TX500b SERIES
SMART TEMP
Complete, Easy To Read Programming And Installation Instructions
IMPORTANT!
READ THE
INSTALLATION
INSTRUCTIONS
FIRST.
FEATURES
• The TX500 can be used with most 24
volt gas, oil or electric heating and air
conditioning systems or gas millivolt
heating systems. It cannot be used
with 120 volt heating systems or heat
pumps. Ask your dealer for other LUX
thermostats to control those systems.
• The TX500 is programmable. There
are four programming periods per day.
Each period can be programmed
separately.
• You can use the built-in time/
temperature programs, or alter
them to suit your schedule. The
TX500 provides separate programming
for weekdays and weekends — for both
heating and cooling. You can override the
programmed temperatures for as little as one
programming period or for an entire vacation.
• In cool weather,when the system switch is set to HEAT, the TX500 will maintain cooler “set back”
room temperatures to save energy. It will then change to warmer “comfort” settings - all automatically, at
specified times during the day.
• In warm weather,when the system switch is set to COOL, the TX500 will maintain warmer “set back” room
temperatures to save energy. It will then change to cooler “comfort” settings - all automatically, at specified
times during the day.
• A large liquid crystal display shows time, day of the week, and room and set temperatures.
5/2 Minute Selectable Minimum Run/Off Time for Short Cycle/Compressor Protection
•
• Two Energizer
temperature programs.
®
or DURACELL® “AA” alkaline batteries (not included) are used to retain your time and
®
ELECTRONIC THERMOSTAT
O
M
UP
O
M
N
R
O
M
H
E
Y
A
D
A
T
VE
E
T
H
IG
N
M
P
DOWN
SET
SET
SUNDAY
WEEKDAY
RESET
FAN
PROGRAM
PROGRAM
HEAT
AUTO
OFF
HOLD
ON
COOL
SET
RUN
NEXT
DAY/TIME
500
Patents Pending
SIMPLIFIED INSTRUCTIONS
TEMPORARY TEMPERATURE
TO SET PROGRAMS
TO SET TIME & DAY
OVERRIDE
•Rotate Dial to SET
•Rotate Dial to set DAY/TIME.
UP
N
R
O
M
H
E
Y
A
D
A
T
VE
E
T
H
IG
N
M
P
DOWN
SET
SET
SUNDAY
WEEKDAY
RESET
FAN
PROGRAM
PROGRAM
HEAT
AUTO
OFF
HOLD
ON
COOL
SET
RUN
NEXT
DAY/TIME
500
Patents Pending
SIMPLIFIED INSTRUCTIONS
TEMPORARY TEMPERATURE
TO SET PROGRAMS
TO SET TIME & DAY
OVERRIDE
•Rotate Dial to SET
•Rotate Dial to set DAY/TIME.
Thank you for your confidence in our product. To obtain the best
results from your investment, please read this manual and acquaint
yourself with your purchase before installing your new thermostat.
Then follow the installation procedures, one step at a time. This
will save you time and minimize the chance of damaging the
thermostat and the systems it controls. These instructions may
contain information beyond that required for your particular instal-
lation. Please save for future reference.
LUX
Speed Dial
The Active
Program Period
MO
ORN
M
Y
DA
E
EV
HT
G
NI
SET
WEEKDAY
PROGRAM
SET
DAY/TIME
500
Patents Pending
TO SET TIME & DAY
•Rotate Dial to set DAY/TIME.
•Press UP to change
current day.
•Press NEXT.
•Press UP/DOWN to set time.
Rotate the
dial to
the RUN
position
to close
the door.
Thermostat Cover
The Set Temperature
®
Crystal
Display
H
E
A
T
M
P
SET
SUNDAY
RESET
PROGRAM
HOLD
RUN
NEXT
SIMPLIFIED INSTRUCTIONS
TO SET PROGRAMS
•Rotate Dial to SET
WEEKDAY,
SATURDAY or
SUNDAY PROGRAM.
•Press UP/DOWN to
adjust start time.
•Press NEXT.
•Press UP/DOWN to
adjust temperature.
•Press NEXT.
•Repeat as needed or
rotate dial to RUN to
stop Programming.
Liquid
UP
DOWN
FAN
AUTO
ON
TEMPORARY TEMPERATURE
OVERRIDE
•Press UP/DOWN to
adjust set temperature.
•To clear OVERRIDE press
UP/DOWN until original set
temperature appears or wait
for the start tf the next period.
TEMPERATURE HOLD
•Press HOLD. Adjust temperature
as desired with UP/DOWN.
•To clear, press HOLD again.
Fan Switch
System Switch
HEAT
OFF
COOL
Thermostat
Body/Sub-base
.
CAUTION
• Your thermostat is a precision instrument. Please handle it with care.
• Turn off electricity to the appliance before installing or servicing thermostat or any part of the system.
Do not turn electricity back on until work is completed.
• Do not short (jumper) across electric terminals at control on furnace or air conditioner to test the
system. This will damage the thermostat and void your warranty.
• All wiring must conform to local codes and ordinances.
• This thermostat is designed for use with 24 volt and millivolt systems. The thermostat should be
limited to a maximum of 1.0 amps; higher amperage may cause damage to the thermostat. If you are
in doubt, call your utility company.
© COPYRIGHT 2006 LUX PRODUCTS CORPORATION. ALL RIGHTS RESERVED
DAY
EVE
NIGHT
L
O
B
A
T
T
ATTACHING WIRES
4. Hold the base against the wall, with the wires coming through
wherever it is convenient for wiring. Route the wires to below the
terminal block. Position the base for best appearance (to hide
any marks from an old thermostat). Attach the base to the wall
with the two screws provided.
CAUTION
Do not allow wires to touch each other or parts on thermostat. Wires must be
trapped between black spacer and brass terminal. Also, be sure to tighten
securely all 5 electrical terminal screws.
WIRING DIAGRAMS
TYPICAL COOLING AND
HEATING SYSTEM
(4-WIRE)
GYWRHRC
GAS
FAN
VALVE
COOL
COMP
24 VAC HEAT
TRANSFORMER
110
Figure 10
TYPICAL COOLING AND
HEATING SYSTEM
(5-WIRE)
GYWRHRC
GAS
FAN
VALVE
REMOVE
COOL
COMP
JUMPER
BETWEEN
RH & RC
24 VAC HEAT
TRANSFORMER
110
24 VAC COOL
TRANSFORMER
Figure 11
110
INSTALLING BATTERIES/ MAINTENANCE
The TX500 requires two new Energizer®or DURACELL®"AA" size
alkaline batteries to operate your furnace and retain its programming in
memory. Replace the batteries when the LO BATT indicator appears in the
display or at least once a year.
NOTE
If you have an electric system and the blower does not operate after installation, find the
electric/gas heat selector on the back of the body . Move the selector to the ELEC position.
These diagrams are provided for new installations or unreferenced wires.
1. Remove fresh batteries from their carton.
2. Remove body of thermostat as described
at bottom of first column.
3. Remove the used batteries.
4. Install two new Energizer
size alkaline batteries in the battery compartment.
®
or DURACELL®"AA"
REPLACE BATTERIES
WHEN INDICATOR
APPEARS
Heat Selector
Observe the polarity marking shown in the compartment.
Place body back on wall.
5. Place the body back on the wall. Hook the top of the
body onto the base, swing the body down and snap the
body onto the base.
WARNING: Use Energizer®or DURACELL
®
Alkaline Batteries Only.
Battery Compartment
Installation is now complete. Be sure to turn the
power back on to your heating and/or air
conditioning system. If this is the first time you are
installing batteries, the thermostat will display “SUN
12:00 AM” Within 90 seconds the thermostat will begin
to display the room temperature alternately with the
time. To correct the display, see “Setting the TIME and
DAY,” after you set the programs.
NOTE
When replacing batteries, you
have approximately 1 minute
before programs are lost.
TECHNICAL ASSISTANCE
If you have any problems installing or using this thermostat, please carefully and
thoroughly review the instruction manual. If you require assistance, please contact
our Technical Assistance Department at 856-234-8803 during regular business hours
between 8:00AM and 4:30PM Eastern Standard Time, Monday through Friday. You
can also receive technical assistance online anytime day or night at
http://www.luxproducts.com. Our web site offers you answers to the most common
technical questions, and also permits you to email your questions to our technical
support staff at your convenience.
TYPICAL HOOKUP FOR 2-WIRE
24V HEATING SYSTEM AND
MILLIVOLT SYSTEM
GYWRHRC
GAS
VALVE
24 VAC
TRANSFORMER
OR
THERMOPILE
110
Figure 8
TYPICAL HOOKUP FOR 3-WIRE
HEAT SYSTEM IF THIRD
WIRE IS FAN WIRE
GYWRHRC
GAS
VALVE
FAN
24 VAC
TRANSFORMER
110
Figure 9
WARRANTY
Limited Warranty: If this unit fails because of defects in materials or workmanship
within three years of date of original purchase, LUX Products Corporation will, at its
option, repair or replace it. This warranty does not cover damage by accident, misuse,
or failure to follow installation instructions. Implied warranties are limited in duration to
three years from date of original purchase. Some states do not allow limitations on
how long an implied warranty lasts, so the above limitation may not apply to you.
Please return malfunctioning or defective units to the participating retailer from which
purchase was made, along with proof of purchase. Please refer to "TECHNICAL
ASSISTANCE" before returning thermostat. Purchaser assumes all risks and liability for
incidental and consequential damage resulting from installation and use of this unit.
Some states do not allow the exclusion of incidental or consequential damages, so
the above exclusion may not apply to you. This warranty gives you specific legal rights
and you may also have other rights which vary from state to state. Applicable in the
U.S.A. only.