eDART™ System User Guide
Lynx™ Mold-Closed Limit Switch
L-LS
The Lynx™ L-LS Mold-Closed Limit Switch is a tie-bar or
machine mountable machine cycle input module designed to be
used with the eDART System™.
The L-LS switch can be used to easily get a machine trigger off of
most injection molding machines by following the installation steps
below.
U
Always power down before working on
any equipment.
Figure 25: Lynx™ Mold-Closed Limit Switch side view
L-LS Installation
Step 1.
Switch the molding machine to Manual mode and close
the mold.
Step 2.
Set the limit switch on the tie-bar as shown in figures 26
and 27.
!
U
Be careful to note the position of the
ejector plate, the mold, the limit switch
and its cable, so the limit switch and/or
its cable does not get caught as the
mold opens and closes.
Appendix 32
eDART™ System User Guide
B
A
Figure 26: Lynx™ Mold-Closed Limit Switch front view
A Tie Bar
B Ty-Wrap
Table 25: Figure Labels
Step 3.
Slide the limit switch to the left until an audible click is
heard form the switch. See Figure 27.
B
A
C
Figure 27: Lynx™ Mold-Closed Limit Switch side view
L-LS
D
U
Always disconnect the power before
working on this or any electrical equipment.
A Moving Half
B Ejector Plate
C Tie Bar
D Slide
Appendix 33