 10W
WW/CW (warm white and cold white) LEDs and a 10° to 60°
motorized zoom, it offers full electronic dimming and variable strobe
effects controlled via DMX.
Pre mixed white light ranging from 2,700K to 7,800K
10
-60 Degree Zoom System
Compact and Lightweight Design
F E A T U R E S
T E CHNI CA L S P E CI F I CA T I O NS
Physical
Dynamic Effects
Control and Programming
Optics
2,700K to 7,800K Color Temp Range
Allows key lighting to be matched for multiple sources from Tungsten to
Metal Halide
•10-60 Degree Zoom System
Compact and lightweight design
Can be used as a Mid effect with a tight beam look to washing a
stage for key lighting applications
Ideal for applications that have limited ceiling height or weight
restrictions.
Length: 290 mm (11.4 in.)
Width: 189 mm (7.4 in.)
Height: 360 mm (14.2 in.)
Weight: 7.1 kg (15.7 lbs.)
Color temperature: 2700 K - 7800 K
Color temperature presets: 2700 K to 7800 K in ~100 K steps
Electronic dimming: 16-bit, 0 - 100%, four dimming curve options
Strobe and pulse effects: Variable speed and action, random strobe
Electronic 'shutter' effect: Instant open and blackout
Zoom: Motorized, 10 - 60°
Pan: 540°, 16-bit control
Tilt:
Control options:
DMX
DMX channels: 12
16-bit fine control: Dimming, pan and tilt
DMX address setting: Control panel with LCD display
DMX compliance: USITT DMX512/1990
Light source: 12 x 10 W CWUW LEDs
Minimum LED lifetime: 50 000 hours (to >70% luminous output)*
Zoom range: 10° - 60°
*Figure obtained under manufacturer's test conditions:
©
2015 Martin Professional
Olof Palmes Allé 18 • 8200 Aarhus N • Denmark • Phone: +45 87 40 00 00 • Fax: +45 87 40 00 10 • www.martin.com
Images contained in this brochure have been converted to CMYK and
are not necessarily representative of actual colors. Specifications are subject to change without notice
![](/html/e6/e63b/e63b5efdafd13737e19bd3d699e5deece9df194bec1a1865303f5eb0972efe40/bg2.png)
Construction
Installation
Connections
Electrical
Typical Power and Current
Thermal
Approvals
Included Items
Accessories
Related Items
Ordering Information
Housing: High-impact flame-retardant thermoplastic
Ingress protection rating: IP20
Mounting points: One quarter‐turn bracket for rigging clamp
Location: Indoor use only, must be fastened to surface or structure
Minimum distance to illuminated surfaces: 200 mm (8 in.)
Minimum distance to combustible materials: 100 mm (4 in.)
Minimum clearance around fans and vents: 100 mm (4 in.)
AC power input: Neutrik PowerCon
AC power throughput: Neutrik PowerCon
DMX data in/out: 3-pin and 5-pin locking XLR
AC power: 100-240 V nominal, 50/60 Hz
Power supply unit: Auto-ranging electronic switch mode
Fuse: T 3.15 A
Recommended Miniature Circuit Breaker*: Type D
* Per IEC 60898/UL489/CSA C22.2 No. 5:
Power consumption figures are typical, not maximum. Allow for +/-10% variation.:
120 V, 60 Hz: 1.3 A, 150 W, PF 0.99
230 V, 50 Hz: 0.7 A, 150 W, PF 0.94
Typical half-cycle RMS inrush current at 240 VAC: 11.3 A
Measurements made at nominal voltage with all LEDs at full intensity. Allow for a
deviation of +/- 10%.:
Cooling: Forced air (temperature-regulated, low noise)
Maximum ambient temperature (Ta max.): 40° C (104° F)
Minimum ambient temperature (Ta min.): 0° C (32° F)
EU safety: EN 60598-2-17 (EN605989-1), EN 62471, EN 62493
EU EMC: EN 55015, EN 55032, EN 55103-2, EN 61000-3-2, EN 61000-3-3, EN 61547
US safety: UL 1573, UL 8750
US EMC: CFR Title 47 Part 15
Canadian safety: CSA C22.2 No. 166
Australia/NZ: C-TICK N4241 / RCM
Power input cable, 6 A, 18 AWG, UL, 0.75 mm2, H05VV-F, 1.5 m (4.9 ft.), without mains
plug
Omega bracket for rigging clamp attachment
Power input cable, 14 AWG, UL, SJT, 1.5 mm2, H05VV-F, with PowerCon input
connector, 3 m (9.8 ft.): P/N 11541508
Power relay cable, 14 AWG, UL, SJT, 1.5 mm2, H05VV-F, with PowerCon connectors,
1.4 m (4.6 ft.): P/N 11541509
Power relay cable, 14 AWG, UL, SJT, 1.5 mm2, H05VV-F, with PowerCon connectors,
2.25 m (7.4 ft.): P/N 11541510
Power relay cable, 14 AWG, UL, SJT, 1.5 mm2, H05VV-F, with PowerCon connectors,
3.25 m (10.7 ft.): P/N 11541511
Neutrik PowerCon NAC3FCA power input connector, cable mount, blue: P/N 05342804
Neutrik PowerCon NAC3FCA power output connector, cable mount, light grey: P/N
05342805
DMX termination plug, 3-pin male XLR: P/N 91613017
Half-coupler clamp: P/N 91602005
G-clamp: P/N 91602003
Quick-trigger clamp: P/N 91602007
Safety cable, safe working load 50 kg: P/N 91604003
RUSH™ Software Uploader 1: P/N 91611399
RUSH™ MH 6 Wash CT in cardboard box: P/N 90280090
©
2015 Martin Professional
Olof Palmes Allé 18 • 8200 Aarhus N • Denmark • Phone: +45 87 40 00 00 • Fax: +45 87 40 00 10 • www.martin.com
Images contained in this brochure have been converted to CMYK and
are not necessarily representative of actual colors. Specifications are subject to change without notice