Lowe Perfect Skin User Manual

Page 1
INDEX
INFORMATION ABOUT THIS MANUAL TERMS AND CONDITIONS OF WARRANTY SAFETY WARNINGS CONTRA-INDICATIONS DESCRIPTION OF THE DEVICE AND ACCESSORIES
SIGNALLING FEATURES DEVICE CHARGE USE
OPERATION TEST
FACE TREATMENT
BODY TREATMENT
CREAM TREATMENT ( CREAM CONVEYANC E) MAINTENANCE PROBLEMS AND SOLUTIONS TECHNICAL FEATURES DISPOSAL OF THE DEVICE DISCLAIMER LABELS CONTACTS DECLARATION OF CONFORMITY
Page 2
INFORMATION ABOUT THIS MANUAL
LOWE srl is proud to present PERFECT SKIN, an anti-aging sof t devic e aime d at trea ting t he most frequent face an d bo dy im perfections and conveyin g active principles into the skin.
LOWE srl thanks you for purchasing PERFECT SKIN device and wish you a pleasant use.
ATTENTION! Instructions and warnings for safe use
Before using the device, read carefully the instructions for use and safety notes
following ca u tiously th e in s tructions. Failure, even partial, of the recommendations contained in it may generate malfunction
and/or damage to the device and void the warranty. Keep this manual for the entire lifetime of the device for consultation. Contact LOWE S.r.l.
in case this m a nual is difficult to understand or in case of loss.
TERMS AND CONDITIONS OF WARRANTY
LOWE warrants this product to its customers (pursua nt to the Article 128, co. 2, lett. a) of the Italian legislative decree 6.09.2005, nr. 206, Consumer Code) for the period of two (2) years from the date of purchase.
To exercise your warranty rights you will hav e to sh ow a p ur c has e doc ume nt, attest i ng th e date of purchase, the product description, model and serial number. In case you bought it from a retailer, you will have to show a docume nt indicating their name, address and VAT.
LOWE srl also ensures the availability of spare parts for ten (10) years from the date of purchase (quality warranty).
When a problem occurs and if it is com mu nicate d wit hi n t he warranty period, LOWE srl will, at its discretion, replac e th e pro duct for free.
LOWE srl wa rrants the devi c e only when used in accordance with the instructions provided in this manual. The warranty does not cover failures due to improper maintenance, tampering, use of non original accessories, wear, fall or break of fragile parts, unauthorized opening of casings, not adequate placement or installation, modification, alteration or repair by anyone not authorized by LOWE srl, purchase documents and/or serial numbers unreadable or tamper ed.
Should it be necessary to return the product, use the original packaging enclosing a purchase document that certifies the date of the product purchase and a document indicating the occurred problem. Before shipping the product make sure you have consulted the manual section "Problems and solutions".
Page 3
Remember that the staff of LOWE srl Customer Service will always be available to an swer your questions and provide help. For more information, please visit the dedicated section on the website or consult the Contacts section of this manual.
SAFETY WARNINGS
After removing the device from the packaging, check the integrity of the content and the presence of any transport damage. If in doubt, do not turn on the device and call the LOWE Customer Servic e.
Keep out of reach of children: the device is not a toy. Children or people cannot use this device with reduced mental or sensory capacity.
People with reduced physica l ability or with lac k of exp erien ce and k nowl edge can use it if they are properly monitored, if they were instructed (by referring to this manual) about the safety use of the device, or if they understand the related dangers.
This device must be used only for the purpose for which it was designed that is as laser device for personal us e t o perform aesthetic treatment s on t h e face and body.
Before connecting the device, check that the data of the voltage on the rating plate of the charger and in the "Technical features" of this manual correspond to those of the mains electricity available.
Do not use the device during the charging process or once it is ended, if the device is not yet disconnected from the mains electricity.
Do not pull the power cable or the unit to remove the plug from the voltage adapter or from the power outlet.
If the power cable or the power plug of voltage adapter are damaged, LOWE Customer Service must replace th em , in order to avoid any risks.
Do not use a different charger from the one provided. Always unplug the electr ic al power cable before clean ing and m aintenance. Before connecting or disconnecting the power cable of the charger from the device
connector, make sure you have previously unplugged from the power out l et. Do not use the dev ice c lose t o water or ot her li quid s ources . Nev er imme rse th e devi ce in
liquids. Never use the device in pres ence of anesthetic and inflammable substances. Do not expose the device to humidity, to the influence of weather conditions (such as
rain, sun), to chemical products and vibrations. Use, charge and store the device observing the following environmental characteristics:
room temperature +10˚C to +40˚C, humidity from 10% to 80% without condensation.
Page 4
In case of failure or malfunction of the device, turn it off and do not tamper it. For any repairs please contact only LOWE Customer Service.
Do not use the device in the internal parts of the body. Do not point the device towards the eyes. Always avoid eye exposure to direct or
scattered laser beam r adi at ion and led. Do not unscrew the device since inside there are electronic components that can be
damaged. Only LOWE srl trained personnel can open the device. The battery replacement operation must be carried out only and exclusively by LOWE srl
trained personnel.
CONTRA-INDICATIONS
Do not use the device in case of: pregnancy, neoplasia 8in progress), on the thyroid area, immuno-suppressive therapy, decompensated diabetes and therapies with vasoconstrictors drugs.
Do not use the device in presence of photosensitivity reactions (often due to the intake of known drugs) because the side effects of the combination of theese drugs with the infrarred laser and the red l ight leds are not clear enough.
Do not use the laser if you have a pacemaker. Pacemakers are a contra-indication to the use of laser.
Means of fixation, metal and plastics plates are not a contraindication to the use of the laser.
During the treatment with PERFECT SKIN it is recommended not to wear any jewel, dress or accessory that may be reflective on the treatment or adjacent areas.
DESCRIPTION OF THE DEVICE AND ACCESSORIES
PERFECT SKIN is a soft laser for personal usage for aesthetic treatments for the face and body.
The energy emitted both from the LED red beam and the infrared beam of laser diodes plays an action of biostimulation and tissue regeneration that represents an effective solution for skin imperfections and also a vehicle effect of some substances into the body.
The LED treatment ensures a natural biostimulation, directly removing the damages caused by aging through the emission of a monochromatic light without thermal effect. This mechanism stimulates the cell metabolism, inducing derma and sub-dermis to increase the production of collagen and elastin.
The infrared laser stimulates the general mechanisms involved in the tissue regeneration. It has positive influence on the stimulation of fibroblasts for the production of new type I collagen and elastin, as well as enzymatic photoactivation effects that provoke an improvement of the metabolic processes and of cell "respiration" thanks to the
Page 5
vasodilation effect that provides the skin with a higher quantity of blood and therefore nutrients.
The combination of red LED with infrared Laser diodes (which are invisible to human eye) provokes the opening of skin channel able to conveying active principles (such as vitamins and hyaluronic acid) to skin, maximizing its result and combining it with the beneficial effects of th e t w o t echn ologies indicated above.
The package contains:
- PERFECT SKIN device
- charger with USB cable
- black cloth case
- user manual
- protective goggles for FACE treatment
WARNINGS AND CONTROLS
1. Lens to focus the soft laser
2. Red-colored guide li gh t fo r th e indication of the operating device
3. Laser diode
4. Sensor for the verification of the laser emission 5. Socket for the connection of the charger cable
CONTROLS PANEL
6. Button for turning on and off and for the selection of treatment mode
7. Red led light signaling th e cur rent /standby laser emission an d t h e charging battery
8. Green led light for the Fa ce mo d e
9. Green led light for the Body mode
10. Green led light for the Cre am m o d e
11. Socket for the connection of the charger cable
SIGNALLING FEATURES
6
7
9
8
11
10
Page 6
PERFECT SKIN has 4 led indicators on the Control panel (n. 7, 8, 9,10) with the following features:
Led light n.7
Fixed red light during the laser emission Flashing red light for standby lase r emission or charging battery
Led light n. 8 FACE Fixed green light in case o f Fac e treatment Flashing green to indicate low batt ery
Led light n. 9 BODY Fixed green light in case o f Bo dy t reatm en t Flashing green to indicate low batt ery
Led light n. 10 CREAM (CREAM CONVETANCE) Fixed green light during t he Cream treatment Flashing green to indicate low batt ery
The LED indicators n. 8, n. 9 and n.10 simultaneously flash when the charging process is finished.
DEVICE CHARGE
The battery charger supplied with the device complies with the safety directive of
information technology equipment EN60950-1.
We recommend that you do not use other battery chargers than the one supplied. The use of any different battery charger might damage the device and invalidate the warranty. Once connected the battery charger to the device, before plugging it to mains or to a computer, check that the device has not been damaged during transportation and make sure that the characteristics of the power supply on mains comply with the characteristics indicated on the bottom of the devic e.
Before using PERFECT SKIN for the first time, charge the batteries by following the following indications:
1. Insert the battery charger connector to the plug at the bottom of the device
2. Plug the battery charger to mains or to a computer through USB port
3. The red led turns on: this indicates that the charging process in pr ogress. Ful l charging will take about 3 hours
4. To indicate the end of the charging process, all the green le d lights start blinking
5. Unplug the battery charger from mains or the computer.
6. Disconnect the battery charger connector from the device, which is now ready to be used.
Page 7
When the device is out of power, one of the three green led lights starts blinking. The led turns off after the charg ing process has started. If PERFECT S KIN is connecte d to mains whe n is still turned on, it will tu rn off automatically.
USE
OPERATION TEST
Whenever you want to use PERFECT SKIN, you have to verify it works correctly by carrying out the following test.
1. To test the device, place it with the lens down and in contact with any part of the body, except for the eyes, for example with hands or legs (the photodiode enables the infrared laser beam and the pointing red led at a distance shorter than 3 cm from any surface or part).
2. Tur n on the device by holding the power button pressed for few seconds. The red led will blink and the FACE green led will turn on by default .
3. The red led is blinking (laser emission in standby mode). Place a hand at a distance shorter than 3 cm from the device’s lens (it is better there is a contact), thus the red led will emit a fixed light (laser emission in progress).
4. If the operation test has be en successful, you can proceed w ith the desired treatment.
When the device is turned on, it will be in FACE mode by default. If you prefer to go to the BODY mode hold the power button pressed until the green led of the desired program will turn on. If you prefer to go to the CREAM mode hold again the power button pressed until the green led of the desired program will turn on. To go back to the FACE treatment hold again the button pressed by turning off the device and continuing pressing it until it will turn on.
FACE TREATMENT
- To obtain a drainage effect and provide the skin with a bright appearance;
- To remove wrinkles and obtain a face anti-agin g effect.
The FACE treatment must be performed on clean, dry and without make-up face skin. Please remove any jewel or dress that may be reflective to the area to be treated or to the adjacent area. Open the box containing the PERFECT SKIN LASER, remove the device case and press the power button until the green light led of the FACE program will turn on by making sure to never direct the lens, and thus the Laser beam and the LED, toward the eyes. Before performing this program we suggest to wear the supplied protective goggles. Put the device lens in contact with face skin by keeping it as much perpendicular as possible. The treatment is performed by treating the hemiface (half face) at a time, it must start from the lower part of the face, preferably, the chin, and then slowly you must move to the upper part (forehead). It is important to treat the whole half part of the face trying to distribute the LED and infrared Laser energy homogeneously to the entire surface. Each
Page 8
time the infrared Laser emission and the red led are activated the device will emi t a short acoustic signal. The movements with PERFECT SKIN must be slow holding the device perpendicular to the treating area so as to allow the Laser and LED to transfer the necessary energy to the skin for the anti-aging treatment, by focusing on the areas mainly affected by imperfections (wrinkles). The treatment duration for the hemiface is 15 minutes. At the end of the time, the device will emit a triple acoustic signal before automatically turning off, which indicates the end of the program for the treated hemiface. Once ended the treatment, turn on again the device, as indicated in this procedure, set it for the FACE program and perform the treatment on the other hemiface. Perform the same movements by focusing on the ar eas mainly affected b y imperfections (wrinkles) until the triple acoustic signal of the device, which indicates the end of the treatment on the hemifac e an d th e en d o f t he first FACE treatment. Repeat the treatment fo r at le ast 3-4 times per week.
BODY TREATMENT
- To improve skin imperfections caused by cellulite (PEFS);
- To improve the state of stretch marks and obtain a drainage effect.
The BODY treatment must be performed on clean, dry and without cream body skin. Please remove any jewel or dress that may be reflective to the area to be treated or to the adjacent area. Open the box containing the PERFECT SKIN LASER, remove the device case and press the power button until the green light led of the BODY program will turn on by making sure to never direct the lens, and thus the Laser beam and the LED, toward the eyes. Put the device lens in contact with body skin by keeping it as much perpendicular as possible. The treatment is performed by treating one area of the body (for example the right thigh) at a time and it must start form the l ower par t of it moving i t slowing to w ard the upper par t. It is important to treat the whole area of the body trying to dis tribute the red LED and infrared Laser energy homogeneously to the entire surface. Each time the infrared Laser emission and the red led are activated the device will emit a short acoustic signal. The movements with PERFECT SKIN must be slow holding the device perpendicular to the treating area so as to allow the Laser and LED to transfer the necessary energy to the skin for the treatment of imperfections, by focusing on the mainly affected areas (cellulite and stretch marks). The treatment duration is 20 minutes. At the end of this time, the device will emit a tripe acoustic signal before automatically turning off. Once ended the treatment on the selected area of the body, turn on again the device, as indicated in this procedure, set it for the BODY program and perform the treatment on the other side.
Page 9
Perform the same movements by focusing on the ar eas mainly affected by imperfections (cellulite and stretch marks) until the triple acoustic signal and the automatic turning off of the device, which indicate s t he en d o f t he BODY treatment. Repeat the treatment fo r at le ast 3-4 times per week.
CREAM TREATMENT (CREAM CONVEYANCE)
To convey active principles like vitamins, hyaluronic acid and specif creams into the skin.
The CREAM treatment (CREAM CONVEYANCE) must be performed on body or face skin, which must be clean, dry, and without make-up or creams that are not proper for the conveyance. Please remove any jewel or dress that may be reflective to the area to be treated or to the adjacent area. Open the package containing the PERFECT SKIN and remove the device case. Distribute a slight layer of cream to be conveyed on the part of the hemiface or body. In the case of hemiface we suggest to always wear the protective goggles supplied with the device. Keep the power button pressed until the green light led of the CREAM program (CREAM CONVEYANCE) turns on; be careful to never point the lens, and therefore the laser beam and LED, toward the eyes. Put the device lens in contact with face or body skin by keeping it as much perpendicular as possible. The treatment is performed by treating one area of the hemiface (half face) or of the body (for example the right thigh) at a time. It must start form the lower part of it moving it slowing toward the upper part: it is important to treat the whole area of the face or body trying to distribute the red LED and infrared Laser energy homogeneously to the entire surface. Each time the infrared Laser emission and the red led are activated the device will emit a short acoustic signal. The movements with PERFECT SKIN must be slow holding the device perpendicular to the treating area so as to allow the Laser and LED to transfer the necessary energy to the skin. This is necessary in order to open the channels that will allow the cream conveying or the active principles (vitamins or hyaluronic acid) to be conveyed into the face or body skin, by focusing on the mainly affected areas (wrinkles, cellulite and stretch marks). The treatment duration is 15 minutes. At the end of this time, the device will emit a triple acoustic signal before automatically turning off. Once ended the treatment on the selected area of the body, turn on again the device, as indicated in this procedure, distribute a slight layer of the cream to be conveyed and set it again for the CREAM program (CREAM CONVEYANCE) performing the treatment on the other side. Perform the same movements by focusing on the ar eas mainly affected by imperfec tions
Page 10
(wrinkles, cellulite and stretch marks) until the triple acoustic signal and the automatic turning off of the device, which indicates the end of the CREAM treatment (CREAM CONVEYANCE). If at the end of each treatment the cream or lotion applied to the face or body skin has not completely been conveyed we suggest to apply a lesser quantity of product for the next treatment and to let the skin absorb the remaining cream or l otion with a manual massage. Repeat the treatment fo r at le ast 2-3 times per week.
Note: To obtain the maximum beneficial effect use creams/active principles suggested by LOWE srl.
• KIEMÉ treatment ANTI-AGE FACE
• KIEMÉ treatment ANTI-AGE FACE and NECK
• KIEMÉ Treatment BODY * For more information on the treatment protocol connect to our website www.lo-we.com
PERFECT SKIN always warn the user about the activation of the emission by means of an acoustic sign al.
At the end of the treatment the laser emission stops and the device emits a triple warning acoustic signal. Press the Program button so as to turn off the device and not unnecessarily dischar ge battery.
MAINTENANCE
For safety reasons, before carrying out any maintenance or cleaning operations, it is necessary to turn off the device if it is operating and to disconnect it from the battery charger or from the computer, if it is connected or in charge. The external cleaning of PERFECT SKIN device must be performed only with a moist soft cloth or by using a non-inflammable liquid detergent. While cleaning it, be careful not to wet the control console where the connection of the battery charger is located.
Do not use solvents, detergents, acid solutions, aggressive solutions or inflammable liquids.
After cleaning the body and lens of PERFECT SKIN, perfectly dry all its parts before operating it again.
PROBLEMS AND SOLUTIONS
If the device does not work, make sure that the battery is not low. To charge it correctly, refer to the chapter “Device charge” of this manual. Furthermore, check that the device is not turned off by holding the power button pressed for few seconds. If these operations
Page 11
do not solve the problem, please contact LOWE Customer Service (refer to the section “Contacts” in this manual).
TECHNICAL FEATURES
PERFECT SKIN
Power
Type
With rechargeable
built-in battery
Technical data
(100 ÷ 240) V
(50 ÷ 60) Hz
Characteristics of
battery
Type
Lithium battery
Capacity
1100 mAh
Supply voltage
3.7 V
Size
48x30x7 mm
Weight
19.5 gr
Characteristics of the
body
Material
ABS
Shape
Rigid cylindr ical tube
Size
Diameter 37mm
Height 157mm
Color
PANTONE 386 (yellow / lime green)
Characteristics of
the base
Material
ABS
Shape
Rigid cylindr ical tube
Size
Diameter 37mm
Height 25mm
Superficial treatment Nickel- planting
Characteristics of
lens
Material
Methacrylate (PMMA)
Shape
Flat
Size
Diameter 37mm
Height 38mm
Superficial treatment Polished
Available treatments
Face
Page 12
Body
Cream
Treatment duration
Face
15 minutes
Body
20 minutes
Cream
15 minutes
Treatment frequency
Face
5 kHz
Body
8 kHz
Cream
2.5 kHz
Pulse duration
100 ns
Laser diode emission wave le ngth
905 nm
Number of laser diodes
2
LED diode emis sion wave length
625 nm
Number of LED
3
Laser classi fication accor ding to EN 60825-1
3 B
N° of applicat ions for each charge
4
Optical density
at a distance from
1.23 to 0.5 m
at a distance
between 0.70 to 1 m
Peak power for single diode
25 W
Average power per laser diode
25 mW
LED diode light intensity
30 mcd
Led to indicating IR radiation
on the contr ol panel
Type of laser emission signal
Signaling de vice w ith
2 red light led.
Battery
charger
model
FW7710/E
U/0.7
Average charge time 2,5 h
Input voltage
100-230 Vac
Output voltage
5.0Vdc 700mA
External dimensions (diame ter x height)
Ø37 x H205 mm
Packaging d imensions (width x height x depth)
300 x 50 x 105 mm
Weight of the device
183.5 gr
Page 13
DISPOSAL OF THE DEVICE
PERFECT SKIN is designed to h ave m inimal negative impact on the environment.
The device should be not treated as household waste, but it should rather be brought to the appropriate collection point for recycling of electrical and electronic equipment.
DISCLAIMER The users of the device use it at their own risk. LOWE srl does not assume any responsibility
or liability for the use of this product. LOWE srl reserves the right to change the contents of this manual without obligation to notify the revisions.
LABELS
Attention, laser beam
Dispose of the device as electronic waste
Carefully read the user m an ual
Marking of the device
Rated voltage
Nominal voltage
=
Direct current
Max current Input
Max input current
Rated power
Nominal power
Model
Commercial model of the device
Visible and invisible laser radiation. Avoid exposition to laser
beam. Laser device of cla ss 3B
Peak Power: Maximum po wer emitted by the device Wavelength: Wavelength
Page 14
Pulse duration: P ulse duration
CONTACTS
LOWE S.r.l.
Via degli Abeti 92, 61122 Pesaro
Ph 0721.404772 Fax 0721.1633123
For assistance: customercare@lo.we.com
For general information: info@lo-we.com
www.lo-we.com
Page 15
DECLARATION OF CONFORMITY
Loading...