This specification applies to the Pb Free high current type SMD inductors for
(1) SHAPES AND DIMENSIONS
(2) ELECTRICAL SPECIFICATIONS
(3) CHARACTERISTICS
MNR-3012-SERIES
PRODUCT INDENTIFICATION
MNR - 3012 - 3R3 N
①②③④
① Product Code
② Dimensions Code
③ Inductance Code
④ Tolerance Code
A: 3.0±0.1 mm
B: 3.0±0.1 mm
C: 1.20Max. mm
D: 1.30Typ. mm
E: 0.85Typ. mm
SEE TABLE 1
TEST INSTRUMENTS
L : HP 4284A PRECISION LCR METER (or equivalent)
SRF : HP 4291B IMPEDANCE ANALYZER (or equivalent)
RDC : CHROMA MODEL 16502 MILLIOHMMETER (or equivalent)
There shall bedirection is made approximately 3mm.(keep time 30 seconds)
no mechanicalPCB dimension shall the page 7/9
damage or elec- F(Pressurization)
trical damege.
The sample shall be soldered onto the printed circuit board
in figure 1 and a load applied unitil the figure in the arrow
PRESSURE ROD
figure-1
Vibration
Solderability
△L/Lo≦ ±5%
There shall beand a frequency of from 10 to 55Hz/1 minute repeated should
no mechanicalbe applied to the 3 directions (X,Y,Z) for 2 hours each.
damage.(A total of 6 hours)
New solderFlux (rosin, isopropyl alcohol{JIS-K-1522}) shall be coated
More than 90%over the whole of the sample before hard, the sample shall
The sample shall be soldered onto the printed circuit board
and when a vibration having an amplitude of 1.52mm
then be preheated for about 2 minutes in a temperature of
130~150℃ and after it has been immersed to a depth 0.5mm
below for 3±0.2 seconds fully in molten solder M705 with
a temperature of 245±5℃.
More than 90% of the electrode sections shall be couered
with new solder smoothly when the sample is taken out of
the solder bath.
MAG.LAYERS
MNR-3012-SERIES
Page-3/8
MECHANICAL
Sodering temperature (℃)
(230
℃)
2 min
TEST ITEMSPECIFICATION
Resistance toThere shall beTemperature profile of reflow soldering
Soldering heatno damage or
(reflow soldering)problems.
300
250
soldering
(Peak temperature 260±3℃ 10 sec
200
150
100
50
Pre-heating
150 ~ 180℃
30 sec Min
+0
10
sec.
Slow cooling
(Stored at room
temperature)
2 min. or more
The specimen shall be passed through the reflow oven with the
condition shown in the above profile for 1 time.
The specimen shall be stored at standard atmospheric conditions
for 1 hour, after which the measurement shall be made.
ELECTRICAL
TEST ITEMSPECIFICATIONTEST DETAILS
InsulationThere shall beDC 100V voltage shall be applied across this sample of top
resistanceno other surface and the terminal.
damage or
problems.
DielectricThere shall beAC 100V voltage shall be applied for 1 minute acrosset the top
withstandno othersurface and the terminal of this sample
voltagedamage or
problems.
Temperature
characteristics
△L/L20℃≦±10%
0~2000 ppm/℃an ambient temperature of -20 to +85℃,and the value
The insulation resistance shall be more than 1 × 108 Ω.
The test shall be performed after the sample has stabilized in
calculated based on the value applicable in a normal
temperature and narmal humidity shall be △L/L20℃≦±10%.
MAG.LAYERS
MNR-3012-SERIES
Page-4/8
ENVIROMENT CHARACTERISTICS
TEST ITEMSPECIFICATION
High temperature
storage
△L/Lo≦±5%
There shall beUpon completion of the measurement shall be made after the
no mechanicalsample has been left in a normal temperature and normal
damage.humidity for 1 hour.
The sample shall be left for 96±4 hours in an atmospere with
a temperature of 85±2℃ and a normal humidity.
Low temperature
storage
Change of
temperaturein the table 2 below and then it shall be subjected to standard
△L/Lo≦±5%
There shall beUpon completion of the test, the measurement shall be made
no mechanicalafter the sample has been left in a normal temperature and
damage.normal humidity for 1 hour.
△L/Lo≦±5%
There shall beatmospheric conditions for 1 hour, after which measurement
no other dama-shall be made.
ge of problems
The sample shall be left for 96±4 hours in an atmosphere with
a temperature of -25±3℃.
The sample shall be subject to 5 continuos cycles, such as shown
table 2
TemperatureDuration
1
2
3
4
-25±3℃
(Themostat No.1)
Standard
atmospheric
85±2℃
(Themostat No.2)
Standard
atmospheric
30 min.
No.1→No.2
30 min.
No.2→No.1
Moisture storage
Test conditions:
The sample shall be reflow soldered onto the printed circuit board in every test.
△L/Lo≦±5%
There shall beUpon completion of the test, the measurement shall be made
no mechanicalafter the sample has been left in a normal temperature and
damage.normal humidity more than 1 hour.
MAG.LAYERS
The sample shall be left for 96±4 hours in a temperature of
40±2℃ and a humidity(RH) of 90~95%.
MNR-3012-SERIES
Page-5/8
(5) LAND DIMENSION (Ref.)
PCB: GLASS EPOXY t=1.6mm
(5)-1 LAND PATTERN DIMENSIONS
(STANDARD PATTERN)
unit:mm
(5)-2 SUBSTRATE BENDING TEST BENDING TEST BOARD
MAG.LAYERS
MNR-3012-SERIES
Page-6/8
(6) PACKAGING
(6)-1 CARRIER TAPE DIMENSIONS (mm)
(6)-2 TAPING DIMENSIONS (mm)
Unreeling
Direction
MAG.LAYERS
MNR-3012-SERIES
Page-7/8
(6)-3 REEL DIMENSIONS (mm)
(6)-4 QUANTITY
1500pcs/Reel
The products are packaged so that no damage will be sustained.
MAG.LAYERS
MNR-3012-SERIES
Page-8/8
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.