This manual is updated as new information and models
are released. Visit our website for the latest manual.
www.manitowocice.com
Part Number STH042 7/15
Safety Notices
As you work on Manitowoc equipment, be sure to pay
close attention to the safety notices in this handbook.
Disregarding the notices may lead to serious injury and/
or damage to the equipment.
Throughout this handbook, you will see the following
types of safety notices:
Warning
Text in a Warning box alerts you to a potential
personal injury situation. Be sure to read the Warning
statement before proceeding, and work carefully.
Caution
Text in a Caution box alerts you to a situation in which
you could damage the equipment. Be sure to read
the Caution statement before proceeding, and work
carefully.
Procedural Notices
As you work on Manitowoc equipment, be sure to read
the procedural notices in this handbook. These notices
supply helpful information which may assist you as you
work.
Throughout this handbook, you will see the following
types of procedural notices:
Important
Text in an Important box provides you with
information that may help you perform a procedure
more efficiently. Disregarding this information will
not cause damage or injury, but it may slow you
down as you work.
NOTE: Text set off as a Note provides you with simple, but
useful, extra information about the procedure you are
performing.
Read These Before Proceeding:
Caution
Proper installation, care and maintenance are
essential for maximum performance and troublefree operation of your Manitowoc equipment. If you
encounter problems not covered by this manual, do
not proceed, contact Manitowoc Foodservice. We will
be happy to provide assistance.
Caution
Proper installation, care and maintenance are
essential for maximum performance and trouble-free
operation of your equipment. Visit our website www.
manitowocfsg.com for manual updates, translations,
or contact information for service agents in your area.
Important
Routine adjustments and maintenance procedures
outlined in this handbook are not covered by the
warranty.
Warning
Read this manual thoroughly before operating,
installing or performing maintenance on the
equipment. Failure to follow instructions in this
manual can cause property damage, injury or death.
Warning
Do not use electrical appliances or accessories other
than those supplied by Manitowoc for your ice
machine model.
Warning
Two or more people or a lifting device are required to
lift this appliance.
Warning
This equipment contains high voltage electricity and
refrigerant charge. Installation and repairs are to be
performed by properly trained technicians aware of
the dangers of dealing with high voltage electricity
and refrigerant under pressure. The technician must
also be certified in proper refrigerant handling
and servicing procedures. All lockout and tag out
procedures must be followed when working on this
equipment.
Warning
Do not damage the refrigeration circuit when installing,
maintaining or servicing the unit.
Important
This product is hermetically sealed and contains
fluorinated greenhouse gas R404A
Warning
Do not operate equipment that has been misused,
abused, neglected, damaged, or altered/modified
from that of original manufactured specifications.
This appliance is not intended for use by persons
(including children) with reduced physical, sensory
or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision
concerning use of the appliance by a person
responsible for their safety. Do not allow children to
play with this appliance.
Warning
All covers and access panels must be in place and
properly secured, before operating this equipment.
Warning
Do not obstruct machine vents or openings.
Warning
Do not store gasoline or other flammable vapors or
liquids in the vicinity of this or any other appliance.
Warning
Do not clean with water jet.
Warning
It is the responsibility of the equipment owner to
perform a Personal Protective Equipment Hazard
Assessment to ensure adequate protection during
maintenance procedures.
Warning
Two or more people are required to move this
equipment to prevent tipping.
Warning
When using electric appliances, basic precautions
must always be followed, including the following:
a. Read all the instructions before using the
appliance.
b. To reduce the risk of injury, close supervision
is necessary when an appliance is used near
children.
c. Do not contact moving parts.
d. Only use attachments recommended or sold
by the manufacturer.
e. Do not use outdoors.
f. For a cord-connected appliance, the following
must be included:
• Do not unplug by pulling on cord. To
unplug, grasp the plug, not the cord.
• Unplug from outlet when not in use and
before servicing or cleaning.
• Do not operate any appliance with
a damaged cord or plug, or after the
appliance malfunctions or is dropped
or damaged in any manner. Contact
the nearest authorized service facility
for examination, repair, or electrical or
mechanical adjustment.
g. Follow applicable lock out tag out procedures
before working on equipment.
h. Connect to a properly grounded outlet only.
We reserve the right to make product improvements at
any time. Specifications and design are subject to change
An ice machine contains high voltage electricity and
refrigerant charge. Repairs are to be performed by
properly trained refrigeration technicians aware of
the dangers of dealing with high voltage electricity
and refrigerant under pressure.
A - Air-cooled
W - Water-cooled
Warning
14 Part Number STH042 7/15
Ice Machine Warranty Information
Owner Warranty Registration Card
General
Warranty coverage begins the day the ice machine is
installed.
Important
Complete and mail the OWNER WARRANTY
REGISTRATION CARD as soon as possible to validate
the installation date.
If the OWNER WARRANTY REGISTRATION CARD is not
returned, Manitowoc will use the date of sale to the
Manitowoc Distributor as the first day of warranty
coverage for your new ice machine.
COMMERCIAL WARRANTY COVERAGE
General
The following Warranty outline is provided for your
convenience. For a detailed explanation, read the
warranty bond shipped with each product.
Contact your local Manitowoc representative or
Manitowoc Ice, if you need further warranty information.
Parts
1. Manitowoc warrants the ice machine against defects
in materials and workmanship, under normal use
and service for three (3) years from the date of
original installation.
2. The evaporator and compressor are covered by an
additional two (2) year (five years total) warranty
beginning on the date of the original installation.
Labor
1. Labor required to repair or replace defective
components is covered for three (3) years from the
date of original installation.
2. The evaporator is covered by an additional two- (2)
year (five years total) labor warranty beginning on
the date of the original installation.
Part Number STH042 7/15 15
Exclusions
The following items are not included in the ice machine’s
warranty coverage:
1. Normal maintenance, adjustments and cleaning as
outlined in this manual.
2. Repairs due to unauthorized modifications to the ice
machine or use of non-standard parts without prior
written approval from Manitowoc Ice.
3. Damage caused by improper installation of the ice
machine, electrical supply, water supply or drainage,
or damage caused by floods, storms, or other acts of
God.
4. Premium labor rates due to holidays, overtime, etc.;
travel time; flat rate service call charges; mileage and
miscellaneous tools and material charges not listed
on the payment schedule. Additional labor charges
resulting from the inaccessibility of equipment are
also excluded.
5. Parts or assemblies subjected to misuse, abuse,
neglect or accidents.
6. Damage or problems caused by installation, cleaning
and/or maintenance procedures inconsistent with
the technical instructions provided in this manual.
7. This warranty is intended exclusively for commercial
application. No warranty is extended for personal,
family, or household purposes.
Authorized Warranty Service
To comply with the provisions of the warranty, a
refrigeration service company qualified and authorized
by your Manitowoc distributor, or a Factory Authorized
Servicer must perform the warranty repair.
Service Calls
Normal maintenance, adjustments and cleaning as
outlined in this manual are not covered by the warranty.
16 Part Number STH042 7/15
RESIDENTIAL WARRANTY COVERAGE
What Does this Limited Warranty Cover?
Subject to the exclusions and limitations below,
Manitowoc Ice (“Manitowoc”) warrants to the original
consumer that any new ice machine manufactured by
Manitowoc (the “Product”) shall be free of defects in
material or workmanship for the warranty period outlined
below under normal use and maintenance, and upon
proper installation and start-up in accordance with the
instruction manual supplied with the Product.
How Long Does this Limited Warranty Last?
Product CoveredWarranty Period
Ice MachineTwelve (12) months
fromthesale date
Who Is Covered by this Limited Warranty?
This limited warranty only applies to the original
consumer of the Product and is not transferable.
What Are MANITOWOC ICE’S Obligations Under this
Limited Warranty?
If a defect arises and Manitowoc receives a valid warranty
claim prior to the expiration of the warranty period,
Manitowoc shall, at its option: (1) repair the Product at
Manitowoc’s cost, including standard straight time labor
charges, (2) replace the Product with one that is new or
at least as functionally equivalent as the original, or (3)
refund the purchase price for the Product. Replacement
parts are warranted for 90 days or the balance of the
original warranty period, whichever is longer. The
foregoing constitutes Manitowoc’s sole obligation and
the consumer’s exclusive remedy for any breach of this
limited warranty. Manitowoc’s liability under this limited
warranty is limited to the purchase price of Product.
Additional expenses including, without limitation,
service travel time, overtime or premium labor charges,
accessing or removing the Product, or shipping are the
responsibility of the consumer.
Part Number STH042 7/15 17
What Is Not Covered?
This limited warranty does cover, and you are solely
responsible for the costs of: (1) periodic or routine
maintenance, (2) repair or replacement of the Product
or parts due to normal wear and tear, (3) defects or
damage to the Product or parts resulting from misuse,
abuse, neglect, or accidents, (4) defects or damage to the
Product or parts resulting from improper or unauthorized
alterations, modifications, or changes; and (5) defects or
damage to any Product that has not been installed and/
or maintained in accordance with the instruction manual
or technical instructions provided by Manitowoc. To the
extent that warranty exclusions are not permitted under
some state laws, these exclusions may not apply to you.
EXCEPT AS STATED IN THE FOLLOWING SENTENCE,
THIS LIMITED WARRANTY IS THE SOLE AND EXCLUSIVE
WARRANTY OF MANITOWOC WITH REGARD TO THE
PRODUCT. ALL IMPLIED WARRANTIES ARE STRICTLY
LIMITED TO THE DURATION OF THE LIMITED WARRANTY
APPLICABLE TO THE PRODUCTS AS STATED ABOVE,
INCLUDING BUT NOT LIMITED TO, ANY WARRANTY OF
MERCHANTABILITY OR OF FITNESS FOR A PARTICULAR
PURPOSE. Some states do not allow limitations on how
long an implied warranty lasts, so the above limitation
may not apply to you.
IN NO EVENT SHALL MANITOWOC OR ANY OF
ITS AFFILIATES BE LIABLE TO THE CONSUMER
OR ANY OTHER PERSON FOR ANY INCIDENTAL,
CONSEQUENTIAL OR SPECIAL DAMAGES OF ANY
KIND INCLUDING, WITHOUT LIMITATION, LOSS OF
PROFITS, REVENUE OR BUSINESS ARISING FROM OR IN
ANY MANNER CONNECTED WITH THE PRODUCT, ANY
BREACH OF THIS LIMITED WARRANTY, OR ANY OTHER
CAUSE WHATSOEVER, WHETHER BASED ON CONTRACT,
TORT OR ANY OTHER THEORY OF LIABILITY. Some states
do not allow the exclusion or limitation of incidental
or consequential damages, so the above limitation or
exclusion may not apply to you.
18 Part Number STH042 7/15
How State Law Applies
This limited warranty gives you specific legal rights, and
you may also have rights that vary from state to state or
from one jurisdiction to another.
Registration Card
To secure prompt and continuing warranty service, this
warranty registration card must be completed and sent
to Manitowoc within thirty (30) days from the sale date.
Complete the following registration card and send it to
Manitowoc at the address shown above. Retain a copy for
your records.
HOW TO OBTAIN WARRANTY SERVICE
To obtain warranty service or information regarding your
Product, please contact us at:
MANITOWOC ICE
2110 S. 26
th
St.,
P.O. Box 1720
Manitowoc, WI 54221-1720
Telephone: 920-682-0161 Fax: 920-683-7585
www.manitowocice.com
Part Number STH042 7/15 19
THIS PAGE INTENTIONALLY LEFT BLANK
20 Part Number STH042 7/15
Installation
Location of Ice Machine
The location selected for the ice machine must meet
the following criteria. If any of these criteria are not met,
select another location.
• The location must be indoors.
• The location must be free of airborne and other
contaminants.
• Air temperature: Must be at least 40°F (4°C) but must
not exceed 110°F (43.4°C).
• The location must not be near heat-generating
equipment or in direct sunlight.
• The location must be capable of supporting the
weight of the ice machine and a full bin of ice.
• The location must allow enough clearance for water,
drain, and electrical connections in the rear of the ice machine.
• The location must not obstruct airflow through or
around the ice machine (condenser airflow is in and
out the front). Refer to the chart below for clearance
requirements.
• The ice machine must be protected if it will be
subjected to temperatures below 32°F (0°C). Failure
caused by exposure to freezing temperatures is not
covered by the warranty.
Part Number STH042 7/15 21
Ice Machine Clearance Requirements
Self-contained
Air-cooled
Top/Sides5" (127 mm)*5" (127 mm)*
Back5" (127 mm)*5" (127 mm)*
*The ice machine may be built into a cabinet.
There is no minimum clearance requirement for the top
or left and right sides of the ice machine. The listed values
are recommended for efficient operation and servicing
only.
* B.T.U./Hour
** Because the heat of rejection varies during the ice making
cycle, the figure shown is an average.
Ice machines, like other refrigeration equipment, reject
heat through the condenser. It is helpful to know the
amount of heat rejected by the ice machine when sizing
air conditioning equipment where self-contained aircooled ice machines are installed.
Heat of Rejection*
Air Conditioning**Peak
22 Part Number STH042 7/15
Leveling the Ice Machine
1. Screw the leveling legs onto the bottom of the ice
machine.
2. Screw the foot of each leg in as far as possible.
Caution
The legs must be screwed in tightly to prevent them
from bending.
3. Move the ice machine into its final position.
4. Level the ice machine to ensure that the siphon
system functions correctly. Use a level on top of the
ice machine. Turn each foot as necessary to level the
ice machine from front to back and side to side.
THREAD
LEVELING LEG
INTO BASE OF
CABINET
THREAD “FOOT”
IN AS FAR AS
POSSIBLE
SV1606
Leg Installation
Part Number STH042 7/15 23
Electrical Requirements
Voltage
The maximum allowable voltage variation is ±10% of the
rated voltage on the ice machine model/serial number
plate at start-up (when the electrical load is highest).
Fuse/Circuit Breaker
A separate fuse/circuit breaker must be provided for each
ice machine.
Total Circuit Ampacity
The total circuit ampacity is used to help select the wire
size of the electrical supply.
The wire size (or gauge) is also dependent upon
location, materials used, length of run, etc., so it must be
determined by a qualified electrician.
24 Part Number STH042 7/15
Electrical Specifications
Air-cooled Ice Machine
Ice Machine
U140
U190
U240
U310
Voltage
Phase Cycle
115/1/60155.0
208-230/1/60152.5
230/1/50152.5
115/1/60156.0
208-230/1/60152.5
230/1/50152.5
115/1/60157.0
208-230/1/60154.0
230/1/50154.0
115/1/601510.0
208-230/1/60154.5
230/1/50154.5
Max. Fuse/
Circuit
Breaker
Total Amps
Part Number STH042 7/15 25
Water-cooled Ice Machine
Max. Fuse/
Circuit
Breaker
Warning
Total Amps
Ice Machine
U140
U240
U310
Voltage
Phase Cycle
115/1/60155.0
208-230/1/60152.5
230/1/50152.5
115/1/60157.0
208-230/1/60154.0
230/1/50154.0
115/1/601510.0
208-230/1/60154.5
230/1/50154.5
All wiring must conform to local, state and national
codes.
Warning
The ice machine must be grounded in accordance
with national and local electrical code.
26 Part Number STH042 7/15
Water Service/Drains
WATER SUPPLY
Local water conditions may require treatment of the
water to inhibit scale formation, filter sediment, and
remove chlorine odor and taste.
Important
If you are installing a Manitowoc water filter system,
refer to the Installation Instructions supplied with the
filter system for ice making water inlet connections.
Warning
For ice making, connect to a potable water supply
only.
WATER INLET LINES
Follow these guidelines to install water inlet lines:
• Do not connect the ice machine to a hot water
supply. Be sure all hot water restrictors installed for
other equipment are working. (Check valves on sink
faucets, dishwashers, etc.)
• If water pressure exceeds the maximum
recommended pressure, 80 psig (5.5 bar) obtain
a water pressure regulator from your Manitowoc
distributor.
• Install a water shut-off valve for ice making potable
water.
• Insulate water inlet lines to prevent condensation.
Part Number STH042 7/15 27
DRAIN CONNECTIONS
Follow these guidelines when installing drain lines
to prevent drain water from flowing back into the ice
machine and storage bin:
• Drain lines must have a 1.5-inch drop per 5 feet of run
(2.5 cm per meter), and must not create traps.
• The floor drain must be large enough to
accommodate drainage from all drains.
• Install a tee to vent the ice machine drain to the
atmosphere.
• Insulate drain lines to prevent condensation.
COOLING TOWER APPLICATIONS
Water Cooled Models Only
A water-cooling tower installation does not require
modification of the ice machine. The water regulator
valve for the condenser continues to control the
refrigeration discharge pressure.
It is necessary to know the amount of heat rejected, and
the pressure drop through the condenser and water
valves (inlet to outlet) when using a cooling tower on an
ice machine.
• Water entering the condenser must not exceed 90°F
(32.2°C).
• Water flow through the condenser must not exceed 5
gallons (19 liters) per minute.
• Allow for a pressure drop of 7 psig (.48 bar) between
the condenser water inlet and the outlet of the ice
machine.
• Water exiting the condenser must not exceed 110°F
(43.3°C).
Caution
Plumbing must conform to state and local codes.
28 Part Number STH042 7/15
WATER SUPPLY AND DRAIN LINE SIZING/
CONNECTIONS
Fitting
to Ice Machine
inside diameter
inside diameter
Tubing Size Up
Fitting
Ice Machine
Water
Pressure
3/8" (9.5 mm) min.
3/8” Female
Pipe Thread
20 psi (138 kPa) min.
80 psi (550 kPa) max.
inside diameter
3/8" (9.5 mm) min.
3/8" (9.5 mm) min.
3/8” Female
3/8” Female
Pipe Thread
Pipe Thread
20 psi (1.38 bar) min.
150 psi (10.3 bar) max.
Water
Temperature
40°F (4°C) min.
90°F (32°C) max.
Location
Ice Making
Water Inlet
Part Number STH042 7/15 29
——
40°F (4°C) min.
90°F (32°C) max
Condenser
Condenser
Water Inlet
Water Drain
THIS PAGE INTENTIONALLY LEFT BLANK
30 Part Number STH042 7/15
Maintenance
Interior Cleaning and Sanitizing
GENERAL
Clean and sanitize the ice machine every six months
for efficient operation. If the ice machine requires
more frequent cleaning and sanitizing, consult a
qualified service company to test the water quality and
recommend appropriate water treatment.
The ice machine must be taken apart for cleaning and
sanitizing.
Caution
Use only Manitowoc approved Ice Machine Cleaner
and Sanitizer. It is a violation of Federal law to use
these solutions in a manner inconsistent with their
labeling. Read and understand all labels printed on
bottles before use.
CLEANING AND SANITIZING PROCEDURE
Ice machine cleaner is used to remove lime scale and
mineral deposits. Ice machine sanitizer disinfects and
removes algae and slime.
Part Number STH042 7/15 31
TOUCH PAD OPERATION
Pressing and holding the clean button for 3 seconds
starts the clean cycle. The Clean & On/Off lights energize
indicating the clean cycle has started and ice making will
automatically start when the Clean cycle is complete.
• Setting the ice machine to stop after the clean cycle: Press the On/Off button. The On/Off light will
de-energize indicating the ice machine will stop after
the clean cycle.
• Pausing the cleaning cycle: Press the Clean button.
The clean light will flash indicating the clean cycle has
paused. Pressing the Clean button again will restart
the clean cycle.
Step 1 Press the On/Off button after ice falls from the
evaporator at the end of a Harvest cycle. Or, press the On/
Off button and allow the ice to melt off the evaporator.
Caution
Never use anything to force ice from the evaporator.
Damage may result.
Step 2 Remove all ice from the bin.
Warning
Wear rubber gloves and safety goggles (and/or
face shield) when handling Ice Machine Cleaner or
Sanitizer.
32 Part Number STH042 7/15
Caution
Do not mix Ice Machine Cleaner and Sanitizer
solutions together. It is a violation of Federal law to
use these solutions in a manner inconsistent with
their labeling.
Step 3 To start a cleaning cycle, press the Clean
button. Water will flow through the water dump valve
and down the drain. Wait until the water trough refills,
then add the proper amount of ice machine cleaner to
the water trough.
Wait until the clean cycle is complete (approximately 22
minutes) then press the On/Off button and disconnect
power and water supplies to the ice machine.
Step 4 Remove parts for cleaning.
Refer to the proper parts removal for your machine.
Continue with step 5 when the parts have been removed.
Part Number STH042 7/15 33
Step 5 Mix a solution of cleaner and warm water.
Depending on the amount of mineral buildup, a larger
quantity of solution may be required. Use the ratio in the
table below to mix enough solution to thoroughly clean
all parts.
Solution TypeWaterMixed with
Cleaner1 gal. (4 l)16 oz (500 ml) cleaner
Use half of the cleaner/water solution to clean all
components. The cleaner solution will foam when it
contacts lime scale and mineral deposits; once the
foaming stops use a soft bristle brush, sponge or cloth
(not a wire brush) to carefully clean the parts. Soak the
parts for 5 minutes (15 – 20 minutes for heavily scaled
parts). Rinse all components with clean water.
Step 6 While components are soaking, use half of the
cleaner/water solution to clean all foodzone surfaces of
the ice machine and bin. Use a nylon brush or cloth to
thoroughly clean the following ice machine areas:
• Evaporator plastic parts – including top, bottom and
sides
• Bin bottom, sides and top
• Rinse all areas thoroughly with clean water.
34 Part Number STH042 7/15
Step 7 Mix a solution of sanitizer and warm water.
Solution TypeWaterMixed With
Sanitizer3 gal. (12 l)2 oz (60 ml) sanitizer
Use half of the sanitizer/water solution to sanitize all
removed components. Use a spray bottle to liberally
apply the solution to all surfaces of the removed parts or
soak the removed parts in the sanitizer/water solution.
Do not rinse parts after sanitizing.
Step 8 Use half of the sanitizer/water solution to
sanitize all foodzone surfaces of the ice machine and bin.
Use a spray bottle to liberally apply the solution. When
sanitizing, pay particular attention to the following areas:
• Evaporator plastic parts - including top, bottom and
sides
• Bin bottom, sides and top
Do not rinse the sanitized areas.
Step 9 Replace all removed components, wait
10 minutes, then reapply power and water to the ice
machine
Step 10 Press the Clean button. Water will flow through
the water dump valve and down the drain. Wait until the
water trough refills, then add the proper amount of ice
machine sanitizer to the water trough.
Wait until the sanitize cycle is complete (approximately
22 minutes) then press the Ice button to start ice making.
Part Number STH042 7/15 35
REMOVE PARTS FOR CLEANING
Warning
Disconnect electric power to the ice machine at the
electric switch box before proceeding.
1. Remove the Harvest Float Switch and Ice Thickness
Float Switch
• Pull forward on the bottom of the bracket until
clear of the tab, then slide bracket upward to
remove the bracket and float as an assembly.
At this point, the float switches can easily be
cleaned. If complete removal is desired, follow
the wires to the bulkhead grommet (exit point)
in the back wall. Pull the wire connector through
the bulkhead grommet, then disconnect the wire
leads from the connector.
NOTE: The wire from the top grommet goes to the ice
thickness float switch (front switch). The wire from the
bottom grommet goes to the Harvest float switch (side
switch).
36 Part Number STH042 7/15
WIRE CONNECTORS ARE LOCATED BEHIND BULKHEAD
PULL THROUGH GROMMET TO DISCONNECT
HARVEST FLOAT
SWITCH & BRACKET
DISCONNECT WIRES
FOR COMPLETE
ICE THICKNESS FLOAT
SWITCH & BRACKET
REMOVAL
Part Number STH042 7/15 37
2. Remove the Water Trough
• Remove the upper thumbscrew.
• While supporting the water trough remove the
thumbscrew from beneath the water trough.
• Remove the water trough from the bin area.
UPPER THUMBSCREWLOWER THUMBSCREW
38 Part Number STH042 7/15
3. Remove the Ice Damper
• Remove thumbscrew from bin switch cover.
• Support ice damper and then pull bin switch
cover and ice damper forward to remove.
1. REMOVE THUMBSCREW
2. SUPPORT ICE DAMPER THEN
SLIDE RIGHT SIDE FORWARD TO REMOVE
Part Number STH042 7/15 39
4. Remove the Water Distribution Tube
• Distribution tube thumbscrews are retained to
prevent loss. Loosen thumbscrews but do not
pull thumbscrews out of distribution tube.
• Loosen the two outer screws and pull forward on
the distribution tube to release.
NOTE: For ease of assembly when reinstalling the water
distribution tube, install the top edge first.
1. LOOSEN THUMBSCREWS
2. PULL DISTRIBUTION TUBE
FORWARD TO REMOVE
40 Part Number STH042 7/15
Preventative Maintenance Cleaning
This cleaning procedure can be performed between the
bi-annual cleaning and sanitizing cycles. This procedure
does not require removing the ice from the bin.
Step 1 Press the On/Off button after ice falls from the
evaporator at the end of a Harvest cycle. Or, press the On/
Off button and allow the ice to melt off the evaporator.
Caution
Never use anything to force ice from the evaporator.
Damage may result.
Warning
Wear rubber gloves and safety goggles (and/or
face shield) when handling Ice Machine Cleaner or
Sanitizer.
Step 2 To start a cleaning cycle, press the Clean
button. Water will flow through the water dump valve
and down the drain. Wait until the water trough refills,
then add the proper amount of ice machine cleaner to
the water trough.
Wait until the clean cycle is complete (approximately 22
minutes) then press the On/Off button.
Part Number STH042 7/15 41
Ice Machine Inspection
Check all water fittings and lines for leaks. Also, make
sure the refrigeration tubing is not rubbing or vibrating
against other tubing, panels, etc.
Do not put anything (boxes, etc.) in front of the ice
machine. There must be adequate airflow through and
around the ice machine to maximize ice production and
ensure long component life.
Exterior Cleaning
Clean the area around the ice machine as often as
necessary to maintain cleanliness and efficient operation.
Sponge any dust and dirt off the outside of the ice
machine with mild soap and water. Wipe dry with a clean,
soft cloth.
A commercial grade stainless steel cleaner/polish can be
used as necessary.
Cleanup any fallen ice or water spills as they occur.
42 Part Number STH042 7/15
Cleaning the Condenser
General
Warning
Disconnect electric power to the ice machine head
section and the remote condensing unit at the electric
service switches before cleaning the condenser.
A dirty condenser restricts airflow, resulting in excessively
high operating temperatures. This reduces ice production
and shortens component life.
• Clean the condenser at least every six months.
Warning
The condenser fins are sharp. Use care when cleaning
them.
• Shine a flashlight through the condenser to check for
dirt between the fins.
• Blow compressed air or rinse with water from the
inside out (opposite direction of airflow).
• If dirt still remains call a service agent to clean the
condenser.
Part Number STH042 7/15 43
Removal from Service/Winterization
1. Clean and sanitize the ice machine.
2. Press the On/Off button to turn off the ice machine.
3. Turn off the water supply, disconnect and drain the
incoming ice-making water line at the rear of the ice
machine and drain the water trough.
4. Energize the ice machine, wait one minute for the
water inlet valve to open and blow compressed air in
both the incoming water and the drain openings in
the rear of the ice machine to remove all water.
5. Press the On/Off button and disconnect the electric
power at the circuit breaker or the electric service
switch.
6. Fill spray bottle with sanitizer and spray all interior
food zone surfaces. Do not rinse and allow to air dry.
7. Replace all panels.
44 Part Number STH042 7/15
Bin Removal
1. Disconnect power.
2. Remove all ice from bin.
3. Remove air filter and louver from lower front of
machine.
4. Loosen top screw, remove bottom screw and slide
plates to release.
5. Disconnect clamp and remove bin drain.
6. Remove control box panel.
7. Remove communication cable from control board.
8. Remove rear cover.
9. Slide bin forward to remove.
NOTE: When reinstalling the bin, ensure the bin seal is
in place and is not pinched/folded as it mates to the
cabinet. A watertight seal is required to prevent future
condensation or water leakage from entering the ice
machine base.
DISCONNECT CLAMP
AND REMOVE BIN DRAIN
SCREWS AND PLATES
DISCONNECT COMMUNICATION CABLE
Part Number STH042 7/15 45
THIS PAGE INTENTIONALLY LEFT BLANK
46 Part Number STH042 7/15
Operation
Touch Pad Features
The touch pad offers a series of pressure sensitive buttons
to control ice machine operation and provide operational
status.
On/Off - Blue = Machine On
Off = Machine Is Off
Delay - Blue = Delay Mode On
Off = Delay Mode Is Off
Clean - Yellow = Clean Cycle On
Off = Cleaning is Off
Flashing = Cleaning Is Paused
Bin Full - Blue = Bin Is Full
Off = Bin Is Not Full
Service - Red = Needs Service
Off = Doesn’t Need Service
ON/OFF
The On/Off Button is used to start and stop ice making.
The blue light indicates whether the ice machine is in Ice
Making (light on) or Off (light off ).
NOTE: Stopping and restarting a freeze cycle with ice on
the evaporator will result in a thick bridge and larger than
normal cubes.
Part Number STH042 7/15 47
DELAY
Pressing the Delay button will start a delay period. The ice
machine will finish the freeze and harvest cycle and then
start the delay period.
• Pressing the button once will start a 4 hour delay
period.
• Pressing the button twice will start a 12 hour delay
period.
• Pressing the button three times will start a 24 hour
delay period.
• Pressing the button four times will cancel the delay
periods.
NOTE: The delay period will be canceled if power is
interrupted to the ice machine. When power is restored,
the ice machine will start an ice making cycle.
CLEAN
Pressing the Clean button for 3 seconds will start a clean
cycle. After the clean cycle is complete, the ice machine
will automatically start an ice making cycle.
• Pressing the Clean button again within 45seconds of
the clean cycle starting will abort the clean cycle.
• Pressing the On/Off button after 45 seconds will
pause the Clean cycle. The On/Off light will flash
on/off to indicate pause mode. Pressing the On/Off
button again will continue the Clean cycle from the
point of interruption.
• Pressing the control board test button anytime
during the clean cycle will cancel the clean cycle.
• Opening the damper for 30 seconds during the clean
cycle will start and automatic shutdown sequence.
•
48 Part Number STH042 7/15
BIN FULL
The Bin Full light energizes when the bin is full or is deenergized if the bin is not full.
SERVICE
The service light indicates the machine needs attention.
• Refer to safety limits if this light is energized.
Part Number STH042 7/15 49
Ice Making Sequence of Operation
NOTE: The On/Off button must be depressed and the ice
damper must be closed before the ice machine will start.
Water Purge Cycle
The ice machine purges any remaining water from the
water trough down the drain.
Freeze Cycle
Prechill - The refrigeration system chills the evaporator
before water flow over the evaporator starts. The water
inlet valve energizes during the pre-chill and remains on
until the ice thickness float switch is satisfied.
Freeze - Water flowing across the evaporator freezes
and builds ice on the evaporator. After a sheet of ice has
formed, the harvest float switch signals the control board
to start a harvest cycle.
Harvest Cycle
Any remaining water is purged down the drain as
refrigerant gas warms the evaporator. When the
evaporator warms, the sheet of cubes slides off the
evaporator and into the storage bin. If all cubes fall clear
of the ice damper the ice machine starts another freeze
cycle. The maximum harvest time is a total of 7 minutes.
If the bin switch does not activate within 3.5 minutes, the
harvest cycle extends another 3.5 minutes.
Full Bin Cycle
If the ice damper is held open by ice cubes the ice
machine shuts off. When the ice damper closes the ice
machine starts a new cycle at the water purge.
50 Part Number STH042 7/15
Water Assist Harvest Cycle
The maximum harvest time is a total of 7 minutes.
If the bin switch does not activate within 7 minutes a
water assist harvest cycle initiates using the following
sequence:
1. The compressor de-energizes.
2. The water inlet valve energizes and fills the water
trough.
3. The water pump energizes for 2 minutes and
circulates water over the evaporator.
If the bin switch did not open & close.
4. The water dump valve energizes and drains water
from the water trough.
5. Step 1 through 4 repeat.
6. A freeze cycle starts.
NOTE: If the bin switch opens & closes anytime during the
cycle the ice machine starts a new freeze cycle.
• The maximum water fill time for the water assist
harvest is 105 seconds.
Part Number STH042 7/15 51
CONTROL BOARD TIMERS
• The ice machine is locked into the freeze cycle for 6
minutes before a harvest cycle can be initiated.
• The freeze time lock in feature is bypassed on the
initial cycle (manual start or after a full bin/safety limit
condition).
• If the harvest float switch is in the down position for
10 continuous seconds during the start of a freeze
cycle, a harvest sequence is initiated.
• The maximum freeze time is 45 minutes at which
time the control board automatically initiates a
harvest sequence.
• The maximum harvest time is a total of 7 minutes.
If the bin switch does not activate within 3.5 minutes,
the harvest cycle extends another 3.5 minutes. If 7
minutes is exceeded a Harvest Assist Cycle starts.
• The water fill valve is de-energized 1 minute after the
freeze cycle starts. The control board will energize the
water inlet valve one more times 3 minutes into the
freeze cycle.
52 Part Number STH042 7/15
SAFETY LIMITS
Safety limits are stored and indicated by the control
board. The number of cycles required to stop the ice
machine varies for each safety limit.
Safety limits can be reset by pressing the On/Off button
and starting a new ice making cycle.
A safety limit shutdown is indicated by the red Service
light on the touch pad.
Safety Limit 1
If the freeze time reaches 45 minutes, the control board
automatically initiates a harvest cycle.
• After 3 consecutive 45 minute cycles control board
light SL#1 along with the touch pad Service (wrench)
light will flash on/off at 1 second intervals.
• If 6 consecutive 45-minute freeze cycles occur, the
ice machine stops and the SL#1 light on the control
board and the Service (wrench) light on the touch
pad will be on continuously.
Safety Limit 2
If the harvest time reaches 3.5 minutes, the control board
automatically extends the harvest for 3.5 minutes. After
7 minutes a water assist harvest starts . The control board
returns the ice machine to the freeze cycle after the water
assist harvest ends or the ice falls from the evaporator.
• If three consecutive 3.5 minute harvest cycles occur,
the SL#2 light on the control board will flash on/off at
1 second intervals.
• If three consecutive 3.5 minute harvest cycles occur,
the ice machine stops and the SL#2 light on the
control board and the Service (wrench) light on the
touch pad will be on continuously.
Part Number STH042 7/15 53
Safety Limit 3
If the freeze time reaches 4 minutes and water is not
sensed (float remains down for 10 continuous seconds)
the ice machine stops.
• Safety Limit 3 is bypassed on the initial cycle (manual
start or after a full bin/safety limit condition). For
all subsequent cycles if the freeze time reaches 4
minutes and water is not sensed, the ice machine
stops and initiates a 30 minute delay period. Control
board lights SL#1 and SL#2 along with the touch pad
Service (wrench) light will flash on/off at 1 second
intervals.
• The ice machine automatically restarts at the end of
the 30 minute delay period and stops flashing the
control board and Service (wrench) lights.
• If 100 consecutive failures occur the ice machine
stops and the touch pad Service (wrench) light
remains energized.
54 Part Number STH042 7/15
Length of Time
Ice Thickness
Float Switch
20 seconds
5 seconds
initial cycle
120 Seconds
seconds
Thereafter 60
Until Harvest
Float Switch
CLOSED
closes for 10
continual seconds
THEN OPEN
Harvest
Float Switch
Fan Motor *
Compressor
& Condenser
Valve
Dump
Valve
Water Inlet
Valve
Harvest
OFFONOFFONOFFCLOSEDCLOSED
Initial Start-up
1. Water purge
OFFONOFFOFFONCLOSEDCLOSED
2. Refrigeration
Pump
Water
OPERATION
ICE MAKING
ENERGIZED PARTS CHART
Part Number STH042 7/15 55
SEQUENCE OF
Self-Contained Ice Machines
System Start-up
OFF**OFFONOFFONOPENCLOSED
Freeze
Sequence
3. Pre chill
CLOSED
OPEN THEN
ONOFFON ***OFFON
4. Freeze
Length of Time
Float Switch
Ice Thickness
Harvest
Float Switch
Compressor
& Condenser
20 seconds
Fan Motor *
ONCLOSEDCLOSED
activation
Bin switch
Until bin switch
re-closes
ON
Valve
Dump
Water Inlet
Harvest
Water
ICE MAKING
SEQUENCE OF
56 Part Number STH042 7/15
Valve
Valve
Pump
OPERATION
Harvest
FOR 20
Sequence
THEN
SECONDS
OFFONOFF
5. Water Purge
OFF
OFF****ONOFF****OFF****ONCLOSEDCLOSED
6. Harvest
OFFOFFOFFOFFOFFCLOSEDCLOSED
7. Automatic
Shut-off
water inlet valve for 7 seconds one last time, 3 minutes into the freeze cycle, regardless of float position.
* Condenser Fan Motor: The fan motor is wired through a fan cycle pressure control; therefore, it may cycle on and off.
** Energizes for 3 seconds 56 seconds into prechill for the initial start-up and 30 seconds into every subsequent prechill cycle.
*** The water fill valve is de-energized by the control board 1 minute after the freeze cycle starts - The control board will energize the
**** Will be energized during harvest when time exceeds 3.5 minutes.
Operational Checks
ICE THICKNESS CHECK
After a harvest cycle, inspect the ice cubes in the ice
storage bin. The ice bridge connects the ice cubes and
must be set to maintain an ice bridge thickness of 1/8"
(3.2 mm). To adjust the thickness of the bridge refer to ice
thickness adjustment.
ICE THICKNESS ADJUSTMENT
The ice thickness can be adjusted to three levels.
1. Pull forward on the bottom of the bracket until clear
of the tab.
2. Slide the bracket over the desired tab and release.
• The center position is the normal factory setting.
• To increase bridge thickness, raise the water level.
• To decrease bridge thickness, lower the water
level.
THICKER
BRIDGE
Part Number STH042 7/15 57
FACTORY
DEFAULT
THINNER
BRIDGE
MINIMUM/MAXIMUM SLAB WEIGHT
Minimum
Model
U1401.13 lbs
U1902.26 lbs
U2402.26 lbs
U3102.26 lbs
Ice Weight Per
Cycle lbs
Grams
513 grams
1025 grams
1025 grams
1025 grams
Maximum
Ice Weight Per
Cycle lbs
Grams
1.36 lbs
617 grams
2.93 lbs
1329 grams
2.93 lbs
1329 grams
2.93 lbs
1329 grams
58 Part Number STH042 7/15
Troubleshooting
Control Board Test Mode
NOTE: The ice damper/bin switch can be open or closed
and does not effect the operation of the test mode.
To enter the test mode press and hold the test button on
the control board for 3 seconds. The control board test
mode performs the following functions for a 2 minute
time period:
• Energizes all control board relays
• Energizes all control board lights
• Energizes all touch pad control lights
After 2 minutes the control board will automatically
initiate and complete one ice making cycle, then stop.
Canceling a test cycle:
To cancel a test cycle press the test button a second time.
Restarting a test cycle:
The test cycle will restart each time the test button is
pressed for a 3 second time period.
OPERATING ICE MACHINE WITH BIN AND TOUCH
PAD REMOVED
The ice machine is designed to allow diagnostic
procedures to be performed with the bin removed. The
touch pad is attached to the bin and is disconnected
during the removal process. Use the control board test
mode to operate the ice machine without connecting the
touch pad.
Part Number STH042 7/15 59
Diagnosing an Ice Machine that Will Not Run
Warning
High (line) voltage is applied to the control board
at all times. Removing the control board fuse or
pressing the power button will not remove the power
supplied to the control board.
1. Verify primary voltage is supplied to ice machine and
the fuse/circuit breaker is closed.
2. Verify control board fuse is okay.
NOTE: If any control board lights are on, the fuse is okay.
3. Verify the bin switch functions properly. A defective
bin switch can falsely indicate a full bin of ice.
4. Verify power button functions properly. A defective
power button may keep the ice machine in the OFF
mode. Refer to page 98 touch pad diagnostics when
Steps 1 –3 test good.
5. Be sure Steps 1 – 4 were followed thoroughly.
Intermittent problems are not usually related to the
control board. Replace control board if touch pad
operation is correct.
60 Part Number STH042 7/15
Ice Machine Does Not Cycle Into Harvest
when Water Loses Contact with the Harvest
Float Switch
NOTE: The ice machine will make a thick or double
slab when a new freeze cycle is started with ice already
present on the evaporator.
Two of the most common scenarios are:
• Power is cycled off/on with ice on the evaporator.
• The ice damper/bin switch is opened/closed in the
harvest cycle before the ice releases.
Remove all ice from the evaporator before starting
diagnostic procedures.
Freeze Time Lock-In Feature
The ice machine control system incorporates a freeze
time lock-in feature. This prevents the ice machine from
short cycling in and out of harvest. The control board
locks the ice machine in the freeze cycle for six minutes.
After six minutes a harvest cycle can be initiated. To allow
the service technician to initiate a harvest cycle without
delay, this feature is not used on the first cycle after
pressing the power button OFF and back to ON.
Step 1 Disconnect power to the ice machine, remove
the electrical panel to allow viewing of the control board
lights and pull the wire connector for the harvest float
switch through the bulkhead and disconnect. Attach
a jumper wire to the wire terminals connected to the
control board.
Step 2 Bypass the freeze time lock-in feature by
pressing the power button to cycle the ice machine on.
Wait until water flows over the evaporator, then refer to
chart.
ResultCorrection
10 seconds into the freeze cycle
the ice machine cycles from freeze
to harvest and the control board
harvest light energizes.
The harvest light stays off and the
ice machine remains in freeze.
Refer to Float Switch
Diagnostics.
Proceed to Step 3
Part Number STH042 7/15 61
Step 3 Disconnect the harvest float switch wire from
the control board and place a jumper on the control
board harvest float switch terminals. Bypass the freeze
time lock-in feature by pressing the power button to
cycle the ice machine off/on. Wait until water flows over
the evaporator, then refer to chart.
ResultCorrection
10 seconds into the freeze cycle
the ice machine cycles from freeze
to harvest and the control board
harvest light energizes.
The harvest light comes on, but the
ice machine remains in the freeze
cycle.
The harvest light stays off and the
ice machine remains in freeze.
The ice thickness float
switch wire is causing the
malfunction.
The ice machine is in a 6
minute freeze lock - Cycle
on/off and retest.
Replace the control
board.
62 Part Number STH042 7/15
Ice Machine Cycles Into Harvest Before
Water Loses Contact with the Harvest Float
Switch
Step 1 Disconnect power to the ice machine, remove
the electrical panel to allow viewing of the control board
lights and pull the wire connector for the harvest float
switch through the bulkhead and disconnect.
WIRE CONNECTORS ARE LOCATED BEHIND BULKHEAD
PULL THROUGH GROMMET TO DISCONNECT
HARVEST FLOAT
SWITCH & BRACKET
Part Number STH042 7/15 63
ICE THICKNESS FLOAT
SWITCH & BRACKET
Step 2 Reapply power and press the power button to
cycle the ice machine off/on and bypass the freeze time
lock-in feature. Wait until water flows over the evaporator,
then refer to chart.
ResultCorrection
The harvest light does not come on
and the ice machine stays in freeze.
The harvest light comes on but the
ice machine stays in a freeze cycle.
10 seconds into the freeze cycle
the ice machine cycles from freeze
to harvest and the control board
harvest light energizes.
Refer to Float Switch
Diagnostics
The ice machine is in a 6
minute freeze lock - Cycle
on/off and retest.
Proceed to Step 3.
Step 3 Disconnect the harvest float switch wire
from the control board and bypass the freeze time
lock-in feature by pressing the power button to cycle
the ice machine off/on. Wait until water flows over the
evaporator, then refer to chart.
ResultCorrection
The harvest light does not come on. The harvest float switch
wire is causing the
malfunction.
The harvest light comes on but
the ice machine stays in the freeze
sequence.
10 seconds into the freeze cycle
the ice machine cycles from freeze
to harvest and the control board
harvest light energizes.
The ice machine is in a 6
minute freeze lock - Cycle
on/off and retest.
Replace the control
board.
64 Part Number STH042 7/15
Ice Production Check
The amount of ice a machine produces directly relates to
the operating water and air temperatures. This means an
ice machine with a 70°F (21°C) ambient temperature and
50°F (10°C) water produces more ice than the same ice
machine with 90°F (32°C) ambient and 70°F (21°C) water.
1. Determine the ice machine operating conditions:
Air temp entering condenser:____°
Air temp around ice machine:____°
Water temp entering sump trough:____°
2. Refer to the appropriate 24-Hour Ice Production
Chart (starting on page 121). Use the operating
conditions determined in Step 1 to find published
24-Hour Ice Production:_____
• Times are in minutes.
Example: 1 min. 15 sec. converts to 1.25 min.
(15 seconds ÷ 60 seconds = .25 minutes)
• Weights are in pounds.
Example: 2 lb. 6 oz. converts to 2.375 lb.
(6 oz. ÷ 16 oz. = .375 lb.)
3. Perform an ice production check using the formula
below.
1.+=
Freeze
Time
Harvest
Time
Total Cycle
Time
2.1440÷=
Minutes
in 24 Hrs.
3.x=
Weight
of One
Harvest
Part Number STH042 7/15 65
Total Cycle
Time
Cycles per
Day
Cycles per
Day
Actual
24-Hour
Production
Weighing the ice is the only 100% accurate check.
4. Compare the results of step 3 with step 2. Ice
production is normal when these numbers match
closely. If they match closely, determine if:
• Another larger ice machine is required.
• Relocating the existing equipment to lower the
load conditions is required.
Contact the local Manitowoc distributor for information
on available options and accessories.
66 Part Number STH042 7/15
Installation/Visual Inspection Checklist
Ice machine is not level
• Level the ice machine
Condenser is dirty
• Clean the condenser
Water filtration is plugged (if used)
• Install a new water filter
Water drains are not run separately and/or are not
vented
• Run and vent drains according to the Installation
Manual
Part Number STH042 7/15 67
Water System Checklist
A water-related problem often causes the same
symptoms as a refrigeration system component
malfunction.
Example: A water dump valve leaking during the freeze
cycle, a system low on charge, and a starving TXV have
similar symptoms.
Water system problems must be identified and
eliminated prior to replacing refrigeration components.
Water area (evaporator) is dirty
• Clean as needed
Water inlet pressure not between 20 and 80 psig
(1–5bar, 138–552 kPa)
• Install a water regulator valve or increase the water
pressure
Incoming water temperature is not between 40°F (3°C)
and 90°F (32°C)
• If too hot, check the hot water line check valves in
other store equipment
Water filtration is plugged (if used)
• Install a new water filter
Vent tube is not installed on water outlet drain
• See Installation Instructions
Hoses, fittings, etc., are leaking water
• Repair/replace as needed
Water valve is stuck open, closed or is leaking
• Clean/replace as needed
Water is spraying out of the sump trough area
• Stop the water spray
Uneven water flow across the evaporator
• Clean the ice machine
Water is freezing behind the evaporator
• Correct the water flow
Plastic extrusions and gaskets are not secured to the
evaporator
• Remount/replace as needed
68 Part Number STH042 7/15
Ice Formation Pattern
Evaporator ice formation pattern analysis is helpful in ice
machine diagnostics.
Analyzing the ice formation pattern alone cannot
diagnose an ice machine malfunction. However, when
this analysis is used along with Manitowoc’s Refrigeration
System Operational Analysis Table, it can help diagnose
an ice machine malfunction.
OUTLET
OUTLET
INLET
U0140U0190 U0240 U0310
INLET
Examples of Evaporator Tubing Routing
Normal Ice Formation
Ice forms across the entire evaporator surface.
At the beginning of the Freeze cycle, it may appear that
more ice is forming on the inlet of the evaporator than at
the outlet. At the end of the Freeze cycle, ice formation
at the outlet will be close to, or just a bit thinner than, ice
formation at the inlet. The dimples in the cubes at the
outlet of the evaporator may be more pronounced than
those at the inlet. This is normal.
If ice forms uniformly across the evaporator surface, but
does not do so in the proper amount of time, this is still
considered a normal ice fill pattern.
Part Number STH042 7/15 69
Extremely Thin at Evaporator Outlet
There is no ice, or a considerable lack of ice formation on
the outlet of the evaporator.
Examples: No ice at all at the outlet of the evaporator, but
ice forms at the inlet half of the evaporator. Or, the ice at
the outlet of the evaporator reaches the correct thickness,
but the outlet of the evaporator already has 1/2" to 1" of
ice formation.
Possible cause: Water loss, low on refrigerant, starving
TXV, hot water supply, faulty float valve, etc.
Extremely Thin at Evaporator Inlet
There is no ice, or a considerable lack of ice formation at
the inlet of the evaporator. Examples: The ice at the outlet
of the evaporator reaches the correct thickness, but there
is no ice formation at all at the inlet of the evaporator.
Possible cause: Insufficient water flow, flooding TXV, etc.
Spotty Ice Formation
There are small sections on the evaporator where there is
no ice formation. This could be a single corner, or a single
spot in the middle of the evaporator. This is generally
caused by loss of heat transfer from the tubing on the
backside of the evaporator.
No Ice Formation
The ice machine operates for an extended period, but
there is no ice formation at all on the evaporator.
Possible cause: Water float valve, water pump, starving
expansion valve, low refrigerant charge, compressor, etc.
70 Part Number STH042 7/15
Safety Limit Feature
In addition to the standard safety controls, your
Manitowoc ice machine features built-in safety limits that
will stop the ice machine if conditions arise which could
cause a major component failure.
Service Light: The Service light energizes whenever a
safety limit has been exceeded.
Safety Limit 1
If the freeze time reaches 45 minutes, the control board
automatically initiates a harvest cycle.
• After 3 consecutive 45minute cycles, control board
light SL#1 along with the touch pad service (wrench)
light will flash on/off at 1 second intervals.
• If 6 consecutive 45-minute freeze cycles occur, the
ice machine stops and the SL#1 light on the control
board and the Service (wrench) light on the touch
pad will be on continuously.
Safety Limit 2
If the harvest time reaches 3.5 minutes, the control board
automatically returns the ice machine to the freeze cycle.
• If a 3.5 minute harvest cycles occurs, the SL#2 light
on the control board will flash on/off at 1 second
intervals.
• If 3consecutive 3.5 minute harvest cycles occur, the
ice machine stops and the SL#2 light on the control
board and the Service (wrench) light on the touch
pad will be on continuously.
Part Number STH042 7/15 71
Safety Limit 3
If the freeze time reaches 4 minutes and water is not
sensed (float remains down for 10 continuous seconds)
the ice machine stops.
• Safety Limit 3 is bypassed on the initial cycle (manual
start or after a full bin/safety limit condition). For
all subsequent cycles if the freeze time reaches 4
minutes and water is not sensed, the ice machine
stops and initiates a 30 minute delay period. Control
board lights SL#1 and SL#2 along with the touch pad
Service (wrench) light will flash on/off at 1 second
intervals.
• The ice machine automatically restarts at the end of
the 30 minute delay period and stops flashing the
control board and Service (wrench) lights.
• If 100 consecutive failures occur the ice machine
stops and the touch pad Service (wrench) light
remains energized.
72 Part Number STH042 7/15
Determining Which Safety Limit Stopped the Ice
Machine:
When a safety limit condition causes the ice machine
to stop, the safety limit light on the control board
continually flashes on and off.
CONTROL BOARD SAFETY LIMIT LIGHT OPERATION,
BEFORE THE POWER BUTTON HAS BEEN CYCLED ON/OFF:
Watch the safety limit lights on the control board:
• SL#1 flashes = 3 or more 45 minute cycles
• SL#1 continuously on = Six 45minute freeze cycles
• SL#1 & SL#2 flash = SL#3, neither float opened within
4 minutes of the freeze cycle.
CONTROL BOARD SAFETY LIMIT LIGHT OPERATION
USING THE POWER BUTTON:
1. Press the power button once.
2. Press the power button again to start ice making.
3. Watch the safety limit lights.
• One will flash corresponding to safety limits 1
or2.
4. Safety limit 3 is indicated by both SL#1 & SL#2
flashing.
After safety limit indication, the ice machine will restart
and run until a safety limit is exceeded again.
Safety Limit Notes
• A continuous run of 100 harvests automatically erases
the safety limit code.
• The control board will store and indicate only one
safety limit – the last one exceeded.
• If the power button is cycled OFF and then ON prior
to reaching the 100-harvest point, the last safety limit
exceeded will be indicated.
Part Number STH042 7/15 73
Safety Limit Checklist
The following checklists are designed to assist the service
technician in analysis. However, because there are many
possible external problems, do not limit your diagnosis to
only the items listed.
Safety Limit #1
Freeze time exceeds 45 minutes for 3 consecutive
freeze cycles.
Possible Cause Checklist
Improper installation
• Refer to “Installation/Visual Inspection Checklist” on
page 67
Water System
• Water Level too high or defective float switch (water
escaping water trough)
• Low water pressure (20 psig min.)
• High water pressure (80 psig max.)
• High water temperature (90°F/32.2°C max.)
• Clogged water distribution tube
• Dirty/defective water inlet valve
• Defective water pump
Electrical System
• Harvest cycle not initiated electrically
• Contactor not energizing
• Compressor electrically non-operational
• Restricted condenser air flow
• High inlet air temperature (110°F/43.3°C max.)
• Condenser discharge air re-circulation
• Dirty condenser fins
• Defective fan cycling control
• Defective fan motor
• Low water pressure (20 psig min.)
• High water temperature (90°F/32.2°C max.)
• Dirty condenser
74 Part Number STH042 7/15
Refrigeration System
• Non-Manitowoc components
• Improper refrigerant charge
• Defective compressor
• TXV starving or flooding (check bulb mounting)
• Non-condensible in refrigeration system
• Plugged or restricted high side refrigerant lines or
component
• Defective harvest valve
Part Number STH042 7/15 75
Safety Limit #2
Harvest time exceeds 3.5 minutes for 3 Consecutive
harvest cycles.
Possible Cause Checklist
Improper installation
• Refer to “Installation/Visual Inspection Checklist” on
page 67
Water System
• Water area (evaporator) dirty
• Dirty/defective water dump valve
• Vent tube not installed on water outlet drain
• Water freezing behind evaporator
• Plastic extrusions and gaskets not securely mounted
to the evaporator
• Low water pressure (20 psig min.)
• Loss of water from sump area
• Clogged water distribution tube
• Dirty/defective water inlet valve
• Defective water pump
Electrical system
• Water inlet valve defective
• Bin switch defective
• Premature harvest
Refrigeration system
• Non-Manitowoc components
• Improper refrigerant charge
• Defective harvest valve
• TXV flooding (check bulb mounting)
• Defective fan cycling control
76 Part Number STH042 7/15
Safety Limit 3
Freeze time reaches 4 minutes and water is not
sensed.
Possible Cause Checklist
Improper installation
• Refer to “Installation/Visual Inspection Checklist” on
page 67
Water System
• Dirty/defective water dump valve
• Low water float valve dirty or defective
• Vent tube not installed on water outlet drain
• Low water pressure (20 psig min.)
• Dirty defective water filter (when used)
• Loss of water from sump area
• Dirty/defective water inlet valve
Electrical system
• Water inlet valve coil defective
• Low water float valve defective
Part Number STH042 7/15 77
Analyzing Discharge Pressure
1. Determine the ice machine operating conditions:
Air temp. entering condenser ______
Air temp. around ice machine ______
Water temp. entering sump trough ______
2. Refer to “Cycle Times, 24 Hr. Ice Production and
Refrigerant Pressure Charts” on page 123 for ice
machine being checked.
Use the operating conditions determined in step 1 to find
the published normal discharge pressures.
Freeze Cycle ______
Harvest Cycle ______
3. Perform an actual discharge pressure check.
Freeze Cycle
PSIG
Beginning of
Cycle____________________
Middle of
Cycle____________________
End of
Cycle____________________
4. Compare the actual discharge pressure (Step 3) with
the published discharge pressure (Step 2).
The discharge pressure is normal when the actual
pressure falls within the published pressure range for the
ice machine’s operating conditions. It is normal for the
discharge pressure to be higher at the beginning of the
freeze cycle (when load is greatest), then drop through
out the freeze cycle.
Harvest Cycle
PSIG
78 Part Number STH042 7/15
Discharge Pressure High Checklist
Improper Installation
• Refer to “Installation/Visual Inspection Checklist” on
page 67
Restricted Condenser Air Flow
• High inlet air temperature
• Condenser discharge air re-circulation
• Dirty condenser fins
• Defective fan cycling control
• Defective fan motor
Improper Refrigerant Charge
• Overcharged
• Non-condensable in system
• Wrong type of refrigerant
Other
• Non-Manitowoc components in system
• High side refrigerant lines/component restricted
(before mid-condenser)
Freeze Cycle Discharge Pressure Low Checklist
Improper Installation
• Refer to “Installation/Visual Inspection Checklist” on
page 67
Improper Refrigerant Charge
• Undercharged
• Wrong type of refrigerant
Other
• Non-Manitowoc components in system
• High side refrigerant lines/component restricted
(before mid-condenser)
• Defective fan cycle control
NOTE: Do not limit your diagnosis to only the items listed
in the checklists.
Part Number STH042 7/15 79
Analyzing Suction Pressure
The suction pressure gradually drops throughout the
freeze cycle. The actual suction pressure (and drop rate)
changes as the air and water temperature entering the
ice machine changes. These variables also determine the
freeze cycle times.
To analyze and identify the proper suction pressure drop
throughout the freeze cycle, compare the published
suction pressure to the published freeze cycle time.
NOTE: Analyze discharge pressure before analyzing
suction pressure. High or low discharge pressure may be
causing high or low suction pressure.
80 Part Number STH042 7/15
Procedure
Step
1. Determine the ice machine operating conditions.
Example:
Air temp. entering condenser: 90°F/32.2°C
Air temp. around ice machine: 80°F/26.7°C
Water temp. entering water fill valve: 70°F/21.1°C
2A. Refer to “Cycle Time” and “Operating Pressure” charts for ice
machine model being checked. Using operating conditions
from Step 1, determine published freeze cycle time and
published freeze cycle suction pressure.
Example:
Published freeze cycle time: 14.8 - 15.9 minutes
Published freeze cycle suction pressure: 65 - 26 psig
2B. Compare the published freeze cycle time and published
freeze cycle suction pressure. Develop a chart.
Published Freeze Cycle Suction Pressure (psig)
In the example, the proper suction pressure should be
approximately 39 psig at 7 minutes; 30 psig at 12 minutes; etc.
3. Perform an actual suction pressure check at the beginning,
middle and end of the freeze cycle. Note the times at which the
readings are taken.
Example:
Manifold gauges were connected to the example ice machine
and suction pressure readings taken as follows: ________ PSIG
Beginning of freeze cycle: 79 (at 1 min.)
Middle of freeze cycle: 48 (at 7 min.)
End of freeze cycle: 40 (at 14 min.)
4. Compare the actual freeze cycle suction pressure (Step 3)
to the published freeze cycle time and pressure comparison
(Step2B). Determine if the suction pressure is high, low or
acceptable.
Example:
In this example, the suction pressure is considered high
throughout the freeze cycle. It should have been:
Approximately 65 psig (at 1 minute) – not 79
Approximately 39 psig (at 7 minutes) – not 48
Approximately 26 psig (at 14 minutes) – not 40
Part Number STH042 7/15 81
Suction Pressure High Checklist
Improper Installation
• Refer to “Installation/Visual Inspection Checklist” on
page 67
Discharge Pressure
• Discharge pressure is too high, and is affecting
suction pressure, refer to “Discharge Pressure High
Checklist” on page 79.
Improper Refrigerant Charge
• Overcharged
• Wrong type of refrigerant
• Non-condensable in system
Other
• Non-Manitowoc components in system
• Harvest valve leaking
• TXV flooding (check bulb mounting)
• Defective compressor
82 Part Number STH042 7/15
Suction Pressure Low Checklist
Improper Installation
• Refer to “Installation/Visual Inspection Checklist” on
page 67
Discharge Pressure
• Discharge pressure is too low, and is affecting suction
pressure, refer to “Freeze Cycle Discharge Pressure
Low Checklist” on page 79.
Improper Refrigerant Charge
• Undercharged
• Wrong type of refrigerant
Other
• Non-Manitowoc components in system
• Improper water supply over evaporator refer to
”Water System Checklist” on page 68.
• Loss of heat transfer from tubing on back side of
evaporator
• Restricted/plugged liquid line drier
• Restricted/plugged tubing in suction side of
refrigeration system
• TXV starving
NOTE: Do not limit your diagnosis to only the items listed
in the checklists.
Part Number STH042 7/15 83
Harvest Valve
General
The harvest valve is an electrically operated valve that
opens when energized, and closes when de-energized.
Normal Operation
The valve is de-energized (closed) during the freeze cycle
and energized (open) during the harvest cycle. The valve
is positioned between the receiver and the evaporator
and performs two functions:
1. Prevents refrigerant from entering the evaporator
during the freeze cycle.
The harvest valve is not used during the freeze
cycle. The harvest valve is de-energized (closed)
preventing refrigerant flow from the receiver into
the evaporator.
2. Allows refrigerant vapor to enter the evaporator in
the harvest cycle.
During the harvest cycle, the harvest valve is
energized (open) allowing refrigerant gas from the
discharge line of the compressor to flow into the
evaporator. The heat is absorbed by the evaporator
and allows release of the ice slab.
Exact pressures vary according to ambient temperature
and ice machine model. Harvest pressures can be found
in the Cycle Time/24 Hour Ice Production/ Refrigerant
Pressure Charts in this book.
84 Part Number STH042 7/15
Harvest Valve Analysis
The valve can fail in two positions:
• Valve will not open in the harvest cycle.
• Valve remains open during the freeze cycle.
VALVE WILL NOT OPEN IN THE HARVEST CYCLE
Although the circuit board has initiated a harvest cycle,
the evaporator temperature remains unchanged from the
freeze cycle.
VALVE REMAINS OPEN IN THE FREEZE CYCLE:
Symptoms of a harvest valve remaining partially open
during the freeze cycle can be similar to symptoms of
an expansion valve, float valve or compressor problem.
Symptoms are dependent on the amount of leakage in
the freeze cycle.
A small amount of leakage will cause increased freeze
times and an ice fill pattern that is “Thin at the Outlet”, but
fills in at the end of the cycle.
As the amount of leakage increases the length of the
freeze cycle increases and the amount of ice at the outlet
of the evaporator decreases.
Refer to the Parts Manual for proper valve application. If
replacement is necessary, use only “original” Manitowoc
replacement parts.
Part Number STH042 7/15 85
Use the following procedure and table to help determine
if a harvest valve is remaining partially open during the
freeze cycle.
1. Wait five minutes into the freeze cycle.
2. Feel the inlet of the harvest valve(s).
Important
Feeling the harvest valve outlet or across the harvest
valve itself will not work for this comparison.
The harvest valve outlet is on the suction side (cool
refrigerant). It may be cool enough to touch even if
the valve is leaking.
3. Feel the compressor discharge line.
Warning
The inlet of the harvest valve and the compressor
discharge line could be hot enough to burn your
hand. Just touch them momentarily.
4. Compare the temperature of the inlet of the harvest
valves to the temperature of the compressor
discharge line.
86 Part Number STH042 7/15
FindingsComments
The inlet of the harvest
valve is cool enough to
touch and the compressor
discharge line is hot.
Cool & Hot
The inlet of the harvest
valve is hot and approaches
the temperature of a hot
compressor discharge line.
Hot & Hot
Both the inlet of the harvest
valve and the compressor
discharge line are cool
enough to touch.
Cool & Cool
This is normal as the discharge
line should always be too hot to
touch and the harvest valve inlet,
although too hot to touch during
harvest, should be cool enough
to touch after 5 minutes into the
This is an indication something is
wrong, as the harvest valve inlet
did not cool down during the
freeze cycle. If the compressor
dome is also entirely hot, the
problem is not a harvest valve
leaking, but rather something
causing the compressor (and the
entire ice machine) to get hot.
This is an indication something is
wrong, causing the compressor
discharge line to be cool to the
touch. This is not caused by a
harvest valve leaking.
5. Record your findings on the table.
freeze cycle.
Part Number STH042 7/15 87
Comparing Evaporator Inlet/Outlet
Temperatures
The temperatures of the suction lines entering and
leaving the evaporator alone cannot diagnose an ice
machine. However, comparing these temperatures
during the freeze cycle, along with using Manitowoc’s
Refrigeration System Operational Analysis Table, can help
diagnose an ice machine malfunction.
The actual temperatures entering and leaving the
evaporator vary by model, and change throughout
the freeze cycle. This makes documenting the “normal”
inlet and outlet temperature readings difficult. The key
to the diagnosis lies in the difference between the two
temperatures five minutes into the freeze cycle. These
temperatures must be within 7°F (4°C) of each other.
Use this procedure to document freeze cycle inlet and
outlet temperatures.
1. Use a quality temperature meter, capable of taking
temperature readings on curved copper lines.
2. Attach the temperature meter sensing device to the
copper lines entering and leaving the evaporator.
Important
Do not simply insert the sensing device under the
insulation. It must be attached to and reading the
actual temperature of the copper line.
3. Wait five minutes into the freeze cycle.
4. Record the temperatures below and determine the
difference between them.
_________________________________
Inlet
Temperature
Difference must be within
7°F (4°C) at 5minutes into
the freeze cycle
Outlet
Temperature
5. Use this with other information gathered on the
Refrigeration System Operational Analysis Table to
determine the ice machine malfunction.
88 Part Number STH042 7/15
Discharge Line Temperature Analysis
GENERAL
Knowing if the discharge line temperature is
increasing, decreasing or remaining constant can be
an important diagnostic tool. Maximum compressor
discharge line temperature on a normally operating
ice machine steadily increases throughout the freeze
cycle. Comparing the temperatures over several cycles
will result in a consistent maximum discharge line
temperature.
Ambient air temperatures affect the maximum discharge
line temperature.
Higher ambient air temperatures at the condenser =
higher discharge line temperatures at the compressor.
Lower ambient air temperatures at the condenser = lower
discharge line temperatures at the compressor.
Regardless of ambient temperature, the freeze cycle
discharge line temperature will be higher than 150°F
(66°C) on a normally operating ice machine.
PROCEDURE
Connect a temperature probe on the compressor
discharge line within 6" (15.2 cm) of the compressor.
Observe the discharge line temperature for the last three
minutes of the freeze cycle and record the maximum
discharge line temperature.
Part Number STH042 7/15 89
Discharge Line Temperature Above 150°F (66°C) at
End of Freeze Cycle:
Ice machines that are operating normally will have
consistent maximum discharge line temperatures above
150°F (66°C).
Verify the expansion valve sensing bulb is positioned and
secured correctly.
Discharge Line Temperature Below 150°F (66°C) at
End of Freeze Cycle
Ice machines that have a flooding expansion valve
will have a maximum discharge line temperature that
decreases each cycle.
Verify the expansion valve sensing bulb is 100% insulated
and sealed airtight. Condenser air contacting an
incorrectly insulated sensing bulb will cause overfeeding
of the expansion valve.
90 Part Number STH042 7/15
Refrigeration Component Diagnostics
All electrical and water related problems must be
corrected before these charts will work properly. These
tables must be used with charts, checklists and other
references to eliminate refrigeration components not
listed and external items and problems that will cause
good refrigeration components to appear defective.
The tables list four different defects that may affect the
ice machine’s operation.
NOTE: A low-on-charge ice machine and a starving
expansion valve have very similar characteristics and are
listed under the same column.
Part Number STH042 7/15 91
PROCEDURE
Step 1 Complete each item individually in the
“Operational Analysis” column.
Enter check marks () in the boxes.
Each time the actual findings of an item in the
“Operational Analysis” column matches the published
findings on the table, enter a check mark.
Example: Freeze cycle suction pressure is determined to
be low. Enter a check mark in the “low” box.
Perform the procedures and check all information listed.
Each item in this column has supporting reference
material.
While analyzing each item separately, you may find an
“external problem” causing a good refrigerant component
to appear bad. Correct problems as they are found. If
the operational problem is found, it is not necessary
to complete the remaining procedures.
Step 2 Add the check marks listed under each of the
four columns. Note the column number with the highest
total and proceed to “Final Analysis.”
NOTE: If two columns have matching high numbers,
a procedure was not performed properly and/or
supporting material was not analyzed correctly.
92 Part Number STH042 7/15
FINAL ANALYSIS
The column with the highest number of check marks
identifies the refrigeration problem.
Column 1 – Harvest Valve Leaking
A leaking harvest valve must be replaced.
Column 2 – Low Charge/TXV Starving
Normally, a starving expansion valve only affects the
freeze cycle pressures, not the harvest cycle pressures. A
low refrigerant charge normally affects both pressures.
Verify the ice machine is not low on charge before
replacing an expansion valve.
Add refrigerant charge in 2 oz. increments as a diagnostic
procedure to verify a low charge. (Do not add more
than the total charge of refrigerant). If the problem is
corrected, the ice machine is low on charge. Find the
refrigerant leak.
The ice machine must operate with the nameplate
charge. If the leak cannot be found, proper refrigerant
procedures must still be followed. Change the liquid
line drier, evacuate the system and weigh in the proper
charge.
If the problem is not corrected by adding charge, the
expansion valve is faulty.
Column 3 – TXV Flooding
A loose or improperly mounted expansion valve
bulb causes the expansion valve to flood. Check bulb
mounting, insulation, etc., before changing the valve.
Column 4 – Compressor
Replace the compressor and start components. To
receive warranty credit, the compressor ports must be
properly sealed by crimping and soldering them closed.
Old start components must be returned with the faulty
compressor.
All installation and water related problems must be corrected
NOTE: The ice machine is operating properly if the ice fill pattern is normal and ice production is within
Installation and Water
-or-
Ice formation is normal
before proceeding with chart.
Ice formation is
extremely thin on outlet
extremely thin on outlet
System
Ice Formation Pattern Ice formation is
-or-
Ice formation is
of evaporator
of evaporator
No ice formation on
extremely thin on the
bottom of evaporator
-or-
entire evaporator
No ice formation on
-or-
entire evaporator
No ice formation on
REFRIGERATION COMPONENT DIAGNOSTIC CHART
94 Part Number STH042 7/15
evaporator
1
High
Stops on safety limit:
1 or 2
Stops on safety limit:
1
Stops on safety limit:
1 or 2
Stops on safety limit:
checklist to eliminate problems and/or components not listed on this table before proceeding.
If discharge pressure is High or Low, refer to freeze cycle high or low discharge pressure problem
Suction pressure is
High
Suction pressure is
Low
Suction pressure is
eliminate problems and/or components not listed on this table before proceeding.
If suction pressure is High or Low refer to freeze cycle high or low suction pressure problem checklist to
High
Suction pressure is
Safety Limits
Operational Analysis1234
Part Number STH042 7/15 95
Refer to “Analyzing Safety
Limits” to eliminate all non-
Freeze Cycle
refrigeration problems.
DischargePressure
________ ______ ______
Freeze Cycle
SuctionPressure
1 minute Middle End
________ ______ ______
1 minute Middle End
The harvest valve
The harvest valve
COOL
inlet is
COOL
inlet is
and
and
The compressor
discharge line is
discharge line is
The compressor
HOT
COOL
Discharge line temp
Discharge line temp
150°F (66°C) or higher
at the end of freeze cycle
TXV FloodingCompressor
less than 150°F (66°C)
at the end of freeze cycle
Low On Charge
Final Analysis
Harvest Valve
-or-
Leaking
Enter total number of boxes
TXV Starving
checked in each column.
and
COOL
inlet is
The harvest valve
and
HOT
inlet is
The harvest valve
Harvest Valve
Operational Analysis1234
96 Part Number STH042 7/15
The compressor
discharge line is
discharge line is
The compressor
HOT
Discharge line temp
150°F (66°C) or higher
at the end of freeze cycle
HOT
Discharge line temp
150°F (66°C) or higher
at the end of freeze cycle
end of freeze cycle.
Record freeze cycle
Discharge Line Temp.
discharge line temp at the
Component Check Procedures
Main Fuse
Function
The control board fuse stops ice machine operation if
electrical components fail causing high amp draw.
Specifications
• The main fuse is 250 Volt, 10 amp.
Warning
High (line) voltage is applied to the control board
at all times. Removing the control board fuse or
pressing the power button will not remove the power
supplied to the control board.
Check Procedure
1. If the curtain light is on with the ice damper closed,
the fuse is good.
Warning
Disconnect electrical power to the entire ice machine
before proceeding.
2. Remove the fuse. Check the resistance across the
fuse with an ohmmeter.
ReadingResult
Open (OL)Replace fuse
Closed (O)Fuse is good
Part Number STH042 7/15 97
Bin Switch
Function
Bin switch operation is controlled by the movement of
the ice damper. The bin switch has two main functions:
1. Terminating the harvest cycle and returning the ice
machine to the freeze cycle.
This occurs when the bin switch is opened and
closed again within 7 seconds of opening during the
harvest cycle.
2. Automatic ice machine shut-off.
If the storage bin is full at the end of a harvest cycle,
the sheet of cubes fails to clear the ice damper and
holds it down. After the ice damper is held down for
7 seconds, the ice machine shuts off.
The ice machine remains off until enough ice is
removed from the storage bin to allow the sheet
of cubes to drop clear of the ice damper. As the ice
damper swings back to the operating position, the
bin switch closes and the ice machine restarts.
Important
The ice damper must be up (bin switch closed) to
start ice making.
Check Procedure
1. Press the power button to OFF.
2. Watch the curtain light on the control board.
3. Move the ice damper upward, toward the
evaporator. The bin switch must close. The curtain
light “on” indicates the bin switch has closed
properly.
4. Move the ice damper away from the evaporator. The
bin switch must open. The curtain light “off” indicates
the bin switch has opened properly.
98 Part Number STH042 7/15
Ohm Test
1. Disconnect the bin switch wires to isolate the bin
switch from the control board.
2. Connect an ohmmeter to the disconnected bin
switch wires.
3. Cycle the bin switch open and closed numerous
times by opening and closing the water curtain.
NOTE: To prevent misdiagnosis:
• Always use the water curtain magnet to cycle the
switch (a larger or smaller magnet will affect switch
operation).
• Watch for consistent readings when the bin switch is
cycled open and closed (bin switch failure could be
erratic).
Part Number STH042 7/15 99
Touch Pad
Function
User interface to select ice making, delay start or cleaning
cycle and provides feedback on ice machine operation.
Check For Normal Operation
ActionNormal Function
Press and hold the control
board test button for
3seconds
Press test buttonAll Touch Pad lights turn off
Press power buttonPower light turns on
With power light energized
press the delay button 4 times
Press and hold the power
button for 3 seconds
Press and hold the clean
button for 3 seconds
Press and hold the clean
button for 3 seconds
If any switches do not operate correctly, disconnect main power
to the ice machine to reset the control board and perform a
second test. If the second test doesn’t show normal function,
perform the Ohm test to verify the issue is not a wiring or