As Navico is continuously improving this product, we retain the
right to make changes to the product at any time which may not be
reflected in this version of the manual. Please contact your nearest
distributor if you require any further assistance.
It is the owner’s sole responsibility to install and use the instrument
and transducers in a manner that will not cause accidents, personal
injury or property damage. The user of this product is solely
responsible for observing safe boating practices.
NAVICO HOLDING AS AND ITS SUBSIDIARIES, BRANCHES AND
AFFILIATES DISCLAIM ALL LIABILITY FOR ANY USE OF THIS PRODUCT
IN A WAY THAT MAY CAUSE ACCIDENTS, DAMAGE OR THAT MAY
VIOLATE THE LAW.
Governing Language: This statement, any instruction manuals,
user guides and other information relating to the product
(Documentation) may be translated to, or has been translated from,
another language (Translation). In the event of any conflict between
any Translation of the Documentation, the English language
version of the Documentation will be the official version of the
Documentation.
This manual represents the product as at the time of printing.
Navico Holding AS and its subsidiaries, branches and affiliates
reserve the right to make changes to specifications without notice.
Warning: It is your sole responsibility
to install and use the instrument and
transducer(s) in a manner that will not
cause accidents, personal injury or
property damage. Always observe safe
boating practices.
Compliance Statements
Structure ScanTM HD complies with the
following regulations:
• CE compliant under EMC Directive.
• C - Tick compliant as level 2 device.
Structure ScanTM HD also meets the
technical standards in accordance with
Part 15.103 of the FCC rules.
Warning
The user is cautioned that any changes
or modifications not expressly approved
by the party responsible for compliance
could void the user’s authority to operate
the equipment.
This equipment has been tested and
found to comply with the limits for a Class
B digital device, pursuant to Part 15 of
the FCC rules. These limits are designed
to provide reasonable protection against
harmful interference in a residential
installation. This equipment generates,
uses and can radiate radio frequency
energy and, if not installed and used in
accordance with the instructions, may
cause harmful interference to radio
communications. However, there is no
guarantee that the interference will
not occur in a particular installation.
If this equipment does cause harmful
interference to radio or television
reception, which can be determined
by turning the equipment off and on,
the user is encouraged to try to correct
the interference by one or more of the
following measures:
Reorient or relocate the receiving antenna
Increase the separation between the
equipment and receiver
Connect the equipment into an outlet on
a circuit different from that of the receiver
Consult the dealer or an experienced
technician for help.
Compliance | StructureScan HD Installation
| 3
Contents
2 Disclaimer
5 Introduction
5 Parts included in package
6 Required tools and supplies
6 StructureScan HD Indicator lights
7 Installation and Wiring
7 Selecting mounting location
8 Mounting the StructureScan HD module
8 Wiring
11 Specications
11 Technical specifications
12 Spare parts and accessories
12 Spare parts
12 Assessories
13 Drawings
13 StructureScan HD module dimensions
4 |
Contents | StructureScan HD Installation
1
Introduction
This document describes how to install the StructureScan™ HD
black box module and connect the unit to transducers and display
units.
Separate installation instruction for transducers are included with
the transducer package.
Parts included with your StructureScan HD
For spare parts and part numbers, see Parts list page 12.
ItemNo.Description
1StructureScan HD Black box module
14 pin power cable
1Fuse, 3A Automotive Type
1Fuse holder
2Yellow Ethernet caps
1Close end crimp connector
4Phillips stainless steal screws (#8)
1Warranty
1This manual
1Manual translations DVD
Introduction | StructureScan HD Installation
| 5
LINK/ACT
123
SONAR
POWER
Required tools and supplies
2 mm
Drill
(5/64”)
Drill Bit
Phillips screw
driverPencil
StructureScan HD Indicator lights
Ind.StatusDescription
No Ethernet communication
1, 2 and 3
Sonar
Power
Off
Flashing -
yellow
Off
On - Green
Flashing -
green
Off
On - RedSystem booting
On - GreenSystem operating
Slow ashing -
Red/green
Fast ashing -
Red/green
(cable unplugged, bad cable or
remote unit not powered)
Ethernet communication is
working (link/active light)
Transducer not connected or
cable/transducer is broken
Transducer detected/locked on to
bottom
Transducer detected/not locked
on to bottom
No power or not switched on
(check yellow wire)
Product in factory mode; Ethernet
communication working
Product in factory mode; no
Ethernet communication (cable
unplugged or bad cable)
6 |
Introduction | StructureScan HD Installation
2
Installation and Wiring
The StructureScan HD black box module connects between the
transducer and display unit, or via a network switch.
Before installing the module, consider location and cable runs necessary to connect the module to the display unit and power source.
Do not run the transducer cabling near the module DC power
cables or any VHF antenna coax or power cables for the VHF.
The module conforms to the appropriate Electromagnetic Compatibility (EMC) standards; but proper installation is required to get the
best use and performance from this product.
Selecting mounting location
When installing the module certain factors that could affect its operation should be considered. Ensure you have as much separation
as possible between different electrical equipment, (see diagram).
Make sure the transducer cable is long enough to connect to the
module. If not, an extension cable is available (only one extension
is recommended for optimal performance). For transducer cable
length see
Installation and Wiring | StructureScan HD Installation
Spare parts and accessories, page12.
2.0 m (6.5 ft) Min
Compass
1.8 m (6 ft) Min
| 7
Mounting the StructureScan HD module
Preferably mount the StructureScan HD black box module on a
vertical surface so that cables exit sideways. If that is not feasable,
create drip loops to prevent moisture entering the connectors.
HD
HD
Fasten the module by using the screws included with the unit.
Secure cables and ensure to not put strain in the connectors.
Wiring
Refer to the Wiring diagram on page 10.
Warning: Removing the transducer cable from the
StructureScan HD module while it is powered on can cause
sparks. Remove the transducer cable only after the module
has been disconnected from its power source.
8 |
Connecting the module to your display
The module connects to your display over an Ethernet network,
either directly or via an Ethernet network switch.
Installation and Wiring | StructureScan HD Installation
Connecting the transducer
The StructureScan transducer connects to the module with
the cable supplied with the transducer.
On boats with large dead rise angle two StructureScan transducers can be used. They are connected to the module by
using the optional Y cable. Connect the transducers accord-
ing to the labeling on the Y-cable.
LTWLTW
LTW
Power connection
The unit will turn on when power is applied.
It is recommended to connect the module to a Power control bus
(A), and set your unit to power control master.
Alternatively the unit can be powered directly from the vessel’s bat-
tery (B).
Power
Control
bus
(1)
(3)
Fuse
_
+
12 V DC
(4)
(2)
(no connect)
BA
Pin/ItemColorSignal
1Black12 V battery -
124
3
2BlueNC
3Red12V battery +
4YellowIgnition sense
Installation and Wiring | StructureScan HD Installation
(1)
(3)
(4)
Switch
(2)
(no connect)
_
+
12 V DC
| 9
¼ Note: If the black box module is connected directly to the vessel’s
battery, the module will continue to draw power even when it is not
in operation. It is recommended that the yellow power cable wire
be fitted with an optional on/off switch, allowing the module to be
powered off when not in use.