3500 GAS BOILER BASE
G
MODELS
3500M42MT6G - 6 pan steamer with 6 gallon kettle on 42” wide
gas boiler base
3500M42MT10G - 6 pan steamer with 10 gallon kettle on 42”
wide gas boiler base
3500M42MT12G - 6 pan steamer with 12 gallon kettle on 42”
wide gas boiler base
DESCRIPTION
Will be a Market Forge Model 3500 Gas Powered Convection Steam
Cooker. Will be integrally mounted on a cabinet base containing electrically powered steam boiler.
The 3500 will be of double-wall construction with 1” (25mm) thick insulation between cooking compartments and exterior walls, and will have
two 18 gauge stainless steel welded cooking compartments with coved
internal corners, and a 16 gauge stainless steel front panel.
Each cooking compartment on the 3500 has a positive slam action,
field-reversible door constructed of Type 304 stainless steel. Door
latches are spring loaded. The inner door gasket is a one-piece
NSF-approved silicone rubber gasket. The cooking compartment is
equipped with a door interlock (switch) that shuts off steam to the
cooking compartment when the door is opened. Factory installs units
with door opening from the right, see diagram on back. Each compartment will be equipped with a perforated steam inlet baffle positioned for
precise application of high velocity steam across the surface of food.
Gas Steamer/Kettle Combination
Controls for each compartment will include a 60-minute timer with
FOOD SERVICE EQUIPMENT
constant steam mode, an indicator light, steam inlet solenoid valve,
pressure relief valve, vacuum breaker, an automatic cold water condenser system, and a removable drip trough. Each compartment will
be independently and automatically controlled by setting the cooking
time on the 60-minute timer. At the end of cooking time, indicator light
will turn off and a continuous signal will sound. Signal is silenced by
returning the timer to the OFF position.
Stainless steel cabinet base will match other Market Forge stainless
steel equipment and enclose steam boiler. Base with stainless steel
frame will be equipped with 6” (152mm) stainless steel legs and adjustable bullet feet, reinforced stainless steel counter-top, and stainless
steel lift-off front cover and left front door.
The CSD-1 compliant steam boiler features an intermittent spark pilot
ignition and nickel plating. The steam boiler will be automatically filled
with water and brought to pressure when water and heat switches are
turned on and automatically drained under pressure when water and
heat switches are turned off. A cold water condenser will automatically
condense all exhausted steam before it is released from the cooker
and steam boiler drain. Also includes an ASSE approved backflow preventer, automatic water level control, low water cut-off, water strainer
and cathodic protector. For more boiler information see the M24GM36G spec sheet (14-0111).
The 6, 10 and 12 gallon steam jacketed kettle comes equipped with a
hot and cold faucet, sink with splash guard and a steam control valve.
STEAMER/KETTLE COMBINATION
JOB NAME: ___________________________
ITEM NO.: ____________________________
NO. REQUIRED: _______________________
3500M42MT6G
shown
CAPACITY
Each steamer compartment will accommodate the following:
(6) 12” x 20” x 1 “ deep pans
(3) 12” x 20” x 21/2 “ deep pans
(2) 12” x 20’’ x 4” deep pan
SHIPPING WEIGHT
3500M42MT6G - 825 lbs (374 kg)
3500M42MT10G - 830 lbs (376 kg)
3500M42MT12G - 835 lbs (379 kg)
OPTIONS & ACCESSORIES (at additional charge)
Pans & Covers
12” x 20” pan cover
12” x 20” x 1” solid pan
12” x 20” x 1” perforated pan
12” x 20” x 2-1/2” solid pan
12” x 20” x 2-1/2” perforated pan
12” x 20” x 4” solid pan
12” x 20” x 4” perforated pan
12” x 20” x 6” solid pan
12” x 20” x 6” perforated pan
Filter System
6” Flanged Feet
Digital Countdown Timer
Prison package, includes lockable stainless steel hinged
control cover, tamper proof screws, (4) 6” adjustable
flanged feet
Steam Take Off Kit (98 - 4463)
60” water hose kit with quick disconnect
44 Lakeside Avenue, Burlington, VT 05401 USA • Tel: (802) 658-6600 • Fax: (802) 864-0183
www.mfii.com

G
3500 GAS BOILER BASE
STEAMER/KETTLE COMBINATION
DETAILS & DIMENSIONS
SERVICE CONNECTIONS
G Gas Connection - 3/4” (19mm) N.P.T. female for
200,000 BTU boiler.
CW1 Cold Water - 3/8” (10mm) NPT for cold water to
boiler. Cold water lines will have a maximum of 50
PSI (3.5kg/cw2) and a minimum of 25 PSI (1.8 kg/
cw2) water pressure. CAUTION: FILTER SYSTEM
INSTALLATION INSTRUCTIONS MUST BE
ADHERED TO WHEN CONNECTING A FILTER
TO THIS LINE.
CW2 Cold Water - 3/8” (10mm) NPT for cold water to
condenser and kettle fill faucet. Cold water lines
will have a maximum of 50 PSI (3.5kg/cw2) and a
minimum of 25 PSI (1.8 kg/cw2) water pressure.
HW Hot Water - 3/8” (10mm) NPT female for hot water
to kettle fill faucet. Hot water line will have a maximum of 50 PSI (3.5kg/cw2) and a minimum of 25
PSI (1.8 kg/cw2) water pressure.
D Drain - Pipe full 2” (50mm) NPT to flush floor drain
capable of receiving water flowing at a maximum
rate of 5 gallons (19 liters) per minute. DO NOT
MAKE SOLID CONNECTION TO FLOOR DRAIN.
EC Electrical Connection - 120 Volts AC, 60 Hz, sin-
gle phase, and a 9 foot Power Cord/NEMA 5-15.
ST Steam Take-off - Connection for operations of
adjacent steam powered equipment. Requires
steam take-off kit (optional at extra cost).
Gas Steamer/Kettle Combination
FOOD SERVICE EQUIPMENT
OPERATION WILL BE BY
Gas fired, A.S.M.E. constructed and National Board
Registered, 15 PSI (1 kg/cm2) steam boiler rated at 200,000
BTU.
Boiler shall be equipped for operation with:
Natural Gas
LP Gas
Notes: If equipment is installed where elevation exceeds
2,000 feet (609.6 meters) above sea level, specify installation
altitude so that proper gas orifices can be provided.
The only available space to supply utilities to the gas boiler
is the 6” (152mm) space between the floor and the cabinet.
Allow 3” (76mm) space from side wall and 6” (152mm) from
rear wall if adjoining walls are combustible.
PVC & CPVC PIPE ARE NOT ACCEPTABLE MATERIALS
FOR DRAINS.
WATER SUPPLY
Good quality water feed is the responsibility of the owner. Water quality
must be within the following general guidelines.
TDS: 40-125 ppm Hardness: 35-100 ppm Chlorine: <0.2 ppm
Silica: <13 ppm Chlorides: <25 ppm
Chloramine: <0.2 ppm pH: 7.0 - 8.5
The best defense against poor water quality is a water treatment system
designed to meet your water quality conditions.
Appliance to be installed with backflow protection according to federal,
state or local codes.
DIMENSIONS ARE IN INCHES [MM]
4[102]
2.5 [64]
10.5
[267]
CW1
12.5
[318
6
6 Gallon kettle
10
10 Gallon kettle
12 Gallon kettle
12
55.25
[1403]
[1486]
[1537]
6
10
58.5
12
60.5
10.5
[267]
8.5
[216]
EC
22
[559]
8 [203]
CW2
D
CW1
EC
HW
42 [1067]
CW2
HW
ST
D
FLUE
ST
G
5 [127]
19 [483]
G
33 [838]
3 [76]
2.75 [70]
57 [1448]
28 [711]
6 [152]
PRINTED IN U. S. A.
SPEC SHEET: 14-0088 Rev C (12/15)
The manufacturer reserves the right to modify materials and specifications without notice.
44 Lakeside Avenue, Burlington, VT 05401 USA • Tel: (802) 658-6600 • Fax: (802) 864-0183