The lightning ash with arrowhead symbol, within an equilateral
triangle, is intended to alert the user to the presence of uninsulated
“dangerous voltage” within the product’s enclosure that may be
of sucient magnitude to constitute a risk of electric shock to
persons.
L’éclair avec une èche à l’intérieur d’un triangle équilatéral est
destiné à attirer l’attention de l’utilisateur sur la présence d’une
« tension dangereuse » non isolée à l’intérieur de l’appareil,
pouvant être susamment élevée pour constituer un risque
d’électrocution.
CAUTION
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS
APPARATUS TO RAIN OR MOISTURE.
AVERTISSEMENT
POUR RÉDUIRE LES RISQUES D’INCENDIE OU DE DÉCHARGE ÉLECTRIQUE,
N’EXPOSEZ PAS CET APPAREIL À LA PLUIE OU À L’HUMIDITÉ.
CAUTION
NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE
PERSONEL.
AVERTISSEMENT
AUCUNE PIÈCE CONTENUE A L’INTÉRIEUR NE PEUT ETRE RÉPARÉE PAR
L’UTILISATEUR, VEUILLEZ CONFIER TOUTE RÉPARATION À UN PERSONNEL
QUALIFIÉ.
The exclamation point within an equilateral triangle is intended
to alert the user to the presence of important operating and
maintenance (servicing) instructions in the literature accompanying
the appliance.
Le point d’exclamation à l’intérieur d’un triangle équilatéral
est destiné à attirer l’attention de l’utilisateur sur la présence
d’instructions importantes sur l’emploi ou la maintenance
(réparation) de l’appareil dans la documentation fournie.
IMPORTANT SAFETY INSTRUCTIONSPRÉCAUTIONS CONCERNANT LA SÉCURITÉ
■ Read these instructions.
■ Keep these instructions.
■ Heed all warnings.
■ Follow all instructions.
■ Do not use this apparatus near water.
■ Clean only with dry cloth.
■ Do not block any ventilation openings. Install in accordance with the
manufacturer’s instructions.
■ Do not install near any heat sources such as radiators, heat registers, stoves,
or other apparatus (including ampliers) that produce heat.
■ Protect the power cord from being walked on or pinched particularly
at plugs, convenience receptacles, and the point where they exit from the
apparatus.
■ Only use attachments/accessories specied by the manufacturer.
■ Unplug this apparatus during lightning storms or when unused for long
periods of time.
■ Refer all servicing to qualied service personnel. Servicing is required
when the apparatus has been damaged in any way, such as power-supply
cord or plug is damaged, liquid has been spilled or objects have fallen into
the apparatus, the apparatus has been exposed to rain or moisture, does not
operate normally, or has been dropped.
■ Lire ces instructions.
■ Conserver ces instructions.
■ Tenir compte de tous les avertissements.
■ Suivre toutes les instructions.
■ Ne pas utiliser ce produit à proximité d’eau.
■ Nettoyer uniquement avec un chion propre et sec.
■ Ne pas bloquer les orices de ventilation. Installer l’appareil conformément
aux instructions du fabricant.
■ Ne pas installer l’appareil à proximité d’une source de chaleur comme un
radiateur, une bouche de chaleur, un poêle ou tout autre appareil (y compris
un amplicateur) produisant de la chaleur.
■ Acheminer les cordons d’alimentation de sorte qu’ils ne soient pas piétinés
ni coincés, en faisant tout spécialement attention aux ches, prises de courant
et au point de sortie de l’appareil.
■ Utiliser exclusivement les xations et accessoires spéciés par le fabricant.
■ Débrancher l’appareil en cas d’orage ou lorsqu’il doit rester hors service
pendant une période prolongée.
■ Coner toute réparation à un personnel qualié. Faire réparer l’appareil s’il
a subi tout dommage, par exemple si la che ou le cordon d’alimentation est
endommagé, si du liquide a coulé ou des objets sont tombés à l’intérieur de
l’appareil, si l’appareil a été exposé à la pluie ou à de l’humidité, si l’appareil ne
fonctionne pas normalement ou est tombé.
Page 3
THIS APPARATUS MUST BE EARTHEDCET APPAREIL DOIT ÊTRE RELIÉ À LA TERRE
WARNING: Avoid electric shock and re hazard! Do not defeat
the safety purpose of the polarized or grounding-type plug. A
polarized plug has two blades with one wider than the other.
A grounding type plug has two blades and a third grounding
prong. The wide blade or the third prong are provided for
your safety. If the provided plug does not t into your outlet,
consult an electrician for replacement of the obsolete outlet.
THIS APPARATUS MUST BE EARTHED
SWEDEN: Apparaten skall anslutas till jordat uttag
NORWAY: Apparatet må tilkoples jordet stikkontakt
FINLAND: Laite on liitettävä suojamaadoituskoskettimilla varustettuun pistorasiaan
DENMARK: Apparatets stikprop skal tilsluttes en stikkontakt med jord, som giver forbindelse til stikproppens jord
AVERTISSEMENT: Evitez les décharges éléctriques et les risques
d’incendie.
Ne pas modier le système de sécurité de la che polarisée ou
de la che de terre. Une che polarisée dispose de deux broches
dont une est plus large que l’autre. Une che de terre dispose de
deux broches et d’une troisième pour le raccordement à la terre.
Cette broche plus large ou cette troisième broche est destinée
à assurer la sécurité de l’utilisateur. Si la che équipant l’appareil
n’est pas compatible avec les prises de courant disponibles, faire
remplacer les prises par un électricien.
The system heat vents located on each side dissipate heat. Do not block these openings. Leave at least 5 inches of space at the rear and 2 inches of space at the
sides of the switch for proper ventilation. Be reminded that without proper heat dissipation and air circulation, system components might overheat, which could
lead to system failure or even severely damage components.
WARNING: To prevent the Gigacore26i (with PoE) from overheating, do not operate it in an area that exceeds the maximum recommended ambient temperature
of 50°C for the Gigacore 26i and 40°C for the Gigacore 26i with PoE.
POWER CABLE:
Use only approved power cables. If you have not been provided with a power cable for your system or for any AC powered option intended for your system,
purchase a power cable that is approved for use in your country. The power cable must be rated for the product and for the voltage and current marked on the
product’s electrical ratings label. The voltage and current rating of the cable should be greater than the ratings marked on the product.
DISCONNECT DEVICE:
The plug- IEC socket combination must be accessible at all times, because it serves as the main disconnecting device.
SAFETY CLASSIFICATION OF TRAFFIC PORTS
■ Serial port has a safety status of EARTHED SELV
■ 10/100/1000BaseT ports have a safety status of UNEARTHED SELV.
SAFETY CLASSIFICATION OF POWER INPUTS
■ Backup power port:
12V connections have a safety status of EARTHED SELV
-54V connections have a safety status of UNEARTHED SELV
■ Mains Input – IEC connection has a safety status of PRIMARY CIRCUIT.
Page 4
Compliance information
FCC Compliance Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two condiftions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received; including interference that may cause undesired operation.
■ IMPORTANT NOTICE: DO NOT MODIFY THIS UNIT!
This product, when installed as indicated in the instructions contained in this manual, meets FCC requirements. Modications not expressly approved by
Luminex Lighting Control Equipment nv may void your authority, granted by the FCC, to use the product.
■ This Equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are
designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment
generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to
radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct
the interference at his own expense.
Industry Canada Compliance Statement
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
European Community Compliance Statement
This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take
adequate measures.
Disposal of Waste Equipment by users in the European Union
Information for Users on Collection and Disposal of Old Equipment
This symbol on the products, packaging, and/or accompanying documents means that used electrical and electronic products should not be mixed
with general household waste.
For proper treatment, recovery and recycling of old products, please take them to applicable
collection points, in accordance with your national legislation and the Directives 2002/96/EC.
By disposing of these products correctly, you will help to save valuable resources and prevent any potential negative eects on human health and
the environment which could otherwise arise from inappropriate waste handling.
For more information about collection and recycling of old products, please contact your local municipality, your waste disposal service or the point
of sale where you purchased the items.
[For business users in the European Union]
If you wish to discard electrical and electronic equipment, please contact your dealer or supplier for further information.
[Information on Disposal in other Countries outside the European Union]
This symbol is only valid in the European Union. If you wish to discard these items, please contact your local authorities or dealer and ask for the
correct method of disposal.
4
Page 5
Warranty information
Limited warranty
Unless otherwise stated, your product is covered by a two (2) years parts and labor limited warranty. It is the owner’s
responsibility to furnish receipts or invoices for verication of purchase, date, and dealer or distributor. If purchase date
cannot be provided, date of manufacture will be used to determine warranty period.
Returning under warranty
Any Product unit or parts returned to Luminex LCE must be packaged in a suitable manner to ensure the protection
of such product unit or parts, and such package shall be clearly and prominently marked to indicate that the package
contains returned product units or parts. Accompany all returned product units or parts with a written explanation of
the alleged problem or malfunction.
Freight
All shipping will be paid by the purchaser. Items under warranty shall have return shipping paid by the manufacturer
only in the European Union.
Under no circumstances will freight collect shipments be accepted. Prepaid shipping does not include rush expediting
such as air freight. Air freight can be sent customer collect in the European Union.
Warranty is void if the product is misused, damaged, modied in any way, or for unauthorized repairs or parts.
Registration
Use your favorite web browser, and visit http://www.luminex.be/support.php?show=registration
to register your product online.
By registering, you become eligible to receive the following:
■ Technical support information
■ Software update and upgrade notices
■ Hardware warranty information
In the box
1 x LU 01 00052 GigaCore 26i with PoE26i or 1 x LU 01 00052-POE GigaCore 26i with PoE
1 x Quick Start Guide
1 x Safety instructions.
5
Page 6
Table of Content
■Safety instructions 2
■Compliance information 4
■Warranty information 5
■Limited warranty 5
■Returning under warranty 5
■Freight 5
■Registration 5
■In the box 5
■Description 8
■Front panel 8
■Rear panel 8
■LED indicators 9
■Installing Mini GBIC (SFP) transceivers 9
■Connecting the Redundant Power Supply Unit 10
■GigaCore features explained 11
■RLin k X 11
■Groups 12
■MultiLinkX 13
■Starting 15
■Connection to the web interface 15
■Status Page 16
■Global Page 17
■RLink X 21
■Groups 22
■MultiLinkX 23
■PoE 25
■Prole Manager 27
■Reset the unit 30
■Reset 30
■Reload Default 31
■Factory Reset 31
■Specications 32
■Additional documentation 34
Page 7
This page is intentionally left blank
7
Page 8
Description
Front panel
12 3574689
1 - OK LED: Indicates the general status of the switch
2 - PoE LED: Indicates the status of the PoE functionality
and the PoE supplies (GigaCore 26i with PoE only)
3 - RLinkX: Indicates the RLinkX status
4 - Power: Indicates the status of the power supplies
5 - Mode LED: Indicates the selected state for the port’s
Mode LEDs (see “LED indicators” on page 9)
NOTE : PORT 21 TO 24 ARE DUAL MEDIA PORTS.
RJ45 PORTS 21 TO 24 CAN’T BE USED AT THE SAME TIME AS SFP PORTS 21 TO 24.
SFP PORTS 21 TO 24 HAVE PRIORITY OVER RJ45 PORTS 21 TO 24.
Rear panel
10
6 - Mode button: Use this button to browse through the
dierent states for the Port Mode LEDs
7 - 26 x Port Mode LED: According to the selected state,
the LED will show dierent colours
8 - 26 x Port Link/Speed LED: Shows the current speed
and link activity of a port
9 - 24 x RJ45 10/100/1000Mbps port
10 - 6 x SFP cage for Mini-GBIC transceiver
12
1 Serial port: RS232 console port on RJ45
2 RPSU port: Connect here the optional Redundant Power Supply Unit
3 Power: IEC inlet
3
8
Page 9
LED indicators
The LED indicators of the GigaCore 26i and 26i (with PoE) show General, PoE, RLinkX, Power and Link/Speed statuses.
Switch LEDColourDescription
OK (General status LED)GreenAll OK
Green blinkUnit is writing to the ash. Do not disconnect power
OrangeTemperature warning
Red blinkTemperature or Fan error
Red/Green blink The unit is ashing new rmware. Do not disconnect power
PoE LED (GigaCore 26i with PoE only) GreenInternal PoE supply OK and RPSU connected. PoE functionality OK
OrangeInternal PoE supply OK (no RPSU connected) - PoE functionality OK
Red blinkPoE supply or PoE functionality error
RLinkX LEDGreenRLinkX is active
Power LEDGreenInternal Power supply OK and RPSU connected
OrangeInternal power supply OK (no RPSU connected)
Red blinkPower error
Port LEDStatusDescription
LinkONo link
GreenGigabit connection
Orange10/100 Mbps connection
BlinkActivity
The LED indicators of the GigaCore 26i
GigaCore 26i with PoE26i are meant to provide the user a maximum of information. Thanks to the mode button, the user
can get all necessary information at a glance. Simply press the mode button to browse through the dierent states.
StateMode LEDPort Mode LEDDescription
GroupsWhiteGroup colourThe LED colour indicates the group assignation of the port
RLinkXBlueBlueIndicates a redundant port
MultiLinkXMagentaMagenta
White
PoEYellowYellowPoE is activated on this port
OrangePort is sourcing a device
RedError on PoE
Dark ModeOOAll port’s LEDs are switched o. Switch’s status LEDs remain
MultiLinkX is enabled on this port
MultiLinkX is active on this port
available. Ideal to reduce light emmited by the switch
Installing Mini GBIC (SFP) transceivers
The GigaCore 26i (with PoE) comes with six SFP cages at the front of the unit. These cages accept mini GBIC transceivers.
Recommended transceivers
In order to get best the performances, Luminex recommends the use of the following transceivers:
LU 90 00871 GigaCore 1.25Gd Multi-Mode ber transceiver
LU 90 00872 GigaCore 1.25Gd Single Mode ber transceiver
LU 90 00874 GigaCore 1.25Gd copper RJ45 transceiver
9
Page 10
Connecting the Redundant Power Supply Unit
The GigaCore 26i (with PoE) provides a connector to an optional Luminex Redundant Power Supply Unit, providing
redundancy on power level for both the mains as the PoE power.
Attach only the following RPSU to the RPSU connector: LU 01 00061 GigaCore RPSU MKII
THIS UNIT HAS MORE THAN ONE POWER SUPPLY. DISCONNECT ALL POWER SUPPLIES BEFORE
SERVICING TO AVOID ELECTRIC SHOCK.
Connect the power cable to the device, and connect the other side of the cable to the mains. It will take approximately
20 seconds for the switch to boot up. You’ll then be able to use it.
10
Page 11
GigaCore features explained
RlinkX
RlinkX
RlinkX
The GigaCore range of switches oers a bunch of unique features which greatly simplify your everyday job.
These features will be explained in the following pages :
RLinkX
RLinkX, which stands for Redundant Link by LumineX, is an automated system to easily create redundant paths between
your GigaCore switches. Switches automatically create active and backup paths, providing an eortless methode to
create safe networks.
If one of the active paths fails, the switches will enable a backup path, in a seamless manner.
By default, all GigaCore ports have RLinkX enabled, which means you can interconnect any GigaCore switch between
each other. All redundant paths will be created automatically by the switches, no need for conguration.
Active path
Backup path
To create redundant paths with RLinkX, simply connect a minimum of two links between to GigaCore switches. The blue
RLinkX LEDs of the connected ports will turn on, indicating the redundancy is active and available.
If you port’s RLinkX LED turns o, this means you lost one of your redundant path.
Step 1
Active linkBackup link
User connect two
switches with two links.
The switches
automatically create a
backup link.
Faulty linkBackup link
Step 2
Active link becomes
unavailable (cable or
bre issue)
Step 3
Faulty linkActive link
Backup link becomes
active automatically
20 to 40ms
11
Page 12
Groups
Groups function allows the user to segment the network into several subnets. The main benet of this function is that no
subnet will aect the other ones, on protocol level.
The user can create several groups on the network, and each device included in a group will be able to communicate
with devices of this group only. This will result in a better bandwidth , and no protocol conict.
Light Over IP Converter
Sound Over IP processor
Video over IP OUT
Inter Switch Links
(ISL)
Video over IP INSound Over IP Console
Light Over IP Console
Three groups have been created in the above illustration: Red, Green and Blue groups. Each device included in each
group can communicate with devices from the same group. Thus, the sound console and the sound processor can talk
to each other, without being ooded by packets streamed by the two other groups.
The GigaCore switches oer 20 groups, to which the user can assign any of the ports. Two devices must be part of the
same group to communicate.
When more than one switch is used in a group based network, the Inter Switch Link group (ISL Group 0) must be used to
forward the group’s packets between switches.
12
Page 13
Tx:
400Mbps
Tx:
400Mbps
Tx:
400Mbps
Tx:
400Mbps
Rx:
400Mbps
Rx:
400Mbps
Rx:
400Mbps
Rx:
400Mbps
1000Mbps
Tx:
400Mbps
Tx:
400Mbps
Tx:
400Mbps
Tx:
400Mbps
Rx:
400Mbps
Rx:
400Mbps
Rx:
400Mbps
Rx:
400Mbps
1000Mbps
MultiLinkX
Most of the time, a redundant link set with RLinkX between two GigaCore switches will t for every day event. A
1000Mbps link is more than enough for most of the current applications. However, it can happen that you’ll need to
transfer a larger amount of data between the switches.
Below is an example where four video transmitters will needs to transmit four streams to each dedicated receiver. Each
stream requires a throughput of 400Mbps, which represents 1600Mbps in total.
However, one link only is active between the switches, as the other link is used in case of link failure. So a maximum
of 1000Mbps data transfer can be achieved on this link. In the above example, we need 1600Mbps of throughput to
transfer all four video streams between the switches. This is not enough, the link between the switches will create a
bottleneck, resulting in data loss or data delay. The video streams won’t be delivered in time., and will create lag in the
video output.
The solution? MultiLinkX !
13
Page 14
MultiLinkX enables you to gather several links together, and turn them into one virtual link. This provides you with more
bandwidth available between the switches, and thus more throughput. MultiLinkX can accept as many ports as you
want into an aggregation, and up to 8 aggregations can be created on a switch.
Working with PtP
When working with PtP (Precision Time Protocol), you’ll notice an inverted PTP icon to indicates the PTP enabled port in
an aggregation. You must always link the lowest ports of the active aggregation to each other to avoid problems with
PTP. Best is to never create a cross link between ports in a dierent order.
1+1 is not 2 !
By adding an additional link into the aggregation, we can easily think we’ll have the addition of all bandwidth available
per cable.
However, MultiLinkX relies on LACP (Link Aggregation Control Protocol). The algorythm used by the protocol requires
several parameters of the Ethernet frame to decide to which port of the aggregation the frame will be forwarded to.
The protocol uses the following parameters:
Source Mac Address
Source IP Address
Source Port (TCP/UDP)
Destinatation IP address
Destination Port (TCP/UDP)
The ports included in the aggregation
In some circumstances, it might happen that several data streams will be forwarded to the same port. To know where
the data stream will be forwarded to, you can have a look at our aggregation planning web page.
Simply type the following link into the address bar of your favorite web browser:
http://IPOFMYSWITCH/aggregation_code.html
According to the parameters of your Ethernet frame, the page will show you wich port will be in use. This allows you to
predict, but also to solve some problems. In the unlikely event of an overloaded link in an aggregation, user can solve the
problem simply by changing the appropriate IP address for the source for instance.
MultiLinkX technology is available on the ISL ports only !
It is also a good habit to allocate the specic number of link in an aggregation to fulll your throughput
requirement, plus one link. If one link fails, you’ll still have the minimum number of necessary link to tranfer all
your data !
14
Page 15
Starting
The device operates with an AC voltage between 100V and 240VAC within a frequency range of 50Hz to 60Hz.
An IEC socket is located at the rear of the unit. Please use an IEC plug compliant cable to feed power to the unit.
Luminex recommends the use of a power cable, tted with a locking mechanism to ensure a reliable connection to the
device.
Connection to the web interface
Every GigaCore switch embeds a built-in web server, which excludes the need of a dedicated application to congure
the unit. Browsers such as Chrome, Internet Explorer (IE 9 minimum), Firefox or Safari can be used to reach the web
server.
Every unit comes with a default IP address, visible at the rear of the unit. Set your computer with an IP address within the
same subnet (do not use the same IP address!)
■ Example 1: Switch IP address: 192.168.1.1, Netmask: 255.255.255.0
Computer IP address: 192.168.1.2, Netmask 255.255.255.0
■ Example 2: Switch IP address: 192.168.2.112, Netmask: 255.255.0.0
Computer IP address: 192.168.2.113, Netmask 255.255.0.0
Connect your computer to the switch with a Cat5E network cable at least, and launch your favorite web browser. Type
the IP address of the switch in the address eld, and press enter. You’ll be prompted to enter a login:
Use admin in the login eld, and leave the password led blank. You reach the status page of the GigaCore switch.
15
Page 16
Status Page
The status page is split into several panes that will be described below:
Switch image :
The top image gives you a quick overview of the switch port status (front and rear). Actives ports are lled with the
following colours:
■ Orange: 100Mbps link
■ Green: 1000Mbps (1Gbps) link
RPSU connectors:
On the right hand side of the switch’s image, two squares indicates the status of the RPSU connectors (PSU and PoE).
Three dierents status colors are available:
NO RPSU CONNECTED
Wink:
The feature allows you to easily identify a GigaCore switch in a stack of device. Click on the Luminex Logo on the switch
image, all four status LEDs on the left hand side of the switch will start blinking three times.
Main menu :
On the left hand side, you can nd the main menu. Click on any tab to reach the corresponding menu.
RPSU CONNECTED
POWER ERROR
Port status :
This table gives you a quick overview of the switch’s ports settings. Parameters such as port speed and legend can be
modied in the following menu: Global > Port Settings (see “Port settings” on page 18)
IP Settings :
Find here all the network settings of the switch. These parameters can be modied in the following menu: Global >
Device Settings (see “Device setttings” on page 17)
System Info :
Find here all the device’s info such as serial number, device name, system identier, MAC address, system description, and
if a conguration prole is currently in use. These information can be modied in the following menu:
Global > Device Settings (see “Device setttings” on page 17)
16
Page 17
Global Page
The global page contains four sub menus that are described below:
Device setttings
This menu allows you to change IP and ID settings of the unit, and also the brightness of the front panel’s LEDs.
IP settings: Assign here the IP address of your switch. This IP address will be used to reach the switch’s web interface.
If your network is equipped with a DHCP server, you can enable the DHCP client of the switch, for it to receive
automatically an IP address from the DHCP server.
However, mind that if DHCP is enable, you can still assign an IP address to the switch. This IP address will be used if there
is no DHCP server available at boot up.
Enter your default gateway IP address if your switch needs to be reached from a routed network.
ID settings: Set here the name of your switch, and add a description to easily identify your switch in your network.
LED Brightness: Set here the level of brightness you wish to apply to the front panel’s LEDs. This fader brings an ideal
way to reduce the light emmited by the switch.
17
Page 18
Port settings
This menu allows you to change the port’s speed, and add a legend to each port.
Port speed drop down menu oers the folowing speed :
■ Disabled : Disable the port. Port will appeared grayed out on the top switch image
■ Auto : The port detects automatically the speed of the connected device (default)
■ 10Mbps HDX : 10Mbps Half Duplex
■ 10Mbps FDX : 10Mbps Full Duplex
■ 100Mbps HDX : 100Mbps Half Duplex
■ 100Mbps FDX : 100Mbps Full Duplex
■ 1Gbps FDX : 1000Mbps Full Duplex
18
Page 19
Utilities
This page brings you the tool to reset your unit in dierent ways, and to set some default security parameters.
Reset
This menu allows the user to bring the switch into dierent levels of reset.
Preserve IP settings
Tick the upper check box if you wish to bring the unit back to the default settings, and keep the actual IP parameters set
on the switch.
If you leave this checkbox unticked, the unit’s IP address will be set back as the one printed at the back of the unit.
Preserve all user proles
Tick the lower check box if you wish to bring the unit back to the default settings, and keep the proles stored in the
prole manager.
Press the Apply Reset button once you’ve selected the appropriate options for your reset. Reset the units with the two
unticked checkboxes will bring the unit back to its factory settings.
Reboot
Press the “Reboot Now” button to reboot the unit. All your parameters will be preserved
Security
User can set here a password to protect the web interface’s access.
Default login of the web interface is admin, there is no default password. Click on Change Password to apply your new
settings.
Default Prole
By clicking on the checkbox, the user can protect the prole stored in slot 1 from being deleted or overwritten.
When the user performes a Reload Default from the front panel’s mode button (see “Reload Default” on page 31), the
unit will be reloaded with prole 1. This makes a handy tool to easily recall your favorite prole.
Once the rst prole is protected and set as default prole, a lock will appear on the prole’s tab.
Locked Prole
19
Page 20
Firmware
This menu allows you to upload a new rmware to the switch. Please visit the support section of our web site to get the
latest rmware available for your GigaCore switch.
To upgrade the switch, simply click on the Upload Firmware button, and select the rmware on your computer. The
upgrade procedure takes about 4 minutes to complete.
!! WARNING : DO NOT DISCONNECT POWER DURING FIRMWARE UPGRADE !!
Alternate image
If you’re not satised with your recently uploaded rmware, you can always reload the previous rmware that was
installed on the switch. Press the Activate alternate rmware button to reload the previous rmware. The downgrade
process takes about 1 minute.
20
Page 21
RLinkX
1
2
3
RLinkX Settings
RLinkX is meant to provide a trully plug and play redundant system (see “RLinkX” on page 30)
This menu allows you to enable / disable RLinkX on each port of the switch. An enabled RLinkX port is represented by a
blue ring around the port.
To enable / disable a port, follow this procedure:
■ 1- Click on the port(s) you wish to select. Selected ports will be highlighted.
■ 2- Enable / Disable the port(s)
■ 3- Click Apply to submit the changes
It is sometimes useful to disable RLinkX on some of the GigaCore switch’s port. As an example, Ethersound devices do no
comply with the RLinkX packet the switch sends out periodically, to maintain its redundant link.
The best practice is thus to disable RLinkX on the ports where end devices such as Ethersound or REAC need to be
connected.
Once a minimum of two links are connected between two switches, blue LEDs on these ports will light up, indicating
the redundancy is active and operational.
Advanced
MultiLinkX, our aggregation protocol , has been designed to work awlessly with RLinkX, our redundancy protocol.
To provide users with a more advanced and ecient method to recover topology in case of link failure, Luminex has
developped a new method for best link cost calculation in an aggregated network, based on the available bandwidth
per link.
This calculation method is the default one when using MultiLinkX.
However, in the case you’d have to connect your aggregated links to an exisiting IT network, best is to select the usual
path cost calculation, based on RSTP.
To select this method, simply click on the Advanced button, and select the RSTP method, and press apply.
Indication
When a user connect a minimum of two aggregated links between two switches, it is easy to think these are redundant
links. However, this is seen as a unique link between the switches. This is why the RLinkX LED won’t lit up in this case. This
is a normal behaviour.
21
Page 22
Groups
Groups :
Groups is a technology which oers the user to easily segment its network into several subnets (see “Groups” on page
12)
This menu allows you to assign ports into the 20 embedded groups of the switch.
A group is a combination of port, and user can assign as many port as wanted into a group.
The GigaCore range oers three types of groups :
■ Group 0 (ISL) : This group is dedicated to the Inter Switch Links. This is the name given to the interconnection links
between GigaCore switches in a network. The ISL links are meant to forward the groups based packets. In most case,
the ISL links will be the redundant links (RLinkX). If you already have connected your redundant links, simply click on the
advanced button, and press “Retrieve from RLinkX). The switch will automatically assign the redundant ports as ISL
ports.
■ Group 1 (Management). This group is dedicated to the management of the switch (web interface). You need to
have at least one port of the switch assigned to that group, to be able to reach the web interface. In a star, ring or mesh
network topology composed of GigaCore switches, you need to have at least one port of one switch set in this group,
to be able to reach the web interface of all switches.
■ Groupe 2 to 20 : These are the generic groups to be used for any purpose, such as sound, light, intercom, video....
To assign ports into a group, follow this procedure :
■ 1- Select the group you wish to assign ports to. Use the colored index of the jog, and rotate the jog to change the
group. If you wish to change the name of the group, simply click on the Name button
■ 2- Select the ports you wish to assign to the group. Selected ports will be highlighted.
■ 3- Click on the Assign button to assign ports to the group. If you’re not satised with the selection of ports, and wish
to restart your selection, simply click on the Clear button to reset the selection.
■ 3- Click Assign to submit the changes. Ports colour will match the selected group index colour.
2
22
3
1
Page 23
MultiLinkX
MultiLinkX allows you to gather several links together, in order to increase the available bandwidth between switches.
MultiLinkX is available for ISL ports only.
To enabled MultiLinkX, sinply select group zero (ISL) in the group page, and tick the box to enable MultiLinkX. Press
Apply to submit the changes.
Once MultiLinkX is enabled on the ISL ports, a Magenta bar will appear below the selected ports.
Once MultiLinkX is active on the ISL ports, a White bar will appear below the selected ports.
23
Page 24
Advanced :
PLEASE KEEP IN MIND THE WEB INTERFACE OF A SWITCH CAN ONLY BE REACHED THROUGH A
PORT ASSIGNED IN THE MANAGEMENT GROUP FROM THE SWITCH YOU’RE CONNECTED TO, OR
FROM ANOTHER SWITCH THROUGH AN ISL PORT. YOU NEED AT LEAST ONE PORT ASSIGNED IN
THE MANAGMENT GROUP IN YOUR ENTIRE NETWORK, TO REACH ALL YOUR GIGACORE’S WEB
INTERFACES.
The advanced pane oers the user to access extended parameters such as :
VID : Luminex groups technology relies on the 802.1Q VLAN protocol. By default, Luminex groups have a default VLAN
ID. If required, user can change the VID of the group. Mind that if you wish to change this VID, you’ll need to change it on
each switch using this group.
■ Snooping : This button activates IGMP snooping. IGMP snooping is a smart way to manage multicast packets, and
forward them to the registered ports. The main advantage of the IGMP snooping is to avoid ports to be ooded with
unrequested packets.
■ Querier : IGMP snooping requires at least one switch in a group to act as a querier. Querier register the multicast
packets to the corresponding ports. If more than one querier is activated per group, the switch with the lowest IP
address will be elected as querier. This election process is automated.
PTP V2 : The Luminex GigaCore series supports Precision Time Protocol Version 2
PtP is a protocol used to synchronize devices within a network, especially in audio over IP application.
With PtP V2, the GigaCore can be part of the clock domain, which is necessary for protocols such as AES67.
User can enable / disable PTP communications within the selected group, by validating the tick box, and by selecting the
mode that better ts for the setup.
■ E2E - End to End
■ P2P - Peer to Peer
Domain : Please enter here a vale for your PtP domain
Press Apply to submit your changes. Mind you can have only one PtP setup per switch, so in one group only.
In the status page, a stopwatch will be displayed for every port set in the group associated to a PtP domain.
24
Page 25
PoE
PoE (Power over Ethernet) is a convenient way to transport both data and power over the same network cable, and thus
powering a device with its data cable. Your GigaCore switch can then be a data connection box and power source for
your end devices.
PoE supply will provide PoE enabled port as a default conguration (see illustration above).
A PoE enable port is displayed with a yellow square inside. When the switch is currently sourcing a PoE device through a
port, the square will turn orange, as the port PoE LED on the front.
The PoE status page will oer the following info per port :
■ The Powered Device Class (0,1,2...)
■ The power consumption (Watts)
■ The current consumption (mA)
■ The priority (low, high, critical)
■ The port status
On the right hand side of the page, a bargraph is here to display the current power consumption of the switch. The
switch can deliver a total of 370W to share on the 24 RJ45 front ports, with a maximum of 30W per port (PoE+ compliant).
Two arrows will indicate the following values :
- Allocated power: based on the classes of the connected PoE devices, the switch will allocate the necessary power to
the PoE supply. This value is represented with a gray index.
- Actual usage: A green index will show the current power delivered by the PoE supply.
25
Page 26
Settings
The setting page allows you to assign the following PoE parameters to the 24 front ports :
■ Enable / Disable PoE per port
■ Assign a priority on the port
To change the PoE parameters of one or several ports, please apply the following procedure :
1
2
3
4
■ 1- Select the port(s) you wish to modify
■ 2- Enable or disable these port(s)
■ 3- Select a priority for the port(s)
■ 4 -Apply your new parameters
The priority of a port is used when the switch reaches the limit of its maximum output power.
In the unlikely situation of PoE devices requiring too much power to the switch, the switch will rst disable the port(s)
with the lowest priority.
26
Page 27
Prole Manager
The prole manager allows the user to easily save / recall / export / import a conguration.
A prole will contain the following parameters :
■ Device settings
■ Port settings
■ RLinkX settings
■ Groups settings
■ PoE settings.
In this way, user can create a comprehensive conguration of a switch, save it as a prole, and recall it later when needed.
A maximum of ten proles can be saved on a GigaCore switch.
The switch also oers to export / import a prole through a computer, providing user an easy way to exchange prole
between switches.
From one switch, user will select a prole to export in a computer. Then, from the same computer, user will be able to
load this prole into the empty slot of a secondary switch.
Exchanging proles between switches can be a time saving process; User may start with one base conguration, and
export it to the other switches for minor changes. These newly created proles will then be saved locally.
■ Save a prole
If you wish to save the actual conguration of your switch, rst select an empty slot amongst the 10 available slots.
Press the Save button. A small window will pop-up, to enter the name of the prole.
27
Page 28
Click on Ok. Your prole is now saved in the switch
It is a good habit to always create a default conguration for your switch!
■ Recall a prole
To recall a prole, select it amongst the ten available proles in upper tab. Here, you can preview the content of this
prole.
Click on the Recall button. A window will pop-up to let you select either to reload the entire prole settings (Recall all),
including the network settings, or just the switch conguration (No Network Settings). This very useful feature makes the
exchange of prole between switches possible. You can thus avoid to get twice the same IP address on the network, by
using the same prole.
28
Page 29
Once you’ve selected the prole you wish to recall, the switch will reboot, and will reload the requested prole.
The recall process can take a minimum of 30 seconds, to a maximum of 2 minutes.
If you intend to reload a prole with a dierent IP address, you can try to reach the newly loaded IP address after about
50 seconds, manually from the switche’s web interface.
Otherwise, the web interface of the switch will be automatically reloaded after a maximum of 2 minutes. Your
computer’s IP address needs to be set in the same subnet as the loaded prole’s IP address.
PLEASE KEEP IN MIND THE WEB INTERFACE OF A SWITCH CAN ONLY BE REACHED THROUGH A
PORT ASSIGNED IN THE MANAGEMENT GROUP FROM THE SWITCH YOU’RE CONNECTED TO, OR
FROM ANOTHER SWITCH THROUGH AN ISL PORT. PAY ATTENTION THE PROFILE YOU’RE GOING
TO RECALL IS NOT CHANGING YOUR LINK TO THE WEB INTERFACE OF THE SWITCH YOU’RE
WORKING WITH.
ALSO PAY ATTENTION TO THE IP ADDRESS THAT WILL BE RELOADED WITH THE PROFILE WILL
NOT CONFLICT WITH ANOTHER IP ON THE NETWORK. SWITCH’S WEB INTERFACE MAY BECOME
UNRESPONSIVE IN CASE OF IP CONFLICT.
■ Export a prole
To export a prole, select it amongst the ten available slots. Once selected, click on Export to download the prole to
your computer. You’ll be asked to select the download location of the prole on your computer.
■ Import a prole
To import a prole, select an empty slot in the prole manager tab. Once selected, click on Import to select the prole
on your computer. Once the le is selected, validate to import the prole in the empty slot.
A message will conrm the successful import process.
■ Delete a prole
To delete a prole, simply select it amongst the ten available slots. Click on Delete. The prole will automatically be
erased, and the preview window will display a blank space.
WHEN USER SAVE A PROFILE, THE OK LED WILL BLINK GREEN FOR ABOUT 5 SECONDS, TO INDICATE
THE WRITING PROCESS TO THE FLASH MEMORY;
PLEASE DO NOT SWITCH THE UNIT OFF WHILE THE OK LED IS BLINKING GREEN ! YOUR SWITCH
CONFIGURATION MIGHT BE ERASED DURING THE NEXT BOOT UP.
■ Delete a prole
To delete a prole, simply select it amongst the ten available slots. Click on Delete. The prole will automatically be
erased, and the preview window will display a blank space.
■ About the default prole
As detailed on page 19, the rst slot of the prole
manager can be locked. This will be indicated by a padlock
on the prole itself. This prole can’t be erased nor
overwriten, unless you unlock it. To unlock the prole,
untick the checkbox in the global>utility page (see page
19).
29
Page 30
Reset the unit
Hold the
reset button
Release the button =
Reset
Release the button =
Cancel
5sTiming
Function
5s5s
RED Blink
In the case you need to reset the unit without the web interface, the GigaCore 26i and GigaCore 26i with PoE oers
dierent levels of reset, based on the ones you can nd on the web interface.
■ Reset: The unit is brought back to its default conguration, with the default IP address printed at the back of the unit.
Proles stored in the unit are preserved.
Default login: admin
Password: No password
■ Reload Default: Prole stored in slot 1 is reloaded. The “Reload Default” is available only if the prole stored in slot 1
has been locked through the utility menu (see “Default Prole” on page 19). If this prole is set with a password, the
user will need to enter it through the web interface to access the switch’s menus.
Default login: admin
Password: The one set for the prole (if there is one)
■ Factory Reset: Unit is fully reset, proles stored in the unit are erased.
Default login: admin
Password: No password
Reset
Condition 1: Unit is currently running
Condition 2: There is no prole set as default prole (see “Default Prole” on page 19)
Hold the mode button for at least ve seconds to see the four status’ LEDs blinking red. Releasing the mode button
while the LEDs are blinking red will reset the unit.
Be aware that releasing the mode button during the rst 5seconds before LEDS blink red will cancel operation.
Be aware that releasing the mode button during the 5seconds after LEDS blink red will cancel operation.
30
Page 31
Hold the
reset button
Release the button =
Reload default
Release the button =
Reset
5sTiming
Function
5s5s
GREEN BlinkRED Blink
Hold the reset button
while powering the unit
Release the button =
Factory Reset
Release the button =
Cancel
Timing
Function
5s18s
RED Blink
Reload Default
Condition 1: Unit is currently running
Condition 2: Prole stored in slot 1 needs to be locked through the utility menu (see “Default Prole” on page 19)
Hold the mode button for at least ve seconds to see the four status’ LED blinking green. If you release the button while
the status’ LED are blinking green, the unit will reload the prole stored in slot 1.
If you wait an addtional 5 seconds, the status’ LEDs will blink red, to provide you with a reset.
Releasing the mode button while the LEDs are blinking red will reset the unit.
Be aware that releasing the mode button during the rst 5seconds before LEDS blink green will cancel operation.
Be aware that releasing the mode button during the 5seconds after LEDS blink red will cancel operation.
Factory Reset
Condition 1: Unit is o
Hold the mode button while connecting the unit to mains. After few seconds, the four status’ LEDs will start blinking red.
Releasing the mode button while the LEDs are blinking red will factory reset the unit.
Be aware that releasing the mode button before LEDs blink red will cancel operation.
Be aware that releasing the mode button after LEDs blink red will cancel operation.
31
Page 32
Specifications
Sheet 1/2
Connectivity
■ 24 x 10/100/1000Mbps RJ45 connec tors (including 4 dual
■ Network
■ Power
■ Serial■ 1 x serial console on RJ45 (RS232)■1 x serial console on RJ45 (RS232)
media ports)
■ 6 x SFP cages, compliant with 10/100/1000Mbps Mini GBIC
transceiver (including 4 dual media ports)
■ 1 x IEC inlet
■ 1 x por t for redundant power supplies
■ GigaCore 26i■ GigaCore 26i with PoE
■ 24 x 10/100/1000Mbps RJ45 connec tors (including 4 dual media
ports)
■ 6 x SFP cages, compliant with 10/100/1000Mbps Mini GBIC
■ Port Sensing■ Auto negotiation■ Auto negotiation
■ Auto Crossover■MDI / MDIX (allow to use straight or cross wired cable)■ MDI / MDIX (allow to use straight or cross wired cable)
■ Auto Sensing■ Full or Half Duplex (Gigabit is Full Duplex)■ Full or Half Duplex (Gigabit is Full Duplex)
Status Report
■ Status available throught the mode button and mode LEDs:
■ Ethernet Port Setting
■ Ethernet Por t Speed
■ OK (D evice)■Status LED (Green / Red LED)■ Status LED (Green / Red LED)
■ PoE (Supply)
■ RLinkX■ Status LED (Green)■ Status LED (Green)
■ Power■Status LED (Green / Orange / Red LED)■Status LED (Green / Orange / Red LED)
■ White LED: Groups assignation
■ Blue LED: RlinkX status
■ Yellow LED: PoE status
■ O: Dark mode
■ Status available through status LED
■ Orange: 100Mbps link
■ Green: 1000Mbps link
■■ O
■ Status available throught the mode button and mode LEDs:
■ White LED: Groups assignation
■ Blue LED: RlinkX status
■ Yellow LED: PoE status
■ O: Dark mode
■ Status available through status LED
■ Orange: 100Mbps link
■ Green: 1000Mbps link
■ Status LED (Green / Orange / Red LED)
32
Page 33
Sheet 2/2
Management
■ Conguration■Through the built-in web server■Through the built-in web ser ver
■ GigaCore 26i■ GigaCore 26i with PoE
Power Input
■ Power Input
■ Backup Power Input■ +12VDC - 2,5A on Molex 14 pins connector■ +12VDC - 2,5A on Molex 14 pins connector
■ Backup PoE Input■-54VDC - 6,5A on Molex 14 pins connector ■-54VDC - 6,5A on Molex 14 pins connector
■ Power Consumption■30W■ 430W
■ 10 0-240 VAC
■ 50-60Hz
■ 0,5 - 0,29A
■ 10 0-240 VAC
■ 50-60Hz
■ 4,9 - 2,2A
Environmental
■ Operating Temperature■ 0 to +50 °C■ 0 to +40 °C
■ Storage Temperature■ -10 to +70 °C■ -10 to +70 °C
■ Humidity (non condensing)■ 5 to 95 % RH■5 to 95 % RH
Physical
■ Enclosure■ Metal housing■ Metal housing
■ Dimensions ( W x D x H)
■ Packaging
■ Weight■ 3.5Kg■ 4Kg
■ 482 x 270,3 x 44 mm
■ 19” x 10,64” x 1.73”
■ 547x 425 x 80 mm
■ 21,53” x 16,73” x 3,14”
■ 482 x 270,3 x 44 mm
■ 19” x 10,64” x 1.73”
■ 547x 425 x 80 mm
■ 21,53” x 16,73” x 3,14”
Approvals
■ CE
■ IEC 60950-1
■ EN 60950-1
■ UL 60950-1
■ CAN/CSA- C22.2 No.60950-1
■ FCC Part 15, CFR 47, Class A
■ CAN/ICES-003(A)
■ EN55022 (CISPR22)
■ EN5024 (CISPR24)
■ RoHS Compliance
■■ ■■
■■ ■■
■■ ■■
■■ ■■
■■ ■■
■■ ■■
■■ ■■
■■ ■■
■■ ■■
■■ ■■
33
Page 34
Additional documentation
All additional documenttion can be downloaded from our web pages in the support section :
http://www.luminex.be
--> Support
The GigaCore 26i and GigaCore 26i with PoE user manual is available in the support section of our web site.
DISCLAIMER
Luminex LCE operates a policy of continuous development. Luminex LCE reserves the right to make changes and
improvements to any of the products described in this document above without prior notice. Specications are
subject to change without notice.
No part of this documentation may be reproduced or transmitted in any form or by any means, electronic or mechanical,
including photocopying and recording, without the prior written permission of Luminex.
The information in this documentation is supplied without warranty of any kind, either directly or indirectly, and is subject to
change without prior written notice. Luminex, its employees or appointed representatives will not be held responsible for any
damages to software, hardware, or data, howsoever arising as a direct or indirect result of the product(s) mentioned herein.
34
Page 35
This page is intentionally left blank
35
Page 36
36
Berkenlaan 8A
3940 Hechtel-Eksel
Belgium
T +32 11 812 189
info@luminex.be
support@luminex.be
www.luminex.be
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.