Manitowoc Ice MDB-290 User Manual

MDB-290 WATERPROOF SWITCH/ACTUATING ARM
REPLACEMENT KIT
Installation Instructions
A. Disconnect power to dispenser. B. Remove top panel. C. Remove front panel. Wing nuts on inside of ice chute
must be loosened to pull front panel away from dispenser.
hold activating arm.
E. Remove switch box and gasket. Disconnect leads. F. Lead wire terminals must be removed and butt connectors
in the kit attached.
G. Lead wires in conduit will require connection to micro
switch. Existing eyelet terminals to be cut off - strip wires 5/16” for attaching butt connectors (item 9) to lead
The MDB-290 Waterproof Switch/Actuating Arm Replacement Kit includes:
Qty. Description Part Number
Item 1 1 Waterproof Switch/Bracket Assy. 7623283 2 1 Pivot Block/Actuating Arm Assy. 7623293 3 1 Switch Box 6595814 4 1 Mylar Screen Assy. 6192114 5 1 Pin 5013183 6 1 Bushing 2500143 7 2 #8-32 Hex Nut 5429061 8 2 Lock Washer 5544591 9 4 Flat Washer 5504261 10 1 Poly Bag 7200631 11 1 Padded Bag 7201093 12 1 Installation Instructions 8003803
If this switch is being installed on a dispenser that does not have a mechanical or mercury relay to carry the gear motor load, a relay of sufficient size must be added. Note switch is not rated for gear motor amps.
: If switch replacement is required after the installation
Note
of this kit, order Waterproof Switch/Bracket Assy.,
7623283.
Manitowoc Ice, Inc.
2110 South 26 Street, P.O. Box 1720, Manitowoc, WI 54221-1720 USA Telephone 920-682-0161, Fax - Sales: 920-683-7589, Service/Parts: 920-683-7585, Other: 920-683-7879 8003803 Web Site - www.manitowocice.com Rev. 01/13/00
: Mounting screws also
: This
wires of switch. Note required to insure the conduit is long enough to reach the new switch box on some machines. 90 conduit connector not furnished with this kit.
H. Attach mylar screen assembly with double-face tape. I. Attach new spring loaded activating arm assembly. J. Adjust switch by sliding switch bracket forward or
backward while activating the dispensing arm until the switch is positioned so that it makes (closes) just before the arm bottoms out against the front panel. This will assure that undue pressure is not put on the switch.
: A 90 conduit connector might be
Loading...