Strip the speaker wiring back about 1/2", loosen the
screw enough to loop the wire around the shaft of the
screw (clockwise), and tighten down the screw with a
slot-head screwdriver.
Note: Make sure the taps on the speakers add up to
no more than the rated power for the amplifier being
used.
70V CONSTANT-VOLTAGE
POWER AMPLIFIER
+
–
Connecting the PATX60
to a Constant-Voltage
Distribution System
In a constant-voltage distribution system, all the
speakers are connected in parallel. This makes it
easy to add or remove speakers from the system
without having to recalculate the impedance of the
load on the amplifier.
Simply add the taps on the speakers connected to
the system and make sure the total power indicated
by the taps does not exceed the rated power of the
amplifier.
70V LINE
The PATX60 is a 70V/100V transformer panel that
replaces the connector panel on the Vision Series
PACX81, PA261, and PA281. It has a 60 watt, 70 Volt
transformer with a terminal strip for external
connections to a 70V or 100V constant-voltage
amplifier.
PATX60
70V/100V Transformer Panel
Quick-Start Guide
PATX 60
VISION
SERIES
COM
60W
30W
15W
70V
100V
COM
60W
NC
30W
CONCEIVED, DESIGNED, AND MANUFACTURED BY MACKIE
INDUSTRIAL • MADE IN ITALY • COPYRIGHT ©2000 • THE FOLLOWING
ARE TRADEMARKS/REGISTERED TRADEMARKS OF MACKIE DESIGN INC.:
"MACKIE", "MACKIE INDUSTRIAL", & THE "RUNNING MAN" FIGURE
SERIAL NUMBER
MANUFACTURING DATE
70V
100V
PAT X 60
VISION
SERIES
COM
60W
30W
15W
70V
100V
30W
CONCEIVED, DESIGNED, AND MANUFACTURED BY MACKIE
INDUSTRIAL • MADE IN ITALY • COPYRIGHT ©2000 • THE FOLLOWING
ARE TRADEMARKS/REGISTERED TRADEMARKS OF MACKIE DESIGN INC.:
"MACKIE", "MACKIE INDUSTRIAL", & THE "RUNNING MAN" FIGURE
SERIAL NUMBER
CAUTION:
SUSPENDING THIS SYSTEM SHOULD BE DONE BY QUALIFIED
TECHNICIANS FOLLOWING APPROPRIATE SAFETY STANDARDS
COM
NC60W
MANUFACTURING DATE
70V
100V
70V CONSTANT-VOLTAGE DISTRIBUTION SYSTEM
www.mackieindustrial.com
16220 Wood-Red Road NE Woodinville, WA 98072
TEL +888.337.7404, FAX +425.487.4337 , industrial@mackie.com
UK +44.1268.571.212, FAX +44.1268.570.809 +info@rcf-uk.com
ITALY +39.0522.354.111, F AX +39.0522.926.208 +industrial@rcf.it
FRANCE +33.3.8546.9160, FAX +33.3.8546.9161 +rcf.commercial@wanadoo.fr
GERMANY +49.2572.96042.0, FAX +49.2572.96042.10 +industrial@mackie.de
Part No. 910-003-20 Rev. C 05/01
© 2001 Mackie Industrial. All Rights Reserved. Printed in Italy.
PAT X 60
VISION
SERIES
COM
60W
30W
15W
70V
100V
CONCEIVED, DESIGNED, AND MANUFACTURED BY MACKIE
INDUSTRIAL • MADE IN ITALY • COPYRIGHT ©2000 • THE FOLLOWING
ARE TRADEMARKS/REGISTERED TRADEMARKS OF MACKIE DESIGN INC.:
"MACKIE", "MACKIE INDUSTRIAL", & THE "RUNNING MAN" FIGURE
SUSPENDING THIS SYSTEM SHOULD BE DONE BY QUALIFIED
TECHNICIANS FOLLOWING APPROPRIATE SAFETY STANDARDS
30W
SERIAL NUMBER
CAUTION:
COM
NC60W
MANUFACTURING DATE
SUSPENDING THIS SYSTEM SHOULD BE DONE BY QUALIFIED
TECHNICIANS FOLLOWING APPROPRIATE SAFETY STANDARDS
70V
100V
Safety First!
CAUTION:
Before connecting and using the
equipment, please read this Quick-Start
Guide carefully and keep it for future
reference.
WARNING! This equipment has been designed
to be installed by qualified professionals
only! There are many factors to be considered
when installing professional sound
reinforcement systems, including mec h anical
and electrical considerations, as well as
acoustic coverage and performance. Mackie
Industrial strongly recommends that this
equipment be installed only by a professional
sound installer or contractor.
1. Read Instructions—All the safety and
operation instructions should be read
before this Mackie Industrial product is
operated.
2. Water and Moisture—This Mackie Industrial
product should not be used near water –
for example, near a bathtub, washbowl,
sink, in a damp cellar, near a swimming
pool, etc.
3. Foreign bodies and liquids—Be careful not
to allow any foreign bodies or liquids to get
into this Mackie Industrial product.
4. Technical service—The user should never
attempt to make any repairs on this Mackie
Industrial product unless otherwise
indicated in the instruction manual. Al l
repairs should be made by a qualified
service technician.
5. Installation—Do not install this Mackie
Industrial product in any way that is not
indicated in the instruction manual.
6. Respect the safety standards—The entire
sound system must be created in
compliance with the current standards and
laws regar ding electrical systems.
Front Panel Features
(For use with the
PA261 and PA281)
(For use with the
PACX81)
Red
Black
Installing the PATX60
70V Connections
When using the PATX60 with a 70V distribution
system, calculate the power usage with the top
1. Remove the six screws securing the connector
plate to the back of the PACX81, PA261, or
PA281 with a #2 Phillips screwdriver.
numbers for the taps (15W, 30W, 60W).
100V Connections
When using the PATX60 with a 100V distribution
system, calculate the power usage with the
IN-OUT
bottom numbers for the taps (30W, 60W).
WARNING: DO NOT USE THE TAP LABELED
NC NEXT TO THE COM TERMINAL IN A 100V
SYSTEM.
Security Cover
After connecting the speaker wiring to the screw
CONCEIVED, DESIGNED, AND
MANUFACTURED BY MACKIE
INDUSTRIAL • MADE IN ITALY •
COPYRIGHT ©1999 • THE FOLLOWING
ARE TRADEMARKS/REGISTERED
TRADEMARKS OF MACKIE DESIGN INC.:
"MACKIE", "MACKIE INDUSTRIAL",
& THE "RUNNING MAN" FIGURE
SERIAL NUMBER
PA 261
VISION
SERIES
-
IN
OUT
+1/–1FULL RANGE 200W-4
SUSPENDING THIS SYSTEM SHOULD
TECHNICIANS FOLLOWING
APPROPRIATE SAFETY STANDARDS
MANUFACTURING DATE
CAUTION:
BE DONE BY QUALIFIED
PA 261
VISION
SERIES
terminals, install the security cover to insulate the
OUT
connections.
2. Remove the connector panel, being careful not
to damage the gasket surrounding the opening
PATX 60
VISION
SERIES
COM
60W
30W
15W
70V
100V
COM
60W
NC
30W
CONCEIVED, DESIGNED, AND MANUFACTURED BY MACKIE
INDUSTRIAL • MADE IN ITALY • COPYRIGHT ©2000 • THE FOLLOWING
ARE TRADEMARKS/REGISTERED TRADEMARKS OF MACKIE DESIGN INC.:
"MACKIE", "MACKIE INDUSTRIAL", & THE "RUNNING MAN" FIGURE
SERIAL NUMBER
SUSPENDING THIS SYSTEM SHOULD BE DONE BY QUALIFIED
TECHNICIANS FOLLOWING APPROPRIATE SAFETY STANDARDS
MANUFACTURING DATE
CAUTION:
70V
100V
in the back of the cabinet.
3. Disconnect the red and black wires from
connectors on the panel by pulling the quickdisconnects off the terminals.
Red
Black
To 1+
To 1–
To 1+
To 1–
1+
2–
2+
1+
2–
2+
CONCEIVED, DESIGNED, AND
MANUFACTURED BY MACKIE
INDUSTRIAL • MADE IN ITALY •
COPYRIGHT ©2000 • THE FOLLOWING
ARE TRADEMARKS/REGISTERED
TRADEMARKS OF MACKIE DESIGN INC.:
"MACKIE", "MACKIE INDUSTRIAL",
& THE "RUNNING MAN" FIGURE
1–
1–
Red
Black
IN
SERIAL NUMBER
To OUT+
To OUT-
FULL RANGE 200W-4
MANUFACTURING DATE
OUT+IN
CAUTION:
SUSPENDING THIS SYSTEM SHOULD
BE DONE BY QUALIFIED
TECHNICIANS FOLLOWING
APPROPRIATE SAFETY STANDARDS
+ --
To IN-
To IN+
4. Connect the two red wires to the "+" terminal on
the PATX60 transformer, and connect the two
black wires to the "–" terminal, as shown in the
above illustration.
5. Carefully place the PATX60 panel in the opening
on the back of the cabinet, making sure the
gasket is correctly aligned over the screw holes
and the wires are not pinched between the panel
and cabinet.
6. Reinstall the six screws to secure the PATX60
connector panel into place.
PATX 60W
VISION
SERIES
COM
70V
60W
30W
15W
70V
100V
CONCEIVED, DESIGNED, AND MANUFACTURED BY MACKIE
INDUSTRIAL • MADE IN ITALY • COPYRIGHT ©2000 • THE FO
, "MACKIE INDUSTRIAL"
ARE TRADEMARKS/REGISTERED TRADEMARKS OF MACKIE DESIGN INC.:
"MACKIE"
SERIAL NUM
SUSPENDING THIS SYSTEM SHOULD BE DONE BY QUALIFIED
TECHNICIANS FOLLOWING APPROPRIATE SAFETY STANDARDS
BER
CAUTION:
, & THE "RUNNING MAN" FIGURE
MANUFACTURING DATE
100V
LLOWING
7. An extra serial number label is included with the
Vision speakers. Install the serial number label in
the space provided on the PATX60 panel. Verify
that it is the same number that is on the original
connector plate.
Connections
The connectors on the PATX60 are screw terminals.
When using with a 70V distribution system, connect
either the 15W, 30W, or 60W terminal as indicated by
the top markings to the "+" side of the 70V system,
and connect the COM terminal to the "–" side of the
70V system.
When using with a 100V distribution system, connect
either the 30W or 60W terminal as indicated by the
bottom markings to the "+" side of the 100V system,
and connect the COM terminal to the "–" side of the
100V system.
DO NOT use the NC terminal in a 100V system.