3. Do not locate in unusual cooling conditions, such as on an outside wall, or one separating an unheated room, or in drafts from stairwells, doors, or windows.
4. Do not locate in a damp or humid area. This can shorten thermostat life due to corrosion.
5. Do not locate where air circulation is poor, such as in a corner, alcove, or behind an open door.
6. Do not install until all construction work and painting have been completed.
LUX PRODUCTS CORPORATION
Mt. Laurel, New Jersey 08054, USA www.luxproproducts.com
LUXPRO
PSM40SA
HEATING & COOLING THERMOSTAT
ATTENTION : not for use with
compressors without
time delays.
52047
2) TOOLS REQUIRED
Wirestripper or knife, drill with 3⁄16" bit, screwdriver, level and a pencil.
3) REMOVING OLD THERMOSTAT
Please read all instructions carefully. As you complete each step, check the adjoining square ✓.
Disconnect electricity and turn off gas to the heater.
Remove cover from old thermostat.
Disconnect wires from thermostat, making sure they
SPECIFICATIONS
ELECTRICAL RATING ......24 Vac (30 Vac Maximum)
SWITCH ACTION......................Open contact switch
ANTICIPATOR RATING
(HEATING)....................................0.15A to 1.2A
(COOLING)...................................Fixed 24 VAC
Strip insulation 3⁄8" from wire ends and clean off any
Loosen all screws on the old thermostat and remove
Fill wall opening with non-combustible insulation to
4) INSTALLING NEW THERMOSTAT
Place new decorative wall plate (if supplied), Figure 4,
INSTALLATION & OPERATION
Remove Front Cover of new thermostat by inserting a
1). THERMOSTAT LOCATION
For accurate temperature control and comfort, correct location is very important. On new installations, the guidelines listed below should be followed as closely as possible. When replacing an old thermostat, install the new one in the same location unless these conditions suggest otherwise.
1. Locate the thermostat on an inside wall about five feet above the floor, where it is easy to install and adjust. It should be in a room that is used often, such as a family room.
2. Do not install it where there are unusual heating conditions, such as direct sunlight, close to a lamp, radio, television, radiator, register, near a fireplace, or other heat producing appliance. Also, check for hot water pipes within the wall, or a stove on the other side of the wall.
Place Sub-Base, Figure 3, on wallplate over wall
Drill two holes with 3/16” bit, 1” deep.
Insert plastic screw anchors into drilled holes, flush
Bring wires through large hole in decorative wall plate
Referring to your notes and the following diagrams,
do not fall back inside the wall. Make note of wires and to which terminals they are attached as you disconnect them. For example: “Yellow wire to terminal Y, Red wire to terminal RH,” etc.
corrosion.
it from the wall.
prevent drafts from affecting thermostat.
over wall opening. Decorative wall plate can optionally be left off.
finger in the side of the thermostat and gently prying away each corner. Remove Base, Figure 2, from Sub­Base, Figure 3, by loosening three captive screws.
opening. Mark wall with pencil at mounting holes as shown in Figure 2. Now lay wallplate and Sub-Base to the side.
with wall surface.
and through Hole For Wires in Sub-Base.
attach wires to terminal screws shown in Figure 2. Make sure bare metal wires do not touch each other. Push all excess wire back into wall.
© 2007 LUX PRODUCTS CORPORATION. ALL RIGHTS RESERVED
1
WIRING DIAGRAMS
Heating Systems
FAN RELAY
COOLING COMPRESSOR
HEATING CONTROL
HEATING TRANSFORMER
DAMPER OR CHANGEOVER VALVE
(POWERED IN HEAT)
DAMPER OR CHANGEOVER VALVE
COOL TRANSFORMER
(POWERED IN COOL)
GYWRHBORC
Tape Off
Tape Off **
G
TC
4
F
H
W
C
Tape Off *
5
V
R*
RC
R
B
H
* If replacing a Honeywell TM-11, tape off wire “R”; connect wire “B” to terminal “RH.” ** If replacing a Honeywell thermostat with a clock wire “C,” tape off wire “C”
Cooling Systems
FAN RELAY
COOLING COMPRESSOR
HEATING CONTROL
HEATING TRANSFORMER
DAMPER OR CHANGEOVER VALVE
(POWERED IN HEAT)
DAMPER OR CHANGEOVER VALVE
COOL TRANSFORMER
(POWERED IN COOL)
GYWRHBORC
Tape Off
*
C
G
Y
F
C
T
V
R
RC
* If both Y and C wire are
present, tape off “C” wire.
Heating/Cooling Systems
FAN RELAY
COOLING COMPRESSOR
HEATING CONTROL
HEATING TRANSFORMER
DAMPER OR CHANGEOVER VALVE
(POWERED IN HEAT)
DAMPER OR CHANGEOVER VALVE
COOL TRANSFORMER
GYWRHBORC
Tape Off
F
G
C
T
4- or 5-Wire with One Transformer
(POWERED IN COOL)
*
Y
C
W
B
V
R
RC
O
(Optional)
* If both Y and C wire are
present, tape off “C” wire.
(Optional)
Heating/Cooling Systems
FAN RELAY
COOLING COMPRESSOR
HEATING CONTROL
HEATING TRANSFORMER
DAMPER OR CHANGEOVER VALVE
(POWERED IN HEAT)
DAMPER OR CHANGEOVER VALVE
COOL TRANSFORMER
GYWRHBORC
Tape Off
TC
5- or 6-Wire with Two Transformers
(POWERED IN COOL)
V
*
F
C
G
Y
W
B
4
A
RH
O
R
* If both Y and C wire are
present, tape off “C” wire.
C
R
(Optional)
(Optional)
2