Manitowoc Ice Q-DUAL User Manual

TROUGH AND PROTECTOR ASSEMBL Y
Q-DUAL SERIES - 4004489
Installation Instructions
1. Remove front panel assembly.
2. Remove splash shield.
4. If the machine is already equipped with trough protectors, use existing holes to attach. If not, continue with steps
5-10.
5. Position trough protectors over the rear edge of the trough, centering the guard between the arms of the sump (see
Figure 1 and 2).
6. Mark the screw position on the back bulkhead for each trough protector.
7. Remove the trough protectors.
8. Drill one 5/32” [3.9mm] diameter hole through the back bulkhead for each protector on the marks made in step 6.
9. Reposition the trough protectors as in step 5.
10. Drive the #10 hex head screws through each bracket into the holes made in step 8.
11. Replace the splash shield.
12. Replace the front panel assembly.
Drill 5/32”
hole in back Trough Protector Q-DUAL
Manitowoc Ice, Inc.
2110 South 26th Street, P.O. Box 1720, Manitowoc, WI 54221-1720 USA Telephone 920-682-0161, Fax - Sales: 920-683-7589, Service/Parts: 920-683-7585, Other: 920-683-7879 8006713 Web Site - www.manitowocice.com Rev. 06/17/03
Figure 1
Figure 2
bulkhead for #10 screw