Luminex DMX8 MkII User Manual

Ethernet - DMX8 MkII Range
User Guide - V4 rev3
Ethernet - DMX8 MkII Range User Guide - V4 rev3
Document lu_01_00037_3_man
Copyright © 2003-2015 . All rights reserved.
The information in this documentation is supplied without warranty of any kind, either directly or indirectly, and is subject to change without prior written notice. Luminex, its employees or appointed representatives will not be held responsible for any damages to software, hardware, or data, howsoever arising as a direct or indirect result of the product(s) mentioned herein.
Issued by:
Publications Department, Luminex LCE, Berkenlaan 8A, Hechtel - Eksel, B-3940, Belgium. Documentation reviewed April 22, 2015, by Bart Swinnen. Printed in the EU.
Table of Contents
Warranty information........................................................................ 5
Limited warranty..........................................................................5
Returning under warranty..............................................................5
Freight........................................................................................ 5
General.......................................................................................... 6
Packaging.................................................................................... 6
Description.................................................................................. 6
Specification................................................................................ 6
Dimensions............................................................................... 6
Weight..................................................................................... 7
Electrical.................................................................................. 7
Connectors............................................................................... 7
Environmental........................................................................... 7
Connectivity.................................................................................... 8
Rear Panel – Side Panel.................................................................8
Mains.......................................................................................8
DMX input / output.................................................................... 9
Interface....................................................................................... 10
Front panel................................................................................ 10
Ethernet port..........................................................................10
DMX input / output..................................................................10
Status indication...................................................................11
Status indication...................................................................11
Front end display information....................................................11
Reset the node (Out of jail)....................................................... 13
Web interface................................................................................ 14
Status....................................................................................... 14
Setup........................................................................................ 15
Node...................................................................................... 15
DMX Routing........................................................................... 16
Merging Policies :..................................................................... 18
Inputs (Local mode).............................................................. 19
Inputs (IP Merging)...............................................................21
Outputs (IP Merging)............................................................21
Recover channel................................................................... 24
Network settings..................................................................26
IP Settings..........................................................................26
Global.................................................................................... 27
DMX details......................................................................... 27
Miscellaneous....................................................................... 28
Toolbox......................................................................................29
Profile manager....................................................................... 29
Snapshot manager................................................................... 30
Firmware upgrade.................................................................... 32
Toubleshooting........................................................................ 34
Additional Documentation................................................................ 35
Credits:..................................................................................... 35
Warranty information
Limited warranty
Unless otherwise stated, your product is covered by a two (2) years parts and labor limited warranty. It is the owner’s responsibility to furnish receipts or invoices for verification of purchase, date, and dealer or distributor. If purchase date cannot be provided, date of manufacture will be used to determine warranty period.
Returning under warranty
Any Product unit or parts returned to Luminex LCE must be packaged in a suitable manner to ensure the protection of such Product unit or parts, and such package shall be clearly and prominently marked to indicate that the package contains returned Product units or parts. Accompany all returned Product units or parts with a written explanation of the alleged problem or malfunction.
Freight
All shipping will be paid by the purchaser. Items under warranty shall have return shipping paid by the manufacturer only in the European Union . Under no circumstances will freight collect shipments be accepted. Prepaid shipping does not include rush expediting such as air freight. Air freight can be sent customer collect in the European Union.
Warranty is void if the product is misused, damaged, modified in any way, or for unauthorized repairs or parts.
Ethernet - DMX8 MkII Range Page 5 of 35
General
Packaging
- Ethernet-DMX8 MkII
1 x Ethernet – DMX8 MkII
1 x User guide
- Ethernet-DMX8/Truss MkII
1 x Ethernet – DMX8 MkII Truss
1 x Powercon male connector
1 x User Guide
Description
The Ethernet-DMX8 MkII is an Ethernet node that serves 8 x DMX512 outlets, compatible with the following protocols: DMX512, DMX512-A, RDM (ANSI E1.20), sACN (ANSI E1.31) and Art-Net™.
All 8 outlets can be used as input or output. The Ethernet links are 100BaseTx connections on shielded Neutrik RJ45 Ethercon connectors.
All configuration can be done over Ethernet through a built in website, or the front panel display.
This all comes in a 19'' unit high metal housing for the Ethernet-DMX8 MkII. The Ethernet-DMX8/Truss MkII comes in a rugged truss mountable metal housing with two M10 inserts. This enclosure allows to use the node in a truss, on a wall or as a table top device.
Specification
Dimensions
Ethernet-DMX8 MkII
482 x 183 x 44 (mm) 19” x 7,2” x 1,73” Package: 520 x 235 x 50 (mm)
Ethernet-DMX8 MkII Truss
240 x 180 x 90 (mm) 9,44” x 7,08” x 3,54” Package: 310 x 260 x 110 (mm)
Page 6 of 35 Ethernet - DMX8 MkII Range
Weight
Ethernet-DMX8 MkII: 2,3 kg Ethernet-DMX8/Truss MkII: 3,1 kg
Electrical
Ethernet-DMX8 MkII:
Voltages: 90 – 260 VAC Frequency: 47 – 63 Hz Rated power: 20 W Fuse: 125V – 250V, 1A, Slow blow only (5mm x 20mm)
Ethernet-DMX8/Truss MkII:
Voltages: 100 – 240 VAC Frequency: 50 – 60 Hz Rated power: 20 W Fuse: 250V 1A, Slow blow
Connectors
2 x shielded Neutrik RJ45 Ethercon connector (front and rear for Ethernet-DMX8 MkII, front and side for Ethernet­DMX8 MkII Truss) 8 x shielded Neutrik gold plated 5 pin XLR (female) 8 x optic and galvanic isolated DMX port 1 x IEC inlet with fuse holder (Rack version only) 1 x Neutrik Powercon inlet (Truss version only)
Environmental
Operating temperature: 0 ~ 60°C (32 ~ 140°F) Storage temperature : -10 ~ 70°C (14 ~ 158°F) Humidity: 5-95% non condensing
Ethernet - DMX8 MkII Range Page 7 of 35
Connectivity
Rear Panel – Side Panel
Mains
Ethernet-DMX8 MkII
The device operates with an AC voltage between 90V and 260V within a frequency range of 47Hz and 63Hz.
An IEC socket is located at the rear of the unit. Please use an IEC plug compliant cable to feed power to the unit. Luminex recommend the use of a power cable, fitted with an IEC-Lock™ plug. The IEC-Lock™ system offers a reliable way to connect the power cable to the unit.
!!! This equipment must be earthed !!!
Punched holes
The unit offers 8 punched holes to easily install 8 optional DMX input connectors, or to reverse the board.
Ethernet
1 Neutrik RJ45 Ethercon is provided as Ethernet link.
Page 8 of 35 Ethernet - DMX8 MkII Range
Punched Holes
10/100Mbps Ethernet ports
IEC Inlet
Powercon socket
DMX connectors
Fuse holder
Ethernet-DMX8 MkII Truss
The device operates with an AC voltage between 100V and 240V within a frequency range of 50Hz and 60Hz.
A Neutrik PowerCon IN connector can be connected to the device. Please use an authorized plug and connect the cores in the mains lead in accordance with the following scheme:
Green / Yellow: Earth
Blue: Neutral
Brown: Live
!!! This equipment must be earthed !!!
Ethernet
1 Neutrik RJ45 Ethercon is provided as Ethernet link.
DMX input / output
8 shielded Neutrik 5 pin gold plated female connectors are provided as outlet (input or output). All DMX outlets are optic and galvanic isolated. See detailed pinout on page 11.
Ethernet - DMX8 MkII Range Page 9 of 35
Interface
Front panel
Ethernet-DMX8 MkII
The front panel interface is provided with 1 graphical LCD display, 1 jog, 1 Ethernet port, 8 DMX outlets and 3 indication LEDs. Standard DMX port routing and advanced features like merging, backup, etc can be configured from the front end LCD display, from the built in Web interface or through LumiNet Monitor V2 Software.
Ethernet port
1 Neutrik RJ45 Ethercon is provided as Ethernet link.
DMX input / output
8 shielded Neutrik 5 pin gold plated female connectors are provided as outlet (input or output). All DMX outlets are optic and galvanic isolated.
Page 10 of 35 Ethernet - DMX8 MkII Range
LED indication of network
activity and link.
Power Ok LED.
10/100MBps Ethernet port
DMX ports: bi-directional Shielded Gold plated XLR 5 pins Neutrik connectors
Graphical LCD Display
And Jog
Connector Function
Pin 1 Signal common (0 volt) Pin 2 Data complement (-) Pin 3 Data true (+) Pin 4 Not used Pin 5 Not used
All outlets are compliant with the DMX512-A timing specification and are terminated and rebiased.
Status indication
3 LEDs are provided to indicate Network link and activity (Ethernet ports 1&2), and power Ok.
Ethernet-DMX8/Truss MkII
Status indication
3 LEDs are provided to indicate Network link and activity (Ethernet ports 1&2), and power Ok.
The front panel interface is provided with 1 graphical LCD display and 1 jog. Standard DMX port routing and advanced features like merging, backup, etc can be configured from the front end LCD display, from the built in Web interface or through LumiNet Monitor V2 Software.
Front end display information
Four indication screens will rotate continuously on the display with an interval of a few seconds.
Ethernet - DMX8 MkII Range Page 11 of 35
Screen 1 – Model and firmware version
This screen informs you on the type of model of Ethernet-DMX8 MkII you're using. It gives also the ID number, and the firmware version the node is actually running.
Screen 2 – Network settings
These two screens display all the information of the two virtual nodes the Ethernet-DMX8 embeds. Each node have a short name entered through the Web interface. The screens give also the complete network setting information, such as IP address and netmask of each node.
Screen 3 – Model and firmware version
This screen gives a complete overview of the DMX ports settings: the second raw gives information on the direction set on each port. The third raw informs you on the mode set on each outlet. Regarding the direction, differents letters will appear to show the mode set on the outlet : N (Normal), H (HTP merge), L (LTP merge), C (Custom), B (Backup), M(Merge), Z (Zero). A “-” means either the outlet is disable, either the outlet is set as an output, but no Art-Net™ data have been detected with the related universe.
See page 16 for the explanation of each available mode.
Page 12 of 35 Ethernet - DMX8 MkII Range
Unlock the node
When the node is password protected through the Web interface, it will automatically lock the access to the Web interface. To unlock the node, enter the password in the password field (login = admin).
Reset the node (Out of jail)
This useful function makes it possible to bring the node in a factory default.
1. Press and hold the jog on the front panel
2. Power up the device
3. wait until the converter to display the reset confirmation
4. confirm
5. The unit is now rebooting to its default settings
Ethernet - DMX8 MkII Range Page 13 of 35
Web interface
Status
The complete device can be configured from an intuitive Web interface. You just have to browse to the IP address of the unit. If you do not know the IP address, you can quickly discover it through the front end display or by running Luminet Monitor V2 software (free downloadable tool), which shows all Luminex nodes on the network.
Make sure that the computer, you use to browse, is setup in the correct network address range (IP 2.x.x.x or 10.x.x.x and subnet 255.0.0.0).
When you're not using a complete network setup (Ethernet switches, hubs, routers, WLAN, ...), you can also use either a cross Ethernet cable or straight Ethernet cable to directly connect the unit to your computer.
After all connections and setup on the computer are completed, open your favorite web browser (we recommend Firefox) and enter the IP address you want to reach in the URL field : Http://2.x.x.x
You'll end up at the status page of the device. This page has a complete overview of the device settings. The overview shows the actual DMX and network setting / routing of the complete device.
The Web interface offers several languages. Select the language that fits your needs in the drop down menu located on the top right side of the Web page.
Page 14 of 35 Ethernet - DMX8 MkII Range
Navigation Bar
Actual DMX routing
Actual Global settings
Actual Network settings
Setup
Choose one of the items in the sub menu to setup the device.
Once in a setup page, help is available on almost every field title. Just click on the question mark next to the topic. A pop up frame will display the overall information of each term displayed on the Web interface.
Node
To setup the node click on the appropriate sub menu item in the Setup navigation bar (Node).
This is the main settings page. You can setup every single outlet of the node, as input or output. Select the outlet's direction, mode, protocol and universe, enable/disable RDM traffic. Here you can also change the IP address, Netmask, port and the Art-Net™ short and long name indication. Node 1 link will lead you to outlets 1 to 4 configuration. Node 2 link will lead you to outlets 5 to 8 configuration page.
Ethernet - DMX8 MkII Range Page 15 of 35
DMX Routing
To better understand the use of all features, let's define each category of this menu:
Direction : Set the direction you need to the outlet, either Input or Output. Depending your selection, some features won't be available in the other categories.
Protocol : Determines the network protocol used for the outlet (Art-Net™ or streaming over ACN (sACN E1.31))
Universe : ArtNet: Select one of 256 possible universes available in the Art-Net™ protocol. This is used for addressing DMX lines on Art-Net™. The hexadecimal value of the universe is in between brackets. The first digit equals to the Art-Net™ subnet and the second to the Art-Net™ universe within that subnet.
sACN : Select the sACN universe to use for addressing DMX lines on sACN. You can enter a numeric value between 1 and 63999. In case of an input, the priority of the universe can be set by adding a colon and the priority value. The priority level can go from 0 to 200. A higher level has a higher priority. (ex: 678:100 means universe 678 at priority level 100)
Mode : According to the direction you set on the outlet, this menu offers several mode :
Input : Disabled : Outlet is disabled, better for node performance.
Normal : Outlet set as normal input
Merge : Allow to merge 2 DMX streams.
When outlet 1 is configured as a merged input, the next outlet (2) will be automatically set as input as well.
Output : Disabled : Outlet is disabled, better for node performance.
Zero : Send all channels with a zero value (for maintenance
only)
Normal: Normal output.
IP Merging : This special feature allows you to merge up to 4 different Art-Net™ or sACN streams through the network. The merging policy will be mainly applied on the Output, except for IP backup.
Legend : Set a legend to the outlet, useful to remind yourself what's connected to that outlet.
Unicast : Art-Net™ is a broadcast protocol, which means that each packet sent from a single source will be received by all actives equipment on the network. Unicast allows you to cast you data to a selected IP address, resulting in a better use of network bandwidth.
Page 16 of 35 Ethernet - DMX8 MkII Range
RDM : Enable / disable RDM. Enabling RDM allows RDM traffic to be transported from/to outlet over the network and back. The nodes will act as an unmanaged proxy device. When set as output it is also possible to enable Adaptive Discovery (AD). AD will continuously check for new and disappeared RDM devices on the output.
Once RDM is activated, you'll notice a cross in the status page. Click on this cross to see the list of discovered RDM devices (Illustration 1) attached to the node.
All setting that are not applicable for the actual setting will be grayed out or marked as N/A (Not Applicable).
Ethernet - DMX8 MkII Range Page 17 of 35
Illustration 1:Discovered RDM devices
Merging Policies :
The Ethernet-DMX8 MkII firmware offers enhanced merging policies that fits to all kind of setup, even the most complex one! 4 available merging policies can be applied on your DMX network, in 2 main setup categories :
Local merging : 2 different DMX streams are merged on the same physical device (Node). The merging policy will be mainly set on Inputs.
IP Merging : This special feature allows you to merge up to 4 different Art­Net™ or sACN streams through the network. The merging policy will be mainly applied on the Output, except for IP backup.
Available policies :
HTP : Highest Take Precedence; Commonly used to merge dimmer
channels. Up to 4 Art-Net™ or sACN sources can be merged.
LTP : Latest Take Precedence; Better suited when using moving lights.
Up to 4 Art-Net™ or sACN sources can be merged.
Backup : Can be used either on input or output. When used on input,
this policy allows you to add a backup DMX console on the second input. When used on a custom output, the policy allows you to add a backup Art-Net™ or sACN source on the network.
Custom : This is the most complete and efficient policy. This mode
offers you to choose what policy to apply for each channel of each universe, and also to create a complete custom soft patch. By more, the merging policy can be remotely triggered by DMX. Up to 2 DMX or Art-Net™ or sACN sources can merged thanks to that policy.
The available policies differs if you use either inputs or outputs :
Page 18 of 35 Ethernet - DMX8 MkII Range
Illustration 2: Local Merging
Inputs (Local mode)
Direction Protocol Universe Mode
Outlet 1 Input ArtNet or
sACN
0(00) Merge
Outlet 2 Input Ch1 HTP, LTP, Backup,
Custom Outlet 3 Input 1(01) Disabled Outlet 4 Input 2(02) Disabled
Left node configuration
In this example (left node of Illustration 2), the selected mode is “Merge”. The second outlet will automatically be set as a merged input. You will not be able to configure a universe address for the second outlet, as the merged result will end at the universe address of the first outlet (primary input). Instead of universe you will be able to set the starting DMX channel address (1-512). This indicates from which channel address the second input has to be merged in. This offset is only available when using HTP or LTP policies. Those rules will be applied on all channel of the whole universe.
If you choose “Backup”, a small blue icon will appears on the left side of “Outlet 2” label; then click on it, a pop up frame appears :
This menu lets you choose the backup time (from 400 to 9999ms). This time represents the delay from which the node will automatically switch to the backup outlet when invalid or no DMX is received anymore on the primary outlet.
Tick the box if you want the node to auto-recover as soon as valid data is available again on primary connector.
If you tick off the box, you will have to enable the trigger universe and select a recover channel (page 27).
If you choose “Custom” policy, a small blue icon will also appear on the left side of “Outlet 2” label; then click on it, a new pop up frame appears :
Ethernet - DMX8 MkII Range Page 19 of 35
Illustration 3: DMX Input backup merging
Click on “Show Table” button to see the complete soft patch available for this outlet.
Offset S1 & S2 : Enter a value for the desired offset of the starting
channel for outlets 1 or 2; example, for channels 1 to start on the third channel, enter 3.
From – To : this range let you quickly set the policy you need on the
channel range of your choice. example, if you need HTP policy on channels 23 to 145, enter 23 in the “From” field and “145” in the “To” field. Then select the HTP policy in the “Mode” drop down list, then press “Set Default Mode”.
Notice that following policies are available for each channel:
Zero, HTP, LTP, S1 only (Source 1 only), S2 only (Source 2 only); S1 as Backup (Source 1 as backup), S2 as Backup (Source 2 as Backup).
The left column represent the resulting universe channel number streamed to the network. S1 column represents Source 1 channels and S2 column Source 2 channels. It's thus easy to understand that you can create your own soft patch by entering the channels of your choice in one of theses column.
Once your patch is created, click submit to close the window, then click submit again on the node page to record your settings.
Page 20 of 35 Ethernet - DMX8 MkII Range
Illustration 4: Custom DMX input merging
Inputs (IP Merging)
Direction Protocol Universe Mode IP
Merging
Outlet 1 Output Artnet or
sACN
1(01) Normal Disabled
Outlet 2 Input Artnet or
sACN
1(01) Normal Backup
Outlet 3 Input 2(02) Disabled Disabled Outlet 3 Input 3(03) Disabled Disabled
Right node configuration
This mode can be very useful in such an application.
The right side lighting desk is used as a backup desk on stage. This means that the right side node will automatically switch to that outlet if no Art­Net™ or sACN packets are available on the selected universe (in that case universe 0). Select your backup time in the small pop up frame by clicking the left blue icon, then submit your changes.
Outputs (IP Merging)
Direction Protocol Universe Mode IP Merging
Outlet 1 Output Normal HTP, LTP,
Custom Outlet 2 Input 1(01) Disabled Disabled Outlet 3 Input 2(02) Disabled Disabled Outlet 4 Input 3(03) Disabled Disabled
This mode can be very useful in the case of 2 control sources located in different places in the network wants to control the same DMX device at the same time.
Ethernet - DMX8 MkII Range Page 21 of 35
Illustration 5: IP Merging
In this setup, the right lighting software (S2) is used in the same time as the left lighting desk (S1). Both streams are merged through the final output on the right node.
The IP Merging mode provides the following policies when an outlet is set as output:
HTP, for all outlet channels. Up to 4 Art-Net™ or sACN sources can be
merged.
LTP, for all outlet channels. Up to 4 Art-Net™ or sACN sources can be
merged.
Custom, to create a complete soft patch, to set merging policy for
every single channel by IP source and to use the enhanced trigger system. Two Art-Net™ or sACN can be merged.
If you choose “Custom”, click on the blue icon left sided to the “Outlet” label. A pop up frame appears:
Page 22 of 35 Ethernet - DMX8 MkII Range
Illustration 6: Output IP merging
You can find in this pop up frame similar features as when using the custom merging on outlets set as inputs (page 19).
The main difference is about the following points :
Ethernet - DMX8 MkII Range Page 23 of 35
Illustration 7: DMX Output custom IP merging
IP Source 1 & 2 : Here you can enter the 2 IP addresses assigned to
your 2 control source. In case you don't know one of your source IP address, simply enter 0.0.0.0 in the address field.
Universe : Here you can select the universes number and the protocol
streamed by your control sources. This feature is very useful if the 2 sources don't use the same universe number or protocol.
Trigger channel. This feature allows you to remotely change the
merging policy of one or several dedicated channels through a single DMX value. From anywhere on the network, you can by example swap from a “LTP” merge to a “S2 only” policy simply by using a different DMX trigger channel value. Enter here the DMX channel you want to use to remotely takeover control of the merging rule. Once you've selected that channel, you'll need to reach the” Global” web page of the node to enable and select your Trigger universe. You'll also need to patch or assign a DMX trigger channel to your control source; here is the DMX chart of the Luminex DMX trigger channel :
0 - 7 Do nothing
8 - 15 Zero out
16 - 23 HTP merge
24 - 31 LTP merge
32 - 39 Source 1 only
40 - 47 Source 2 only
48 - 111 Reserved
112 - 119 Source 1 as backup
120 - 127 Source 2 as backup
128 - 255 Do nothing
Recover channel
If you have set one of a node outlet in IP backup mode, the node will swap automatically to this outlet in case of DMX failure from the primary source. Once the primary source is back again available, the node will automatically swap back to that source if set in Auto-recover mode. We all know that it can be useful to decide when to swap back to the primary source (booting time of the desk + loading the right cue in case of desk failure). Tick off the auto-recover box in the pop up window if you decide to work in manual recover mode. Then you'll have to enable the trigger universe in the “Global” Web page and choose a recover channel. You now have the opportunity to choose to recover either each outlet one by one or all outlet in one shot.
Page 24 of 35 Ethernet - DMX8 MkII Range
Note :Never forget if you control the trigger
channel from more than one source to
press “Do nothing” once you've selected
the desired value. Indeed, if you send
2 different values from 2 different sources
for the trigger channel, the node won't stop
swaping between those values, what results
in a big slowing down of the node processing
power.
Here is the Luminex recover channel DMX chart :
All those soft patches can be recorded or loaded from or to the node by using “Load Patch” or “Export patch” buttons. Luminex node recognize .txt files. These are “TAB” seperated files which can be edited using spreadsheet software (Excel, OO Calc,...)
Ethernet - DMX8 MkII Range Page 25 of 35
Value Outputs Merged Input pairs Normal Inputs
0 – 7 Do nothing Do Nothing Do Nothing
8 – 15 Recover Outlet 1 Recover IP backup Recover IP backup 16 – 23 Recover Outlet 2 Recover DMX Backup Recover IP backup 24 – 31 Recover Outlet 3 Recover IP backup Recover IP backup 32 – 39 Recover Outlet 4 Recover DMX Backup Recover IP backup 40 – 47 Recover Outlet 5 Recover IP backup Recover IP backup 48 – 55 Recover Outlet 6 Recover DMX Backup Recover IP backup 56 – 63 Recover Outlet 7 Recover IP backup Recover IP backup 64 – 71 Recover Outlet 8 Recover DMX Backup Recover IP backup 72 – 79 Recover all outlets Recover All Backup Recover all backup
80 – 255 Do Nothing Do Nothing Do Nothing
Network settings
IP Settings
You can enter here the desired Art-Net™ IP address and Netmask you want to use. If you're not confident with Art-Net™ IP setting, tick the “Art­Net™ compliant?” box for the node to warn you in case of mistake. Art­Net™ IP addresses usually looks like 2.x.x.x or 10.x.x.x.
You're not obliged to work with Art-Net™ IP addresses. If you wish to work with usual IT IP addresses as 192.168.x.x, there's no problem for you to set such address on the node. Please remember that your node will thus not be visible on the network from devices set with conventional Art­Net™ IP addresses (2.x.x.x or 10.x.x.x).
The Port field allows you to change the UDP port used on the network to transmit your UDP Art-Net™ packets. Luminex recommend no to change this value.
Node identification :
Enter here a small and long name to easily identify your node on the network through a Web interface, Art-Net™ compliant softwares or Luminex LumiNet monitor.
Page 26 of 35 Ethernet - DMX8 MkII Range
Global
Some global settings can be altered by clicking Global in the Setup sub menu. Device Settings
Here you can change the device's ID number which is indicated on LumiNet monitor.
You can also enable the Trigger universe to remotely control your merging policy through any DMX source. The node will listen to the specified universe entered in the universe field.
You can set your Recover channel if you use the manual recovery mode (page 19, 24).
DMX details
The DMX frame rate setting for all outlets. This can be set from 20 to 40 frames per second. Break Time can be set from 176 to 352µs.
DMX Output time can be set to 1 – 10 minutes or continuously. This time sets how long an output remains outputting it's last DMX levels after no valid DMX packet came in for that particular universe on Art-Net™ or sACN.
Ethernet - DMX8 MkII Range Page 27 of 35
Miscellaneous
This part is about security and warnings :
Verbose level : Select if you want to see error and warning messages
on the front end LCD or through the Web interface.
Lock Mode: select the security level you want to be applied on your
Ethernet-DMX8 MkII front end. Auto lock will force the Node to lock the jog after 2 minutes of front end inactivity.
Password protected mode will guide you to set a password into the “locking code” field. Once the node is locked, you'll have to enter the 4 digit password through the Web interface password field. Use “admin” in the login field.
Page 28 of 35 Ethernet - DMX8 MkII Range
Toolbox
When clicking on Tools in the navigation bar, a sub menu appears. Choose one of the items in the sub menu.
Profile manager
The profile manager is able to store 40 profiles. All profiles are stored on the device.
A preview of the complete configuration stored in a profile is shown when a profile is selected from the drop down list. When an empty profile is selected, no preview will be shown.
Once a profile is selected you can choose to recall it, to save actual settings as a profile, or to delete the profile.
When recalling a profile, an other page will appear to ask whether to recall your network settings as well or only the outlet routings.
When saving a profile a next page will ask you to fill in a profile name.
Ethernet - DMX8 MkII Range Page 29 of 35
Export profile Download link to save selected profile
Import profile To upload a stored profile from PC or laptop
Snapshot manager
The Ethernet-DMX8 MkII embeds a snapshot function that allows you to capture 3 lighting states (fixed values) per outlet. The snapshot function is only available for outlets set as normal outputs.
Auto load : When this option is ticked and the outlet is set as a normal output, then the unit will automatically load snapshot 1 at startup of the node. As soon Art-Net™ or sACN data arrives for that output, the DMX output will change. This feature is ideal for use in exhibition or expos.
Capture : Captures actual output state as a static DMX snapshot when there is DMX running on the output. Simply press on one of the 3 captures available to snapshot the DMX output.
Execute : Executes clicked snapshot and sets it on the DMX output when configured as a single output. The execute can't work if the associated universes runs on the network.
Edit : Link to edit captured snapshot in a channel table (see following screenshot). Here you can directly edit and change channel values. You can also directly create your lighting state from that windows by inserting desired values, and recall the snapshot from the Web interface.
Page 30 of 35 Ethernet - DMX8 MkII Range
Capture recall
The Ethernet-DMX8 MkII offers a user friendly interface for users to easily recall the recorded snapshots from the Web interface. Type the following address to reach the execute buttons page, where w.x.y.z represents the Ethernet-DMX8 MkII IP address : http://w.x.y.z/cgi-bin/toolbox_outlet.cgi/
For instance:
http://2.212.104.190/cgi-bin/toolboox_outlet.cgi/
Ethernet - DMX8 MkII Range Page 31 of 35
Firmware upgrade
The firmware upgrade page allows you to select a downloaded firmware file and upload it to the device.
This page shows the actual firmware version running on the unit below the file upload field.
The latest firmware file can always be downloaded from the Luminex web pages.
Http://www.luminex.be
To install the firmware on the Ethernet-DMX8 MkII follow these steps:
1. Download the .zip file and save it on your hard disk.
2. Extract the .zip file.
3. Please read the "ChangeNote.txt" for latest release changes.
4. Browse to the device its IP address with your favorite web browser.
5. Click Toolbox -> Firmware upgrade.
6. Br owse to the ext rac ted upg rad e file on your hard disk (ethdmx8mkii_v4.X.X.bin), where X.X represents firmware version.
7. Select the file and press on the "Upgrade" button.
8. The upgrade file will be sent to the device. The following message appears on the front end display:
Page 32 of 35 Ethernet - DMX8 MkII Range
9. The unit will then reboot after the upgrade procedure and will display the following message on front end display:
10.Wait until the device has rebooted. (until then the Power/Ok LED will be blinking). A solid Power/Ok LED on indicates your Ethernet­DMX8 MkII has been properly updated.
11.Click now on Toolbox -> Firmware upgrade if the current version is set to the right version number. If the number is the same as mentioned with the file then the upgrade succeeded.
Ethernet - DMX8 MkII Range Page 33 of 35
Toubleshooting
The Power/OK LED is always blinking:
You're Ethernet-DMX8 MkII doesn't boot properly. Restart the unit with the power switch. If this doesn't help, contact your local dealer. Please note the Power/OK LED will be blinking during upgrade procedure, don't switch off the power during this step.
My computer is connected to the node, but the Link/Activity
LED is still off.
Check the Ethernet cable you're using, and check that each RJ45 on each side of the cable is properly inserted. Feel free to plug another cable to isolate the problem.
I can't reach the Web interface of the Ethernet-DMX8 MkII
Please check first the two previous steps. Then please be sure your computer is set in the same IP range than your Ethernet-DMX8 MkII. Try to ping the unit with a dedicated application, such as a DOS session on Windows, or a terminal session on MAC. You can use LumiNet Monitor V2 to discover your Ethernet-DMX8 MkII. If you can't see your device in LumiNet Monitor V2, please contact your local dealer.
Page 34 of 35 Ethernet - DMX8 MkII Range
Additional Documentation
All additional documentation can be downloaded from our web pages in the support section.
Http://www.luminex.be
--> Support
Credits:
Art-Net™ is a trade mark of Alderamin Group Ltd. The Art-Net protocol and associated documentation is copyright Alderamin Group Ltd.
Ethernet - DMX8 MkII Range Page 35 of 35
Loading...