Marantz CD-5400-1 Sevice Bulletin

0 (0)
Marantz CD-5400-1 Sevice Bulletin

 

 

 

Date: 27-Sep-2004

Model: CD5400

 

 

 

 

 

 

SERVICE

BULLETIN

Page:

1 / 1

REF.NBR: MZ04-064

 

 

 

Subject:

 

 

 

 

 

 

 

 

 

 

 

 

 

Level

 

Application:

Capacitors change of the Power Supply.

 

 

 

 

 

See below

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Int.ref:

 

 

 

 

 

 

 

 

[PHENOMENON]

 

 

 

 

 

Capacitors C903 and C904 may short-circuit very rarely.

[REASONS]

The shortage of voltage-proof of the capacitor.

[SOLUTION]

1. POS.NO C903 and C904 CAP,CERAMIC(0.1uF 50V) is changed to part no.90M-DK100920R(0.1uF 100V).

C903

C904

[NECESSARY PART]

POS.NO C903 / C904 90M-DK100920R ( 0.1uF 100V “Factory part no. CR051BX7R104K101F”)

[REMARKS]

1.This problem apply to the following week code. CD5400 apply to MZ010425xxxxxx

2.This improvement has been done in the production week code MZ010426xxxxxx and after.

Approved by S.NAGAO Written by

WQ-19 2 817/additional rule 3 (1st Issue 2003-03-19)