SAFETY INFORMATION
DO NOT INSTALL AN APPLI­ANCE IN THIS FIREBOX, UN­LESS THIS FIREBOX MEETS THE MINIMUM DIMENSIONS REQUIRED FOR THE INSTALLA­TION.
WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property dam­age, personal injury or loss of life.
FOR USE ONLY WITH A LISTED, GAS-FIRED, UNVENTED, DECO­RATIVE ROOM HEATER NOT TO EXCEED 40,000 BTU/H.
DO NOT BUILD A WOOD FIRE.
DUE TO HIGH TEMPERATURES, THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES.
Ventless Fireboxes Models: UVSRC36
UVSRC42
Do not attempt to modify or alter the construction of the appliance or its components. Any modifica­tion or alteration of construction may void the warranty of these units.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. Improper service or maintenance can cause injury or property damage. Refer to this manual. For assistance or addi­tional information, consult a qualified installer, service agency or the gas supplier.
Carefully review the instructions supplied with the decorative type unvented room heater for the minimum fireplace size require­ment.
Homeowner's Installation
and Operating Manual
These Ventless Fireboxes are design certified to ANSI 21.91.2001, and are for use with any ANSI Z21.11.2a Unvented Room Heaters.
CFM Specialty Home Products
410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777
www.majesticproducts.com • www.vermontcastings.com
C
E
2068
I
S
G
E
N
D
D
R
E
I
T
I
F
INSTALLER: DO NOT DISCARD THIS MANUAL - Leave in fireplace for homeowner.
20002068 2/04 Rev. 10
UVSRC Series Fireboxes
Description
The UVSRC models are ventless fireboxes designed for installation with any ventless gas log set certified to ANSI Z21.11.2a standards. Each model comes with a choice of optional hoods. Hood types may be used depending on the combustible mantel clearance above and in front of the firebox. (See the Accessories on Page 12 for details.)
Available Models:
UVSRC36 - Radiant Circulating Model UVSRC42 - Radiant Circulating Model
For Your Safety
Do not place clothing or other flammable material on or near the appliance. Children and adults should be alerted to the hazards of high surface temperatures and should stay away to
avoid burns or clothing ignition. Young children should be carefully supervised when they are in the same room as the appliance.
Table of Contents
Description and Available Models .................... 2
Specifications and Framing...............................3
General Information .......................................... 4
Clearances ........................................................ 5
Installation ......................................................... 6
Maintenance....................................................10
Replacement Parts.......................................... 11
Accessories..................................................... 12
2
20002068
¹⁄₂"
47"
UVSRC36 Series Firebox Specifications
Rough
⁵⁄₈"
Opening Depth
22¹⁄₂"
22"
24"
19³⁄₄"
UVSRC Series Firebox
18¹⁄₂"
33³⁄₄"
47"
66¹⁄₄"
¹⁄₂"
38"
Outside Air
Gas Line Access
Electrical Access
7¹⁄₂"
6³⁄₄"
10⁵⁄₈"
Rough Opening Height
14"
9⁵⁄₈"
3"
Rough Opening Width 41"
38¹⁄₂"
Fig. 1 UVSRC36 Series Firebox specifications and framing dimensions.
UVSRC42 Series Firebox Specifications
Rough Opening Depth
50"
33¹⁄₄"
36"
40"
26¹⁄₄"
⁵⁄₈" Recessed Nailing Flange
7¹⁄₂"
23"
7¹⁄₂"
Gas Line Access
9⁵⁄₈"
10⁵⁄₈"
FP605a
7¹⁄₂"
6³⁄₄"
10⁵⁄₈"
22¹⁄₂"
Rough Opening Height
9⁵⁄₈"
3"
22"
Rough Opening Width 47"
38¹⁄₂"
14"
50"
¹⁄₂"
¹⁄₂"
Gas Line Access
36"
Outside Air
⁵⁄₈"
70¹⁄₂"
38"
Electrical Access
Fig. 2 UVSRC42 Series Firebox specifications and framing dimensions.
20002068
42"
46"
⁵⁄₈" Recessed Nailing Flange
7¹⁄₂"
23"
7¹⁄₂"
Gas Line Access
9⁵⁄₈"
10⁵⁄₈"
FP605b
3
UVSRC Series Fireboxes
General Information
DO NOT BURN WOOD OR OTHER MATERIALS IN THESE FIREBOXES.
General Information
The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1 (latest edition) and with the Na­tional Electrical Code, ANSI/NFPA70 (latest edition).
NOTE: Installation and repair should be done by a qualified service person. The firebox should be in­spected before use and at least annually by a qualified service person. More frequent cleaning may be re­quired due to excessive lint from carpeting, bedding material, etc. It is imperative that control compartment, burners, and circulating air passageways of the firebox be kept clean.
Any safety screen or guard removed for servicing a firebox must be replaced prior to operating the firebox.
Provide adequate combustion and ventilation air. The flow of combustion and ventilation air MUST NOT
be obstructed. Provide adequate clearance around air openings into
the combustion chamber and adequate accessibility clearance for servicing and proper operation. NEVER obstruct the front opening of the firebox.
These models MAY NOT be installed in OEM mobile homes.
These models MAY BE installed in a bedroom provided the logset installed in the unit is certified and rated at 10,000 BTU's or less.
These models MAY NOT be installed in a bathroom. Glass doors are NOT to be used on these fireboxes.
Installation Precautions
This CFM Specialty Home Products firebox and its components have been tested and will operate safely when installed in accordance with this installation Manual. Read all instructions before starting installa­tion, then follow these instructions carefully during installation to maximize firebox benefit and safety.
Report to your dealer any parts damaged in shipment. This firebox is a highly engineered system. Unless you
use CFM Corporation components which have been designed for the system, you may create a possible fire hazard.
CFM Specialty Home Products warranty will be voided by, and CFM Specialty Home Products disclaims any responsibility for, the following actions:
• Installation of any damaged firebox.
• Modification of the firebox or any of the component parts thereof.
• Installation other than as instructed by CFM Specialty Home Products
• Installation and/or use of any component part or accessory not manufactured or approved by CFM Specialty Home Products in combina­tion or assembly with a Majestic Fireplaces firebox, notwithstanding any independent testing laboratory or other third party ap­proval of such component part or accessory.
Any such action may create a possible fire hazard. Consult your local building codes.
Proposition 65 Warning: Fuels used in gas, woodburning or oil fired appliances, and the products of combustion of such fuels, contain chemicals known to the State of California to cause cancer, birth defects and other reproductive harm. California Health & Safety Code Sec. 25249.6
Fireplace Screen
The fireplace screen must be in place when the firebox is operating, and unless other provisions for combustion air are made, the screen must have openings for the
introduction for combustion air.
WARNING: Be sure to read complete
Vent-Free Gas Log Heater and Vent-Free Fireplace Installation and Operating Instructions before installing this prod-
uct.
4
20002068
UVSRC Series Firebox
3a UVSRC w/2" Hood
Ceiling
42"
3b
A
11" Min.
Combustible Perpendicular Wall
Front View
Drywall
Front View
8"
Mantel Shelf
¹⁄₂"
F
B
Standoff
Side View
C
2" Hood
Seal with noncombustible material
Side View
Fig. 3 Clearances to combustibles.
Clearances
Sidewall Clearances:
The clearance from the side of the firebox to any combustible wall extending in front of the unit should
not be less than 11". (Fig. 3)
Back Wall Clearances:
Standoff
UVSRC w/ 4" Hood
Ceiling
42"
A
11" Min.
Combustible Perpendicular Wall
Drywall
8"
Mantel Shelf
¹⁄₂"
F
D
E
4" Hood (Includes Glass Hood)
Seal with noncombustible material
Finished Wall Combustible
Combustible Mantel Trim Leg
2"
3¹⁄₄" 3¹⁄₄"
Noncombustible Facing Material
Dim. UVSRC36 UVSRC42
A 36" 42" B 17" 20" C 12" 16¹⁄₂" D 14" 15" E8³⁄₄"11" F1¹⁄₂" max. 1¹⁄₂" max.
FP604a
Mantel Trim Leg
Firebox
6"
8"
The firebox may be placed against a combustible back wall.
Ceiling Clearances:
The ceiling height should not be less than 42" from the top of the fireplace opening. (Fig. 3)
Mantel Clearances:
A 4" hood is furnished with each model firebox. This hood MUST BE INSTALLED before using the firebox, if a mantel falls within the dimensions and locations shown in Figure 3. Refer to Accessories on Page 13.
If a combustible mantel or breast plate is installed, it must meet the clearance requirements detailed in Figure 3. If using a mantel with trim leg, maintain clearances detailed in Figure 4.
20002068
Hood
Front Edge of Grate
3"
FP604b
Fig. 4 Clearances to combustibles.
NOTE: When installing an ANSI Z21.11.2a ventless
appliance, the finishing material used for the mantel must be rated at 250°F or greater.
Grate Clearance:
The minimum clearance between the front legs of the grate and front edge of the fireplace is 3”. (Fig. 4)