SD card real time Data Recorder
CO2, CO, O2, Humidity, Dew point, Temp. 6 in 1
AIR QUALITY METER
ANEMOMETER
Model : AQ-9901SD
Your purchase of this AIR QUALITY METER with SD CARD
DATA RECORDER marks a step forward for you into the field of
precision measurement. Although this METER is a complex and
delicate instrument, its durable structure developed. Please
read the following instructions carefully and always keep this
manual within easy reach.
OPERATION MANUAL
TABLE OF CONTENTS
1. FEATURES..................................................................1
2. SPECIFICATIONS........................................................
2
2-1 General Specifications............................................2
2-2 Electrical Specifications......................................... 5
3. FRONT PANEL DESCRIPTION.......................................8
4 MEASURING PROCEDURE............................................
10
5. OTHER FUNCTION......................................................11
5-1 Data Hold.............................................................
11
5-2 Record ( Max./ Min. reading ).................................11
5-3 LCD Backlight ON/OFF...........................................
12
6. DATALOGGER.............................................................13
6-1 Preparation before execute datalogger function....................13
6-2 Auto Datalogger ( Set sampling time 1 second )..............≧ 14
6-3 Manual Datalogger ( Set sampling time = 0 second )...........
15
6-4 Check time information.......................................................15
6-5 Check sampling time information.........................................16
6-6 SD Card Data structure.......................................................16
7. Saving data from the SD card to the computer..............18
8. ADVANCED SETTING...................................................20
9. POWER SUPPLY from DC ADAPTER..............................26
10. BATTERY REPLACEMENT...........................................26
11. SYSTEM RESET.........................................................27
12. RS232 PC SERIAL INTERFACE....................................27
13. PATENT....................................................................29
1. FEATURES
* Real time recorder, save the data into the SD memory
card and can be down load to the Excel, extra software
is no need. User can make the further data or graphic
analysis by themselves. under the Excel software.
* At the same time, the SD memory card can record 3
probe's data ( %RH/CO2/O2/Temp. or
%RH/CO2/CO/Temp. ) along with the time information
into the one Excel file at the same time.
* Manual datalogger is available, during execute the
manual datalogger function, it can set the different
location no. ( position 1 to position 99 ).
* Air quality measurement application, multi-function :
CO2 (Carbon dioxide ), CO ( Carbon monoxide ), O2
( Oxygen in air ), Humidity, temperature measurement.
* CO2 range : 0 to 4,000 ppm x 1 ppm.
* O2 range : 0 to 30.0 % x 0.1 %.
* CO range : 0 to 1,000 ppm x 1 ppm.
* Humidity range: 10 to 95 %RH.
* Dew point Temp. and Wet bulb Temp. measurement.
* Temp. range : 0 to 50.0 , / .℃℃℉
* CO2 sensor : NDIR, long term reliability.
* CO, O2 sensor : Galvanic cell type.
* Humidity sensor : Precision capacitance sensor
* Alarm setting with the beeper sound output.
* Sampling time for data recorder is 2 seconds to 8 hours.
* Complete set with 4 probes :
CO2/Temp. probe, O2/Temp. probe, CO/Temp. probe,
Humidity/Temp. probe, main meter and the hard carrying
case.
* Separate probe, easy for remote measurement.
* Meter can cooperate with 2 GB to 16 GB SD card, SD
card is optional.
* RS232/USB computer interface.
*Patented.
1
2. SPECIFICATIONS
2-1 General Specifications
Circuit Custom one-chip of microprocessor LSI
circuit.
Display LCD size : 52 mm x 38 mm
LCD with green backlight ( ON/OFF ).
Measurement CO2 (Carbon dioxide )
CO ( Carbon monoxide )
O2 ( Oxygen in air )
Humidity
Dew point Temp., Wet bulb Temp.
Temperature
Sensor CO2 NDIR * Nondispersive infrared sensor
structure Humidity Precision capacitance sensor
O2 Galvanic cell type
CO Galvanic cell type
Temp. Precision thermistor
Datalogger Auto 2 sec to 8 hour 59 min. 59 sec.
Sampling Time
@ Sampling time can set to 1 second,
Setting range
but memory data may loss.
Manual Push the data logger button
once will save data one time.
@ Set the sampling time to
0 second.
@ Manual mode, can also select the
1 to 99 position ( Location ) no.
Data error no. 0.1% of total saved data max.
Memory Card SD memory card. 1 GB to 16 GB.
Advanced * SD memory card Format
setting *Set clock time
* Set sampling time
@ main setting
* Auto power OFF management
* Set beep Sound ON/OFF
* Decimal point of SD card setting
* Temp. unit setting
* Alarm value setting
2
Data Hold Freeze the display reading.
Memory Recall Maximum & Minimum value.
Sampling Time Approx. 1 second.
of Display
Data Output RS 232/USB PC computer interface.
* Connect the optional RS232 cable
UPCB-02 will get the RS232 plug.
* Connect the optional USB cable
USB-01 will get the USB plug.
Power Supply
*
Alkaline or heavy duty DC 1.5 V battery
( UM3, AA ) x 6 PCs, or equivalent.
*
DC 9V adapter input. ( AC/DC power
adapter is optional ).
Power Current CO2 Normal operation ( w/o SD card save
measure- data and LCD Backlight is OFF) :
ment
Approx. DC 136.5 mA.
When SD card save the data and LCD
Backlight is OFF) :
Approx. DC 166 mA.
Humidity Normal operation ( w/o SD card save
measure- data and LCD Backlight is OFF) :
ment
Approx. DC 10.5 mA.
When SD card save the data and LCD
Backlight is OFF) :
Approx. DC 40 mA.
O2 or Normal operation ( w/o SD card save
CO data and LCD Backlight is OFF) :
measure-
Approx. DC 12.5 mA.
ment When SD card save the data and LCD
Backlight is OFF) :
Approx. DC 42.5 mA.
* AIf LCD backlight on, the power
consumption will increase approx.
12 mA.
3
Operating 0 to 50 . ( 32 to 122 ).℃℉
Temperature
Operating Less than 80% R.H.
Humidity
Weight 350 g/0.77 LB.
Dimension Meter 177 x 68 x 45 mm
Humidity 197 mm in length.
probe
CO2 probe 190 x 38 x 28 mm
O2 probe 150 x 38 x 38 mm
CO probe 150 x 38 x 38 mm
Accessories Instruction manual...........................1 PC
Included Hard carrying case, CA-08................
1 PC
CO2 probe.......................................1 PC
Humidity probe................................1 PC
O2 probe.........................................1 PC
CO probe.........................................1 PC
Optional SD memory card ( 2 GB )
Accessories AC to DC 9V adapter.
USB cable, USB-01.
RS232 cable, UPCB-02.
Data Acquisition software, SW-U801-WIN.
4
2-2 Electrical Specifications (23±5 )℃
CO2 ( Carbon dioxide )
Range 0 to 4,000 ppm
CO2 Resolution 1 ppm
( Carbon Accuracy ± 40 ppm
dioxide )
* 1,000 ppm.≦
± 5% of reading
23 ± 5 .℃
* > 1,000 ppm 3,000 ppm.≦
± 250 ppm typically
* > 3,000 ppm, reference only
Repeatability ± 20 ppm
* 3,000 ppm.≦
Temperature Range 0 to 50 ,32 to 122 .℃℃℉ ℉
Resolution 0.1 degree
Accuracy : ± 0.8 ℃℃ : ± 1.5 .℉℉
CO ( Carbon dioxide )
Range 0 to 1,000 ppm
CO Resolution 1 ppm
* Carbon
Accuracy ± ( 5% + 2 ppm )
monoxide
Response < 30 seconds
time *
Repeatability < 2%
Zero drift in < 5 ppm
long term
Sensitivity < 5% per year
drift
The response time value is specified to reach
the 90% reading value.
Temperature Range 0 to 50 ,32 to 122 .℃℃℉ ℉
Resolution 0.1 degree
Accuracy : ± 0.8 ℃℃ : ± 1.5 .℉℉
5
O2 ( Air oxygen )
Range 0 to 30 %O2.
O2 Resolution 0.1 %O2.
* Air oxygen
Accuracy ± ( 1 % reading + 0.2 % O2 ).
@ After calibration
Response time 15 secon
≦
@ t 90
Overload 100 %O2.
protection
Environment 0.9 to 1.1 atmosphere.
pressure range
Expected life 2 years.≧
time
Alarm If the measurement Air oxygen
value < 18.0 %O2, the buzzer
will sound for warning.
Temperature Range 0 to 50 ,32 to 122 .℃℃℉ ℉
Resolution 0.1 degree
Accuracy : ± 0.8 ℃℃ : ± 1.5 .℉℉
Humidity/Temperature
Range 5 % to 95 % R.H.
Humidity Resolution 0.1 % R.H.
Accuracy 70% RH :≧
± (3% reading + 1% RH).
< 70% RH :
± 3% RH.
Range 0 to 50 ,32 to 122 .℃℃℉ ℉
Temperature Resolution 0.1 degree
Accuracy ℃ ±0.8 .℃
℉ ±1.5 .℉
6
Dew Point Temp. ( Humidity )
℃ Range -25.3 to 48.9 ℃℃
Resolution 0.1 ℃
℉ Range -13.5 to 120.1 .℉℉
Resolution 0.1 .℉
Remark :
* Dew Point display value is calculated from the
Humidity/Temp. measurement automatically.
* The Dew Point accuracy is sum accuracy value of Humidity
& Temperature measurement..
Wet bulb Temp. ( Humidity )
℃ Range -21.6 to 50.0 ℃℃
Resolution 0.1 ℃
℉ Range -6.9 to 122.0 .℉℉
Resolution 0.1 .℉
Remark :
* Wet bulb display value is calculated from the Humidity/Temp.
measurement automatically.
* The Welt bulb accuracy is sum accuracy value of Humidity
& Temperature measurement..
@ Above specification tests under the environment RF Field Strength less than 3
V/M & frequency less than 30 MHz only.
7
3. FRONT PANEL DESCRIPTION