Loctite B1613401 User Manual

Safety Data Sheet
Revision Number: 002.0
Issue date: 04/24/2015
IDH number: 1772707
Product name: Loctite Super Glue
1. PRODUCT AND COMPANY IDENTIFICATION
Product name:
Loctite Super Glue
IDH number:
1772707
Product type:
Cyanoacrylate
Restriction of Use:
None identified
Region:
United States
Company address:
Contact information:
Henkel Corporation One Henkel Way Rocky Hill, Connecticut 06067
Telephone: +1 (800) 624-7767 MEDICAL EMERGENCY Phone: Poison Control Center 1-877-671­4608 (toll free) or 1-303-592-1711 TRANSPORT EMERGENCY Phone: CHEMTREC 1-800-424-9300 (toll free) or 1-703-527-3887
2. HAZARDS IDENTIFICATION
EMERGENCY OVERVIEW
WARNING:
BONDS SKIN IN SECONDS. COMBUSTIBLE LIQUID. CAUSES EYE IRRITATION. MAY CAUSE RESPIRATORY IRRITATION.
HAZARD CLASS
HAZARD CATEGORY
FLAMMABLE LIQUID
4
EYE IRRITATION
2B
SPECIFIC TARGET ORGAN TOXICITY - SINGLE EXPOSURE
3
PICTOGRAM(S)
Precautionary Statements
Prevention:
Keep away from heat, sparks, open flames, hot surfaces - no smoking. Avoid breathing vapors, mist, or spray. Wash thoroughly after handling. Use only outdoors or in a well-ventilated area. Wear protective gloves, eye protection, and face protection.
Response:
IF INHALED: Remove person to fresh air and keep comfortable for breathing. IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to remove. Continue rinsing. Call a poison control center or physician if you feel unwell. If eye irritation persists: Get medical attention. In case of fire: Use foam, dry chemical or carbon dioxide to extinguish.
Storage:
Store in a well-ventilated place. Keep container tightly closed. Store in a well-ventilated place. Keep cool. Store locked up.
Disposal:
Dispose of contents and/or container according to Federal, State/Provincial and local governmental regulations.
Classification complies with OSHA Hazard Communication Standard (29 CFR 1910.1200) and is consistent with the provisions of the United Nations Globally Harmonized System of Classification and Labeling of Chemicals (GHS).
See Section 11 for additional toxicological information.
3. COMPOSITION / INFORMATION ON INGREDIENTS
Page 1 of 6
IDH number: 1772707
Product name: Loctite Super Glue
Hazardous Component(s)
CAS Number
Percentage*
Ethyl 2-cyanoacrylate
7085-85-0
60 - 100
Glyceryl ester
Proprietary
10 - 30
Thickener
Proprietary
1 - 5
* Exact percentage is a trade secret. Concentration range is provided to assist users in providing appropriate protections.
4. FIRST AID MEASURES
Inhalation:
Move to fresh air. If breathing is difficult, give oxygen. If not breathing, give artificial respiration. If symptoms develop and persist, get medical attention.
Skin contact:
Do not pull bonded skin apart. Soak in warm soapy water. Gently peel apart using a blunt instrument. If skin is burned due to the rapid generation of heat by a large drop, seek medical attention. If lips are bonded, apply warm water to the lips and encourage wetting and pressure from saliva in mouth. Peel or roll lips apart. Do not pull lips apart with direct opposing force.
Eye contact:
Immediately flush with plenty of water for at least 15 minutes. Get medical attention. If eyelids are bonded closed, release eyelashes with warm water by covering with a wet pad. Do not force eye open. Cyanoacrylate will bond to eye protein and will cause a lachrymatory effect which will help to debond the adhesive. Keep eye covered until debonding is complete, usually within 1-3 days. Medical attention should be sought in case solid particles of polymerized cyanoacrylate trapped behind the eyelid caused abrasive damage.
Ingestion:
Ensure breathing passages are not obstructed. The product will polymerize rapidly and bond to the mouth making it almost impossible to swallow. Saliva will separate any solidified product in several hours. Prevent the patient from swallowing any separated mass.
Symptoms:
See Section 11.
Notes to physician:
Surgery is not necessary to separate accidentally bonded tissues. Experience has shown that bonded tissues are best treated by passive, non-surgical first aid. If rapid curing has caused thermal burns they should be treated symptomatically after adhesive is removed.
5. FIRE FIGHTING MEASURES
Extinguishing media:
Foam, dry chemical or carbon dioxide.
Special firefighting procedures:
Wear a self-contained breathing apparatus with a full face piece operated in pressure-demand or other positive pressure mode.
Unusual fire or explosion hazards:
None
Hazardous combustion products:
Trace amounts of toxic and/or irritating fumes may be released and the use of breathing apparatus is recommended.
6. ACCIDENTAL RELEASE MEASURES
Use personal protection recommended in Section 8, isolate the hazard area and deny entry to unnecessary and unprotected personnel.
Environmental precautions:
Ventilate area. Do not allow product to enter sewer or waterways.
Page 2 of 6
Loading...
+ 4 hidden pages