INSTALLATION AND OPERATING
INSTRUCTIONS
3. Do not locate in unusual cooling conditions, such as
on an outside wall, or one separating an unheated
room, or in drafts from stairwells, doors, or windows.
4. Do not locate in a damp or humid area. This can
shorten thermostat life due to corrosion.
5. Do not locate where air circulation is poor, such as in
a corner, alcove, or behind an open door.
6. Do not install until all construction work and painting
have been completed.
LUX PRODUCTS CORPORATION
Mt. Laurel, New Jersey 08054, USA
www.luxproproducts.com
LUXPRO
PSM40SA
HEATING & COOLING THERMOSTAT
ATTENTION : not for use with
compressors without
time delays.
52047
2) TOOLS REQUIRED
Wirestripper or knife, drill with 3⁄16" bit, screwdriver,
level and a pencil.
3) REMOVING OLD THERMOSTAT
Please read all instructions carefully. As you complete
each step, check the adjoining square ■■✓.
■■ Disconnect electricity and turn off gas to the heater.
■■ Remove cover from old thermostat.
■■ Disconnect wires from thermostat, making sure they
SPECIFICATIONS
ELECTRICAL RATING ......24 Vac (30 Vac Maximum)
SWITCH ACTION......................Open contact switch
ANTICIPATOR RATING
(HEATING)....................................0.15A to 1.2A
(COOLING)...................................Fixed 24 VAC
TEMPERATURE RANGE .......................50°F to 90°F
■■ Strip insulation 3⁄8" from wire ends and clean off any
■■ Loosen all screws on the old thermostat and remove
■■ Fill wall opening with non-combustible insulation to
4) INSTALLING NEW THERMOSTAT
■■ Place new decorative wall plate (if supplied), Figure 4,
INSTALLATION & OPERATION
■■ Remove Front Cover of new thermostat by inserting a
1). THERMOSTAT LOCATION
For accurate temperature control and comfort, correct
location is very important. On new installations, the
guidelines listed below should be followed as closely as
possible. When replacing an old thermostat, install the
new one in the same location unless these conditions
suggest otherwise.
1. Locate the thermostat on an inside wall about five
feet above the floor, where it is easy to install and
adjust. It should be in a room that is used often, such
as a family room.
2. Do not install it where there are unusual heating
conditions, such as direct sunlight, close to a lamp,
radio, television, radiator, register, near a fireplace, or
other heat producing appliance. Also, check for hot
water pipes within the wall, or a stove on the other
side of the wall.
■■ Place Sub-Base, Figure 3, on wallplate over wall
■■ Drill two holes with 3/16” bit, 1” deep.
■■ Insert plastic screw anchors into drilled holes, flush
■■ Bring wires through large hole in decorative wall plate
■■ Referring to your notes and the following diagrams,
do not fall back inside the wall. Make note of wires
and to which terminals they are attached as you
disconnect them. For example: “Yellow wire to
terminal Y, Red wire to terminal RH,” etc.
corrosion.
it from the wall.
prevent drafts from affecting thermostat.
over wall opening. Decorative wall plate can
optionally be left off.
finger in the side of the thermostat and gently prying
away each corner. Remove Base, Figure 2, from SubBase, Figure 3, by loosening three captive screws.
opening. Mark wall with pencil at mounting holes as
shown in Figure 2. Now lay wallplate and Sub-Base to
the side.
with wall surface.
and through Hole For Wires in Sub-Base.
attach wires to terminal screws shown in Figure 2.
Make sure bare metal wires do not touch each other.
Push all excess wire back into wall.
© 2007 LUX PRODUCTS CORPORATION. ALL RIGHTS RESERVED
1
WIRING DIAGRAMS
Heating Systems
FAN RELAY
COOLING COMPRESSOR
HEATING CONTROL
HEATING TRANSFORMER
DAMPER OR CHANGEOVER VALVE
(POWERED IN HEAT)
DAMPER OR CHANGEOVER VALVE
COOL TRANSFORMER
(POWERED IN COOL)
GYWRHBORC
Tape Off
Tape Off **
G
TC
4
F
H
W
C
Tape Off *
5
V
R*
RC
R
B
H
* If replacing a Honeywell TM-11,
tape off wire “R”; connect wire “B”
to terminal “RH.”
** If replacing a Honeywell thermostat
with a clock wire “C,” tape off wire “C”
Cooling Systems
FAN RELAY
COOLING COMPRESSOR
HEATING CONTROL
HEATING TRANSFORMER
DAMPER OR CHANGEOVER VALVE
(POWERED IN HEAT)
DAMPER OR CHANGEOVER VALVE
COOL TRANSFORMER
(POWERED IN COOL)
GYWRHBORC
Tape Off
*
C
G
Y
F
C
T
V
R
RC
* If both Y and C wire are
present, tape off “C” wire.
Heating/Cooling Systems
FAN RELAY
COOLING COMPRESSOR
HEATING CONTROL
HEATING TRANSFORMER
DAMPER OR CHANGEOVER VALVE
(POWERED IN HEAT)
DAMPER OR CHANGEOVER VALVE
COOL TRANSFORMER
GYWRHBORC
Tape Off
F
G
C
T
4- or 5-Wire with One Transformer
(POWERED IN COOL)
*
Y
C
W
B
V
R
RC
O
(Optional)
* If both Y and C wire are
present, tape off “C” wire.
(Optional)
Heating/Cooling Systems
FAN RELAY
COOLING COMPRESSOR
HEATING CONTROL
HEATING TRANSFORMER
DAMPER OR CHANGEOVER VALVE
(POWERED IN HEAT)
DAMPER OR CHANGEOVER VALVE
COOL TRANSFORMER
GYWRHBORC
Tape Off
TC
5- or 6-Wire with Two Transformers
(POWERED IN COOL)
V
*
F
C
G
Y
W
B
4
A
RH
O
R
* If both Y and C wire are
present, tape off “C” wire.
C
R
(Optional)
(Optional)
2