INSTALLER/CONSUMER
SAFETY INFORMATION
Read and save
these instructions.
This book contains your installation
instructions and should be kept in a
safe place. For you to realize all the
advantages and use of the reliable
service that has been engineered into
your Temco fireplace, you must carefully follow all of the instructions contained in this book regarding installation
and operation of the fireplace.
These instructions should be read
carefully in their entirety before beginning installation of the fireplace.
It is suggested that you wear work
gloves and safety glasses to protect
your hands and eyes when installing
your fireplace. NOTE: Authorities
having jurisdiction (i.e. building inspectors, fire marshals, etc.) should be
consulted before installation to determine the need to obtain a permit.
When installing the Blower Kit, it is
necessary to bring the power source to
the fireplace before walls are enclosed.
Refer to Blower Kit instructions.
These fireboxes are approved as
universal fireboxes and can be
paired with any ANSI Z21.11.2 approved vent-free log set. The ventfree log manufacturer’s instructions including their required dimensional
clearances for firebox size, - must be
followed.
Refer to the manual that is packed with
the log set for operating instructions.
“
Vent-Free Firebox
Models: UVSRC36A
UVSRC42A
Homeowner’s Installation and
Operating Manual
CFM Specialty Home Products
410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777
www.majesticproducts.com • www.vermontcastings.com
INSTALLER DO NOT DISCARD THIS MANUAL - Leave in Fireplace for Homeowner
20007435 6/04 Rev. 1
UVSRC Vent-Free Fireboxes
Fireplace Dimensions ...................................................................................................................3
Installation Instructions................................................................................................................4
Choosing a location............................................................................................................4
Gas line ..............................................................................................................................4
Drafts..................................................................................................................................4
Fireplace Clearances .........................................................................................................4
Installing the Firebox ..........................................................................................................5
Finishing the Fireplace .......................................................................................................7
Hearth Extension................................................................................................................7
Pre-Wiring of Junction Box.................................................................................................7
Electrical Services..............................................................................................................7
BL-4 Blower Installation .....................................................................................................7
UVSRC36A Installation ......................................................................................................8
UVSRC42A Installation ......................................................................................................8
Servicing ........................................................................................................................................9
Replacement Parts......................................................................................................................10
Accessories .................................................................................................................................10
Warranty.......................................................................................................................................11
Table of Contents
UVSRC36A, UVSRC42A
Certified To
ANSI Z 21.91.2001
Ventless Fireboxes
for use with
any ANSI Z21.11.2
Unvented Room Heaters
2
20007435
Fireplace Dimensions
UVSRC Vent-Free Fireboxes
Rough
Opening
S
R
S
Q
1/2” Clearance
to
Combustibles
not Required at
this Point
Gas Line
Access
Depth
O
J
1/2” Clearance to
Combustibles not
Required at this Point
Rough
Opening
Height
G
K
I
Rough Opening Width C
Fig. 1 UVSRC36A and UVSRC42A specifications and framing dimensions.
N
1/2"
F
A
C
B
D
UVSRC36A UVSRC42A
A 36” 42”
B27³⁄₄”27³⁄₄”
C39¹⁄₄”45¹⁄₄”
D7” 7”
F 41” 41”
G44¹⁄₄”44¹⁄₄”
I9⁷⁄₈”9⁷⁄₈”
J 21” 22”
K8¹⁄₈”8¹⁄₈”
N 22” 32”
O 21” 22”
Q 65” 76”
R32¹⁄₂” 38”
S 46” 53³⁄₄”
20007435
3
UVSRC Vent-Free Fireboxes
Installation Instructions
Choosing the Location for Your Fireplace
Figure 1 shows some of the many ways your fireplace
may be installed. Consider the traffic pattern in your
room and the location of doors and windows. Moving
air from ceiling fans, open doors and hot air grilles may
cause the flames to soot. If a disturbance is found that
effects the flames, it must be eliminated by turning off
the ceiling fan, closing the door or closing or moving the
hot air register. A corner location may be best where
space is limited.
Your fireplace weighs no more than some of your fine
furniture. If the fireplace is located near a load bearing
wall, additional supports to the foundation will not be
necessary. HEAVY FACINGS SUCH AS BRICK,
STONE, ETC., MAY REQUIRE ADDITIONAL FOUNDATION SUPPORT.
ALTHOUGH THIS UNIT MAY BE INSTALLED ON
COMBUSTIBLE SURFACES, IT MUST NOT BE
INSTALLED ON CARPET OR VINYL.
Room Divider
Partial Room
Projection
Full Room
Projection
Corner
Flush
T224
Fig. 2 Locating the fireplace.
Gas Line
The gas line must be installed before framing in the
fireplace by a licensed gas line installer.
Drafts
Do not locate the fireplace in high traffic areas or areas
exposed to high drafts and winds. Locate the fireplace
away from furniture and draperies.
Fireplace Clearances
The fireplace may be placed directly on a combustible
floor, against a combustible wall at marked clearances
or on a raised wooden platform.
If the fireplace is to be installed on a raised wooden
platform, the platform must be a continuous level
surface. The fireplace must be secured in place so it
cannot shift positions. The nailing flanges on the sides
of the firebox make securing it to the framing easy.
They were designed to allow the installation of 1/2"
wallboard or plywood flush with the face of the fireplace.
Only the header (Fig. 1) may rest on the standoffs on
top of the firebox.
When the fireplace is installed over carpeting, vinyl, tile
or any combustible material other than wood flooring, it
must be installed on a metal or wood panel extending
its full width and depth. Alternatively, the carpeting, vinyl
tile, etc., may be removed from beneath the fireplace
before installing. COMBUSTIBLE MATERIALS MUST
NOT BE INSTALLED OVER OR TOUCH ANY BLACK
PAINTED SURFACE. DO NOT BLOCK HEAT CIRCULATING AIR OUTLETS. DOING SO MAY RESULT IN
POTENTIAL FIRE HAZARD.
Clearances
To ensure a safe installation the following instructions
must be carefully observed.
1. Sidewall Clearances: Clearances from the side of
the fireplace opening to any combustible wall should
not be less than 5". (Fig. 3a)
2. Ceiling Clearances: The ceiling height should not
be less than 42" from the top of the fireplace opening.
3. Mantel Clearances:
A. If the fireplace has no mantelpiece, then the heat
resistant material must extend upwards a distance of at least 9¹⁄₂" from the fireplace opening.
(Fig. 3b) A mantel projection must be a minimum
of 24” above the top fireplace opening if a canopy
is not installed.
B. Noncombustible materials used in this installation
such as slate, marble, tile, etc. must be at least
1/2" thick. Do not install a combustible material
behind sheet metal. Failure to use noncombustible materials above the opening as specified in
these instructions may cause damage to the
materials used and create a fire hazard.
C. An optional heat reducing canopy is available for
use with the fireplace. Use of this canopy is
optional in order to reduce mantel heights as
shown in Figure 3c. If the canopy is installed, a
combustible mantel piece may project 2” from the
wall at 9¹⁄₂” above the fireplace opening. A 6”
mantel projection at 16” above the fireplace
4
20007435