INSTALLER/CONSUMER
SAFETY INFORMATION
Read and save
these instructions.
This book contains your installation instructions and should be kept in a safe place. For you to realize all the advantages and use of the reliable ser­vice that has been engineered into your fireplace, you must carefully follow all of the instructions contained in this book regarding installation and operation of the fireplace.
These instructions should be read care­fully in their entirety before beginning installation of the fireplace.
It is suggested that you wear work gloves and safety glasses to protect your hands and eyes when installing your fireplace. NOTE: Authorities having jurisdiction (i.e. building inspectors, fire marshals, etc.) should be consulted be­fore installation to determine the need to obtain a permit.
When installing the Blower Kit, it is necessary to bring the power source to the fireplace before walls are enclosed. Refer to Blower Kit instructions.
These fireboxes are approved as uni versal fireboxes and can be paired with any ANSI Z21.11.2 approved vent-free log set. The vent-free log manufacturer’s instructions - in­cluding their required dimensional clearances for firebox size, - must be followed.
Refer to the manual that is packed with the log set for operating instructions.
Vent-Free Gas Fireboxes Model: UV36
-
Homeowner’s Installation and
Operating Instructions
CFM Specialty Home Products Unvented Gas Logs VL24MN, VL24MP, VL24RN, VL24RP, VFL34MN, VFL34MP, VFL34RN, VFL34RP may be used with this firebox. (Refer to Page 4)
CFM Specialty Home Products
410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777
www.majesticproducts.com • www.vermontcastings.com
20007446 6/05 Rev. 4
UV36 Vent-Free Firebox
Table of Contents
This book contains your operating instructions and should be kept in a safe place. For you to realize all the advan­tages and use of the reliable service that has been engineered into your fireplace, you must carefully follow all of the instructions contained in this book regarding installation and operation of the fireplace.
These instructions should be read carefully in their entirety before beginning installation of the fireplace.
It is suggested that you wear work gloves and safety glasses to protect your hands and eyes when installing your fireplace.
NOTE: Authorities having jurisdiction (i.e. building inspectors, fire marshals, etc.) should be consulted before installa­tion to determine the need to obtain a permit.
FAILURE TO FOLLOW THESE INSTRUCTIONS WILL VOID YOUR WARRANTY AND MAY PRESENT A FIRE HAZARD.
Important Information .................................................................................................................. 3
Fireplace Dimensions ..................................................................................................................4
Installation Instructions
Choosing the Location of Your Fireplace ............................................................................5
Gas Line ............................................................................................................................. 5
Drafts ..................................................................................................................................5
Framing clearances ............................................................................................................5
Installing the Firebox ..........................................................................................................6
Finishing the Fireplace .......................................................................................................7
Install Optional Outside Air Kit ............................................................................................8
Replacement Parts ..................................................................................................................... 10
Servicing ...........................................................................................................................10
Accessories .................................................................................................................................10
Warranty ...................................................................................................................................... 11
Unvented Room Heaters
Units: UV36 GF1VU2
UV36
Certified To
ANSI Z 21.91.2001
Ventless Fireboxes
for use with
any ANSI Z21.11.2
2
20007446
Important Information
INSTALLER: Please leave these instructions with the
owner. OWNER: Please retain these instructions for future reference.
IMPORTANT: READ THESE INSTRUCTIONS CARE­FULLY BEFORE OPERATING.
WARNING: Any change to this heater or its con­trols can be dangerous.
This heater shall not be installed in a confined space or unusually tight construction unless provi­sions are provided fro adequate combustion and ventilation air.
NOTES
Due to high temperatures, the appliance should be
located out of traffic and away from furniture and draperies.
Installation and repair must be done by a qualified service
person or gas appliance installer.
The appliance must be inspected before use and at least
annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, dust and pet hair, etc. It is important that the control compartment, burners and cir­culating air passageways of the appliance be kept clean.
After servicing, always check for leaks.
DO NOT place clothing or other flammable material on
or near the appliance.
The installation must conform with local codes or, in the
absence of local codes, with the NATIONAL FUEL GAS CODE, ANSI Z223/NFPA 54, latest edition.
Any safety screen or guard removed for servicing an appli-
ance must be replaced prior to operating the heater.
DO NOT use this heater in recreational vehicles, bed-
rooms or bathrooms.
If this is the ONLY gas appliance, we recommend a
minimum 200 pound cylinder with a fill gauge. Use of a 100 pound cylinder is not recommended. Other household gas appliances may require the tank size to be larger. Do not operate the vent-free heater if the
fuel level in the propane tank is below 1/4 full.
DO NOT use this heater if any part of it has been under
water. Immediately call a qualified technician to inspect the appliance and replace any part of the control system and
any gas control which has been under water.
Check local, state or city codes to determine if un-
vented heaters are permitted.
This appliance may be installed in an after-market* manu-
factured “mobile” home where not prohibited by state or local codes.
*After-market: Completion of sale, not for purpose of re-sale from the
manufacturer.
Children and adults should be alerted to the hazard of high surface temperature and should stay away to avoid burns or clothing ignition.
20007446
UV36 Vent-Free Firebox
To avoid irreparable damage to the appliance or personal in jury; matches, paper, garbage or any other material must not be placed or thrown on top of the logs or into the flames.
To avoid personal injury, do not touch hot surfaces when the appliance is operating.
Close supervision is necessary when the appliance is being operated near children.
This appliance is intended to be used only for supplemental heat. Do not use it routinely as a primary heat source. Continuous operation could produce excessive humidity de­pending on construction characteristics and outdoor tempera­tures (below 20°F). Over time, this could cause condensation
to form and damage wall structures and exterior paint.
WARNING: Do not install glass doors on this fire place.
WARNING: If the area in which the heater may be operated is smaller than that defined as an uncon­fined space or if the building is of unusually tight construction, provide adequate combustion and ventilation air by one of the methods described in the National Fuel Gas code, ANSI Z223.1/NFPA 54, section 5.3 or applicable local codes.
WARNING: Do not allow fans to blow directly into the fireplace. Avoid any drafts that alter burner flame patterns.
WARNING: Do not use a blower insert, heat ex­changer insert or other accessory not approved for use with this heater.
WARNING: During manufacturing, fabricating and shipping, various components of this appli­ance are treated with certain oils, films or bonding agents. These chemicals are not harmful but may produce annoying smoke and smells as they are burned off during the initial operation of the appli­ance, possibly causing headaches and eye/lung irritation. This is a normal and temporary occur­rence.
The National Fuel Gas Code, ANSI Z223.1/NFPA 54 defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8m3 per kw) of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms com­municating directly with the space in which the appliances are installed, through openings not furnished with doors, are considered a part of the unconfined space.
-
-
3
UV36 Vent-Free Firebox
36"
33
"
31
"
17"
1"
21
"
35"
50"
Rough Opening Width 36"
Rough Opening Height
14"
Rough Opening Depth
35
"
33"
1/2"
3"
7"
8"
11"
8"
Outside Air Access
Gas Line Access
Gas Line Access (Not used on this model)
3"
7"
8"
8"
Electrical Access
Gas Line Access
20"
11"
30
"
Any ANSI approved vent free log set with a maximum of 39,000 Btu/h or less that will fit into the firebox may be used. (Fig. 1a)
The following CFM Specialty Home Products vent free gas logs sets may be used:
VL24MN, VL24MP, VL24RN, VL24RP, VFL34MN, VFL34MP, VFL34RN, VFL34RP.
Fireplace Dimensions
Fig. 1a Firebox dimensions.
7446
Fig. 1b UV36 specifications and framing.
1/2” Clearance to combustibles not required at this point.
4
20007446
Loading...