Magic Chef CES3760AAW, CES3760AAB, CES3760AAA, MER5770ACB, MER5770AAB Installation Manual

...
INSTALLER: LEAVE THESE INSTRUCTIONS WITH THE APPLIANCE
INSTALLATION MANUAL
Electric 30-inch Free-standing,
Slide-in & Drop-in Ranges
PLEASE KEEP THIS MANUAL FOR FUTURE REFERENCE
THE MANUAL IS INTENDED TO ASSIST IN THE INITIAL INSTALLATION AND ADJUSTMENTS OF THE RANGE.
Only qualified personnel should install or service this range.
range,
Improper installation, adjustment, alteration, service, maintenance or
use of range can result in serious injury or property damage,
CLEARANCE DIMENSIONS
For complete information in regard to installation of free-standing, drop-in and slide-in ranges, see figures 1 through 4 on pages 2, 3 and 4. For
SAFETY CONSIDERATIONS do not install a range in any combustible cabinetry which is not
in accord with the installation clearances shown in figure 1.
CAUTION: Some cabinets and building materials are not designed to withstand the heat produced by the normal safe operation of a listed appliance. Discoloration or damage, such as delamination, may occur.
8101 P329-60
(05-99-01)
MOBILE HOMES
The installation of a range designed for mobile home installation must conform with the Manufactured Home
Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home
Construction and Safety, Title 24 HUD, Part 280) or, when such standard is not applicable, the Standard for
Manufactured Home Installations 1982 (Manufactured Home Sites, Communities and Set-Ups), ANSI
A225. l-latest edition, or with local codes.
LOCATING THE RANGE
Place range in a well lit area. Do not set range over holes in the floor or other locations where it may be subject to
strong drafts. Any opening in the wall behind the range and in the floor under the range should be sealed. Make
sure the flow of combustion or ventilation air is not obstructed.
INSTALLATION DRAWINGS
FIGURE 1
"A" = 30 inches minimum clearance between the top of the cooking surface and the bottom of an unprotected wood or metal cabinet, or "A" = 24 inches minimum when
bottom of wood or metal cabinet is protected by not less than 1/4-inch thick flame-retardant millboard covered with
not less than No. 28 MSG sheet steel, 0.015-inch thick stainless steel, 0.024-inch thick aluminum, or 0.020-inch thick copper.
To eliminate the risk of burns or fire by reaching over heated surface units, cabinet storage space located
above the surface units should be avoided. If cabinet storage is to be provided, the risk can be reduced by
installing a range hood that projects horizontally a minimum of 5 inches beyond the bottom of the cabinets.
FIGURE 1
1, 2, 3 - COMBUSTIBLE BUILDING WALLS.
4 - COMBUSTIBLE WALL CABINET.
A free-standing range may be installed adjacent to (0" from) combustible walls 1, 2 & 3.
A slide-in and drop-in range may be installed adjacent to (0" from) combustible walls 2 & 3. The rear wall clearance
will be determined by cabinet cut-out depth shown in illustrations on pages 3 and 4.
-2-
TOP
.,>-
25" NORMAL
COUNTER
TOP DEPTH
PROVIDE FOR 120/208,
120/240 VOLT OUTLET
PER APPLICABLE CORD IN THIS AREA.
BEFOREATTEMPTING INSTALLATION,ADJUST
RANGELEVELINGLEGS TOACCOMMODATE THISDIMENSION.
--....
FIGURE 2
24" CAB DEPTH .
FLAT
NET
NOTE: ONCABINETTOPSWITH
FORMEDFRONTEDGE,SHAVE RAISEDSECTIONTOCLEARTOP.
PROVIDEFOR1201208,
120/240VOLTOUTLET
PERAPPLICABLE
CORDIN THISAREA.
MIN. _,.
25"MINIMUM
COUNTER
TOPDEPTH
CAUTION: SOMEWHITEEUROPEANSTYLECABINETSAREEQUIPPEDWITHDELICATEWHITEVINYL
DRAWERANDDOORFRONTS.THEVINYLMAY NOTBEDESIGNEDTOWITHSTANDTHE HEATPRODUCEDBY THE NORMALSAFEOPERATIONOF A SELF-CLEANRANGE.
DISCOLORATIONOR DELAMINATIONMAYOCCUR.TO AVOIDPOSSIBLEDAMAGE,WE RECOMMENDINCREASINGTHE 30" CABINETOPENINGTO31 114"MINIMUMANDUSING
HEATSHIELDKIT-CABKITV.THECOUNTERTOPCUT-OUTMUSTREMAIN30".
* Whenreplacingan existingunit,a maximumof23 1/2" isacceptable.Ifthecutdepthexceeds23 1/2",usefillerkit(K70Fill).
FIGURE 3
-3-
24"
NOTE: ONCABINETTOPSWITH
FORMEDFRONTEDGE,SHAVE RAISEDSECTIONTOCLEARTOP.
1/4" CUTDEPTH
PROVIDEFOR1201208,120/240
VOLTJUNCTIONBOXFORRANGE
CONDUITBELOWUNIT.
1/4"
DEPTH
36" COUNTER
TOPHEIGHT
27 1/2"
FROMTOPOF
COUNTER
23 5/8" MIN.
FLATAREA
25" MINIMUM
COUNTER t,
30 _'
CABINET
OPENING
24"
NOTE:BEFORE
ATTEMPTINGINSTALLATION,
RECOMMENDTHEUSEOF _ DEPTH 3 112"WIDE SLATSONEACHSIDE.
,_..,,,,,CABINET
ADJUSTRANGELEVELING
LEGSTOACCOMMODATE
THISDIMENSION.
FIGURE 4
* When replacing an existing unit, a maximum of 23 1/2" is acceptable. If the cut depth exceeds 23 1/2", use filler kit (K70 Fill).
-4-
ANTI-TIP DEVICE INSTALLATION INSTRUCTIONS
WARNING: A risk of range tip-over exists if the appliance is not installed in accordance with the provided installation
instructions. The proper use of this device minimizes the risk of TIP-OVER. In using this device the consumer must
still observe the safety precautions as stated in the USE and CARE MANUAL and avoid using the oven door
and/or lower drawer as a step stool.
Installation instructions are provided for wood and cement in either floor or wall. Any other type of construction may
require special installation techniques as deemed necessary to provide adequate fastening of the ANTI-TIP
bracket to the floor or wall. The bracket may be installed to engage the left or right rear leveling leg.
STEP 1 - Locating The Bracket (See Figure 5) A. Determine where either the right or left "EDGE" of the
range will be located and mark the floor or wall.
B. Place the BRACKET 15/16" from the marked "EDGE"
toward center of opening and against the back wall, as shown in figure 5.
C. Use the bracket as a template and mark the required
holes, as shown in figure 5 for the type of construction you will be using.
D. Free-standing and slide-in ranges may be secured to
either floor or wall. Drop-in range may only be secured to slat in cabinet.
STEP 2 -Anti-Tip Bracket Installation A. Wood Construction:
1. Floor: Locate the center of the two holes identified in figure 5 as "HOLES FOR FLOOR". Drill a 1/8"
pilot hole in the center of each hole (a nail or awl may be used if a drill is not available). Secure the
ANTI-TIP bracket to the floor with the two screws provided. Proceed to Step 3.
2. Wall: Locate the center of the two holes identified in figure 5 as "HOLES FOR WALL". Drill an
angled 1/8" pilot hole in the center of each hole as shown in figure 6. (A nail or awl may be used if a drill is not available). Secure the ANTI-TIP bracket
FOR
to the wall with the two screws provided as shown in figure 6. Proceed to STEP 3.
B,
Cement or Concrete Construction:
1. Suitable screws for concrete construction can be obtained at the hardware store. Drill the required
size hole for the hardware obtained into the concrete at the center of the holes identified in
figure 5 as "HOLES FOR FLOOR". Secure the ANTI-TIP bracket to the floor. Proceed to STEP 3.
STEP 3 - Range Installation
A. Free-standing and slide-in ranges may be installed by
one person. The drop-in requires two persons due to adjusting leveling legs and making electrical
connection while range is suspended in cut-out.
B. Align the range to its designated location and slide it
back into position. Note: A minimum clearance of 1/4" is required between the range and the leveling foot
that will engage the ANTI-TIP bracket, see figure 6. CAUTION: Damage to the range may occur if range
is moved or lifted by grasping the main top or backguard. (If equipped).
C. All slide-in and drop-in ranges are equipped with a
non lift-up top. All free-standing ranges with a glass top are non lift-up. Coil tops are lift-up except for some Canadian models that are non lift-up.
D. For SAFETY CONSIDERATIONS as well as optimum
performance adjust the range so that it is level. This may be checked by placing a spirit level or a large
pan of water on the cooktop or the oven rack. If an adjustment is required on free-standing, pull the range
forward, tip the range and rotate the leveling feet as required. Slide-in and drop-in ranges require total
removal from cabinet before an adjustment can be made.
E. To check the range for proper installation of the
anti-tip bracket: Use a flashlight and look underneath the bottom of the range to see that one of the rear
leveling legs is engaged in the bracket slot.
F. Proceed with the remainder of the installation
instructions provided with the range.
NOTE: USE A MINIMUM OF (2) SCREWS TO INSTALL BRACKET
TO THE WALL OR FLOOR,
HOLES
FLOOR
FIGURE 5
AR- # 9219 761B
FREE-STANDING: FASTEN BRACKET TO WALL OR FLOOR.
I: I t'Z-I I I:} I::
-5-
CONNECTING THE RANGE
ELECTRIC SUPPLY
The range must be installed in accordance with Local and National Electric Code (NEC) ANSI/NFPA No. 70-latest
edition. See rating plate on front of range for total connected KW rating.
OUTSIDE WIRING
Your local utility company will tell you whether the present electric service to your home is adequate. It may be
necessary to increase the size of the wiring to the house and service switch to take care of the electrical load
demanded by the range. The kilowatt rating for the range is specified on the name plate on the range.
HOUSE WIRING
Most local Building Regulations and Codes require that all electrical wiring be done by licensed electricians. All
wiring should conform to Local and National Electrical Codes. This range requires a single phase three wire
120/240 or a 120/208 volt, 60 Hz, AC circuit. Wiring codes
require a separate circuit be run from the main entrance panel to the range and that it be equipped with separate
disconnect switch and fuses, either in the main entrance panel or in a separate switch and fuse box. In some
communities, a solid or flexible continuous armored conduit must be used from main entrance panel to the terminal box on the rear of the range. Others will permit
the termination of the range circuit at a polarized three or four wire plug-in outlet placed at a convenient point near
the back of the range. The range is then connected to this outlet through an approved range connector (pigtail)
fastened securely to the terminal block with proper strain relief at the range and a three or four pronged plug at the opposite end.
RANGE CONNECTIONS
Some models are shipped direct from the factory with service cords (pigtails) attached. There are no range
connections necessary on these models. Just plug into the range outlet. On models not provided with a service
cord and models having a conduit, connection to the power supply is necessary. REMEMBER - mobile homes
and some LOCAL CODES DO NOT PERMIT GROUNDING THROUGH NEUTRAL. Hence, 4-wire
service MUST be provided for such installations. All others permit 3-wire service. Use COPPER WIRE ONLY.
Make connections as explained below and with reference to the appropriate illustration (see figures 7 thru 9). After
installation, insure tightness of all electrical connections and replace all covers.
NOTE: Cord replacement - ONLY a power supply cord rated at 240 volts minimum, 40 amperes or 50 amperes
power supply cord that is marked for use with nominal 1 3/8" (34.93 mm) diameter connection opening, with closed
loop terminals and marked for use with ranges shall be used.
Remove terminal block access cover from range back. (See figure 7). Figure 7 shows the back of a free-standing
range, slide-in and drop-in ranges have a flat access cover on the left side of the main wire cover.
-6-
CONDUIT
PLATE
FIGURE 7
ACCESS COVER
TERMINAL
CONNECTION
BLOCK
CONNECTING THE RANGE
FIGURE 8 3-Wire Service Cord Installation
1. Insure that the copper ground strap IS CONNECTED between the middle post of the main terminal
connection block and the range chassis.
, The middle wire of the service cord MUST connect to
the neutral (middle) post of the main terminal block. The other two wires of the service cord connect to the
outside posts of the main terminal connection block.
Polarity is unimportant.
3. Position strain relief with flanges on top of conduit plate as shown and secure to service cord.
RED
WHITE
BLAOK_ _
MAIN TERMINAL
CONNECTION BLOCK
SERVICE CORD
MIDDLE WIRE OF
CONDUIT _0
_%_O CONDUIT
STRA'_--------M__ _
RELIEF_ _ _i#
PLATE _5__TAMPED
STAMPED _/ -- _ R_OVE BRACKET, FLIP CORD & RE-ATTACH WITH HOLE
FOR USE WITH CONDUIT,
MARKED "CONDUIT" DOWN
FIGURE 9 3-Wire Conduit Installation
,
The range conduit must be routed and properly connected to an approved electrical junction box
behind the range.
,
The red and black wires from the range conduit must
respectively connect to the red and black service
wires. An approved wire connector must be used.
,
In the range conduit, the white wire (N) is twisted at
the factory to the uninsulated (BARE) wire. This bare wire must connect to the white wire (N) from the power
supply as shown. The bare copper wire is the range chassis ground.
ROUTE RANGE CONDUIT SO THAT CONTAINS NO K)NKS AND DOES NOT
INTERFERE WITH INSTALLATION OF
UNIT.
WHITE (N)
BARE COPPER (G)
CONDUIT FROM
RANGE
(L1)
(L2)
SHOWN IF NOT FLUSH TO WALL
NORMAL - 3 WIRE PLUG
ALTERNATE INSTALLATION
FIGURE 8
3 WIRE HOUSE WIRE HOOK-UP
(RANGE GROUNDED THROUGH NEUTRAL CONDUCTOR)
FIGURE 9
NORMAL - 3 WIRE CONDUIT
SUPPLY
JUNCTION
BOX
APPROVED CONNECTORS
-7-
CONNECTING THE RANGE
FIGURE 10 4-Wire Service Cord Installation
(Mobile Homes Or As Required By Codes)
1. The copper ground strap connected between the neutral (middle) post of the main terminal block and the
chassis MUST be cut off as shown in figure 10. Use the
green ground screw to attach the green (chassis ground) from the 4 conductor cord. Keep the green
ground screw. Only a 4 conductor cord should be used.
2. The green wire from the service cord must connect to the range chassis using the green ground screw.
3. The white wire of the service cord must connect to the
neutral (middle) post of the main terminal block. The
other two wires of the service cord connect to the red
and black posts of the main terminal block, respectively.
4. Position the strain relief with flanges on top of conduit
plate as shown and secure to service cord.
THIS P_ITION OF /
RED _ ' I
_ITE_ \ _IN TERMINAL
BLACK _NNECEION BLOCK _-_
k SERVICE WIREcoRD XMIDDLE
GREEN PLATE
.......
STRAIN .0 _0 _[
REL'EF _i I
OUTLET TO BE ROTATED SHOWN IF NOT FLUSH TO WALL
MUST BE RE_VED GRINDING STRAP
OF
CONDUIT
_O RE_VE BRACKET, FLIP
ALTERNATE INSTALLATION
FIGURE 10
4-WIRE PLUG
/
FOR USE WITH CONDUIT,
& RE-ATTACH WITH HDLE _RKED "CONDUIT"
D_N.
-8-
FIGURE 11 4-Wire Conduit Installation
(Mobile Homes Or As Required By Codes)
1. The range conduit must be routed and properly connected to an approved electrical junction box
behind the range.
2. The red and black wires from the range conduit must respectively connect to the red and black service wires.
An approved wire connector must be used.
3. In the range conduit, the white wire (N) is twisted at the
factory to the uninsulated ground wire (BARE). For a 4 wire installation, the white and bare wire MUST be
separated.
4. The white wire from the conduit must be connected to
the white service wire.
5. The uninsulated (bare) wire from the conduit must be connected either to a green or bare service wire.
ROUTE RANGE CONDUIT SO THAT CONTAINS NO KINKS AND DOES NOT
INTERFERE WITH INSTALLATION OF
UNIT.
JIT FROM
RANGE
RED (L1)
JUNCTION
BOX
(L2)
APPROVED
CONNECTORS
WHITE
BARECOPPER (G)-
WIRING METHOD IF CODE DOES
NOT PERMIT GROUNDING THROUGH NEUTRAL CONDUCTOR & ALSO
REQUIRED IN MOBILE HOMES.
SUPPLY
FIGURE 11
4-WIRE CONDUIT
Conversion From 3-Wire To 4-Wire Service
(Free-Standing or Slide-in Models Only With 3-Wire Service Cord Attached).
Disconnect range from power. Remove the access cover on back of range and remove the 3-wire service cord from
the main terminal block. Follow instructions as outlined in figure 8 to connect the 4-wire service cord.
NOTE: Cord replacement - ONLY a power supply cord rated at 240 volts minimum, 40 amperes or 50 amperes
power supply cord that is marked for use with nominal 1 3/8" (34.93 mm) diameter connection opening, with closed
loop terminals and marked for use with ranges shall be used.
-8-