Lynx LOHI Installation Manual

A
IC
GREY
BLACK
BLUE
YELLOW
WHITE
RED
BLUE
RED
YELLOW
WHITE
MOTOR
MOTOR
WHITE
BLUE
YELLOW
RED
WHITE WHITE
WHITE
WHITE
BLUE
WHITE
BLACK
RED
WIRE HARNESS
P/N 11500.00
LOHI
WIRING
YELLOW - LO
RED - MED
BLUE - HI
WHITE - COM
RED - LO
WHITE - COM
BLUE - MED
BLACK - HI
BODY
GREEN
GREEN
TO HOOD RECEPTACLE PLUG
BLACK
GREY
IC
INSTALLATION INSTRUCTION
CAUTION: Before installing ventilator read the HOOD INSTALLATION INSTRUCTIONS.
4 - #8 x ½ Pan Head SMS 1 – Wire Harness (11500.00) 1 – Wire Tie
LOHI
1) Install Hood & Transition per hood installation instruction.
2) Remove parts from carton. Remove all corrugated packaging shims between motor and
housing.
3) Rotate ventilator wheels to confirm they rotate freely.
4) Connect Wire Harness #11500.00 to Hood Receptacle Box.
5) Install ventilator per HOOD INSTALLATION INSTRUCTION using 2- screws.
6) Connect Ventilator to Hood Receptacle Plug on Front Panel using Wire Harness #11500.00, (if
required excessive wires shall be attached to blower body flange notch at point - A using wire tie, twist wire 3 to 4 times to secure excess wire – see picture).
7) Check operation of ventilator per HOOD INSTALLATION INSTRUCTIONS.
Lynx Professional Grills 6023 E. Bandini Blvd. Commerce, CA 90040 Service: (888) Buy-Lynx (888-289-5969)
www.lynxgrills.com Fax: (323) 838-1778
Page 1 of 1 P/N 11863.00 Rev A