Complete, Easy To Read
INSTALLATION AND
OPERATING INSTRUCTIONS
PSP300 SERIES
FEATURES
5
SMART TEMP®ELECTRONIC THERMOSTAT
LUX PRODUCTS CORPORATION
Mt. Laurel, New Jersey 08054, USA
43383-05
IMPORTANT!
Please read all instructions carefully before
beginning installation.
Save them for future reference.
W A R N I N G :
FOR USE ONLY WITH AIR CONDITIONERS AND
SPACE HEATERS THAT AUTOMATICALLY
RESTART COOLING OR HEATING OPERATION
AFTER POWER RECONNECTION
Thank you for your confidence in our product.
To obtain the best results from your investment,
please read these instructions and acquaint
yourself with your purchase before installing your
new thermostat. Then follow the installation procedures, one step at a time. This will save you
time and minimize the chance of damaging the
thermostat and the systems it controls. These
instructions may contain information beyond that
required for your particular installation. Please
save for future reference.
COMPATIBILITY
Your PSP300 Programmable Outlet Thermostat
is compatible with 120Volt, 15 Amp Plug, 60 Hz
Window Air Conditioning Units and Portable
Space Heaters only. It cannot be used with typical 24 V systems, hydronics systems, or heat
pumps. Ask your dealer for other LUXPRO
thermostats to control those systems.
®
1. ON/OFF SWITCH
2. SOFT TOUCH BUTTONS
3. LUX SPEED DIAL
●
Heating and Cooling
●
Electronic
●
Programmable
●
Plugs into normal 110 Volt 15
Amp Electrical Outlet
●
5/2 Day Programming
(Weekdays and Weekends can
be different)
●
Energy Star®Compliant
●
Default Energy Star
Approved Program
●
Positive On/Off Switch
●
Easy to Install
●
4 Periods Per Day
●
120VAC Powered with
Batteries
●
2 G13A size 1.5V Alkaline
Button Cell Batteries Included
(For Clock Only)
●
Temporary and Constant
Temperature Override
ELECTRICAL RATINGS
●
120V/60 Hz
●
Maximum load is 15 Amps at 120 Volts
●
Power Consumption 2 W (maximum)
●
Plug and Receptacle NEMA 5-15R (normal household 15 Amp
receptacle)
2
1
3
4
4. HEAT/COOL SWITCH
®
®
5. EXTERNAL TEMPERATURE
SENSOR
●
Separate Programs for
Heating and Cooling
●
Armchair Programming
●
Easy Programming with LUX
Speed Dial
●
Battery Free Nonvolatile
Memory For All Programs And
Settings
●
ETL Approved
●
User Calibration
●
On Screen Low Battery
Indicator
●
F/C Temperature Display
●
Soft Touch Buttons
●
2 Minute Short Cycle
Protection
●
Adjustable Temperature differential/Cycle Rate (#1 thru #9)
●
1 Year Warranty
®
(Patent # 5,673,850)
WARNINGS:
BACK OF UNIT
SCREWDRIVER
EXTERNAL
TEMPERATURE
SENSOR
BATTERY PANEL
RIBBON
●
Read all instructions before using this ther-
INSTALLATION
mostat.
●
To reduce the risk of electric shock, this
product has a grounding type plug that has a
third (grounding) pin. This pin will only fit into a
grounding type power outlet. If the plug does
not fit into the outlet, contact a qualified electrician to install the proper outlet. Do not change
the plug in any way.
●
Do not use Outdoors.
●
Do not use in a bathroom. Never locate
where it may fall into a bathtub or other water
container.
●
Do not insert or allow foreign objects to enter
any openings as this may cause electric shock,
fire, or damage to the thermostat.
●
Do not use in areas where gasoline, paint,
flammable liquids are used or stored.
●
Space Heaters can be dangerous if used
TOOLS REQUIRED:
LOCATION:
●
Do not locate where air circulation is poor,
such as in a corner or an alcove; or behind an
open door.
●
Do not install it where there are unusual heating conditions, such as: in direct sunlight; near a
lamp, television, radiator, register, or fireplace;
near hot water pipes in a wall; near a stove on
the other side of the wall.
●
Do not locate in unusual cooling conditions,
such as: on a wall separating an unheated
room; or in a draft from a stairwell, door, or window .
●
Do not locate in a damp area. This can lead
to corrosion that will shorten thermostat life.
●
Do not install the unit until all construction
work and painting has been completed.
improperly. Be sure to follow all the Warnings
and Cautions that came with the instruction
manual written by the manufacturer of the
Space Heater.
●
Avoid the use of an extension cord because
the extension cord may overheat and cause
risk of fire. However, if you have to use an
extension cord, the cord should be a 3-wire,
grounding type, with No. 14 AWG minimum
size and rated not less than 1875 Watts.
●
Use this thermostat only as described in this
manual. Any other use not recommended by
the manufacturer may cause fire, electric
shock, or injury to persons.
●
Never clean this thermostat while it is
PREPARING THE UNIT
1. The PSP300 comes with (2) G13A size 1.5V
Alkaline Button Cell Batteries already installed.
These batteries power the clock only during normal operation. They also provide backup power
to retain the thermostats programs and settings
while it is not plugged into the wall. In order to
"activate" them, you must remove the black ribbon from between the two batteries prior to
using it. Use a small regular screwdriver to pry
open the battery holder and pull out the black
ribbon.
plugged in. Turn On/Off switch to Off, pull out
of the wall, and then clean by using a rag only.
Small regular screwdriver
CAUTIONS:
●
Your thermostat is protected against normal
static electric discharges. To minimize the risk
of damaging the unit in extremely dry weather,
touch a grounded metal object before touching
your thermostat.
●
Be careful not to drop the unit or disturb