OWNER'S
MODEL NN4A, NN4C, NN4D, NN5 AND NN5A MANUAL
Supplier Name: MARSHALL AIR SYSTEMS, INC.
Address: 419 Peachtree Drive South
Charlotte, NC 28217
Serial #: ____________________________
____________________________
____________________________
Date Received: ____________________________
Date Installed: ____________________________
Telephone #: 704-525-6230
Customer Service #: 800-722-3474
Fax #: 704-525-6229
Service Referral #: 800-722-3474
Local Service Name: ____________________________
Local Service #: ____________________________
(76 Ibs. for single unit)
Qty of 40
Watt Lights: 8 (4 per level) 6
Power Cord: 8 ft. 3 wire grounding type UL rating
[NN4A comes with (2) power cords]
Approvals: UL and NSF
Options: NN4A can be installed side-by-side instead of
stacked as above picture depicts. Height of non-stacked unit is
16-1/4". Each unit has a separate power cord. Optional 4" legs
also available.
These Heated Display Cabinets feature Marshall's own ThermoGlo™ heating technology. Heat radiates from
every square inch of the upper flat plate heating surfaces. This eliminates the need to clean intricate calrod,
wire and reflector assemblies. A precision microprocessor-type digital display and digital "set point " temperature
controller maintain consistent product temperature.
111019NN4 RV102199
Copyright @ 1994 Marshall Air Systems, Inc.
All Rights Reserved.
MANUFACTURER'S DESCRIPTION
MODEL NN4A, NN4C, NN4D, NN5 AND NN5A
INSTALLATION
1. Unpack unit and remove all protective paper or plastic covering from metal parts.
2. Place cabinet on stable base. Make sure cooling air inlets, next to temperature controller, are not
blocked.
3. The unit should be caulked to the counter top as required by health department codes, or the
optional 4" legs (item 31 on page 4) should be ordered.
4. Install 40 watt coated lights which were shipped loose.
5. Plug unit into an AC 120V receptacle. The 220V International version of unit is furnished with cord
only.
DAILY CHECKLIST AND CLEANING GUIDE
OPENING CHECKLIST
1. Turn on the power switch. The unit is ready to use after a 30 minute preheat period.
2. The temperature controller on the unit is factory set for 450°F (232°C). With the control "ON", the
actual temperature is displayed. The face plate of the control is either black or gray. The range of
set points available is from 400°F (204°C) to 450°F (232°C). The set point may be verified or
changed as follows:
IF BLACK: depress the set button to view the set point. To change set point, use Up/Down arrow
to select new set point while holding set button down.
IF GRAY: depress the set button and RELEASE to view set point. To change set point, push "set"
and, within three seconds, use Up/Down arrow to select new set point.
CAUTION: PRESS ONLY WITH SOFT PART OF FINGER " DO NOT PUSH WITH SHARP
OBJECT.
3. In normal operation, the digital controller will display a value of approximately 480°F (248°C) high
to 430°F (221°C) low.
CLOSING CHECKLIST
1. Turn off the unit and allow it to cool for 20 minutes.
2. Pans and wire grates should be remove d, washed in mild multi-purpose detergent, rinsed and
sanitized.
3. Clean unit and base with a damp cloth or non-abrasive cleaner.
DO NOT IMMERSE UNIT IN WATER! DO NOT USE CAUSTIC CLEANING SOLUTIONS!
4. Allow sufficient drying time before attempting to us e.
2
MODEL NN4A, NN4C, NN4D, NN5 AND NN5A
PREVENTIVE MAINTENANCE
Follow the daily schedule; there are no adjustments. The only user-replacement items are the light bulbs located
under the top cover. If these fail, do the following:
1. Unplug the unit.
2. Remove the bulb(s) by carefully unscrewing them from their sockets.
3. Replace the bulb(s) with a manufacturer's approved replacement part. (See parts list pages 4 & 5.)
4. Check air flow through unit by feeling for air draw at slots on each side of temperature controller.
TROUBLE SHOOTING CHART
Identify problem in the left column and look for probable cause and solution in right hand column. Probable
causes listed in the order they are most likely to happen. This sequence should be used to isolate the problem.
Problem Probable Cause Solution
1.No Light/No Heat Unplugged Circuit breaker is
tripped
2.No Light/With Heat Light bulbs burned out Light switch
defective
3.Temperature Controller Flashing
999
4.Temperature Controller Displays
Less Than 400°F (204°C)
5.Low Product TemperatureSet point too low Excessive air draftReset to 450°F(232°C) Move unit or
*Defective temperature controller or
sensor
*Loose sensor or defective heating unit
assembly
Plug in Reset breaker - call
electrician if tripped twice Call
Unplug unit and replace bulbs Call
Marshall Customer Service
Call Marshall Customer Service
Call Marshall Customer Service
shield draft
* NOTE: When replacing sensor, a special heat sink sealant will be present when removing failed sensor.
Applying new sealant is not required; however, be sure to utilize existing sealant when mounting new
sensor.
3
MODEL NN4A, NN4C, NN4D, NN5 AND NN5A
N/A
118771
Mirror Mounting Kit
ITEM PART # DESCRIPTION ITEM PART # DESCRIPTION
1 110833 Shelf Runner (2 Required) 18 502206Transformer 120V to 12V
2 501484 Screw #1 0 X.500" * 501958Transformer 240V to 120V
3 502064Sensor, RTD Temperature * 502168 Transformer 240V to 12V
4 111194Sensor Guard (T'Glo 20" X 14") 19 114541Temperature Controller RTD
5 111192 Joining Tab (4 Required) 20 * 132499 Temp Controller RTD (°C)
6 502108 Bushing 9/32" Dia. 21 500340 Terminal Strip 3 Pole
7 501684 Screw #10-24 X.750" 22 112925T'Glo 20" X 14"-120V
8 111024 Swing Cover Plate 111866 T'Glo 20" X 14"-220V
9 502083 Nylon Washer 23 501885 Label: CAUTION HOT (not shown)
10 111196 Heat Deflector 24 502080Strain Relief
11 501864Switch Rocker 25 111380 Door Assembly
12 501507Screw #10-24 X.500" 26 111387 Door Guide Assembly (right
13 111195 Faceplate Standoff 111388 Door Guide Assembly
14 110042Fan (left not shown)
15 501865Lamp Holder 27 111186 Cord With Plug
16 502239Bulb Tuffskin 40 Watt 28 110904 Cover-Side Panel Right
17 110912 Cover-side Panel-Left (no hole)
29111187Cover-Side Panel Right(with hole)30110826Control Front Panel315002634"Leg(1)
* These parts are for International (220V, 240V)
units only.
OPTIONAL:
N/A 119844 Side swing Doors (Pair)
N/A 503413 Kit, Temp. Control Faceplate