1). THERMOSTAT LOCATION
For accurate temperature control and comfort, correct location is very
important. On new installations, the guidelines listed below should be
followed as closely as possible. When replacing an old thermostat,
install the new one in the same location unless these conditions
suggest otherwise.
1. Locate the thermostat on an inside wall about five feet above the floor,
where it is easy to install and adjust. It should be in a room that is used
often, such as a family room.
2. Do not install it where there are unusual heating conditions, such as
direct sunlight, close to a lamp, radio, television, radiator, register, near
a fireplace, or other heat producing appliance. Also, check for hot
water pipes within the wall, or a stove on the other side of the wall.
3. Do not locate in unusual cooling conditions, such as on an outside wall, or
one separating an unheated room, or in drafts from stairwells, doors, or
windows.
4. Do not locate in a damp or humid area. This can shorten thermostat life
due to corrosion.
5. Do not locate where air circulation is poor, such as in a corner, alcove,
or behind an open door.
6. Do not install until all construction work and painting have been
completed.
2) TOOLS REQUIRED
Wirestripper or knife, drill with 3⁄16" bit, screwdriver, level and a pencil.
3) REMOVING OLD THERMOSTAT
Please read all instructions carefully. As you complete each step, check
the adjoining square ■■✓.
LUX
15
10
60
50
SPECIFICATIONS
ELECTRICAL RATING
24 Vac (30 Vac Maximum)
SWITCH ACTION
Open Contact Switch
ANTICIPATOR RATING
0.15A to 1.2A
TEMPERATURE RANGE
50°F to 90°F
■■ Disconnect electricity and turn off gas to the heater.
20
25
30
70
80
90
■■ Remove cover from old thermostat.
■■ Loosen all screws.
■■ Disconnect wires from thermostat, making sure they do not fall back inside
the wall.
■■ Strip insulation
■■ Fill wall opening with non-combustible insulation to prevent drafts from
affecting thermostat.
3
⁄8" from wire ends and clean off any corrosion.
4) INSTALLING NEW THERMOSTAT
■■ Place new decorative wall plate (if supplied), Figure 3, over wall
opening. Decorative wall plate can optionally be left off.
■■ Remove Front Cover of new thermostat by inserting a finger in the side
of the thermostat and gently prying away each corner. Place Base,
Figure 2, on wall plate over wall opening. Mark wall with pencil at
mounting holes as shown in Figure 2. Now lay wall plate and base to
the side.
■■ Drill two holes with
■■ Insert plastic screw anchors into drilled holes, flush with wall surface.
■■ Bring wires through large hole in decorative wall plate and through
Hole For Wires in Base.
■■ Fasten Base loosely to wall using two mounting screws. Place a level
against the bottom of the Base, adjust until it is level and then tighten
mounting screws to secure the Base.
LUX PRODUCTS CORPORATION Philadelphia, PA 19112
3
⁄16" bit, 1" deep.
© COPYRIGHT 2006 LUX PRODUCTS CORPORATION. ALL RIGHTS RESERVED
■■ Attach wires to terminal screws shown in Figure 2. (Either wire to
either terminal) Push excess wire back into wall opening.
■■ Find anticipator setting on old thermostat. Setting on new
thermostat should be the same. Do this by carefully sliding the
long pointer on the anticipator over the desired number. If old
anticipator setting cannot be determined, look on gas control on
furnace, or set it at .6. During heating season, furnace should
operate about five times an hour. If adjustments are necessary,
move heat anticipator pointer slightly and recheck. NOTE: Set
pointer to 1.2 for millivolt systems.
■■ Attach front cover, Figure 1, to base.
■■ Tur n electricity and gas back on and set pointer on top of
thermostat to desired temperature.
A thermostat can only control temperature near it. If
you find that it is uncomfortable some distance away
from the thermostat, change the setting in order to
compensate for this.
FIGURE 3
DECORATIVE WALL PLATE
FIGURE 1 FRONT COVER
FIGURE 2 BASE
MOUNTING HOLE
UP
.2
.15
R
.12
E
G
N
C
O
Y
L
.25
HOLES FOR WIRES
CAPTIVE
SCREW
C
L
E
S
.5
.3
.4
ANTICIP
LONG
POINTER
CAPTIVE
SCREW
MOUNTING
HOLE
ATOR
TECHNICAL ASSISTANCE
If you have any problems installing or using this thermostat,
please carefully and thoroughly review the instruction manual.
If you require assistance, please contact our Technical
Assistance Department at 856-234-8803 during regular
business hours between 8:00AM and 4:30PM Eastern
Standard Time, Monday through Friday. You can also receive
technical assistance online anytime day or night at
http://www.luxproducts.com. Our web site offers you answers
to the most common technical questions, and also permits you
to email your questions to our technical support staff at your
convenience.
WARRANTY
Limited Warranty: If this unit fails because of defects in
materials or workmanship within three years of date of original
purchase, LUX Products Corporation will, at its option, repair
or replace it. This warranty does not cover damage by
accident, misuse, or failure to follow installation instructions.
Implied warranties are limited in duration to three years from
date of original purchase. Some states do not allow limitations
on how long an implied warranty lasts, so the above limitation
may not apply to you. Please return malfunctioning or defective
units to the participating retailer from which purchase was
made, along with proof of purchase. Please refer to
"TECHNICAL ASSISTANCE" before returning thermostat.
Purchaser assumes all risks and liability for incidental and
consequential damage resulting from installation and use of
this unit. Some states do not allow the exclusion of incidental
or consequential damages, so the above exclusion may not
apply to you. This warranty gives you specific legal rights and
you may also have other rights which vary from state to state.
Applicable in the U.S.A. only.
RECYCLING
NOTICE
This product does not contain mercury. However, this
product may replace a unit which contains mercury and
should not be disposed of in the trash. Contact your local
waste management authority for proper disposal
instructions for mercury in a sealed glass tube. If you