Market Forge 2A User Manual

DIRECT CONNECTED
MODEL NUMBERS: MF2A 2A
MF3A 3A MF4A 4A (MF Pre-x indicates Automatic controls)
COMPARTMENT STEAM COOKER
JOB NAME: ________________________ ITEM NO.: _________________________ NO. REQUIRED: ____________________
SIZE: 34 1/4” Wide x 30” Front-to-Back (
DESCRIPTION: Shall be a Market Forge Model ________ Direct Con-
nected Steam Cooker with solid stainless steel cooking
compartments. Cooking compartments shall have double door construction. Inner door shall be of cast aluminum
with stainless steel facing, and shall be removable for cleaning without tools. Door wheel screw shall be Acme type with replaceable bushing and all threads concealed. Compartment doors shall be self-latching, and shall open automatically approximately 15° when latch is opened.
Unit shall include:
2 compartments 3 compartments 4 compartments
Exterior nish shall be:
Polished stainless steel
Timing of cooking compartments shall be by:
Automatic controls which show a visible signal during
Manual mechanical timer for each compartment that
Each cooking compartment shall have:
Lift-out four track shelf uprights and one pull-out
Lift-out universal pan supports which shall hold (8)
870mm Wide x 762mm Front-to-Back)
cooking cycle, shut off and exhaust steam, drain con­densate from cooking compartment, and sound an
audible signal at end of cooking cycle. Audible signal shall continue to sound until manually shut off (option- al at extra cost).
sounds an audible signal at end of cooking cycle (standard).
shelf which shall hold (2) 12” x 20” x 2 1/2” pans OR
(2) 12” x 20” x 4” pans.
12” x 20” x 2 1/2” pans OR (4) 12” x 20” x 4” pans.
3A Shown
OPERATION SHALL BE BY:
Direct steam supply shall have a minimum incoming pressure of 15 PSI (1kg/cm2). Unit shall be equipped for operation at 5 PSI (.33 kg/cm2). 1 BHP required per com­partment. Cooker shall be mounted on an open stand
with hold-down feet in rear.
OPTIONAL AT EXTRA COST:
(Indicate quantity in space provided)
12” x 20” x 2 1/2” perforated stainless steel pans.12” x 20” x 2 1/2” solid stainless steel pans. 12” x 20” x 4” perforated stainless steel pans. 12” x 20” x 4” solid stainless steel pans. Extra shelves per compartment. Ball oat trap (Required). Pressure reducing valve (Required).
Pressure gauge for incoming steam (Recommended).
Automatic Timers.
SPEC SHEET: S-1340M
11/13
Compartment Steam Cooker on Legs
FOOD SERVICE EQUIPMENT
The manufacturer reserves the right to modify materials and specications without notice.
An Employee Owned Company
PRINTED IN U. S. A. 35 Garvey Street • Everett • MA • 02149
Tel: (617) 387-47100 • Toll Free: (866) 698-3188 • Fax: (617) 387-4456 • Outside MA Fax: (800) 227-2659
E-Mail: custserv@mi.com • Website: w w w . m f i i . c o m
DIRECT CONNECTED
COMPARTMENT STEAM COOKER
Direct Connected
S Steam Supply - 3/4” (19mm) NPT Shall have a
D Drain - Pipe full 1” (25mm) NPT to ush oor drain
EC Electrical Connection - 120 VAC, 60 Hz, 1/2”
DETAILS & DIMENSION
SERVICE CONNECTIONS
minimum incoming pressure of 15 PSI (1kg/cm2).
Pressure reducing valve will reduce incoming
pressure (up to 200 PSI) to required 5 PSI (0.4kg/ cm2). NOTE: STEAM SUPPLY MUST BE FOOD GRADE QUALITY.
capable of receiving water owing at a maximum
rate of 5 gallons (19 liters) per minute. DO NOT MAKE SOLID CONNECTION TO FLOOR DRAIN. INSTALL NO ELBOWS IN DRAIN LINE.
(13mm) conduit connection or equivalent. 2 Amps per compartment required for automatic controls.
Units without automatic controls do not require
electrical connection.
SPEC SHEET: S-1340M
11/13
NOTES: Allow 12” (305mm) spacing on left and 6” (152mm) spacing on right if height of adjoining wall or equipment exceeds 29” (737mm). Matching spacer cabi­nets 12” (305mm) or 6” (152mm) wide are available and may be specied.
PVC and CPVC pipe are not acceptable materials for drains.
One BHP is required per compartment.
CAUTION: Before connecting water to this unit, have water supply analyzed to make sure hardness is no greater than 2.0 grains and Ph level is within the range of 7.0 - 8.5. Water which fails to meet these standards should be treated by installation is water conditioner.
EQUIPMENT FAILURE CAUSED BY INADEQUATE WATER QUALITY IS NOT COVERED UNDER WAR­RANTY.
FOOD SERVICE EQUIPMENT
It is our policy to build equipment which is design certied by U.L., A.S.M.E., N.S.F. and C.S.A. However, a continuing program of product improvement makes
Compartment Steam Cooker on Legs
it necessary to submit new models to the agencies as they are developed and consequently not all models bear the appropriate agency labels at all times.