Model WB4001T User Guide
Tilt Wall Mount for 42” / 50” Plasma
Warning Statements
WARNING:
WARNING:
WARNING:
THE WALL STRUCTURE MUST BE CAPABLE OF SUPPORTING 160 LBS. IF NOT,
THE WALL STRUCTURE MUST BE REINFORCED. PROPER INSTALLATION
PROCEDURE BY A QUALIFIED SERVICE TECHNICIAN, AS OUTLINED IN THE
INSTALLATION INSTRUCTIONS, MUST BE ADHERED TO. FAILURE TO DO SO
COULD RESULT IN SERIOUS PERSONAL INJURY, OR EVEN DEATH.
SAFETY MEASURES MUST BE PRACTICED AT ALL TIMES DURING THE
INSTALLATION OF THIS PRODUCT. USE PROPER SAFETY GEAR AND TOOLS
FOR THE INSTALLATION PROCEDURE TO PREVENT PERSONAL INJURY.
PRIOR TO THE INSTALLATION OF THIS PRODUCT, THE INSTALLATION
INSTRUCTIONS SHOULD BE READ AND COMPLETELY UNDERSTOOD. THE
INSTALLATION INSTRUCTIONS MUST BE READ TO PREVENT PERSONAL
INJURY AND PROPERTY DAMAGE. KEEP THESE INSTALLATION INSTRUCTIONS
IN AN EASILY ACCESSIBLE LOCATION FOR FUTURE REFERENCE.
Indicates that the power plug is to be
disconnected from the power outlet.
Safety precautions must be taken at
Contact Marantz with any questions -
(630)-741-0300.
all times.
Warning and Caution statements.
Do not install on a structure that is prone to vibration, movement or chance of impact.
Failure to do so could result in damage to the flat panel display and/or damage to the
mounting surface.
Do not install near heater, fireplace, direct sunlight, air conditioning or any other source of
direct heat energy. Failure to do so may result in damage to the flat panel display and could
increase the risk of fire.
At least two qualified people should perform the installation procedure. Injury and/or
damage can result from dropping or mishandling the flat panel display.
1.0 PARTS LIST ..............................................................................................................................................- 4 -
PROPER INSTALLATION PROCEDURE BY QUALIFIED PERSONNEL AS
OUTLINED IN THE INSTALLATION INSTRUCTIONS MUST BE ADHERED TO.
FAILURE TO DO SO COULD RESULT IN SERIOUS PERSONAL INJURY AND
POSSIBLE DAMAGE TO THE FLAT PANEL.
WARNING:
INVERT THE FLAT PANEL, PLACE IT ON A SOFT, FLAT SUFRACE TO
PREVENT DAMAGE TO THE FLAT PANEL. USE A BLANKET, FOAM, ETC.
FAILURE TO DO SO WILL RESULT IN DAMAGING THE FLAT PANEL. DO NOT
LAY THE FLAT PANEL ON THE FLOOR WITHOUT ANY PROTECTION TO THE
GLASS. THE FLAT PANEL IS HEAVY AND FRAGILE. AT LEAST (2) QUALIFIED
PERSONNEL ARE STRONGLY RECOMMENDED FOR INSTALLATION OF THIS
PRODUCT. FAILURE TO DO SO COULD RESULT IN SERIOUS INJURY AND
POSSIBLE DAMAGE TO THE FLAT PANEL.
Step 1 Step 2
Once the flat panel is inverted, use a measuring
tape to find the center of your flat panel
measuring from outside to outside of the
chassis (Figure 1).
Top of flat
panel
Using a pencil lightly mark the center of your flat
panel (Figure 2).
Mark the center of
the flat panel
Inverted flat panel
C
Measuring
tape
Figure 1
L
Bottom of flat
panel
C
L
Inverted flat panel
Figure 2
- 5 -
A
3.0 POSITIONING THE MOUNTING BRACKETS
Step 3 Step 4
Lay the mounting brackets (stamped arrows
facing out) Figure 3.
Mounting brackets
Bottom of flat panel
Arrows facing out
Match the center of viewing guide with the center
line you marked in Step 1 (Figure 4).
lign the mounting
brackets
C
L
Figure 3 Figure 4
Step 5
The mounting brackets are designed with a
center of viewing guide on the side of them
(Figure 5).
Mounting bracket
Bottom of flat
panel
Bottom of flat panel
Center of
viewing guide
Figure 5
- 6 -
4.0SECURING THE MOUNTING BRACKETS
Step 6 Step 7
The Griplates™ have M4, M5, M6 and M8 hole
patterns to fit the hardware that your flat panel
requires.
EXAMPLE: If your plasma uses M8 x 20 Phillip
screws. Use the M8 mounting points (Figure 6).
DIMPLES
M5 M4
M6
M8
Once the mounting brackets are aligned, secure
the Griplate™ to the flat panel.
NOTE
: The dimples of the top plates have to be
facing up and the bottom dimples must
be facing down. Use (1) Griplate™ per
mounting point (Figure 7).
Phillips screw driver
DIMPLES
FACING UP
DIMPLES
FACING UP
DIMPLES
FACING DOWN
DIMPLES
FACING DOWN
Bottom of flat
panel
Figure 6
Figure 7
- 7 -
)
5.0WOODEN STUD LOCATION
Step 8 Step 9
Using a (commercially available) wood stud
finder, locate the 16" or 24" stud centers behind
the wall. Once found, make a pencil marking on
the center of the wood studs (Figure 8).
NOTE: The wall plates have three 16" and one 24" mounting slot positions.
Wood stud finder
(commercially
available
Mark the
wall and the
center of the
wood studs.
Align the center viewing port from the carton
template to the center of the wood studs
horizontally. Match the center of viewing port to
the center of viewing height desired and mark a
line on the bottom of the carton template (Figure
9).
NOTE: This marking will reference the center of
your flat panel display once mounted on
the wall (Figure 9).
Center of viewing
port
16"
16"
16"
Mark the
bottom of the
carton template
D
E
R
I
S
E
Wood studs
behind the
wall
structure
D
T
H
G
I
E
H
G
N
I
W
E
I
V
F
O
R
E
T
N
E
C
Carton template
Center of
viewing mark
Figure 8
Figure 9
- 8 -
6.0 MOUNTING POINT LOCATION
Step 10 Step 11
Place the bottom portion of the wall plate to the
reference line and mark the four (4) lag bolt
mounting points through the wall plate slots on
the wall. Level the wall plate with the reference
arrow pointing up to the ceiling (Figure 10).
Wood Studs: Drill four (4) ¼" pilot holes to the
marked wall.
Concrete Wall: Drill four (4) 3/8” pilot holes to the
marked wall. See Figure 11.
Pilot
holes
16"
Wall plate
16"
Wood Studs
Mounting
slots
Drill gun
Level
Figure 10
Figure 11
- 9 -
W
W
)
7.0 SECURING THE WALL PLATES
Step 12 – Wooden Studs Step 13 - Concrete
Level and secure the plate to the wall with the
reference arrow facing up to the ceiling.
Secure the plate using the four (4) 5/16" lag
bolts and flat washers (Figure 12).
NOTE: Use a minimum diameter of 5/16” x 3” long wood screws.
CAUTION: Do not over tighten the lag bolts.
Level
Level and secure the plate to the wall
with the reference arrow facing up to the
ceiling. Use a minimum diameter of 5/16”
x 2 ¼” lag concrete wedge anchors
(commercially available). See Figure 13.
NOTE
: Use a minimum diameter of
5/16” x 2 ¼” long wedge
anchors commercially
available).
CAUTION
: Do not over tighten the
wedge anchors bolts.
(4) 5/16" x 3"
lag bolts and
(4) flat
washers
all plate
all plate
Figure 12
Figure 13
(4) 5/16" x 2
¼” wedge
anchors
(commercially
available
- 10 -
W
8.0 FLAT PANEL INSTALLATION
Step 15
WARNING: AT LEAST (2) QUALIFIED PERSONNEL ARE STRONGLY RECOMMENDED FOR
INSTALLATION OF THIS PRODUCT. FAILURE TO DO SO COULD RESULT IN
SERIOUS INJURY AND POSSIBLE DAMAGE TO THE FLAT PANEL
Raise the flat panel with the mounting brackets secured to the flat panel and insert the top and
bottom hooks from each bracket to the rods from the wall plates (Figure 15).
all plate
TOP
BOTTOM
Figure 15
9.0 LATERAL SHIFT ADJUSTMENT
Step 16
Make any lateral shift adjustment and lock it by tightening the two (2) M6 x 30 (mm) Phillips screws
found on the bottom of the mounting brackets.
CAUTION: Do not over tighten the M6 screws to the rods (Figure 16).
Lateral shift
Figure 16
- 11 -
10.0 TECHNICAL SPECIFICATIONS
Dimensions are in Inches and (mm)
H
28.000
(171.2)
16.000
(406.4)
C
1.245
(31.75)
L
A
B
5.000
(127)
12.000
19.000
(304.8)
(482.6)
A. Wall plates
B. Mounting brackets
C. Griplate™
D. Mounting hardware
E. M6 x 30 (mm) Phillip
screws
F. Wood stud
G. 5/16” x 3” Lag screws and
flat washers
H. Safety knobs
21.000
10.500
(266.7)
5.000
(127)
(533.4)
C
L
C
G
16.000
H
(406.4)
G
20.500
(520.7)
F
16.000
(406.4)
(616.97)
24.290
16.000
(406.4)
2.331
(59.21)
D
E
1
2
FINE TUNE TILT ADJUSTMENTS
1. M5 Phillips screws for fine
tension
2. M8 Hex nut coarse tension
NOTE
: The 8 (mm) hex nut is for
your coarse tension adjustment
and the 5 (mm) screws are for your
fine tension adjustment.
- 12 -
Figure 17
www.marantz.com
You can find your nearest authorized distributor or dealer on our website.
U.S.A.
Marantz America, Inc. 1100 Maplewood Drive, Itasca, IL 60143, U.S.A.
is a registered trademark.
- 13 -
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.