Martin Pro MAC Quantum Profile White Users Manual

MAC Quantum Profile™
SAFETY AND INSTALLATION MANUAL
Dimensions
502
452
462
240
642
98
All measurements are given in millimeters
© 2013-2014 Martin Professional™ ApS. Information subject to change without notice. Martin Professional and all affiliated companies disclaim liability for any injury, damage, direct or indirect loss, consequential or economic loss or any other loss occasioned by the use of, inability to use or reliance on the information contained in this document. The Martin logo, the Martin name, the Harman name and all other trademarks in this document pertaining to services or products by Martin Professional or its affiliates and subsidiaries are trademarks owned or licensed by Martin Professional or its affiliates or subsidiaries.
P/N 35000278, Rev. C
Contents
Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Packing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Physical installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
AC power. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Power input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
DMX data link . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Service and maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Tilt lock. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Cleaning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Replacing the head air filters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Servicing optical components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Lubrication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Using the fixture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Applying power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

Safety Information

WARNING!
Read the safety precautions in this section before
installing, powering, operating or servicing this
product.
The following symbols are used to identify important safety information on the product and in this document:
DANGER! Safety hazard. Risk of severe
injury or death.
Warning! The MAC Quantum Profile™ contains components that are accessible and live at high voltage while the fixture is connected to power. These components remain under tension for up to 30 minutes after power is disconnected. Only technicians who are authorized by Martin™ and who have access to the Martin™ service documentation for the MAC Quantum Profile are permitted to open the fixture.
Warning! Risk Group 2 product according to EN 62471. Do not view the light output with optical instruments or any device that may concentrate the beam.
This lighting fixture is for professional use only and must be installed by a qualified technician. It is not for household use. It presents risks of severe injury or death due to fire hazards, electric shock and falls. It produces a powerful, concentrated beam of light that can create a fire hazard or a risk of eye injury if the safety precautions below are not followed.
Read this manual. Install, operate and service the fixture only as directed in this manual, or you may create a safety hazard or cause damage that is not covered by the product warranty. Follow the safety precautions and observe all warnings in this manual, in the MAC Quantum Profile User Guide, and printed on the fixture.
The latest versions of this Safety and Installation Manual and the MAC Quantum Profile User Guide are available for download from the MAC Quantum Profile Product Support page on the Martin™ website at www.martin.com. Before you install, operate or service the MAC Quantum Profile, check the Martin™ website and make sure that you have the latest user documentation for the fixture. Document revisions are indicated at the bottom of page 2.
Respect all locally applicable laws, codes and regulations when installing, powering, operating or servicing the fixture.
If you have questions about how to operate the fixture safely, please contact your Martin™ supplier or call the Martin™ 24-hour service hotline on +45 8740 0000, or in the USA on 1-888-tech-180.
DANGER!
Hazardous voltage. Risk of lethal or severe
electric shock.
WARNING!
Fire hazard.
WARNING!
Burn hazard. Hot
surface. Do not
touch.
WARNING!
Intense light
emission.
WARNING!
Refer to user
manual.
PROTECTION FROM ELECTRIC SHOCK
• Do not remove any cover from the fixture except as described under “Service and maintenance” on page 12.
• Disconnect the fixture from AC power before servicing it and when it is not in use.
• Ensure that the fixture is electrically connected to ground (earth).
• Use only a source of AC power that complies with local building and electrical codes and has both overload and ground-fault (earth-fault) protection.
• The power input cable must be rated 20 A, hard usage type and heat-resistant to 90° C (194° F) minimum. It must have three conductors and an outer cable diameter of 5 - 15 mm (0.2 - 0.6 in.). In North
America the cable must be 12 AWG minimum conductor size, type SJT or equivalent. In the EU the cable must be 2.5 mm² minimum conductor size, type H05VV-F or equivalent.
• Before using the fixture, check that all power distribution equipment and cables are in perfect condition and rated for the current requirements of all connected devices.
• Isolate the fixture from power immediately if the power plug or any seal, cover, cable, or other component is damaged, defective, deformed, wet or showing signs of overheating. Do not reapply power until repairs have been completed.
• Use only a Neutrik PowerCon NAC3FCA cable connector to connect to the power input socket.
• Do not expose the fixture to rain or moisture.
• Refer any service operation not described in this manual or in the MAC Quantum Profile User Guide to Martin™ Service or an authorized Martin™ Service partner.
PROTECTION FROM BURNS AND FIRE
• The exterior of the fixture becomes hot. Take care when handling.
• Keep all combustible materials (e.g. fabric, wood, paper) at least 0.2 m (8 in.) away from the fixture.
• Keep flammable materials well away from the fixture.
• Ensure that there is free and unobstructed airflow around the fixture.
• Provide a minimum clearance of 0.2 m (8 in.) around fans and air vents.
• Do not illuminate surfaces within 2.0 m (6.6 ft.) of the fixture.
• Do not expose the front glass to sunlight or any other strong light source from any angle. Lenses can focus the sun's rays inside the fixture, creating a potential fire hazard.
• Do not attempt to bypass thermostatic switches or fuses.
• Do not operate the fixture if the ambient temperature (Ta) exceeds 40° C (104° F).
• Do not modify the fixture in any way not described in this manual or the product’s User Guide or install other than genuine Martin™ parts. Do not stick filters, masks or other materials onto any lens or other optical component. Use only accessories approved by Martin™ to mask or modify the light beam.
PROTECTION FROM EYE INJURY
• Do not look at LEDs with magnifiers, telescopes, binoculars or similar optical instruments that may concentrate the light output.
• Ensure that persons are not looking at the LEDs when the product lights up suddenly. This can happen when power is applied, when the product receives a DMX signal, or when certain control menu items are selected.
• To minimize the risk of eye irritation or injury, disconnect the fixture from power at all times when the fixture is not in use, and provide well-lit conditions to reduce the pupil diameter of anyone working on or near the fixture.
PROTECTION FROM INJURY
• Fasten the fixture securely to a fixed surface or structure when in use. The fixture is not portable when installed.
• Do not lift or carry the fixture alone.
• Use two evenly spaced clamps to suspend the fixture from rigging structures. Do not use only one clamp.
• When clamping the fixture to a truss or other supporting structure at any other angle than with the yoke hanging vertically downwards, use two half-coupler clamps. Do not use G-clamps, quick-trigger clamps or any other type of clamp that does not completely encircle the supporting structure when fastened.
• When suspending the fixture, ensure that the supporting structure and all hardware used can hold at least 10 times the weight of all devices suspended from them.
• If the fixture is installed in a location where it may cause injury or damage if it falls, install as described in this manual a secondary attachment such as a safety cable that is approved by an official body such as TÜV as a safety attachment for the weight that it secures. The safety cable must comply with EN 60598-2-17 Section 17.6.6 and be capable of bearing a static suspended load that is ten times the weight of the fixture and all installed accessories.
• Check that all external covers and rigging hardware are securely fastened.
• Block access below the work area and work from a stable platform whenever installing, servicing or moving the fixture.
• Allow enough clearance around the head to ensure that it cannot collide with an object or another fixture when it moves.
Safety Information 5

Introduction

Figure 1: Tilt lock
Thank you for selecting the Martin MAC Quantum Profile™. This moving-head spotlight features:
• 475 W long-life LED engine
• Independently variable 0-100% CMY color mixing
• Two rotating gobo wheels, one with 6 interchangeable rotating gobos, one with 10 static gobos
• Color wheel with 6 color filters
• Rotating three-facet prism
• Iris with pulse effects
• Motorized zoom and focus
• Full-range dimming with four dimming curve options
• Electronic shutter effect with variable speed regular and random strobe
• Backlit graphic display and battery power (mains power not required for fixture setup)
• Light weight at 22.4 kg (49.4 lbs.)
• Auto-sensing switch-mode power supply.
For the latest firmware updates, documentation, and other information about this and all Martin Professional products, please visit the Martin™ website at http://www.martin.com
Comments or suggestions regarding this document may be e-mailed to service@martin.dk or posted to: Technical Documentation, Martin Professional, Olof Palmes Allé 18, DK-8200 Aarhus N, Denmark.

Unpacking

The MAC Quantum Profile is packaged in either a cardboard box or a flightcase that is designed to protect the product during shipment.
This Safety and Installation Manual is included with the product. The MAC Quantum Profile User Guide, containing full details of setting up, controlling and monitoring the fixture, is available for download from the MAC Quantum Profile Product Support page on the Martin website at www.martin.com. If you have any difficulty locating this document, please contact your Martin supplier for assistance.

Tilt lock

Release the tilt lock before applying power to the fixture. See Figure 1. Release the tilt lock by pushing the lock in
towards the yoke (you can reapply the tilt lock by first checking that the power is off and then pushing the lock back in towards the yoke from the other side).

Packing

Important! Release the tilt lock and allow the fixture to cool before packing it in its flightcase.
The anti-shock material in the MAC Quantum Profile flightcase is designed to protect the head without the tilt lock applied. Release the tilt lock when transporting the fixture in the flightcase. Leaving the tilt lock applied may cause damage that is not covered by the product warranty.
6 MAC Quantum Profile Safety and Installation Manual

Physical installation

Figure 2: Potential sunlight damage
Figure 3: Clamp bracket positions
Warning! The MAC Quantum Profile has a powerful pan motor. The torque reaction when the head is panned suddenly can cause the base to move if the fixture is standing unsecured on a surface. Do not apply power to the MAC Quantum Profile unless the base is securely fastened to a surface or to rigging hardware.
Warning! Use 2 clamps to rig the fixture. Do not hang the fixture from only one clamp. Lock each clamp with both 1/4-turn fasteners. Fasteners are locked only when turned a full 90° clockwise.
Warning! When suspending the fixture above ground level, secure it against failure of a primary attachment using a safety cable that is approved as a safety attachment for the weight of the fixture together with mounting hardware, accessories, etc. Do not use the carrying handles for secondary attachment.
Warning! When clamping the fixture to a truss or other structure at any other angle than with the yoke hanging vertically downwards, use two clamps of half-coupler type. Do not use any type of clamp that does not completely encircle the structure when fastened.
Warning! Position or shade the head so that the front lens will not be exposed to sunlight or any other strong light source from any angle – even for a few seconds. See Figure 2. The MAC Quantum Profile’s lens can focus the sun's rays, creating a potential fire hazard and causing damage.
Important! Do not point strong light output from other fixtures at the MAC Quantum Profile, as intense illumination can damage the display.
See Figure 2. Lenses can focus sunlight and strong light, presenting a risk of fire and damage to the fixture. Shield or shade the head if necessary.
The MAC Quantum Profile can be fastened to a surface such as a stage or clamped to a truss in any orientation. Clamps must be half-coupler type (see Figure 4) or equivalent type that fully encircles the truss unless the fixture is installed with the yoke hanging vertically downwards, in which case other clamp types that are approved for the supported weight may be used.
The mounting points in the base allow omega brackets and rigging clamps to be fastened as shown in Figure 3.
Physical installation 7

Clamping the fixture on a truss

Figure 4: Martin rigging hardware
Half-coupler Omega bracket for
rigging clamp rigging clamp attachment
9
Locking quarter-
turn fasteners
SAFETY CABLE
Figure 5: Front of fixture
Figure 6: Safety cable attachment point
1. Check that all rigging hardware is undamaged and can bear at least 10 times the weight of the fixture.
Check that the structure can bear at least 10 times the weight of all installed fixtures, clamps, cables, auxiliary equipment, etc.
2. Bolt each rigging clamp securely to an omega bracket with an M12 bolt (minimum grade 8.8) and
self-locking nut.
3. See Figure 3 on page 7. Align the first
clamp and bracket with 2 mounting points in the base, and engage both the clamp bracket’s quarter-turn fasteners in corresponding sockets in the base. See Figure 4. Turn the levers on the quarter-turn fasteners a full 90° clockwise to lock. Repeat for the second clamp.
4. Block access under the work area. See
Figure 5. Note the position of the arrow marked FRONT on the base of the fixture. Working from a stable platform, hang the fixture on the truss with the arrow marked FRONT facing towards the area to be illuminated. Tighten the rigging clamps.
5. See Figure 6. Install a safety cable that is
approved as a safety attachment for the weight of the fixture by looping it through the safety attachment point (arrowed) in the bottom of the base and around a secure anchoring point so that the safety cable will catch the fixture if a primary attachment fails.
6. Check that the tilt lock is released. Check
that there are no combustible materials within 0.2 m (8 in.) or surfaces to be illuminated within 2.0 m (6.6 ft.) of the fixture, and that there are no flammable materials nearby.
7. Check that there is no possibility of heads
or yokes colliding with other fixtures.
8. Check that other lighting fixtures cannot project intense light at the MAC Quantum Profile, as intense
illumination can damage the MAC Quantum Profile’s display.
8 MAC Quantum Profile Safety and Installation Manual
SAFETY CABLE

AC power

Chuck BushingHousing Insert
Cable end
Termin als
Warning! For protection from electric shock, the fixture must be electrically connected to ground (earth). The AC mains power supply must be fitted with a fuse or circuit breaker and ground-fault (earth-fault) protection.
The MAC Quantum Profile features an auto-sensing switch-mode power supply that automatically adapts to AC power at 120-240 V (nominal), 50/60 Hz.

Power input

Important! Connect the MAC Quantum Profile directly to AC power. Do not connect it to a dimmer system; doing so may damage the fixture.
The MAC Quantum Profile requires a power input cable with a Neutrik PowerCon NAC3FCA cable connector for AC mains power input. The cable must meet the requirements listed under “Protection from electric shock” on page 4.
Martin™ can supply either a suitable 3 m (9.8 ft.) power cable with PowerCon input connector installed or the PowerCon input connector without a cable (see “Accessories” on page 24).

Installing a power input connector on a power cable

To install a Neutrik PowerCon NAC3FCA input connector on a power cable, see illustrations above and right:
1. Slide the bushing over the cable.
2. Slide the white chuck over cables with a diameter (D
(0.2 - 0.4 in.), or the black chuck over cables with a diameter of 10 ­15 mm (0.4 - 0.6 in.).
3. Prepare the end of the cable by stripping 20 mm (0.8 in.) of the
cable’s outer jacket.
4. Strip 8 mm (1/3 in.) of insulation from the end of each wire.
5. Use a small flathead screwdriver to fasten the wires into the
connector terminals in the insert as follows:
• live wire into the terminal marked L
• neutral wire into the terminal marked N
• ground (earth) wire into terminal marked .
6. Push the insert and chuck into the housing (note the raised key and
keyway to ensure correct orientation).
7. Fasten the bushing to the housing using a wrench to a torque of
2.5 Nm (1.8 lb.-ft).
) of 5 - 10 mm
a
Illustrations used by kind permission of Neutrik AG
AC power 9
Loading...
+ 19 hidden pages