Lynx L-LS User Manual

eDART™ System User Guide
Lynx™ Mold-Closed Limit Switch L-LS
The Lynx™ L-LS Mold-Closed Limit Switch is a tie-bar or
machine mountable machine cycle input module designed to be used with the eDART System™.
most injection molding machines by following the installation steps below.
U
Always power down before working on any equipment.
Figure 25: Lynx™ Mold-Closed Limit Switch side view
L-LS Installation
Step 1.
Switch the molding machine to Manual mode and close the mold.
Step 2.
Set the limit switch on the tie-bar as shown in figures 26 and 27.
!
U
Be careful to note the position of the ejector plate, the mold, the limit switch and its cable, so the limit switch and/or its cable does not get caught as the mold opens and closes.
Appendix 32
eDART™ System User Guide
B
A
Figure 26: Lynx™ Mold-Closed Limit Switch front view
A Tie Bar
B Ty-Wrap
Table 25: Figure Labels
Step 3.
Slide the limit switch to the left until an audible click is heard form the switch. See Figure 27.
B
A
C
Figure 27: Lynx™ Mold-Closed Limit Switch side view
L-LS
D
U
Always disconnect the power before working on this or any electrical equip­ment.
A Moving Half
B Ejector Plate
C Tie Bar
D Slide
Appendix 33
Loading...
+ 1 hidden pages