Important Notes Please read before installing.
P/N 0301689
•Easy-to-follow
•Instrucciones Fáciles de Seguir
•InstruccionesFácilesdeSeguir •Easy-to-follow
P/N0301689
Multigang Installations
1.CAUTION: Use only with permanently-installed 120 V~ incandescent or halogen fixtures. To avoid overheating and possible damage to other equipment, do not use to control receptacles, fluorescent lighting fixtures, motor-driven appliances, or transformer-supplied appliances.
2.Install in accordance with all national and local electrical codes.
3.Only one dimmer can be used in a 3-way circuit.
4.When no “grounding means” exist within the wallbox then NEC® 2008, Article 404.9 allows a dimmer without a grounding connection to be installed as a replacement, as long as a plastic, noncombustible wallplate is used. For this type of installation, cap or remove the green ground wire on the dimmer and use an appropriate wallplate such as Lutron's Claro® or Fassada® series wallplates.
5.For new installations, install a test switch before installing the dimmer.
6.Protect dimmer from dust and dirt when painting or spackling.
7.Recommended minimum load is 40 W.
8.It is normal for the dimmer to feel warm to the touch during operation.
9.Clean dimmer with a soft damp cloth only. Do not use any chemical cleaners.
When installing more than one control in the same wallbox, |
|
Do Not Remove |
||
it may be necessary to remove all inner side sections prior |
|
Outside Sections |
||
to wiring (see diagram). If pre-installed, remove the Lutron |
|
|
||
wallplate and wallplate adapter from dimmer. Using pliers, |
|
|
||
bend side section up and down until they break off. Repeat |
|
|
||
for each side section to be removed. Removal of dimmer |
|
|
||
side sections reduces maximum load capacity. Refer to chart |
|
|
||
below for maximum dimmer capacity. |
Each Control Has Inside |
Middle Control Has Two Side |
||
Dimmer Capacity Chart |
||||
Sections Removed |
Sections Removed |
|||
Dimmer Rating |
No sides removed |
1 side removed |
2 sides removed |
|
600 W |
600 W |
500 W |
400 W |
|
1000 W |
1000 W |
800 W |
650 W |
? |
Technical Assistance |
|
you have questions concerning the installation or operation of this product, call the |
||
|
Lutron Technical Support Center. Please provide exact model number when calling. |
|
|
U.S.A. and Canada (24 hrs/7days) |
Fax +1.610.282.6311 |
|
+1.800.523.9466 |
|
|
México |
http://www.lutron.com |
|
+1.888.235.2910 |
Other countries 8am – 8pm ET +1.610.282.3800
Limited Warranty
Lutron will, at its option, repair or replace any unit that is defective in materials or manufacture within one year after purchase. For warranty service, return unit to place of purchase or mail to Lutron at 7200 Suter Rd., Coopersburg, PA 18036-1299, postage pre-paid.
This warranty is in lieu of all other express warranties, and the implied warranty of merchantability is limited to one year from purchase. This warranty does not cover the cost of installation, removal or reinstallation, or damage resulting from misuse, abuse, or damage from improper wiring or installation. This warranty does not cover incidental or consequential damages. LUTRON’S LIABILITY ON ANY CLAIM FOR DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE MANUFACTURE, SALE, INSTALLATION, DELIVERY, OR USE OF THE UNIT SHALL NEVER EXCEED THE PURCHASE PRICE OF THE UNIT.
This warranty gives you specific legal rights, and you may have other rights which vary from state to state. Some states do not allow the exclusion or limitation of incidental or consequential damages, or limitation on how long an implied warranty may last, so the above limitations may not apply to you.
NEC is a registered trademark of the National Fire Protection Association, Quincy, Massachusetts. Lutron, Claro, Fassada, and Glyder are registered trademarks of Lutron Electronics Co., Inc. © 2013 Lutron Electronics Co., Inc.
Lutron Electronics Co., Inc.
7200 Suter Road
Coopersburg, PA 18036-1299, U.S.A.
P/N 0301689 Rev. A
Lutron Technical Support Center |
1.800.523.9466 |
24 hrs / 7 days |
www.lutron.com |
||||
Installation |
|
|
|
5 |
Wiring the Dimmer. |
||
1 |
|
|
|
|
|||
Turning OFF Power. |
|
• For installations involving more than one control in a wallbox, |
|||||
|
|
refer to the section on Multigang Installations before beginning. |
|||||
|
• Turn power OFF at circuit breaker (or remove fuse). |
|
|
|
|||
|
ON ON |
OFF OFF |
Warning: Shock Hazard. May result in serious |
|
Dimmer wire location may vary by model number. |
||
|
injury or death. Turn off power at circuit |
|
NOTE: Reference wires by color, not backcover location. |
||||
|
|
OFF |
breaker before installing the unit. |
|
|
|
2 |
Removing Wallplate and Switch. |
|
• Remove wallplate and switch mounting screws. |
|
• Carefully remove switch from wall (do not remove wires). |
|
Caution: Verify |
|
power is OFF to |
|
switch before |
|
proceeding. |
3 Identifying the Type of Circuit.
Different-colored screw (Common). Actual location may vary.
OR
Ground (Bare
Copper or
Green Wire)
Ground (Bare Copper |
|
|
|
or Green Wire) |
|
|
Tag |
SINGLE-POLE: |
|
3-WAY: |
|
|
|
||
Insulated wires connected |
|
Insulated wires connected to three screws. One of |
|
to two screws of the |
OR |
these wires is connected to a screw of a different- |
|
same color. Replace with |
|
color (not green) or labeled COMMON. MARK or |
|
a SINGLE-POLE dimmer. |
|
TAG this wire to identify it when wiring. Replace |
|
See Step 5a. |
|
with a 3-WAY dimmer. See Step 5b. |
4 Disconnecting Switch Wires.
Important Note: Your wall switch may have two wires attached to the same screw (see illustrations below for examples). Tape these two wires together before disconnecting. If your switch has two wires attached to the same terminal, connect both wires to the Dimmer terminal in Step 5.
One wire in the |
One continuous |
backwired hole |
wire to the |
and one to the |
screw. |
screw. |
|
Screw Terminals: |
Push-in Terminals: |
Looped Wire: |
Turn screws to loosen. |
Insert screwdriver. Pull |
Turn screw to loosen. |
|
wire out. |
|
5a - Single-Pole Wiring
Black
Green or Bare |
Ground |
|
|
||
|
Black |
Black |
Green or Bare |
|
|
120 V |
|
|
60 Hz |
Ground |
Light |
|
|
•Connect the green or bare dimmer ground wire to the green or bare copper ground wire in the wallbox. (See Important Note 4.)
•Connect one of the black dimmer wires to either of the wires removed from the switch.
•Connect the remaining black dimmer wire to the other wire removed from the switch.
Note: To use a 3-Way dimmer (one black and two red wires) in a single-pole application, cap off one of the red wires and
follow instructions for single-pole wiring. (If the on/off switch works backwards, switch the red wires.)
5b - 3-Way Wiring |
|
• NOTE: Only one dimmer can be |
||||
|
|
Tag |
|
|||
|
Black |
|
|
used in a 3-WAY circuit. |
||
|
|
|
|
• Connect the green or bare |
||
|
|
|
|
|
dimmer ground wire to the green |
|
|
|
|
|
|
or bare copper ground wire in the |
|
|
|
|
|
|
wallbox. (See Important Note 4.) |
|
|
|
|
|
• Connect the black dimmer wire |
||
|
|
|
|
|
to the wire removed from the |
|
Green |
|
|
|
|
different-colored screw on the |
|
|
|
|
|
switch (marked or tagged wire). |
||
or Bare |
Red |
|
Ground |
• Connect one of the red dimmer |
||
|
|
|||||
|
|
|
|
|||
|
Black |
Red |
|
|
wires to either of the remaining |
|
Green or Bare |
Red |
|
|
wires removed from the switch. |
||
|
• |
Connect the remaining red |
||||
120 V |
Dimmer |
3-Way Switch |
||||
|
dimmer wire to the remaining wire |
|||||
60 Hz |
Ground |
|
Light |
|
removed from the switch. |
|
|
|
|
|
|
6 Mount Dimmer to Wallbox. traditional style |
||||
|
|
|
|
Note: To install a |
|
• Form wires carefully into the wallbox, |
wallplate, firmly pull |
||
|
mount and align dimmer. |
the Glyder® or Rotary |
||
|
knob to remove it. |
|||
|
• Install wallplate. |
|
|
|
|
|
|
Install the wallplate |
|
|
|
|
|
and re-attach the knob. |
|
Start screws. |
|
|
Glyder® |
|
|
|
Align dimmer and |
|
|
|
|
tighten screws. |
|
7 |
Turning ON Power. |
Rotary |
||
|
||||
|
• Turn power ON at circuit breaker |
|
||
|
(or replace fuse). |
ON |
OFF |
|
|
|
|
ON |
OFF |
ON |
OFF |