Lynx LCB2-2, L27, L30, L36, L42 Care & Use/installation Manual

...
Page 1
MaKe tHe Most oF Your
siDe Burner accessorY
care & use/installation
Page 2
WARNING
READ THIS MANUAL CAREFULLY and completely before using your grill to reduce the risk of:
1. Fire
2. Burn hazard, personal injury or property damage
3. Ruined steaks or other unpleasant cooking experiences
4. Unapproved installation or servicing.
THIS PRODUCT IS DESIGNED FOR OUTDOOR USE ONLY. Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death.
Read this manual thoroughly before installation, use, or servicing of this product.
DANGER
IF YOU SMELL GAS:
1. Shut off all gas supply lines to the grill accessory.
2. Extinguish any open flames.
3. Carefully open the lid. Remember, it may be extremely hot!
4. If odor continues, keep everyone away from the grill accessory and immediately call your gas supplier or your fire department.
WARNING
1. DO NOT store or use gasoline or other flam­mable vapors and liquids in the vicinity of this or any other appliance.
2. An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance.
DANGER
S’IL Y A UNE ODEUR DE GAZ:
1. Coupez l’admission de gaz de l’appariel.
2. Éteindre toute flamme nue.
3. Ouvrir le couvercle.
4. Si l’odeur persiste, éloignez-vous de l’appareil et appelez immédiatement le fournisseur de gaz ou le service d’incendie.
AVERTISSMENT
1. Ne pas entreposer ni utiliser de l’essence ni d’autres vapeurs ou liquides inflammables dans le voisinage de l’appareil, ni de tout autre appareil.
2. Une bouteille de propane qui n’est pas raccordée en vue de son utilisation, ne doit pas être en­treposée dans le voisinage de cet appareil ou de tout autre appareil.
Warning! CALIFORNIA PROPOSITION 65
1. The burning of gas cooking fuel generates some by-products which are on the list of substances which are known by the State of California to cause cancer or reproductive harm.
2. California law requires businesses to warn customers of potential exposure to such substances. To minimize exposure to the substances, always operate this unit according to the use and care instructions found in this manual. Be certain to provide adequate ventilation when cooking.
3. California Proposition 65 lists “Silica, crystalline” which is used in one of the components of the IR burner, as an agent known to the state of California to cause cancer.
2
SIDE BURNER ACCESSORY CARE & USE/INSTALLATION
|
Page 3
HoW to liGHt Your Grill accessorY
1. Before each use, complete the checklist below.
2. Make sure all burner control knobs are in the “OFF” position.
3. Push and hold the control knob for 2-5 seconds, allowing the igniter to heat up.
4. Turn the knob to the “LITE” position.
5. After ignition set the knob to the desired setting.
cHecKlist BeFore eacH use (For Your saFetY)
•Do you smell gas? If yes, shut off everything and call the gas company or a qualified plumber to check for leaks, if not please continue.
•Are you prepared to stay with the side burner during the entire cooking process? If not, gather what you need be­fore starting the lighting process. If yes, please continue.
•Is your cooking area free and clear of any combustibles, besides your food, that might ignite? If no, clear the area before starting the lighting process, If yes, please con­tinue.
•Do all control knobs turn freely? If not, call for service; if yes, please continue.
•If you are using a portable propane cylinder, is it connect­ed and leak tested? If not, check the connection before continuing. If yes please continue.
•Do you know where your side burner’s main gas supply shut-off valve is located? If not, locate it before continu­ing. If yes, please continue.
•Are all burners properly seated in the side burner? If not, seat the burners properly before continuing. If yes please continue.
•Is the wind blowing just lightly and not blowing on the side burner? If not, wait until the wind subsides or turn your free-standing grill so the wind goes into the front of the grill. If yes, please continue with the lighting process.
PART NO. 33487 REV.B 3/13
SIDE BURNER ACCESSORY CARE & USE/INSTALLATION
3
|
Page 4
WARNING
•Never use dented, rusty or damaged propane cylinders. Never store additional or empty propane cylinders in the cabinet or in the vicinity of this or any other appliance. Do not store propane cylinders indoors or on their sides.
•Children should never be left alone or unattended in an area where an accessory is located. Place your accessory well away from areas where children play. Do not store items that may interest children in or around the area of your accessory, in your accessory cart, or in the masonry enclosure.
•Never move the accessory when hot. When in use, portions of the accessory are hot enough to cause severe burns.
•Always maintain the required clearances from combustibles as detailed. Accessories are designed for out­door use only. Never use in a garage, building, shed, breezeway, or other enclosed area. Do not use this equipment under any overhead combustible construction.
•Grill accessories are not designed or certified for and are not to be installed in or on recreational vehicles, portable trailers, boats or any other moving installation.
•Always have an ABC Fire Extinguisher accessible — never attempt to extinguish a grease fire with water or other liquids.
•Storing your accessory: Store your accessory in a well-ventilated area. If stored indoors, detach and leave LP cylinder outdoors in a well-ventilated area away from heat and away from where children may tamper with it.
•Keep any electrical supply cord and the fuel supply hose away from any heated surfaces. Electrical cords should be placed away from walkways to avoid tripping hazard.
•Do not repair or replace any part of the accessory unless specifically recommended in this manual. Other service should be performed by a qualified technician.
•If the accessory is installed by a professional installer or technician, be sure that he/she shows you where your gas supply shut-off is located. All gas lines must have a shut-off that is readily and easily accessible. If you smell gas, check for gas leaks immediately. Check only with a soap and water solution. (See INDEX: “Leak Testing” for further details.) Never check for gas leaks with an open flame.
•Inspect the LP gas supply hose prior to each use of the accessory. If there is evidence of excessive abrasion or wear, or the hose is cut, it must be replaced before using the accessory.
•Never remove the grounding prong from the plug or use this product with an ungrounded, 2-prong adapter.
THIS MANUAL MUST REMAIN WITH THE PRODUCT OWNER FOR FUTURE REFERENCE.
This product complies with ANSI standard Z21.58/CSA
1.6 latest edition and has been tested and approved by Intertek.
4
SIDE BURNER ACCESSORY CARE & USE/INSTALLATION
|
To obtain replacement parts or service contact:
Lynx Professional Grills 5895 Rickenbacker Commerce, CA 90040
888-289-5969
Page 5
a MessaGe to our custoMers
You’ve just joined the world of Lynx cooks … a discriminating collection of amateur and professional chefs that take outdoor cooking to a new level.
Lynx manufactures many accessory cooking appliances to compliment your Lynx grill and your desire for truly superior cooking results.
Your appliance has been designed and built with meticulous attention to detail and it offers some unique and powerful features. You can achieve maximum performance and enjoyment of these features only by carefully reading this manual ... before your first cook-out.
This manual includes important safety tips and great hints for better grill­ing. You should keep it handy for easy reference.
Also, at Lynx, we enjoy hearing from our customers. We like to hear about your successes but also about any difficulties you are having. Please feel free to contact us with any questions or problems, or just to share a new recipe. Please include the model number of your appliance in your corre­spondence.
With the proper use and care this product will provide years of trouble-free service.
Should your Lynx appliance change ownership, please make sure that the new owner receives this manual.
Thanks again for your purchase. Enjoy!
SIDE BURNER ACCESSORY CARE & USE/INSTALLATION
5
|
Page 6
WARNING
1. The outdoor cooking gas appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 0.5 psi (3.5 kPa).
2. The outdoor cooking gas appliance must be isolated from the gas supply piping system by closing its indi­vidual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.5 kPa).
STATE OF MASSACHUSETTS
1. Massachusetts requires all gas be installed using a plumber or gas fitter carrying the appropriate Massachu­setts license.
2. All permanently-installed natural gas or propane installations require a “T” handle type manual gas valve be installed in the gas supply line to this appliance.
3. This does not apply to portable propane installations using a 20 pound cylinder.
WARNING - ELECTRICAL GROUNDING
•Product installation must meet local electric codes or, in the absence of local codes, the latest edition of the
National Electrical Code ANSI/NFPA No. 70 or the Canadian Electrical Code CGA 1.6b2005.
•Use only a Ground Fault Interrupter (GFI) protected circuit with this outdoor cooking gas appliance.
•This accessory is equipped with a three prong (grounding) electric plug for your protection against shock hazard
and must be plugged directly into a properly grounded three prong outlet. Never cut or remove the grounding prong from this plug.
•Use only extension cords with a 3 prong grounding plug, rated for the power of the equipment, and approved
for outdoor use with a “W-A” marking.
•To protect against electric shock, do not immerse any part of the power cord, an extension cord or any plugs in
water or other liquid.
•Unplug the product from the outlet when not in use and before cleaning. Allow it to cool before putting on or
taking off parts.
•Do not let the cord hang over the edge of a table or touch hot surfaces.
•Do not operate any outdoor cooking gas appliance with a damaged cord, plug, or after the appliance malfunc-
tions or has been damaged in any manner. Contact the manufacturer for repair.
6
SIDE BURNER ACCESSORY CARE & USE/INSTALLATION
|
Page 7
iMportant saFetY precautions
Please review these imPortant safety Precautions before you use your grill accessory.
1. NEVER LEAVE THE GRILL ACCESSORY UNATTENDED WHILE COOKING.
2. Ensure all tie-down wires have been removed from the burners.
3. Always use caution when operating the grill accessory in a windy area. (See INDEX: “Grilling in Windy Condi­tions” for further details.)
4. Avoid wearing loose-fitting garments or long sleeves while grilling. They could ignite.
5. Never touch the grill accessory racks or immediate surrounding metal surfaces with your bare hands while grilling.
6. Use an insulated glove or mitt when opening and oper­ating the grill accessory.
7. The grill accessory covers must be fully removed or opened while lighting the grill accessory. Releasing fuel into a closed grill accessory before lighting will not make it light sooner or more efficiently. It will only risk explosion and personal injury or death. Never lean over hot grill accessory surface or look directly into the grill accessory when attempting to light.
8. Do not heat unopened food containers as pressure build-up will cause the container to explode.
9. Do not use aluminum foil to line grill accessory racks or drip pans. This will alter the airflow or trap exces­sive heat in the control area and can melt knobs and ignition modules. Such damage is specifically excluded from your warranty.
10. Never use charcoal or any other solid fuel in the grill accessory.
11. Cooking excessively fatty meats and oils will cause flare ups. Internal fires or damage caused by them or by the grill accessory being left unattended while cooking are not covered under the terms and conditions of our warranty.
12. Never grill without a drip pan in place if your accessory utilizes a built-in drip pan. Always ensure the drip pan is pushed all the way to the back of the grill accessory. When not correctly in place, hot grease can leak down­ward and produce a fire or explosion.
13. Grease is extremely flammable. Let hot grease cool down before attempting to handle or dispose of it. The drip tray should be cleaned of grease on a regular basis.
14. Do not use the grill accessory unless a leak check has been performed on all gas connections. (See INDEX: “Leak Testing” for further details.)
15. Never operate the grill accessory while under the influ­ence of alcohol or drugs.
16. Do not lean on side shelves and never place a load weighing more than 25 pounds on a side shelf.
17. If any burner does not light or goes out during opera­tion, turn off all gas control knobs and wait five (5) minutes before attempting to re-light.
SIDE BURNER ACCESSORY CARE & USE/INSTALLATION
7
|
Page 8
taBle oF contents
A MESSAGE TO OUR CUSTOMERS 5 IMPORTANT SAFETY PRECAUTIONS 7 USING YOUR LYNX ACCESSORY 9
Accessories Covered in this Manual 9
USING THE LYNX POWER BURNER (LPB) 10
Smell of Gas While Cooking 10 Yellow Flames 10
LIGHTING INSTRUCTIONS FOR ALL ACCESSORIES 11
Safety Practices and Precautions 11 At Each New Season 11 Purging the Gas Lines 11 Match Lighting 11 Low Heat Flame Adjustment 12
CONTACTING LYNX CUSTOMER CARE 13 BEFORE YOU START 14
If Shipment Arrives Damaged 14
Visible Loss or Damage 14 Concealed Loss or Damage 14
Important Notes 14
Where’s the Wind? 14 How Long is Your Run? 14 Are You “On-the-Level”? 14 Built-in Installations 15 Clearance to Combustible Materials 15
GAS & ELECTRIC CONNECTIONS 16
Gas Plumbing 16
Natural Gas 16 LP Gas 17
LP Connections 17 Propane Hook Up 18 Natural Gas Hook Up 18
Maximum Runs for all appliances on supply line 18 Electrical Connections 19
Optional Electrical Kits 19
Connecting the Wiring 19 Testing the Installation 20
Leak Testing 20
Fixing a Gas Leak 20
SCHEMATICS 21 SPECIFICATIONS & INSTALLATION 22 LYNX LIMITED WARRANTY 24 LYNX COMMON AREA LIMITED WARRANTY 25 SIDE BURNER EXPLODED PARTS VIEW 26 INDEX 27
8
SIDE BURNER ACCESSORY CARE & USE/INSTALLATION
|
Page 9
Accessories covered in this MAnuAl
usinG Your lYnX accessorY
This manual covers several Lynx accessory appliances and optional accessories for those appliances.
Except where noted, the assembly, installation and use of these Lynx accessories is identical.
POWER BURNER
MODEL LBP The Lynx Power Burneris a dual-ring commercial style
burner with a range of 3,000 to 47,000 BTU’s.
PREP CENTER
MODEL LSBPC-1 The LSBPC-1 Prep Center Features two 15,000 BTU burners
and an integral bamboo cutting board for food prep.
SIDE BURNER 1 & 2
MODELS LCB1-2 & LCB2-2, LSB1-2 & LSB2-2 The LCB1-2 & LCB2-2, LSB1-2 & LSB2-2 (Lynx Side Burner
1 & 2) features either one or two 15,000 BTU burners for cooking smaller food items. The LCB1-2 & LCB2-2 can be mounted directly to most Lynx grills. For the 27” and 36” Lynx grills with smaller depths, a LCB-BKT adapter is avail­able. The LSB1-2 and LSB2-2 are designed for installation in a non-combustible, built-in enclosure.
SIDE BURNER ACCESSORY CARE & USE/INSTALLATION
9
|
Page 10
The Lynx Power Burner incorporates a cast brass, dual-
USING THE LYNX POWER BURNER (LPB)
IF YOU SMELL GAS WHILE THE GRILL ACCES- SORY IS OPERATING, IMMEDIATELY TURN OFF ALL BURNERS AND SHUT OFF THE MAIN FUEL SUPPLY.
ring, burner.
Each ring can be independently operated for maximum heat control. Used together they can generate up to 47,000 BTU’s.
SMELL OF GAS WHILE COOKING
WARNING!
•Perform a leak test (See INDEX: “Leak Testing” for further details.)
•Check for blockages.
YELLOW FLAMES
A yellow flame on the main burners indicates a lack of air. But, if the air around the grill is dusty or if heavy grease is present, some orange tips on the burner flame are normal.
•ADJUST THE AIR SHUTTER
The knob on the left controls the outer burner ring and the knob on the right controls the inner burner ring.
The Hot Surface ignition system provides reliable ignition.
The main grate can easily handle oversized stock pots and removing the center grate accommodates a commercial style round-bottom wok base (12 inch minimum).
The Lynx Power Burner also features a fully extendable stain­less steel drip pan.
ONLY DO THIS WHEN THE ACCESSORY HAS COOLED DOWN COMPLETELY! Make sure all grill controls are in the “OFF” position.
1. Remove the cooking grates.
2. Reach under the drip guard and rotate the air shutters
to adjust.
10
SIDE BURNER ACCESSORY CARE & USE/INSTALLATION
|
3. Ensure that the burner is seated correctly on the frame,
with the brass peg seated inside the positioning hole.
4. Re-light and check the flame.
Page 11
SAFETY PRACTICES AND PRECAUTIONS
Lighting instructions for ALL Accessories
WARNING
Read the ‘User Manual/Installation Instructions carefully and completely before using your grill or grill accessory to reduce the risk of fire, burn hazard or other injury.
Ensure that burner ties and all packing materials are re­moved before lighting any new accessory.
AT EACH NEW SEASON
At the start of each new grilling season you should remove the cooking grates and check the burners, venturis, orifices and valves for obstructions.
PURGING THE GAS LINES
You should purge the gas line of air before attempting to light the grill accessory.
1. Make sure all grill controls are in the “OFF” position.
2. Slowly turn on the main gas supply.
3. Push in the control knob for the burner furthest from
the fuel source. Using the burner furthest from the fuel source will completely purge the lines. It will take sev­eral seconds for the burner to light.
4. Hold the knob ON for about 20 seconds to allow the
air in the system to purge and the burner to light
5. Wait at least 5 minutes after shutting off the control
before attempting to light the burners.
MATCH LIGHTING
If a burner fails to light after several attempts, it can be match lit. If you’ve just attempted to light the burner with the igniter, allow 5 minutes for any accumulated gas to dis­sipate before match lighting.
Make sure all knobs are in the OFF position. Keep your face as far away from the burner as possible.
Spiders and insects often nest in these areas of the acces­sory and can disrupt air flow, causing damage to the acces­sory and personal injury.
Also, check all hoses and fittings for damage, abrasion, wear and tear and repair, if necessary, before turning the gas on.
Replacement pressure regulators and hose assemblies, must be the type specified by Lynx. The pressure regulator and hose assembly supplied with the unit must be used.
If the unit is LP, screw the regulator into the tank and leak check the hose and regulator connections with a soap and water solution before operating the burner. Turn all knobs to OFF then SLOWLY turn on the gas supply valve.
Do not use any grill accessory if you smell gas.
Using the manual lighting rod, pass a lit match over the ports of the burner. The LYNX Power Burner features a lighting rod as shown above.
Push and turn the control knob of the burner to ‘Lite”. If the burner does not light in 4 seconds, turn the knob off and wait 5 minutes before attempting again.
SIDE BURNER ACCESSORY CARE & USE/INSTALLATION
11
|
Page 12
LOW HEAT FLAME ADJUSTMENT
Lighting instructions for ALL Accessories ...continued
The burners on your Lynx accessory feature an adjustable low setting.
Fluctuations in gas pressure, gas conversion and even in the quality of the gas itself may affect burner performance at the “LOW” setting. It could be either too high or too low.
To adjust the burner for low setting:
1. Make sure the grill accessory is cool.
2. Remove the grates so that you can see the flame while adjusting the burner.
3. Light the burner and set it to “LOW”. (all the way coun­ter- clockwise).
4. Pull off the control knob.
5. While holding the valve shaft with pliers, insert a thin flat-blade screwdriver into the shaft and, while watching the flame, adjust it to a minimum stable setting.
Use a small screwdriver for low setting burner adjustment.
12
SIDE BURNER ACCESSORY CARE & USE/INSTALLATION
|
Page 13
contactinG lYnX custoMer care
Before calling Lynx Customer Care, please make sure you have the following information:
•Model number
•Date of purchase
•Proof of purchase by the original owner
•Serial number
The serial number can be located on the rating plate stick­er. You may have a sticker on the back page of this manual. If not, you will find one located either on the underside of the drip tray (if you have one), on the heat shield behind the front panel, or on the inside left panel wall.
For warranty service, contact the Lynx Customer Care Department for an authorized service agent near you at:
Your satisfaction is of the utmost importance to us. If a problem cannot be resolved to your satisfaction, please write, fax or email us:
Lynx Professional Grills 5895 Rickenbacker Commerce, CA 90040 Lynx Customer Care: (888) 289-5969 Tel: (323) 838-1770 Fax: (323) 838-1778 www.lynxgrills.com
Contact Lynx for replacement parts. Parts are shipped F.O.B. Commerce, CA.
(888) 289-5969
www.lynxgrills.com
SIDE BURNER ACCESSORY CARE & USE/INSTALLATION
13
|
Page 14
BeFore You start
Important notes
Where’s the Wind?
When selecting a suitable location, consider important fac- tors such as exposure to the wind and foot-traffic patterns.
If you have a freestanding grill, position it so the prevailing wind blows into the front control panel (at your back when grilling), supporting the proper front-to-rear airflow.
Built-in accessories located in areas with prevailing winds should be protected by a wind barrier.
hoW Long is Your run?
Keep all gas supply lines as short as possible because gas lines lose pressure over distance and with each elbow and tee that is added. This drop in pressure affects accessory performance. (See INDEX: “Gas Supply Line Runs” for further details.)
Are You “on-the-LeveL”?
Proper leveling during installation is critical. An accessory that is out of level will cause erratic burner combustion and inefficient, uneven heating. A carpenter’s spirit level should be used to level the accessory both front-to-back and side- to-side.
If the floor is uneven or has a decided slope, re-leveling may be required each time you move a freestanding unit.
WARNING
•Never install this product into a combustible enclosure. Doing so could result in fire, property damage and per­sonal injury.
•Never locate the accessory under a roof or overhang, in a building, garage, shed or other such enclosed area.
•Always maintain the required clearances from combustibles as detailed. Accessories are designed for outdoor
use only. Never use in a garage, building, shed, breezeway, or other enclosed area. Do not use this equipment under any overhead combustible construction.
•Installation must conform with local codes or, in the absence of local codes, with either the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or Natural Gas and propane Installation Code, CSA B149.1, or Propane Storage and Handling Code, B149.2, in Canada.
iF sHipMent arriVes DaMaGeD
VISIBLE LOSS OR DAMAGE
Be certain any visible damage to the carton is noted on freight bill or express receipt and signed by the person making delivery.
FILE CLAIM FOR DAMAGES IMMEDIATELY, regardless of extent of damage.
CONCEALED LOSS OR DAMAGE
If damage is unnoticed until the accessory is unpacked, no­tify the transportation company or carrier immediately and file a “concealed damage” claim with them. This should be done within (15) days of the date delivery is made to you. Be sure to hold on to the container for inspection. We cannot assume responsibility for damage or loss incurred in transit. (See INDEX: “Obtaining Service from Lynx” for further details.)
14
SIDE BURNER ACCESSORY CARE & USE/INSTALLATION
|
Page 15
BUILT-IN INSTALLATIONS
Before you start...continued
CLEARANCE TO COMBUSTIBLE MATERIALS
Lynx built-in accessories are intended for installation in a built-in enclosure constructed of non-combustible materials.
The accessory drops into the opening shown in the cutout detail drawing and hangs from its counter-top trim. A deck is not required to support it from the bottom.
Pay special attention to the provisions shown for gas line hook-up. (See INDEX: “Cut-out Dimensions for Built-in Grills & Accessories”)
Installation provisions may be made for the Power Burner installation. The Power Burner cooking height may be reduced to better accommodate large cooking pots. Clear­ances to combustible material must be maintained as out­lined below. No combustible material shall be used in the construction of a counter top using a recessed application.
The enclosure should have ventilation holes to prevent gas build-up in the event of a leak. The deck ledges and counter should be flat and level. (Refer to ANSI Z21.58 Standard for Outdoor Cooking Gas Appliances, Section 1.7 Enclosures For Self Contained LP-Gas Supply Systems or local codes for additional information.)
Minimum clearance from the sides and back of the acces­sory to adjacent combustible construction below the top of unit are 12” from the sides and back.
Dégagement minimal entre les parois latérales et l’arrière de l’appariel et la construction combustible au-dessous du panneau supérieur de l’appareil (30 cm à partir des parois latérales et 30 cm à partir de l’arrière).
Minimum clearance from sides and back of unit to adjacent combustible construction extending above the unit is 18” from the sides and back.
Dégagement horizontal minimal entre les parois laté­rales et l’arrière de l’appariel et la construction verticale combustible au-dessus de l’appareil (45.7 cm à partir des parois latérales et 45.7 cm à partir de l’arrière).
Do not use this appliance under overhead combustible surfaces.
Ne pas utiliser cet appareil sous une surface combustible.
The grill accessory may be powered from either a 120 volt, 60 hertz, 15 amp GFI certified outlet installed by a qualified electrician OR it may be powered directly from your Lynx Grill transformer power supply.
When a Lynx grill is not available or if the grill is not located close enough to the grill a Lynx LASK (Lynx Accessory Switch Kit) is available as an optional purchase.
SIDE BURNER ACCESSORY CARE & USE/INSTALLATION
15
|
Page 16
WARNING
Never connect a gas line directly to the accessory. A pressure regulator must be installed on all gas equipment. All local codes require it and Lynx supplies the correct regulator with your accessory. Removing or failing to install the pressure regulator can result in fire and serious personal injury and will void the warranty.
Gas PlumbinG
Gas & electric connections
Keep last two threads clean
The accessory is factory set to use either propane (LP) or natural gas (NAT). It is critical that the gas you use matches that which the accessory was set up for. You can verify that by checking the rating plate.
The rating plate is located on the heat shield behind the front panel.
Ensure that the gas supplied meets with the minimum pres­sure requirements.
Do not operate the accessory on any gas other than that for which the accessory has been set.
Fuel WC Max Inlet WC Min Under Full
Load
Nat Gas 7 in 4 in
LP 14 in 10 in
NATURAL GAS
Lynx recommends that only qualified professionals perform the required plumbing on this product.
The gas supply line must be sized to accommodate the total BTU requirements of all the gas-fired equipment that will be connected to that line.
In no case should pipe less than 3/4” inside diameter or 1” outside diameter be used.
•Calculate the total BTU output of all equipment and refer to “INDEX: Gas Supply Line Runs” for allowable run distances. Failure to meet these minimum requirements may reduce performance of the accessory and any other appliances running on that supply line.
•Always keep supply line runs as short as possible. (See INDEX: “Gas Supply line runs”)
•A gas shut-off valve must be installed in an easily acces­sible location by a qualified plumber.
Water Column Requirements
Both the regulator and the manifold orifices have been tuned for the type of gas specified on the rating plate.
Converting to a different type of gas requires a conversion kit which is included with your side burner accessory and must be installed by a qualified technician.
All installation and all installation parts must conform to local codes with the National Electrical Code, ANSI/NFPA 70-1990 and the National Fuel Gas Code, ANSI Z223.1/ NFPA 54 in the U.S. and CGA-B149.1/.2 in Canada.
Canadian installations must conform to CGA-B149.1/.2 natural gas/propane installation code. (Canada)
16
SIDE BURNER ACCESSORY CARE & USE/INSTALLATION
|
•Keep any threading compound off of the first two pipe threads to avoid having any small pieces of compound break loose and clog a burner valve or orifice. Do not put sealant on any male end of flare fittings.
For built-in installations, it is recommended that any flexible pipe used be kept as short as possible. (See INDEX: “Gas Connections” for typical permanent hook up.)
Page 17
LP Gas
Accessories set up for LP gas come equipped with an LP hose/ regulator assembly for connection to a standard 20 lb. LP cylinder. (Type 1).
All fittings necessary to attach the assembly to the accessory are included.
Permanently plumbed LP connections, such as those in line with a bulk cylinder, require a 4/11 regulator. (Lynx P/N
30781)
When using the 4/11 regulator you must ensure that it is set for the proper fuel type. This is done by removing the regulator cap and gasket and looking at the bottom of the plunger to see what fuel type is visible. This is the regula- tor fuel setting. NAT is for natural gas and LP is for propane gas. The LP setting can be further identified by the large diameter disk on the bottom of the plunger. To change from one gas to the other simply push the plunger to the side to snap it out of the cap, turn the plunger so it reads the desired gas type on the bottom, and push the plunger until it snaps back into place in the cap then replace the cap into the regulator.
Never connect an unregulated gas line to the grill.
When exchanging your cylinder for a refill, exchange only for a Type 1 20lb cylinder with an over-fill protection device.
Never use a cylinder with a damaged valve.
A dented or rusty LP cylinder may be hazardous and should be avoided. If in doubt, have it checked by your LP supplier.
Always check for leaks after every LP cylinder change. (See INDEX: “Leak Testing” for further details.)
Always shut off the LP-gas supply at the cylinder when the accessory is not in use.
Cylinders must be stored outdoors in a well-ventilated area out of the reach of children. If your accessory is stored in- doors, the LP cylinder must be stored outside.
LP ConneCtions
Make sure the LP cylinder valve is fully closed. It is possible for the valve to be open without releasing gas but, as soon as you start connecting the regulator, gas will leak from the connec- tion.
Insert the regulator inlet into the cylinder valve and turn the black coupler clockwise until the coupler is hand tight. Do not over-tighten this connection.
To disconnect the coupler, first make sure the main cylinder valve is turned off. Grasp the coupler and turn counter clock- wise. Always leak-test the connection after refilling or exchang- ing LP cylinders. (See INDEX: “Leak Testing” for further details.)
Gas & electric connections ...continued
LP cylinder with type 1 valve connection
SIDE BURNER ACCESSORY CARE & USE/INSTALLATION
17
|
Page 18
PROPANE HOOK UP NATURAL GAS HOOK UP
Gas & electric connections ...continued
COLD WEATHER WARNING: PROPANE Extremely cold temperatures may cause your burner
to light inside the burner instead of outside. Once lit, if you hear a ‘whooshing’ sound, immediately turn the burner knob off to extinguish the flame and then immediately re-light the burner.
propAne hook up nAturAl gAs hook up
WARNING
18
SIDE BURNER ACCESSORY CARE & USE/INSTALLATION
|
MAXIMUM RUNS FOR ALL
APPLIANCES ON SUPPLY LINE
Run Length
3/4” Pipe (in feet)
10 360,000
20 245,000
30 198,000
40 169,000
50 150,000
60 135,000
70 123,000
80 115,000
Max BTU for all
Appliances on line
Page 19
OPTIONAL ELECTRICAL KITS
ElEctrical connEctions
Each accessory includes 6 feet of wiring (coiled inside the back of the accessory) to connect the accessory to a Lynx grill. Additionally, Lynx manufactures 2 specialized electrical kits that you may purchase for your accessory, depending upon how it will be installed. Each electrical kit ships with an instructional sheet for assembly. Assembly instructions and sche­matics/drawings can also be found on our website at www.lynxgrills.com
.
•LASK Lynx Accessory Switch Kit
•LPEK Lynx Power Extension Kit
Installation requires an outdoor 120VAC 15A GFI (Ground Fault Interrupter) electrical outlet adjacent to the accessory.
The GFI outlet features an internal breaker that reduces shock hazard. This type of outlet should be installed by a qualified electrician either inside the island enclosure for built-in units, or near the location where a free-standing unit will be used.
For built-in accessories, the supplied 12V transformer is connected to the accessory during installation.
If the electrical system fails to operate, a connection may have come loose in shipping or the GFI may have tripped, requiring a reset. See the Troubleshooting section for more details.
This switch and transformer kit allows independent control of a Lynx accessory burner without connection to a grill. The kit contains a transformer and mounting bracket as well as a switch assembly with a mounting plate. The kit also contains a wiring harness to adapt an L series accessory to an M series switch and trans­former.
The Lynx Power Extension Kit provides 12 feet of additional wire between your Lynx Grill and accessory burner.
CONNECTING THE WIRING
The accessory electrical harnesses are designed to provide power for both ignition and lighting. While ignition is con­trolled at the accessory, lighting is controlled at the grill.
You can control lighting at the accessory by installing the Lynx Accessory Light Switch (LASK).
Disconnect the 4-pin connector on the grill and connect those plugs to the mating plugs on your accessory. (See Index “Electrical Connections)
Important note: If using multiple Lynx accessories with the Control Illumination/Blue LED’S, a connector for this pur­pose is built into the accessory wiring. This will allow you to use the light switch on your Lynx grill to actuate the power on more than one accessory.
SIDE BURNER ACCESSORY CARE & USE/INSTALLATION
19
|
Page 20
TesTing The insTallaTion
Before turning the gas supply on, check for proper installa- tion using the following test:
1. Plug the transformer back into the receptacle.
2. Push in the gas control knob on your accessory and watch the igniter. It should glow bright and steady.
3. Turn on the light switch on the grill. Both the grill and the grill accessory lights should operate together. This indicates a proper assembly.
Turn the gas on to all appliances.
4. Perform a leak test if you have not done so since plumbing the unit.
5. Check all burners for proper ignition. Refer to the Light- ing Instructions for Side Burners.
Leak TesTing
Leak Test Procedure:
1. Create a soapy solution of 1 part soap and 3 parts water.
2. Confirm that all control knobs are in the off position.
3. Turn on the fuel supply. For natural gas, turn the valve handle 1/4 turn to align with the gas flow.
4. For LP, turn the cylinder valve knob counter clockwise one full rotation.
5. Apply the soap solution generously by paint brush or squirt bottle on all connections and fittings.
6. If bubbles appear to “grow” on any of the connections, you have a gas leak. IMMEDIATELY turn off the gas supply.
Fixing a gas Leak
To prevent fire or explosion hazard, DO NOT smoke or allow any potential source of ignition (sparks, electrical arcing, etc) in the area while performing a leak test. Leak tests should be conducted outdoors only. Never conduct a leak test using fire or flame.
1. Shut off the gas supply
2. Turn all grill controls to the “ON” position to purge the grill of any gas build-up, then turn the controls back “OFF”.
3. Wash off the soapy solution with cold water and dry.
4. Tighten the loose joint, or replace the faulty part with manufacturer-recommended replacement parts.
5. DO NOT attempt to repair the LP cylinder valve if it is damaged. The only way to safely resolve a damaged cylinder is to REPLACE IT.
6. Repeat the leak test to ensure that no leaks are present.
DANGER!
20
SIDE BURNER ACCESSORY CARE & USE/INSTALLATION
|
Page 21
SCHEMATICS
WHITE
SIDE BURNER ACCESSORY CARE & USE/INSTALLATION
21
|
Page 22
The guides, measurements and dimensions detailed below are designated to assist you with planning your outdoor kitchen.
SPECIFICATIONS & INSTAllATION
NOTE: Due to continuing product innovation, specifications are subject to change without notice. IMPORTANT: Please reference the Care & Use / Installation manual for details on gas plumbing requirements, electrical specifications and the
proper installation of your Lynx outdoor kitchen equipment. This manual can be downloaded from the Lynx website at www.lynxgrills.com
Grills
MODEL A B C
L27 26.00 10.88 22.00 L30 29.00 10.88 24.50 L36 35.00 10.13 22.00 L42 41.00 10.88 24.50 L54 53.00 10.88 24.50
coMpleMentarY proDucts
ACCESS DOORS
MODEL A B
LDR21-1 19.25 19.00 LDR27-1 25.25 19.00 LDR30-1 28.25 19.00 LDR36-2 34.25 19.00 LDR42-1 40.25 19.00 LDR36T 31.63 19.00 LDR42T 37.63 19.00
SIDE BURNERS
MODEL
LSB1 12.13 10.63 24.50 LSB2 12.13 10.63 24.50 LSB2PC 24.25 10.63 24.50 LPB 19.00 10.63 22.00
A B C
WitH insulateD jacKet installeD
MODEL A B C
LIJ27 33.00 11.63 24.00 LIJ30 36.00 11.63 26.50 LIJ36 42.00 11.63 24.00 LIJ42 48.00 11.63 26.50 LIJ54 60.00 11.63 26.50
STORAGE SYSTEMS
MODEL A B C
LSA30 28.25 19.00 24.50 LSA36 34.25 19.00 24.50
TRASH CENTERS
MODEL A B C
L18TC 16.00 24.00 13.00 L20TR 16.81 24.00 24.75 LTA530 28.25 19.00 20.00
3”
UTILITY DRAWERS
MODEL A B C
LUDE 12.13 19.25 24.00 LUDXL 17.25 18.57 24.25 LDW19 17.50 19.00 24.50 LMD 21.75 5.63 23.38
WARMING DRAWERS
MODEL A B C
L30WD 28.50 10.00 20.50 L42CC 40.25 19.38 24.50
COCKTAIL PRO
MODEL A B C
CS30 29.00 10.63 22.75
22
SIDE BURNER ACCESSORY CARE & USE/INSTALLATION
|
Only required if island counter top overhangs the face of the island
COUNTER TOP NOTCH DETAIL
AA
5”
4.5”
C
3”
B
Page 23
outDoor reFriGerators
1
1/8
” min. for model LUDE
3
1/2
” min. for model LUDXL
2
1/2
” min. for model LDR (access door)
* Cocktail Pro should have an open bottom for plumbing and drain access. ** 1” square hole must be located at rear of grill cutout. 120V GFI outlet must be located within 6’ of the 1” hole.
1/2” NPT gas connection
CLEARANCE
33
1/2
34”
15”
25”
ICE MACHINE
3”
2”Ø or 2” square holes
for manifold connection
(rear or bottom access)
12” min.
Grill**
Cocktail Pro*
Warming Drawer/ Convenience Center
Utility Drawer
Side Burner
Drop In Cooler (LDC18)
Access Doors
A
B
2
1/4
3
1/2
3
1/4
” min.
2”
3” min.
C
Trash Center
36
3/8
min.
3
1/2
8
1/4
18
1/4
6
1/4
18
1/4
Trash Chute (L18TS)
2
3/
16
''
13 ''
Single Storage Drawer
3”
min.
14
1/2
''
8
1/4
''
Towel Dispenser (L16TWL)
A
A
A
A
A
B
B
B
B
A
B
B
A
min.
max.
a
e
d
f
c
b
SPECIFICATIONS & INSTAllATION
MODEL A B C D
L24REF 24.25 33.00 26.00 32.00 L24BF 24.25 34.50 26.00 34.25 L24DWR 24.25 34.50 26.00 34.25 L15ICE 15.25 34.00 26.00 33.50
A
C
B
A
C
B
D
D
SIDE BURNER ACCESSORY CARE & USE/INSTALLATION
23
|
Page 24
lYnX liMiteD WarrantY
I. Limited Lifetime Warranty
The stainless steel grill body, brass grill burners, ProSear™ burner and rotisserie infrared burner are warranted to be free from defects in material and workmanship when subjected to normal domestic use and service for the lifetime of the original purchaser. This warranty excludes surface corrosion, scratches, and discoloration which may occur during normal use. This warranty is limited to the replacement of the defec­tive parts, with the owner paying all other cost including labor, shipping and handling.
II. Limited Five-Year Warranty
The following grill parts are warranted to be free from de­fects in material and workmanship, when subjected to normal domestic use and service, for a period of five (5) years from the original date of purchase; cooking grates, warming racks, spit rods, briquette trays, manifolds and gas valves. This warranty is limited to the replacement of the defective parts, with the owner paying all other costs including labor, ship­ping, and handling.
III. Limited Two-Year Warranty
All other grill components are warranted to be free from de­fects in material and workmanship, when subjected to normal domestic use and service, for a period of two (2) years from the original date of purchase. This warranty is limited to the replacement of the defective parts, with the owner paying all other costs including labor, shipping and handling..
IV. Limited One-Year Warranty.
For a period of one (1) year from the original date of pur­chase, Lynx will replace or repair parts found to be defective at no cost to the original purchaser. This includes the cost of shipping replacement parts and, where necessary, service labor at prevailing local rates by a Lynx authorized service person. Service will be provided during normal business hours and must be authorized in advance by Lynx.
IV. Limitations & Exclusions
1) This Warranty shall apply to products purchased and located in the United States and Canada. Products must be purchased in the country where service is requested.
2) Warranty applies only to the original purchaser and may not be transferred.
3) Warranty is in lieu of all other warranties expressed or implied and all other obligations or liabilities related to the sale or use of its grill products.
4) Warranty shall not apply and Lynx is not responsible for damage resulting from misuse, abuse, alteration of or
tampering with the appliance, accident, hostile environ­ ment, flare-up fires, improper installation, or installation not in accordance with the instructions contained in this manual, or the local codes.
5) Lynx shall not be liable for incidental, consequential, special or contingent damages resulting from its breach of this written warranty or any implied warranty.
6) Some states do not allow limitations on how long an implied warranty lasts, or the exclusions of or limitations on consequential damages. This warranty gives you specific legal rights and you may have other rights which vary from state to state.
7) No one has the authority to add to or vary Lynx’s warranty, or to create for Lynx any other obligation or liability in connection with the sale or use of its products.
8) Limited to the replacement of defective parts with the owner paying all other costs including labor.
V. What is not covered: Lynx shall not be responsible for and shall not pay for the following:
1) Installation or start-up, damages or problems caused by improper installation or use;
2) Service by an unauthorized service provider;
3) Damage or repair due to service by an unauthorized service provider or use of unauthorized parts;
4) Warranty does not apply to products installed in any commercial or non-residential application. Examples of excluded applications include, but are not limited to day care centers, schools, bed and breakfast centers, churches, private clubs, fire stations, club houses, common areas in multi-family dwellings, restaurants, hotels, nursing homes, food service locations and institutional food service locations.
5) To correct normal adjustments or settings, due to improper installation, commissioning or local gas supply properties.
6) Shipping and handling costs, export duties, installation, removal, or re-installation cost.
7) Display models are sold “as is”. If you have purchased a display model, please be advised that it is sold “as is” and that it is subject to the following warranty exclusions: any exterior or cosmetic damage is non-warrantable; any missing components will be replaced at consumer’s expense; major handling damage to manifold, valve and ignition system will be serviced at consumer’s expense; all other warranty’s (standard warranty) will remain in effect.
8) The cost of a service call to diagnose trouble.
24
SIDE BURNER ACCESSORY CARE & USE/INSTALLATION
|
Page 25
lYnX coMMon area liMiteD WarrantY
The Lynx Limited Warranty covers residential installations only and is non-transferable to any other party. This ‘non­residential’ warranty applies when the product is installed in common areas where more than a single party has rightful access to its use or in locations considered beyond normal residential use such as B&B’s, and private clubs.
THIS PROVISION EXCLUDES ALL COMMERCIAL APPLICA­TIONS, INCLUDING, BUT NOT LIMITED TO RESTAURANTS AND INSTITUTIONAL FOOD SERVICE LOCATIONS.
I. Limited Five-Year Warranty
The stainless steel body housings, the solid brass grill burn­ers are warranted to be free from defects in material and workmanship when subjected to normal use and service for a five year period from the original purchase date. This war­ranty excludes surface corrosion, scratches, and discoloration which may occur during regular use. This warranty is limited to the replacement of the defective parts, with the owner paying all other cost including shipping, handling and labor.
II. Limited One-Year Warranty
The structural integrity of the interior grill parts, exterior, and drip pans are warranted to be free from defects in mate­rial and workmanship, when subjected to normal domestic use and service, for a period of one year from the date of purchase. This warranty is limited to the replacement of the defective parts, with the owner paying all other costs includ­ing labor.
III. Limited Parts & Labor Warranty
All other grill components are warranted to be free from defects in material and workmanship for a period of 90 days from the original date of purchase. Lynx will replace or repair parts found to be defective at no cost to the original purchaser. After the 90 day period Lynx will sell parts to the holder of this warranty at Lynx contractor prices for an ad­ditional 9 months.
IV. Limitations & Exclusions
1) This Warranty shall apply to products purchased and located in the United States and Canada. Products must be purchased in the country where service is requested.
ment, flare-up fires, improper installation, or installation not in accordance with the instructions contained in this manual, or the local codes.
5) Lynx shall not be liable for incidental, consequential, special or contingent damages resulting from its breach of this written warranty or any implied warranty.
6) Some states do not allow limitations on how long an implied warranty lasts, or the exclusions of or limitations on consequential damages. This warranty gives you specific legal rights and you may have other rights which vary from state to state.
7) No one has the authority to add to or vary Lynx’s warranty, or to create for Lynx any other obligation or liability in connection with the sale or use of its products.
8) Limited to the replacement of defective parts with the owner paying all other costs including labor.
V. What is not covered: Lynx shall not be responsible for and shall not pay for the following:
1) Installation or start-up, damages or problems caused by improper installation or use;
2) Service by an unauthorized service provider;
3) Damage or repair due to service by an unauthorized service provider or use of unauthorized parts;
4) To correct normal adjustments or settings, due to improper installation, commissioning or local gas supply properties;
5) Shipping and handling costs, export duties, installation, removal, or re-installation cost.
6) Display models are generally sold “as is.” If you have purchased a display model, please be advised that it is sold “as is” and that it is subject to the following warranty exclusions: any exterior or cosmetic damage is non­ warrantable; any missing components will be replaced at consumer’s expense; major handling damage to manifold, valve and ignition system will be serviced at consumer’s expense; all other warranty’s (standard warranty) will remain in effect.
2) Warranty applies only to the original location of installa­ tion and may not be transferred.
3) Warranty is in lieu of all other warranties expressed or implied and all other obligations or liabilities related to the sale or use of its grill products.
4) Warranty shall not apply and Lynx is not responsible for damage resulting from misuse, abuse, alteration of or tampering with the appliance, accident, hostile environ-
7) The cost of a service call to diagnose trouble.
SIDE BURNER ACCESSORY CARE & USE/INSTALLATION
25
|
Page 26
siDe Burner eXploDeD parts VieW
MODEL INNER BURNER OUTER BURNER OPEN TOP BURNER TOTAL INPUT
LPB 13,000 34,000 47,000 BTU/Hr LSB2PC 2 @ 15,000 30,000 BTU/Hr LCB1 1 @ 15,000 15,000 BTU/Hr LCB2 2 @ 15,000 30,000 BTU/Hr
26
SIDE BURNER ACCESSORY CARE & USE/INSTALLATION
|
MODEL-SPECIFIC BTU OUTPUTS
Page 27
inDeX
A
Adjusting:
Low Heat Adjustment .................................................... 12
Power Burner Air Shutter ............................................... 10
Air Shutter Adjustment .................................................. 10
C
Code Requirements ....................................................... 14
Cold Weather Use ..........................................................18
Connections:
Electrical ........................................................................ 19
Gas ............................................................................ 16
Optional Electrical Kits .................................................. 19
Contacting LYNX ........................................................... 13
D
Damage:
Shipment ....................................................................... 14
E
Electrical Connections ................................................... 19
Exploded Parts View ...................................................... 26
G
Gas Connections ........................................................... 16
Gas Leaks, Testing for .................................................... 20
Gas Pressure Specs ....................................................... 16
Gas Requirements ......................................................... 16
Gas Supply Line Runs .................................................... 18
Grilling in Windy Conditions ........................................... 7
O
Obtaining Service .......................................................... 13
Optional Electrical Kits .................................................. 19
P
Propane Hook Up .......................................................... 18
Purging the Gas Lines ................................................... 11
S
Schematics ..................................................................... 21
Serial Number, Location ................................................ 13
Service, Contacting Lynx ............................................... 13
Specications:
Code Requirements ....................................................... 14
Gas Pressure .................................................................. 16
Natural Gas Hook Up .................................................... 18
Propane Hook Up .......................................................... 18
Supply Line Runs ........................................................... 18
T
Technical Support .......................................................... 13
Testing:
Leak Testing ................................................................... 20
The Installation .............................................................. 20
W
Warranty:
Limited ........................................................................... 24
Common Area Limited .................................................. 25
L
Leak testing ................................................................... 20
Lighting the Burner........................................................ 11
Lighting with a Match .................................................... 11
Locating:
Serial Number ............................................................... 13
LP Connections ............................................................. 17
M
Manual Lighting ............................................................. 11
Maximum Supply Line Runs .......................................... 18
N
Natural Gas Hook Up .................................................... 18
SIDE BURNER ACCESSORY CARE & USE/INSTALLATION
27
|
Page 28
Lynx Professional Grills
5895 Rickenbacker Rd.
Commerce, CA 90040
Service: (888) Buy-Lynx (888-289-5969)
Fax: (323) 838-1778
www.lynxgrills.com