Magnetek BatteryCharger Instruction Manual

Battery Charger Instruction Manual – October 2010
12
U.S. Service Information
1.866.MAG.SERV (1.866.624.7378)
Magnetek Material Handling N49 W13650 Campbell Drive Menomonee Falls, WI 53051
Phone: 800.288.8178 Fax (Service): 262.783.3508
Canada Service Information:
4090B Sladeview Crescent Mississauga, Ontario L5L 5Y5 Canada
Phone: 1.800.792.7253 Fax: 1.905.828.5707
5) Replacement Parts and Service
178-01597-0128: BT128-0 Rechargeable Battery
178-01597-0126: BT126-0 Rechargeable Battery
178-00203: Parallel Cable
178-01681-0010: DC Power Adapter assembly
178-00202: AC Power Adapter assembly
195-50363-0128: Charger assembly for BT128-0
195-50362-0126: Charger assembly for BT126-0
195-50363-0010: Battery Charger w/AC Power Adapter for BT128-0 battery
195-50363-0020: Battery Charger w/DC Power Adapter for BT128-0 battery
195-50363-0030: Battery Charger w/parallel cable for BT128-0 battery
195-50362-0010: Battery Charger w/AC Power Adapter for BT126-0 battery
195-50362-0020: Battery Charger w/DC Power Adapter for BT126-0 battery
195-50362-0030: Battery Charger w/parallel cable for BT126-0
battery
If there are any problems or questions in regards to the operation
of this unit, please contact one of our representatives:
Battery Charger Instruction Manual – October 2010
1
Magnetek Battery
Charger
NiMH Battery Charger (Fast
Charge)
Instruction Manual
For use in:
195-50363-0010, 195-50363-0020, 195-50363-0030
195-50362-0010, 195-50362-0020, 195-50362-0030
October 2010
Part Number: 195-50479-R1
©Copyright 2010 Magnetek
Battery Charger Instruction Manual – October 2010
2
Table of Contents
1) Warnings and Cautions page 5
2) Single Charger Instructions page 8
3) Multiple Charger Instructions page 10
4) Troubleshooting page 11
5) Replacement parts and Service page 12
©2010 MAGNETEK MATERIAL HANDLING All rights reserved. This notice applies to all copyrighted materials included with this product, including, but not limited to, this manual and software embodied within the product. This manual is intended for the sole use of the persons to whom it was provided, and any unauthorized distribution of the manual or dispersal of its contents is strictly forbidden. This manual may not be reproduced in whole or in part by any means whatsoever without the expressed written permission of MAGNETEK.
Battery Charger Instruction Manual – October 2010
11
4) Troubleshooting
Problem
Possible Reasons
Suggestions
Status LED
flashes Red
Batteries
too hot/cold
A battery must be from 50-104ºF (10-40ºC) to
charge. Charging will resume when the battery
gets back to its specified temperature range.
Wrong
battery type
If the wrong type of battery is placed in the
charger, it will not charge. Make sure the correct
battery type is used. ONLY USE BATTERIES
PROVIDED BY MAGNETEK!
Battery
contacts
are dirty or
damaged
Inspect battery contacts. If dirty, wipe with
Isopropyl alcohol. DO NOT SUBMERGE. If
damaged, replace battery pack.
Battery has
not
indicated
full charge
in allotted
time
Various environmental conditions may elicit the
charger to fail to recognize a full charge condition.
In this case, the charger will stop charging after a
pre-programmed time and indicate a fault. If this
happens repeatedly contact, Magnetek Inc. as the
charger may require service.
Charger too
hot/cold
Re-locate charger to an environment that does not
exceed 50-104ºF (10-40ºC).
Table 1.0
Conditioning: A new rechargeable battery pack may experience a
low usable capacity during the first few charge cycles due to long storage. This is normal. Battery capacity will be restored after several full charge/discharge cycles.
Loading...