Luminex DMX2 Truss Mkii, DMX2 Mkii User Manual

Ethernet - DMX2 MkII Range
User Guide - V4.x.x
Ethernet - DMX2 MkII Range User Guide - V4.x.x
Document lu_01_00032_2_man
Copyright © 2003-2012 . All rights reserved.
No part of this documentation may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying and recording, without the prior written permission of Luminex.
Issued by:
Publications Department, Luminex LCE, Berkenlaan 8A, Hechtel - Eksel, B-3940, Belgium. Documentation reviewed January 20, 2012, by Bart Swinnen. Printed in the EU.
Table of Contents
Warranty information........................................................................ 5
Limited warranty..........................................................................5
Returning under warranty..............................................................5
Freight........................................................................................ 5
General.......................................................................................... 6
Packaging.................................................................................... 6
Description.................................................................................. 6
Specification................................................................................ 6
Dimensions...............................................................................6
Weight..................................................................................... 7
Electrical.................................................................................. 7
Connectors............................................................................... 7
Environmental........................................................................... 7
Connectivity.................................................................................... 8
Rear Panel – Side Panel.................................................................8
Mains.......................................................................................8
Interface....................................................................................... 10
Front panel................................................................................ 10
Ethernet port..........................................................................10
DMX input / output..................................................................10
Status indication...................................................................10
Unlock the node......................................................................11
Reset the node (Out of jail)....................................................... 11
Web interface................................................................................ 12
Status....................................................................................... 12
Setup........................................................................................ 13
Node...................................................................................... 13
DMX Routing........................................................................... 14
Merging Policies :.....................................................................16
Inputs (Local mode).............................................................. 17
Inputs (IP Merging)...............................................................19
Outputs (IP Merging)............................................................19
Recover channel................................................................... 22
Patch files :.........................................................................22
Network settings..................................................................23
IP Settings..........................................................................23
Global.................................................................................... 24
DMX details......................................................................... 24
Miscellaneous....................................................................... 24
Toolbox...................................................................................... 25
Profile manager....................................................................... 25
Snapshot manager................................................................... 26
Firmware upgrade.................................................................... 29
Troubleshooting....................................................................... 30
Additional Documentation................................................................ 31
Credits:..................................................................................... 31

Warranty information

Limited warranty

Unless otherwise stated, your product is covered by a two (2) years parts and labor limited warranty. It is the owner’s responsibility to furnish receipts or invoices for verification of purchase, date, and dealer or distributor. If purchase date cannot be provided, date of manufacture will be used to determine warranty period.

Returning under warranty

Any Product unit or parts returned to Luminex LCE must be packaged in a suitable manner to ensure the protection of such Product unit or parts, and such package shall be clearly and prominently marked to indicate that the package contains returned Product units or parts. Accompany all returned Product units or parts with a written explanation of the alleged problem or malfunction.

Freight

All shipping will be paid by the purchaser. Items under warranty shall have return shipping paid by the manufacturer only in the European Union. Under no circumstances will freight collect shipments be accepted. Prepaid shipping does not include rush expediting such as air freight. Air freight can be sent customer collect in the European Union.
Warranty is void if the product is misused, damaged, modified in any way, or for unauthorized repairs or parts.
Ethernet - DMX2 MkII Range Page 5 of 31

General

Packaging

- Ethernet-DMX2 Rack MkII
1 x Ethernet – DMX2 MkII Rack
1 x User guide
- Ethernet-DMX2 Truss MkII
1 x Ethernet – DMX2 Truss MkII
1 x Powercon male connector
1 x User Guide

Description

The Ethernet - DMX2 MkII is an Ethernet node that serves 2 x DMX512 outlets, compatible with the following protocols: DMX512, DMX512-A, RDM (ANSI E1.20), sACN (ANSI E1.31) and Art-Net™.
All 2 outlets are conform to DMX512-A and can be used as input or output. The Ethernet link is a 100BaseT connection on a Neutrik RJ45 Ethercon connector, located on the front end.
All configuration can be done over Ethernet through a built in website.
This all comes in a 19'' unit high metal housing for the Ethernet-DMX2 MkII). The Ethernet-DMX2 Truss MkII comes in a rugged truss mountable metal housing with a M10 insert. This enclosure allows to use the node in a truss or as a table top device. The device provides also four punched holes at the rear, allowing the user to fix the converter on a wall. Please remove the 4 plastic caps to get access to these holes.

Specification

Model: Ethernet–DMX2 MkII Rack – Ethernet-DMX2 Truss MkII Manufacturer: LUMINEX Lighting Control Equipment

Dimensions

Ethernet-DMX2 MkII
482 x 153.5 x 44 (mm) 19” x 6,04” x 1,73” Package: 520 x 235 x 50 (mm)
Ethernet-DMX2 Truss MkII
190 x 119.5 x 66 (mm) 7,48” x 4,7” x 2,6” Package: 305 x 215 x 110 (mm)
Page 6 of 31 Ethernet - DMX2 MkII Range

Weight

Ethernet-DMX2 MkII: 2 Kg Ethernet-DMX2 Truss MkII: 1.6Kg

Electrical

Voltages: 90 – 260 VAC Frequency: 47 – 63 Hz Rated power: Rack version : 20 W, Truss version: 4 W Fuse : Rack version :125V – 250V, 1A, Slow blow only (5mm x 20mm) Truss version : 125V – 250V, 3.15A, Slow blow only (5mm x 20mm) Power Over Ethernet supply as option, reference: LU 01 00046

Connectors

1 x shielded Neutrik RJ45 Ethercon connector on the front 1 x shielded Neutrik RJ45 Ethercon connector on the side (truss version only) 2 x shielded Neutrik gold plated 5 pin XLR (female) 2 x optic and galvanic isolated DMX port 1 x IEC inlet with fuse holder (rack version only) 1 x Neutrik Powercon inlet (truss version only)

Environmental

Operating temperature: 0 ~ 60°C (32 ~ 140°F) Storage temperature : -10 ~ 70°C (14 ~ 158°F) Humidity: 5-95% non condensing
Ethernet - DMX2 MkII Range Page 7 of 31

Connectivity

Rear Panel – Side Panel

Mains

The device operates with an AC voltage between 90V and 260V within a frequency range of 47Hz and 63Hz.
Ethernet-DMX2 Rack MkII
An IEC socket is located at the rear of the unit. Please use an IEC plug compliant cable to feed power to the unit. Luminex recommend the use of a power cable, fitted with an IEC-Lock™ plug. The IEC-Lock™ system offers a reliable way to connect the power cable to the unit. The equipment must be earthed !
Page 8 of 31 Ethernet - DMX2 MkII Range
Powercon IN
10/100MBps Ethernet port
Ethernet-DMX2 MkII Truss
The device operates with an AC voltage between 90V and 260V within a frequency range of 47Hz and 63Hz.
A Neutrik PowerCon IN connector can be connected to the device. Please use an authorized plug and connect the cores in the mains lead in accordance with the following scheme:
Green / Yellow: Earth
Blue: Neutral
Brown: Live
!!! This equipment must be earthed !!!
Ethernet
1 Neutrik RJ45 Ethercon is provided as Ethernet link. This Ethernet port can be used to power up the unit through PoE (Power over Ethernet). You'll need to install the optional Luminex PoE module to power up the unit (LU 01 00046).
Ethernet - DMX2 MkII Range Page 9 of 31

Interface

Front panel

The front panel interface is provided with 1 Ethernet port, 2 DMX outlets and 2 indication LEDs. Standard DMX port routing and advanced features like merging, backup, etc has to be configured from the built in web interface .

Ethernet port

1 Neutrik RJ45 Ethercon is provided as Ethernet link.

DMX input / output

2 shielded Neutrik 5 pin gold plated female connectors are provided as outlet (input or output). All DMX outlets are optic and galvanic isolated.
Connector Function
Pin 1 Signal common (0 volt) Pin 2 Data complement (-) Pin 3 Data true (+) Pin 4 Not used Pin 5 Not used
All outlets are compliant with the DMX512-A timing specification and are terminated and rebiased.
Status indication
2 LEDs are provided to indicate Network link and activity, and power Ok.
Page 10 of 31 Ethernet - DMX2 MkII Range
LED indication of network activity and link. Power Ok LED.
10/100MBps Ethernet ports
DMX ports: bi-directional shielded Gold plated XLR 5 pins Neutrik connectors