Marantz CD-5400-1 Sevice Bulletin

SERVICE BULLETIN
See below
Date: 27-Sep-2004 Model: CD5400
Page: 1 / 1 REF.NBR: MZ04-064
Subject:
Capacitors change of the Power Supply.
[PHENOMENON]
Capacitors C903 and C904 may short-circuit very rarely.
[REASONS]
The shortage of voltage-proof of the capacitor.
[SOLUTION]
1. POS.NO C903 and C904 CAP,CERAMIC(0.1uF 50V) is changed to part no.90M-DK100920R(0.1uF 100V).
[NECESSARY PART]
POS.NO C903 / C904 90M-DK100920R
[REMARKS]
1. This problem apply to the following week code.
CD5400 apply to MZ010425xxxxxx
2. This improvement has been done in the production week code MZ010426xxxxxx and after.
C903
C904
( 0.1uF 100V “Factory part no. CR051BX7R104K101F”)
Int.ref:
Approved by S.NAGAO Written by
WQ-19 2 817
/additional rule 3 (1st Issue 2003-03-19)