Market Forge 99-5704 Installation Manual

OWNER’S MANUAL
CHEESEMELTER
&
SALAMANDER
CHEESEMELTER P/N: 99-5704
SALAMANDER P/N: 99-5702
An Employee Owned Company
35 Garvey Street ● Everett ● MA ● 02149-4403 Form No. S-2550 ● 03/07 Tel: (617) 387-4100 ● Fax: (617) 387-4456 (MA) Toll Free: (866) 698-3188 ● Outside MA Fax: (800) 227-2659 Customer Service: custserv@mi.com ● Visit Us At: www.mi.com
MUST ORDER REINFORCEMENT CHANNELS IF MOUNTED TO AN OVEN OR RANGE.
FOR YOUR SAFETY
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER UNIT.
INSTRUCTIONS TO BE FOLLOWED IN THE EVEN THE USER SMELLS GAS, MUST BE POSTED IN A PROMINENT LOCATION IN THE KITCHEN AREA. THIS INFORMA­TION SHALL BE OBTAINED FROM THE LOCAL GAS SUPPLIER.
WARNING
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTE­NANCE CAN CAUSE PROPERTY DAMAGE, INJURY OR DEATH. READ THE INSTAL­LATION, OPERATING, AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT.
Installation of the equipment should be performed by qualied, certied and autho-
• rized personal who are familiar and experienced with local installation codes.
Before installation please red instructions completely and carefully.
Do not remove permanently afxed labels, warnings or plates from unit.
SHIPPING DAMAGE CLAIM PROCEDURE:
The equipment is inspected and crated by skilled personnel before leaving our factory.
The transportation company assumes full responsibility for safe delivery upon acceptance of this equipment.
If shipment arrives damaged:
Visible loss or damaged: Note on freight bill or express delivery and signed by person making delivery. File claim or damages immediately: Regardless of extent of damages. Concealed loss or damage: If damage is noticed after unpacking, notify transportation company immediately and le a “Concealed Damage Claim” with them. This should be
done within 15 days from date of delivery made to you. Retain container for inspection.
Please observe all local and national codes and ordinances.
• Installation must conform with local codes, or in the absence of local codes, the Na-
• tional Fuel Gas Code ANSI Z223.1. In Canada, installation must conform to installa-
tion codes for gas burning appliances and equipment standard CAN/CGA-B149.1 or
the Propane installation code CAN/CGA-B149.2 as applicable.
A manual gas shut off valve must be installed in the gas supply line ahead of the unit
and gas pressure regulator for safety and ease in servicing. The gas pressure regulator supplied must be installed on the unit prior to connecting
the equipment to the gas line. Failure to install a regulator could be potentially hazard­ous and will void warranty.
The unit and its individual shut off valve must be disconnected from the gas supply
piping system during any pressure testing for that system at test pressures in excess
of 1/2 PSI.
The unit must be isolated from gas supply piping system, by closing its individual
manual shut off valve during and pressure testing of the gas supply piping system at
test pressure equal to or less than 1/2 PSI.
i
TABLE OF CONTENTS
INSTALLATION
RATING PLATE .......................................................
CLEARANCES ........................................................ 1
GAS CONNECTION ................................................
MANUAL SHUT OFF VALVE .................................. 1
PRESSURE REGULATOR ..................................... 1
CONNECTIONS ......................................................
AIR SUPPLY & VENTILATION ................................
1
1
1 1
OPERATING INSTRUCTIONS
INITIAL PILOT LIGHTING ....................................... 2
LIGHTING & SHUTDOWN ......................................
MAINTENANCE
CLEANING CHEESEMELTER & SALAMANDER .... 2
SPECIFICATIONS
CHEESEMELTER ...................................................
SALAMANDER ........................................................ 3
DIMENSIONS
CHEESEMELTER ...................................................
SALAMANDER
ILLUSTRATED PARTS
CHEESEMELTER ................................................... 5
SALAMANDER
........................................................ 4
........................................................ 7
2
3
4
ii
INSTALLATION
RATING PLATE: Information on this plate in-
cludes the model, serial number, BTU/hour in-
put of the burners, operating gas pressure in inches W.C, and whether the unit is oriced for natural or propane gas. When communicating with the factory about a unit or requesting for special parts or information, rating plate data is essential for proper identication.
EQUIPMENT MUST ONLY BE CONNECTED TO THE TYPE OF GAS IDENTIFIED ON THE RATING PLATE!
CLEARANCES: The unit area must be kept
free and clear of all combustibles.
COMBUSTIBLE NONCOMBUSTIBLE
MODEL REAR SIDES REAR SIDES
CHEESEMELTER (ALL SIZES)
99-5704 4” 4” 0” 0”
SALAMANDER (ALL SIZES)
99-5702 4” 4’ 0” 0”
with unit and will have a 3/4” inlet/outlet open­ings and are adjusted at the factory for 5” W.C. (natural gas) or 10” W.C. (propane gas) de­pending on customer’s order. Failure to install the pressure regulator will void warranty. The arrow shown on the bottom of the reg­ulator body shows the gas ow direction, it
should point downstream to the unit. The red
air vent cap on the top is part of the regulator
and should not be removed.
CONNECTIONS: please check installer sup­plied intake pipes visually and or blow them with compressed air to clear any dirt particles,
threading chips or any other foreign mat­ter before installing a service line. When gas pressure is applied these particles could clog orices. All connections must be sealed with a joint compound suitable for LP gas and all
connections must be tested with a soapy wa-
ter solution before lighting any pilots.
GAS CONNECTION: The gas supply (ser­vice) line must be the same size or greater then the inlet line of the unit. Use a 3/4” NPT
inlet. Sealant on all pip joints must be resistive
or LP gas. Manifold pressure is 5.0” W.C. for natural gas or 10.0” for propane gas. Manifold size 3/4” NPT specify type of gas and eleva-
tion if over 2000 ft.
MANUAL SHUT OFF VALVE: this installer
supplied valve must be in the gas service line ahead of the unit regulator in the gas stream
and in a position accessible in the event of an
emergency.
PRESSURE REGULATOR: Commercial
cooking equipment must have a pressure reg­ulator on the incoming service for safe and ef­cient operation, since service pressure may uctuate on local demand. Regulator included
AIR SUPPLY & VENTILATION: The area in front of, around and above the unit must be
kept clear to avoid any obstruction of the ow
of combustion and ventilation air. Adequate clearance must be maintained around the unit
for easy servicing. Provision should be made for any commercial, heavy-duty cooking unit
exhaust combustion waste products to the
outside of the building. Usual practice is to
place the unit under an exhaust hood, which should be constructed in accordance to the lo-
cal codes. Strong exhaust fans in this hood or in the overall air conditioning system can produce a slight vacuum in the room and or
cause air drafts, either of which can interfere with the pilot or burner performance and could
be difcult to diagnose. Air movement should be checked during installation. Air openings of bafes may be to be provided in the room, if pilot or burner outage problem persists.
1