![](/html/15/1595/15954c1592bb4cfb453e0d852787ee6773b220e936b666f781819764d0e3755b/bg1.png)
Dimensions
204 mm (8.03")
169 mm (6.63")
NET-3NET-1POWER
NET-2
12V/24V 3A
91 mm
(3.58")
57 mm (2.24")
207 mm
180 mm
(7.09")
(8.15")
SonarHub
Installation Guide
For technical speciļ¬cations, certiļ¬cates and
declarations, refer to the product web site
on:
lowrance.com
simrad-yachting.com
TRANSDUCER1 TRANSDUCER2
183 mm (7.20")
1
ID DESCRIPTION
3
000-11142-001
SonarHub only
5
000-11141-001
SonarHub w/
LSS HD XDCR
000-11300-001
6
SonarHub w/
TM150 XDCR
7
000-11301-001
SonarHub w/
LSS TM150 and
LSS HD XDCRs
10
000-11304-001
SonarHub w/
SPOTLIGHT
XDCR
1 SonarHub module 1 1 1 1 1
2 SonarHub installation screws 4 4 4 4 4
3 Ethernet cable, 4 m (15 ft) 1 1 1 1 1
4 Power cable, 2 m (6.6 ft) 1 1 1 1 1
5 Fuse and Fuse holder 1 1 1 1 1
6 LSS StructureScan HD XDCR 1 1
7 TM150 CHIRP XDCR 1 1
8 SPOTLIGHT Heading sensor 1
9 Trolling Motor clamp 1
10 SPOTLIGHT XDCR 1
*988-10539-001*
MountingParts included
12V/24V 3A
TRANSDUCER1 TRANSDUCER2
NET-3NET-1POWER
NET-2
12V/24V 3A
NET-3NET-1POWER
NET-2
TRANSDUCER1 TRANSDUCER2
NET-3NET-1POWER
NET-2
TRANSDUCER1 TRANSDUCER2
12V/24V 3A
NET-3NET-1POWER
TRANSDUCER1 TRANSDUCER2
12V/24V 3A
NET-2
![](/html/15/1595/15954c1592bb4cfb453e0d852787ee6773b220e936b666f781819764d0e3755b/bg2.png)
Power
Power controlled by External Switch Power controlled by Multi-Function Display
To Multi-Function
Display
Black
Black
Yellow
Blue
(n/c)
_
NET-3NET-1POWER
NET-2
TRANSDUCER1 TRANSDUCER2
_
+
12 / 24 V DC
Switch
Black
Yellow
Blue
(n/c)
Red
NET-3NET-1POWER
NET-2
TRANSDUCER1 TRANSDUCER2
Red
Yellow Red
Blue
(n/c)
Power
Control bus
+
12 / 24 V DC
12V/24V 3A
Wiring examples
MULTI-FUNCTION DISPLAYS
4G RADAR
WIFI-1
12V/24V 3A
NET-3NET-1POWER
Views on the MFD:
CHIRP
1
12V/24V 3A
or
SONARHUB
StructureScan plus single
frequency 83 kHz
2
CHIRP
and
StructureScan
TM150 LSS HD
NET-2
12/24 V DC
TRANSDUCER1 TRANSDUCER2
1 2
Connectors and LEDs
1
2
NET-3NET-1POWER
TRANSDUCER1 TRANSDUCER2
12V/24V 3A
NET-2
3 4
ID CONNECTORS LEDs
1 Ethernet
OFF No connection
ON/FLASHING - Green Connected and ok
OFF No power
2 Power
ON - Red System starting
ON - Green System operating
FLASHING Red/Green Software error - restart unit
OFF Sounder not operating
CHIRP / Broadband
3
transducer
FLASHING (every second) - Green Searching for bottom signal
ON
Structure Scan HD
transducer,
4
Spotlight
transducer
OFF Sounder not operating
FLASHING (every second) - Green Searching for bottom signal
ON
Operational system with
bottom signal detected
Operational system with
bottom signal detected
4G RADAR
SPOTLIGHT
HEADING SENSOR
NMEA 2000 NETWORK
12 V DC
HDS NON-TOUCH
MULTI-FUNCTION DISPLAYS
SONARHUB
TT
NET-3NET-1POWER
NET-2
TRANSDUCER1 TRANSDUCER2
12V/24V 3A
SPOTLIGHT
TRANSDUCER
12/24 V DC