Lochinvar PVL 07575, PVN 07575, CVN075075, CVL075075 Installation And Operating Manual

Installation and Operating Manual
POWER VENTED GAS WATER HEATERS
NOT FOR USE IN MANUFACTURED (MOBILE) HOMES
300 Maddox Simpson Parkway
Lebanon, TN 37090
Phone: 615-889-8900 • Fax: 615-547-1000
Technical Services email: 2tech@lochinvar.com
www.lochinvar.com
POWER VENTED GAS MODELS
WITH HOT SURFACE IGNITION
MODELS PVN/PVL 07575 and
CVN075075/CVL075075 SERIES 210/211
WARNING: If the information in these instruc­tions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.
- Do not store or use gasoline or other flam­mable vapors and liquids in the vicinity of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas sup­plier's instructions.
• If you cannot reach your gas supplier, call
the fire department.
- Installation and service must be performed by a qualified installer, service agency or the gas supplier.
WARNING
Read and understand instruction manual and safety messages before installing, operating or servicing this water heater.
Failure to follow instructions and safety messages could result in death or serious injury.
Instruction manual must remain with water heater.
For Your Safety
AN ODORANT IS ADDED TO THE GAS USED
BY THIS WATER HEATER.
ALL TECHNICAL AND WARRANTY QUESTIONS: SHOULD BE DIRECTED TO THE LOCAL DEALER FROM WHOM THE WATER HEATER WAS PURCHASED. IF YOU ARE UNSUCCESSFUL, PLEASE CONTACT THE COMPANY LISTED ON THE RATING PLATE ON THE WATER HEATER.
KEEP THIS MANUAL IN THE POCKET ON HEATER FOR FUTURE REFERENCE
WHENEVER MAINTENANCE ADJUSTMENT OR SERVICE IS REQUIRED.
1808 100221773_2000189439_Rev. 01
TABLE OF CONTENTS
Safe Installation, Use And Service . . . . . . . . . . . . . . . . 3
General Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Qualified Installer Or Service Agency . . . . . . . . . . . . 6
Preparing For The Installation. . . . . . . . . . . . . . . . . . 6
Installation Requirements For The
Commonwealth Of Massachusetts. . . . . . . . . . . . . . . . 7
Typical Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Get To Know Your Water Heater - Gas Models
(List Referencing Figures 1-7). . . . . . . . . . . . . . . . . . 9
Replacement Parts And Deliming Products . . . . . . 10
Combo Heating Inlet And Outlet Side Taps . . . . . . . 10
Water Piping - Mixing Valve Usage . . . . . . . . . . . . . .11
Mixing Valves
Water Heater Operation . . . . . . . . . . . . . . . . . . . . . 12
Electrical Requirements & Wiring Diagram . . . . . . . 13
Safety Lockouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
High Limit Controls (Energy Cut Off). . . . . . . . . . . . 14
Thermostat/Water Temperature Blower High Limit Switch
Blower Air Pressure Switch. . . . . . . . . . . . . . . . . . . 14
Flammable Vapor Sensor . . . . . . . . . . . . . . . . . . . . 14
Locating The New Water Heater . . . . . . . . . . . . . . . . 15
Facts To Consider About The Location . . . . . . . . . . 15
Storage Of Flammable Liquids . . . . . . . . . . . . . . . . 15
Clearances to combustibles Floors with carpeting Clearance for servicing
Insulation jackets and Blankets. . . . . . . . . . . . . . . . 17
Air Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Unconfined Space. . . . . . . . . . . . . . . . . . . . . . . . . . 17
Unusually Tight Construction . . . . . . . . . . . . . . . . . 17
Confined Space. . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Direct Vent Appliances . . . . . . . . . . . . . . . . . . . . . . 18
Exhaust Fans . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Fresh Air Openings For Confined Spaces. . . . . . . . 18
Chemical Vapor Corrosion . . . . . . . . . . . . . . . . . . . 19
Installing The New Water Heater . . . . . . . . . . . . . . . . 20
Water Piping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Space Heating And Potable Water Systems . . . . . . 20
Combo Heating . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
System Requirements Installation
Closed Water Systems . . . . . . . . . . . . . . . . . . . . . . 22
Recirculation Loops. . . . . . . . . . . . . . . . . . . . . . . . . 22
Thermal Expansion . . . . . . . . . . . . . . . . . . . . . . . . . 22
Temperature-Pressure Relief Valve. . . . . . . . . . . . . 23
T&P valve discharge pipe requirements: Temperature-Pressure Relief Valve and Pipe
Insulation
High Altitude Installation . . . . . . . . . . . . . . . . . . . . . 24
Gas Piping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Sediment Traps. . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Filling The Water Heater . . . . . . . . . . . . . . . . . . . . . 26
Venting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Termination Clearances Sidewall Power Vent. . . . . 27
Blower Assembly Installation. . . . . . . . . . . . . . . . . . 28
Installation Of Vent System. . . . . . . . . . . . . . . . . . . 28
Planning The Vent System . . . . . . . . . . . . . . . . . . . 28
Polypropylene Vent Systems . . . . . . . . . . . . . . . . . 29
Condensate. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Exhaust Venting . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Important Notes and Warnings Venting terminations and sizing Vent screen installation Calculating Equivalent Feet Venting instructions Vent pipe connection to blower Coupling installations according to vent sizes
Blower Exhaust Direction . . . . . . . . . . . . . . . . . . . . 34
Vent Pipe Preparation . . . . . . . . . . . . . . . . . . . . . . . 34
Installation Checklist . . . . . . . . . . . . . . . . . . . . . . . . 37
Lighting Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Operating The Temperature Control System . . . . . . . 39
Gas Control Valve/Thermostat (160°) . . . . . . . . . . . 40
Gas Control Valve/Thermostat (181°) . . . . . . . . . . . 40
For Your Information. . . . . . . . . . . . . . . . . . . . . . . . . . 41
Start Up Conditions . . . . . . . . . . . . . . . . . . . . . . . . . 41
Condensate Smoke/Odor Strange sounds
Operational Conditions . . . . . . . . . . . . . . . . . . . . . . 41
Smelly water
“Air” In Hot-Water Faucets . . . . . . . . . . . . . . . . . . . 41
Periodic Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . 42
General Upkeep . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Venting System Inspection . . . . . . . . . . . . . . . . . .
Blower Maintenance . . . . . . . . . . . . . . . . . . . . . . . . 42
Cleaning The Blower. . . . . . . . . . . . . . . . . . . . . . . . 42
Burner Operation And Inspection . . . . . . . . . . . . . . 43
Combustion Chamber And Burner Cleaning. . . . . . 44
Housekeeping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Anode Rod Maintenance. . . . . . . . . . . . . . . . . . . . . 44
Temperature-Pressure Relief Valve Test . . . . . . . . . 45
Draining And Flushing. . . . . . . . . . . . . . . . . . . . . . . 46
To Drain The Water Heater Storage Tank To Flush The Water Heater Storage Tank
Leakage Checkpoints. . . . . . . . . . . . . . . . . . . . . . . . . 47
Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Reference Parts Listing . . . . . . . . . . . . . . . . . . . . . . . 48
Troubleshooting Guidelines . . . . . . . . . . . . . . . . . . . . 50
Resetting The Heater Control . . . . . . . . . . . . . . . . . 52
Lockouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Soft Lockout Hard Lockout
Ignition State And Timing . . . . . . . . . . . . . . . . . . . . 53
System Status And Error Codes . . . . . . . . . . . . . . . 53
Reading The LED Flash Sequence. . . . . . . . . . . . . 54
. 42
2 www. lochinvar .com 100221773_2000189439_Rev. 01
SAFE INSTALLATION, USE AND SERVICE
Your safety and the safety of others is extremely important in the installation, use and servicing of this water heater. Many safety-related messages and instructions have been provided in this manual and on your own water heater to warn you and others of a potential injury hazard. Read and obey all safety messages and instructions throughout this manual. It is very
important that the meaning of each safety message is understood by you and others who install, use or service this water heater.
This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.
DANGER indicates an imminently
DANGER
WARNING
CAUTION
CAUTION
hazardous situation which, if not avoided, will result in death or injury.
WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or injury.
CAUTION indicates a potentially hazardous situation which, if not avoided, could result in minor or moderate injury.
CAUTION used without the safety alert symbol indicates a potentially hazardous situation which, if not avoided, could result in property damage
All safety messages will generally tell you about the type of hazard, what can happen if you do not follow the safety message and how to avoid the risk of injury.
This product is certified to comply with a maximum weighted average of 0.25% lead content as required in some areas.
IMPORTANT DEFINITIONS
Qualified Installer: A qualified installer must have ability equivalent to a licensed tradesman in the fields of plumbing, air supply, venting and gas supply, including a thorough understanding of the requirements of the ”National Fuel Gas Code” as it relates to the installation of gas fired water heaters. The qualified installer must also be familiar with the design features and use of flammable vapor ignition resistant water heaters and have a thorough understanding of this Installation and Operating manual.
Service Agency: A service agency also must have ability equivalent to a licensed tradesman in the fields of plumbing, air supply, venting and gas supply, including a thorough understanding of the requirements of the ”National Fuel Gas Code” as it relates to the installation of gas fired water heaters. The service agency must also have a thorough understanding of this Installation and Operating manual, and be able to perform repairs strictly in accordance with the service guidelines provided by the manufacturer.
Gas Supplier: The Natural Gas or Propane Utility or service who supplies gas for utilization by the gas burning appliances within this application. The gas supplier typically has responsibility for the inspection and code approval of gas piping up to and including the Natural Gas meter or Propane storage tank of a building. Many gas suppliers also offer service and inspection of appliances within the building.
100221773_2000189439_Rev. 01 www. lochinvar .com 3
GENERAL SAFETY
Read and understand instruction manual and safety messages before installing, operating or servicing this water heater.
Failure to follow instructions and safety messages could result in death or serious injury.
Instruction manual must remain with water heater.
DANGER
WARNING
Water temperature over 125°F can cause severe burns instantly resulting in severe injury or death.
Children, the elderly and the disabled and are at highest risk of scald injury.
Feel water before bathing or showering.
WARNING
Fire Hazard
For continued protection against risk of fire:
Do not install water heater on carpeted floor.
Do not operate water heater if flood damaged.
WARNING
Explosion Hazard
Overheated water can cause
water tank explosion.
Properly sized temperature and
pressure relief valve must be installed in opening provided.
HOT
HOT
BURN
Temperature limiting valves are available.
Read instruction manual for safe temperature setting.
WARNING
Fire or Explosion Hazard
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other appliance.
Avoid all ignition sources if you smell gas.
Do not expose water heater control to excessive
gas pressure.
Use only gas shown on rating plate.
Maintain required clearances to combustibles.
Keep ignition sources away from faucets after
extended period of non-use.
Read instruction manual before
installing, using or servicing
water heater.
4 www. lochinvar .com 100221773_2000189439_Rev. 01
GENERAL SAFETY
CAUTION
Improper Installation, use and service may result
in property damage.
Do not operate water heater if flood damaged.
Inspect anode rods regularly, replace when significantly
depleted.
Install in location with drainage.
Fill tank with water before operation.
Properly sized thermal expansion tanks are required on all
closed water systems.
Refer to this manual for installation and service.
WARNING
Breathing Hazard - Carbon Monoxide Gas
• Install vent system in accordance with codes.
• Do not operate water heater if flood damaged.
• For operation above 10,100’, a high altitude orifice must be installed.
• Do not operate if soot buildup is present.
• Do not obstruct water heater air intake with insulating jacket or blanket.
• Do not obstruct blower air intake.
• Do not place chemical vapor emitting products near water heater.
• Gas and carbon monoxide detectors are available.
• No vent damper installation is compatible with this power vented water heater.
Breathing carbon monoxide can cause brain damage or death.
Always read and understand instruction manual.
WARNING
• Before servicing the water heater, make sure the blower assembly is unplugged or the electrical supply to the water heater is tumed "OFF".
• Label all wires prior to disconnection when servicing controls. Wiring error can cause improper and dangerous opera­tion. Verify proper operation after servicing.
• Failure to do this could result in death, serious bodily injury, or property damage.
WARNING
FLAMMABLES
FIRE AND EXPLOSION HAZARD
Can result in serious injury or death
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. Storage or use of gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance can result in serious injury or death.
Flammable Vapors
100221773_2000189439_Rev. 01 www. lochinvar .com 5
INTRODUCTION
Thank You for purchasing this water heater. Properly
installed and maintained, it should give you years of trouble free service.
Abbreviations found in this Installation and Operating manual:
CSA - Canadian Standards Association
ANSI - American National Standards Institute
NFPA - National Fire Protection Association
ASME - American Society of Mechanical Engineers
UL - Underwriters Laboratories Inc.
AHRI - Air Conditioning, Heating and Refrigeration
Institute.
This gas-fired water heater is design certified by CSA International as a Category IV vented heater, under Water Heater Standard ANSI Z21.10.3 • CSA 4.3 (current edition).
QUALIFIED INSTALLER OR SERVICE AGENCY
Installation and service of this water heater requires ability equivalent to that of a Qualified Agency (as defined by ANSI below) in the field involved. Installation skills such as plumbing, air supply, venting, gas supply and electrical supply are required in addition to electrical testing skills when performing service.
ANSI Z223.1 2006 Sec. 3.3.83: “Qualified Agency” - “Any individual, firm, corporation or company that either in person or through a representative is engaged in and is responsible for (a) the installation, testing or replacement of gas piping or (b) the connection, installation, testing, repair or servicing of appliances and equipment; that is experienced in such work; that is familiar with all precautions required and that has complied with all the requirements of the authority having jurisdiction.”
If you are not qualified (as defined by ANSI above) and licensed or certified as required by authority having jurisdiction to perform a given task, do not attempt to perform any of the procedures described in this manual. If you do not understand the instructions given in this manual do not attempt to perform any procedures outlined in this manual.
PREPARING FOR THE INSTALLATION
1. Read the “General Safety” section of this manual first and then entire manual carefully. If you don’t follow safety rules, the water heater will not operate properly. It could cause DEATH, SERIOUS BODILY INJURY AND/OR PROPERTY DAMAGE. This manual contains instructions for installation, operation, and maintenance of the gas-fired water heater. It also contains warnings throughout the manual that you must read and be aware of. All warnings and instructions are essential to proper operation of the
water heater and your safety. Since we cannot put everything on the first few pages, READ ENTIRE MANUAL BEFORE ATTEMPTING TO INSTALL OR OPERATE THE WATER HEATER.
2. The installation must conform with these instructions and local code authority having jurisdiction. In absence of local codes, installation must comply with current editions of the “National Fuel Gas Code”, ANSI
Z223.1/NFPA 54 and “National Electrical Code”, NFPA 70. All documents are available from:
CSA International, 8501 East Pleasant Valley Road, Cleveland, Ohio, United States 44131-5575.
NFPA documents are also available from: National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02269.
3. The water heater, when installed, must be electrically grounded in accordance with the local codes or in the absence of local codes: current edition of the “National Electrical Code”, NFPA 70.
4. If after reading this manual you have any questions or do not understand any portion of the instructions, call the local gas utility or the manufacturer whose name appears on the rating plate.
5. Carefully plan the place where you are going to put the water heater. Correct air supply for combustion and blower operation, vent action, and vent pipe installation are very important in preventing death from possible carbon monoxide poisoning and fires (see Figure 15 & Figure 16). Examine the location to ensure the water heater complies with the “Locating The New Water Heater” section in this manual.
6. For installation in areas subject to earthquakes, this water heater must be braced, anchored, or strapped to avoid falling or moving during an earthquake. See instructions for correct installation procedures. Instructions may be obtained from:
California Office of the State Architect, 400 P Street, Sacramento, CA 95814.
7. Massachusetts Code requires this water heater to be installed In accordance with Massachusetts 248-CMR
2.00: State Plumbing Code and 248-CMR 5.00.
8. Complies with California Health and Safety code 116875 (known as AB-1953) and with weighted average maximum of 0.25% lead.
6 www. lochinvar .com 100221773_2000189439_Rev. 01
INSTALLATION REQUIREMENTS FOR THE COMMONWEALTH OF MASSACHUSETTS
COMMONWEALTH OF MASSACHUSETTS For all side wall terminated, horizontally vented power vent, direct vent and power direct vent gas fueled water heaters installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied:
INSTALLATION OF CARBON MONOXIDE DETECTORS At the time of installation of the side wall horizontal vented gas fueled equipment, the installing plumber or gasfitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gasfitter shall observe that a battery operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure served by the sidewall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors. In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level. In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of thirty (30) days to comply with the above requirements provided that during said thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall be installed. APPROVED CARBON MONOXIDE DETECTORS
Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI/ UL 2034 listed and CSA certified.
SIGNAGE A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The sign shall read, in print size no less than one- half (1/2) inch in size, “GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS.”
INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.08(2)(a) 1 through 4.
EXEMPTIONS The following equipment is exempt from 248 CMR 5.08(2) (a) 1 through 4:
1. The equipment listed in Chapter 10 entitled “Equipment Not Required To Be Vented” in the most current edition of NFPA 54 as adopted by the Board; and
2. Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling, building, or structure used in whole or in part for residential purposes.
MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM PROVIDED When the manufacturer of Product Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the instructions provided by the manufacturer for installation of the equipment and the venting system shall include:
1. Detailed instructions for the installation of the venting system design or the venting system components; and
2. A complete parts list for the venting system design or venting system.
MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED When the manufacturer of Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases, but identifies “special venting systems,” the following requirements shall be satisfied by the manufacturer:
1. The referenced “special venting system” instructions shall be included with the appliance or equipment installation instructions; and
2. The “special venting systems” shall be Product Approved by the Board, and the instructions for that system shall include a parts list and detailed installation instructions.
A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation.
100221773_2000189439_Rev. 01 www. lochinvar .com 7
INSTALLATION GRAPHIC: GAS-FIRED POTABLE WATER HEATING/SPACE HEATING SYSTEM
• If your water heater will be installed in the Commonwealth of Massachusetts, refer to the following
graphic during installation and during modifications to the water supply system.
COMBINATION SPACE HEATING / POTABLE WATER HEATING SYSTEM
TEMPERED WATER TO FIXTURES (MUST MEET TEMPS LISTED IN MASS. CODE 248 CMR
MUST BE VERTICAL TO REMOVE A
MIXING VALVE (MUST BE INSTALLED BELOW TOP OF WATER HEATER AS PER MANUFACTURER’S RECOMMENDATIONS)
WATER HEATER ACCEPTED BY THE BOARD FOR INSTALLATION IN MASSACHUSETTS.
MASSACHUSETTS INSTALLATION REQUIREMENTS:
*
1.) CONNECT ELECTRONICALLY-CONTROLLED TIMER TO AN ALL-BRONZE PUMP. PUMP MUST ACTIVATE EVERY 6 HOURS
2.) ALL WATER PIPING MUST BE INSTALLED AND INSULATED IN ACCORDANCE WITH MASSACHUSETTS CODE (248 CMR
3.) PIPING LOOP BETWEEN WATER HEATER AND AIR HANDLER MUST BE INSTALLED IN COMPLIANCE WITH 248 CMR.
† REQUIRED FOR MASSACHUSETTS.
‡ PIPING FROM THE TOP OF THE WATER HEATER WITH TEES IS ACCEPTABLE.
IR BUBBLES
FOR 60 SECONDS. TURN PUMP TIMER OFF BEFORE CLOSING PIPING LOOP SHUT-OFF VALVE.
& 780 CMR).
)
TYPICAL MIXING VALVE INSTALLATION
EXPANSION TANK
CHECK
VALVE
UNION
HOT
WATER
OUT
VACUUM
RELIEF VALVE
UNION
TEMP/ PRESSURE RELIEF VALV E
SEE NOTE ‡
100’-0” MAXIMUM DISTANCE FROM WATER HEATER TO FAN COIL AND BACK. (DEVELOPED LENGTH) NOT INCLUDING COIL
CHECK VALVE
(1/8” HOLE
DRILLED IN CLAPPER)
PUMP
TO
AIR
HANDLER
SHUT-OFF
VALV E
*
IN HEATING UNIT
COLD WATER INLET
FLOW CONTROL
VA
LV
E
*
OUT
COIL
AIR
HANDLER
SHUT-OFF
VALVE
IN
8 www. lochinvar .com 100221773_2000189439_Rev. 01
TYPICAL INSTALLATION
GET TO KNOW YOUR WATER HEATER - GAS MODELS (LIST REFERENCING FIGURES 1-7)
1 Vent Termination Elbow with Rodent
Screen 2 *Vent Pipe 3 *Vent Pipe Coupling (if required) 4 CPVC Vent Pipe ( 5 ft. supplied) 5 *CPVC Vent Pipe Elbow (long
radius) 6 Gear Clamp (see Figure 6) 7 T&P Valve 8 **Combo Heating System Supply
Outlet (Optional) 9 Cold-Water Inlet Nipple/Diptube 10 * Discharge Pipe 11 Gas Control Valve/Thermostat
(Honeywell) 12 Gas Valve Electronic Control Module
And Cover (Honeywell) 13 **Combo Heating System Return
Inlet (Optional) 14 ***Control Harness 15 Drain Valve 16 Outer Gas Door
17 Manifold Door Assembly
(behind outer door) (see
Figure 3 (NG) or Figure 4 (LP)) 18 *Floor Drain 19 *Metal Drain Pan 20 Flammable Vapor Sensor (under
cover) (see Figure 5) 21 Flexible Manifold Tube (see
Figure 3) 22 *Sediment Trap 23 *Ground Joint Union (gas
connection) 24 *Main Manual Gas Shut-off Valve 25 *Gas Supply* 26 Baffle Assembly 27 Rating Plate 28 Blower with Power Cord (see
Figure 6) 29 *Rubber Coupling (see Figure 6) 30 *Inlet Water Shut-off Valve 31 *Union (water connection) 32 Hot-Water Outlet Nipple 33 Anode (under cap) 34 Air Inlet Snorkel 35 Flue Collector
36 *Thermal Expansion Tank (required
for all closed systems) 37 Aluminum Burner (see Figure 3) 38 Gas Orifice (see Figure 3) 39 Gas Manifold (see Figure 3) 40 Hot-Surface Igniter (see Figure 3) 41 Manifold Door Gasket (see
Figure 3) 42 Manifold Door (see Figure 3) 43 Two Piece Grommet With Clip (see
Figure 3) 44 Viewport (see Figure 3) 45 Flame Sensor Rod (see Figure 3) 46 Stainless Steel Burner (see
Figure 4) 47 Air Switch (inside box) (see
Figure 6) 48 Air Tubing (see Figure 6) 49 Blower High Limit Switch (see
Figure 6) 50 Junction Box Cover (see Figure 6) 51 Junction Box (see Figure 6) *, **, ***, **** see notes on following
page
1 2
27
25
24
23
22
29
28
28
26
6
4
3
5
30
6
7
8
36
31
35
31
32
33
10
9
11
12
9
Blower
Dilution Air
Inlets
Combustion
Air Inlets
13
34
14
15
21
20
19
100221773_2000189439_Rev. 01 www. lochinvar .com 9
Front View
Figure 1.
16
18
17
Rear View
Figure 2.
Natural gas main burner with igniter assembly
(item 17 in Figure 1).
37
Flare
21
Nut
45
38
39
51
50
4847
29
6
49
28
44
43
Figure 3.
Propane (LP) main burner with igniter assembly
(item 17 in Figure 1).
46
Flare
21
Nut
44
43
Figure 4.
45
42
42
40
41
38
39
40
41
Figure 6.
Vacuum relief valve install per local codes (not supplied with heater).
Figure 7.
Notes:
* Items not supplied with the water heater. ** The side recirculation loop connections may not be
used as the primary water inlet and outlet connections.
See “Combo Heating Inlet And Outlet Side Taps”. *** Caution: harness has 120 VAC In operation. **** See “Planning The Vent System”, “Condensate” and
“Blower Assembly Installation” for more information.
REPLACEMENT PARTS AND DELIMING PRODUCTS
Replacement parts and recommended delimer may be ordered through authorized servicers or distributors. When ordering parts, provide complete model and serial numbers (see rating plate), quantity and name of part desired. Standard hardware items may be purchased locally.
20
Figure 5.
10 www. lochinvar .com 100221773_2000189439_Rev. 01
COMBO HEATING INLET AND OUTLET SIDE TAPS
Models equipped with Combo Heating capabilities are shipped with the two side plumbing taps OPEN (item 8 and item 13 in Figure 1 and see also Figure 8 & Figure 28). If the heater is to be operated without using the side taps these openings must be plugged with the two pipe plugs supplied with the heaters.
WATER PIPING - MIXING VALVE USAGE
Mixing Valves
Water temperature over
DANGER
125°F can cause severe burns instantly resulting in severe injury or death.
Children, the elderly and the disabled and are at highest risk of scald injury.
Feel water before bathing or showering.
HOT
HOT
Temperature limiting devices such as mixing valves must be installed when required
BURN
by codes and to ensure safe temperatures at fixtures.
Water heated to a temperature which satisfies space heating, clothes washing, dish washing, and other sanitizing needs can scald and cause permanent injury upon contact. Short repeated heating cycles caused by small hot-water uses can cause a temperature increase of the hot water by 20F° higher than the heater’s temperature settings.
SUGGESTED PIPING ARRANGEMENT FOR SIDE CONNECTIONS
COLD-WATER
INLET
TEMPERATURE-
PRESSURE
RELIEF VALVE
DISCHARGE PIPE (DO NOT CAP OR PLUG)
SHUT-OFF
VALV E
TEMPERED POTABLE WATER
MIXING VALVE
CERTAIN
MODELS ARE EQUIPPED WITH SIDE PLUMBING
CONNECTIONS
FOR SPACE
HEATING.
* NOTE: THE
T&P VALVE
DISCHARGE
PIPE SHALL
BE PIPED
DIRECTLY TO
THE DRAIN
OR EXTERNAL
TO THE
BUILDING
METAL DRAIN
PAN 1.75 in.
MAX. DEPTH.
AT LEAST 2 in.
GREATER THAN
THE DIAMETER OF THE WATER
HEATER.
This appliance has been design certified as complying with American National Standard/CSA Standard for water heaters and certain models with side plumbing connections are considered suitable for Water (Potable) Heating and Space Heating.
Note: Do not use in space heating only applications.
The water supply pressure should not exceed 80 psi. If this occurs, a pressure reducing valve with a bypass should be installed in the cold water inlet line. This should be placed on the supply to the entire house in order to maintain equal hot and cold water pressures.
SUGGESTED PIPING ARRANGEMENT FOR
TOP CONNECTIONS
COLD-WATER
INLET
NON-TEMPERED
WATER RETURN
TEMPERATURE­PRESSURE RELIEF VALVE
* NOTE: THE
T&P VALVE
DISCHARGE
PIPE SHALL
BE PIPED
DIRECTLY TO
THE DRAIN
OR EXTERNAL
TO THE
BUILDING
DISCHARGE PIPE (DO NOT CAP OR PLUG)
DRAIN VALV E
SHUT-OFF
VALV E
TEMPERED POTABLE WATER
NON-TEMPERED
WATER SUPPLY
MIXING VALVE
MASSACHUSETTS: INSTALL A VACUUM RELIEF IN COLD WATER LINE PER SECTION 19 MGL
142.
METAL DRAIN
PAN 1.75 in.
MAX. DEPTH.
AT LEAST 2 in.
GREATER THAN
THE DIAMETER OF THE WATER
HEATER.
6 in. MAX. AIR GAP*
Figure 9.
TEMPERED
POTABLE
WATER
SHUT-OFF
VALV E
COLD-
WATER
SUPPLY
DRAIN VALV E
MASSACHUSETTS: INSTALL A VACUUM RELIEF IN COLD WATER LINE PER SECTION 19 MGL 142.
Figure 8.
100221773_2000189439_Rev. 01 www. lochinvar .com 11
6 in. MAX. AIR GAP*
NON-
TEMPERED
WATER
SUPPLY
TO HOT OUTLET
MIXING
VALV E
Figure 10.
NON-
TEMPERED
WATER
RETURN
TO COLD
INLET
Some people are more likely to be permanently injured by hot water than others. These include the elderly, children, the infirm and the physically/mentally disabled. Table 1 (published by U.S. Government Memorandum,
1978) shows the approximate time-to-burn relationship for normal adult skin. If anyone using hot water provided by the water heater being installed fits into one of these groups or if there is a local code or state law requiring a certain water temperature at the point of use, then special precautions must be taken.
Water
Temperature
°F
Time for 1st
Degree Burns
(Less Severe Burns)
110 (normal shower temp.)
116 (pain threshold)
116 35 minutes 45 minutes
122 1 minute 5 minutes
131 5 seconds 25 seconds
140 2 seconds 5 seconds
149 1 second 2 seconds
154 instantaneous 1 seconds
(U.S. Government Memorandum, C.P.S.C., Peter L. Armstrong, Sept. 15,1978)
Time for Permanent
Burns 2nd & 3rd
Degree (Most
Severe Burns)
Table 1.
In addition to using lowest possible temperature setting that satisfies demand of application, a mixing valve should be installed at water heater (see Figure 8 & Figure 9) or at hot-water taps to further reduce system water temperature. Mixing valves are available at plumbing supply stores. Consult a Qualified Installer or Service Agency. Follow mixing valve manufacturer’s instructions for installation of the valves. Before changing the factory setting on the thermostat, read the “Operating The Temperature Control System” section in this manual.
WATER HEATER OPERATION
Figure 11 shows the water heater’s sequence of operation when a call for heat is initiated. The ignition control module will attempt to light the burner three times. If the ignition control does not detect ignition it will enter lockout mode and flash the corresponding error code.
HEATER
THERMOSTAT
CALLS FOR HEAT
HEATER CONTROL CHECKS TO ENSURE BLOWER PRESSURE
SWITCH IS OPEN
BLOWER IS ENERGIZED
CONTROL CHECKS TO
ENSURE PRESSURE
SWITCH CLOSES
INDICATING BLOWER
IS OPERATING AND
THERE ARE NO VENTING
BLOCKAGES (INLET OR
OUTLET)
IGNITER IS ENERGIZED
AND MAIN GAS VALVE IS
OPENED
MAIN BURNER COMES ON AND THE FLAME IS SENSED BY CONTROL
MAIN BURNER
CONTINUES UNTIL THE
WATER IN THE TANK
REACHES THERMOSTAT
SETTING
MAIN BURNER
SHUTS OFF. BLOWER
CONTINUES FOR A POST
PURGE TIME
HEATER REMAINS
ON STANDBY UNTIL
NEXT CALL FOR
HEAT
Figure 11.
12 www. lochinvar .com 100221773_2000189439_Rev. 01
ELECTRICAL REQUIREMENTS & WIRING DIAGRAM
WARNING
Electric Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
Before plugging in the water heater, always make sure:
The voltage and frequency correspond to that specified
on the water heater wiring diagram.
The electrical outlet has the proper overload fuse or
breaker protection.
1. The unit must be connected to a 120VAC power supply. A dedicated circuit is preferred.
2. The water heater must be properly grounded.
3. This water heater is a polarity sensitive appliance and will not operate properly if the power supply polarity is reversed.
4. Do not use a GFI outlet.
Note: Always reference the wiring diagram for the correct electrical connections.
CAUTION
LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION. VERIFY PROPER OPERATION AFTER SERVICING. POWER VENT WIRING SCHEMATIC.
NOTE: REFER TO THE “Installation Checklist” BEFORE OPERATING THIS HEATER.
N
1
L1
1
EARTH GND
CAPACITOR
3
6
BLOWER
2
5
P1
4
1
4
3
P2
2
1
2
4
P3
1
3
4
7
FLAME SENSOR
6
HOT SURFACE IGNITER
5
PRESSURE SWITCH
HIGH LIMIT SWITCH
3
2
FLAMMABLE VAPOUR SENSOR
After making all electrical connections, completely fill the tank with water and check all connections for leaks. Open the nearest hot-water faucet and let it run for 3 minutes to purge the water lines of air and sediment and to ensure complete filling of the tank. The electrical power may then be turned on. Verify proper operation after servicing. See also “Installation Checklist”.
P4
Circled numbers indicate sequence of operation.
Figure 13.
Figure 12.
100221773_2000189439_Rev. 01 www. lochinvar .com 13
SAFETY LOCKOUTS
This water heater has several lockout features designed to prevent the heater from operating in unsafe conditions.
HIGH LIMIT CONTROLS (ENERGY CUT OFF)
Thermostat/Water Temperature
This feature is a part of the gas control valve/thermostat (see Figure 1, item 11) and limits the maximum water temperature. In the event of the water overheating, this safety feature shuts off the fuel supply to the burner. This ECO is not resettable and the gas control valve/thermostat will need to be replaced by a qualified service technician.
Blower High Limit Switch
This device is located on the blower (see Figure 6, item
49) and limits the maximum temperature of the blower. If the blower temperature rises above the temperature setting, the switch opens causing the heater to shut down. The switch will auto reset once the temperature drops sufficiently.
BLOWER AIR PRESSURE SWITCH
This device, located in the junction box, monitors the air pressure produced by the blower. In the event that the exhaust venting becomes blocked or sufficiently restricted, the switch will shut the heater down (see Figure 6, item
47). If the water heater has not gone into a soft lockout condition, the heater will restart after the blockage is removed (see “Resetting The Heater Control”).
If there is a problem with the wiring of the flammable vapor sensor or the flammable vapor interface, the LED will flash the failure status code (see “System Status And Error Codes”).
* ROTATE LEFT (CCW) TO REMOVE
COVER*
MOUNTING
BRACKET
FLAMMABLE
VAPOR SENSOR
(PULL TO REMOVE)
Figure 14.
FLAMMABLE VAPOR SENSOR
When using a gas fired water heater there is a risk of flammable vapors entering the combustion chamber, being ignited by the burner flame and causing a flashback. In order to detect such flammable vapors before they enter the combustion chamber, this water heater is equipped with a flammable vapor sensor (FVS). It is a chemical­absorption based sensor that is connected to the gas control/thermostat (see Figure 14). When exposed to flammable vapors it will trigger the control to stop the flow of gas and enter the FVS lockout state. While in the FVS lockout state the LED on the control will flash the gas lockout code. (Refer to the “System Status And Error Codes” section of this manual for an explanation of the codes applicable to the control installed on your water heater.) If this error occurs, check around the water heater for sources of chemical contamination such as: flammable vapors including gas vapors, solvents, paint and thinners as well as sources of water and detergents.
Note: Resetting the heater will reset the FVIR circuit if all sources of contamination have been removed and the sensor clears. If all sources of contamination have been removed and the system will not reset, the sensor will need to be replaced (see “Resetting The Heater Control”).
14 www. lochinvar .com 100221773_2000189439_Rev. 01
LOCATING THE NEW WATER HEATER
FACTS TO CONSIDER ABOUT THE LOCATION
Carefully choose an indoor location for the new water heater because the placement is a very important consideration for the safety of the occupants in the building and for the most economical use of the appliance. This water heater is not for use in manufactured (mobile) homes or outdoor installation. Whether replacing an old water heater or putting the water heater in a new location, the following critical points must be observed:
1. Select a location indoors as close as practical to the vent termination or location to which the water heater vent piping is going to be connected, and as centralized with the water piping system as possible.
2. Selected location must provide adequate clearances for servicing and proper operation of the water heater.
3. Ensure the area has a continuous supply of air for combustion, blower dilution and ventilation.
4. Avoid locations that could cause the water heater to freeze from outside air.
5. Selected location must provide access to a properly grounded electrical branch circuit. A dedicated circuit is preferred. Do not use a GFI outlet.
6. Avoid locations that expose the water heater to direct sunlight.
7. Keep combustibles such as boxes, magazines, clothes, etc., away from the water heater area.
Important: Do not use an extension cord to connect the water heater to an electrical outlet. Important: this heater has special venting requirements when installed in areas where the ambient temperatures exceed 110°F (see “Polypropylene Vent Systems”).
CAUTION
Property Damage Hazard
All water heaters eventually leak.
Do not install without adequate drainage.
Installation of the water heater must be accomplished in such a manner that if the tank or any connections should leak, the flow of water will not cause damage to the structure. For this reason it is not advisable to install the water heater in an attic or upper floor. In all cases, a metal drain pan should be installed under the water heater. Metal drain pans are available at your local hardware store. Such a metal drain pan must have a clearance of at least 1 in. greater than any point on the water heater’s outer jacket and must be piped to an adequate drain. The pan must have a maximum depth of 1.75 in. .
Water heater life depends upon water quality, water pressure and the environment in which the water heater is installed. Water heaters are sometimes installed in locations where leakage may result in property damage, even with the use of a metal drain pan piped to a drain. However, unanticipated damage can be reduced or prevented by a leak detector or water shut-off device used in conjunction with a piped metal drain pan. These devices are available from some plumbing supply wholesalers and retailers, and detect and react to leakage in various ways:
Sensors mounted in the metal drain pan that trigger an
alarm or turn off the incoming water to the water heater when leakage is detected.
Sensors mounted in the metal drain pan that turn off
the water supply to the entire building when water is detected in the metal drain pan.
Water supply shut-off devices that activate based on
the water pressure differential between the cold-water and hot-water pipes connected to the water heater.
Devices that will turn off the gas supply to a gas water
heater while at the same time shutting off its water supply.
STORAGE OF FLAMMABLE LIQUIDS
Flammable liquids (such as gasoline, solvents, propane (LP or butane, etc.) and other substances (such as adhesives, paints, etc.) emit flammable vapors which can be ignited by a gas water heater’s hot surface igniter (HSI) or main burner. The resulting flashback and fire can cause death or serious burns to anyone in the area.
This water heater is equipped with a FV (Flammable Vapor) sensor for detecting the presence of flammable vapors. When the sensor detects those vapors, the unit will shut down and not operate. Should this happen, please refer to the “Troubleshooting Guidelines” section of this manual. Even though this water heater is a flammable vapors ignition resistant (FVIR) water heater and is designed to reduce the chances of flammable vapors being ignited, gasoline and other flammable substances should never be stored or used in the same vicinity or area containing a gas water heater or other open flame or spark producing appliance. Examples of such locations are garages, storage and utility areas.
The water heater must be located and/or protected so it is not subject to physical damage by a moving vehicle.
100221773_2000189439_Rev. 01 www. lochinvar .com 15
WARNING
Fire or Explosion Hazard
Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
Avoid all ignition sources if you smell gas.
Do not expose water heater control to excessive gas
pressure.
Use only gas shown on rating plate.
Maintain required clearances to combustibles.
Keep ignition sources away from faucets after extended
period of non-use.
Read instruction manual before
installing, using or servicing
water heater.
Clearance for servicing
Adequate clearance of 24 in. for servicing this appliance should be considered before installation, such as changing the anodes, etc.
A minimum clearance of 5.5 in. must be allowed for access to replaceable parts such as thermostats, drain valve and relief valve. When installing the heater, consideration must be given to proper location. Location selected should be as close to the wall as practicable and as centralized with the water piping system as possible.
TOP VIEW
OF CLOSET
WITHOUT DOOR
0” MIN. 0” MIN.
AIR INTAKE*
TOP VIEW OF
CLOSET WITH
DOOR
WARNING
FLAMMABLES
FIRE AND EXPLOSION HAZARD
Can result in serious injury or death
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. Storage or use of gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance can result in serious injury or death.
Flammable Vapors
WARNING
Fire Hazard
For continued protection against risk of fire:
Do not install water heater on carpeted floor.
Do not operate water heater if flood damaged.
Clearances to combustibles
Minimum clearances between water heater and combustibles are 0 in. at the sides and rear, 5.5 in. from the front and 12 in. from top (standard clearance.) If clearances stated on the heater differ from standard clearances, install water heater according to clearances stated on the heater (see Figure 15).
0” MIN.
* DO NOT BLOCK OR RESTRICT IN ANY MANNER,
THE AIR INTAKES AT THE BACK OF THE WATER HEATER.
5.5” MIN.
Figure 15.
A gas water heater cannot operate properly without the correct amount of air for combustion and ventilation. Do not install in a confined area such as a closet unless you provide air as shown below and described in the ”Air Requirements” section (see Figure 16). Never obstruct the flow of ventilation air for dilution and combustion. If you have any doubts or questions at all, call your gas supplier. Failure to provide the proper amount of combustion air can result in a fire or explosion and cause death, serious bodily injury, or property damage.
WARNING
Breathing Hazard - Carbon Monoxide Gas
• Install water heater in accordance with the instruction manual and NFPA 54.
• To avoid injury, combustion and ventilation air must be taken from outdoors.
• Do not place chemical vapor emitting products near water heater.
Breathing carbon monoxide can cause brain damage or death.
Always read and understand instruction manual.
Floors with carpeting
This water heater must not be installed directly on carpeting. Carpeting must be protected by a metal or wood panel beneath the appliance extending beyond the full width and depth of the appliance by at least 3 in. in every direction, or if the appliance is installed in an alcove or closet, the entire floor must be covered by the panel. Failure to heed this warning may result in a fire hazard.
16 www. lochinvar .com 100221773_2000189439_Rev. 01
Figure 16.
If this water heater will be used in beauty shops, barber shops, cleaning establishments, or self-service laundries with dry cleaning equipment, it is imperative that the water heater or water heaters be installed so that combustion and ventilation air be taken from outside these areas. Propellants of aerosol sprays and volatile compounds, (cleaners, chlorine based chemicals, refrigerants, etc.) in addition to being highly flammable in many cases, will also react to form corrosive hydrochloric acid when exposed to the combustion products of the water heater. The results can be hazardous, and also cause product failure.
INSULATION JACKETS AND BLANKETS
Insulation blankets are available to the general public for external use on gas water heaters but are not necessary with these products. The purpose of an insulation blanket is to reduce standby heat loss encountered with storage tank heaters. Your water heater meets or exceeds the current standards with respect to insulation and standby loss requirements, making an insulation blanket unnecessary. Should you choose to apply an insulation blanket to this heater, you should follow these instructions (For identification of components mentioned below, see Figure 1 through Figure 7). Failure to follow these instructions will restrict the air flow required for proper combustion and dilution, potentially resulting in fire, asphyxiation, serious personal injury or death.
AIR REQUIREMENTS
For safe operation an adequate supply of fresh, uncontaminated air for combustion, dilution and ventilation must be provided. Note: Contaminated or dusty air may cause build-up on the blower wheel resulting in nuisance shut downs.
An insufficient supply of air can cause recirculation of combustion products resulting in contamination that may be hazardous to life. Such a condition often will result in a yellow, luminous burner flame, causing sooting of the combustion chamber, burners and flue tubes and creates a risk of asphyxiation.
Do not install the water heater in a confined space unless an adequate supply of air for combustion, dilution and ventilation is brought into that space using the methods described in the “Confined Space” section that follows.
Never obstruct the flow of dilution/ventilation air. If you have any doubts or questions at all, call your gas supplier. Failure to provide the proper amounts of air can result in a fire or explosion and cause property damage, serious bodily injury or death. The combustion and dilution air inlets are shown in Figure 2. Important: Power Vented water heaters require air for combustion and dilution air for the blower.
Do not apply insulation to the top of the water heater,
as this will interfere with safe operation of the blower assembly.
Do not cover the outer door, thermostat or T&P relief
valve, FV sensor, or Air Intake Snorkel.
Do not cover the “Installation And Operating manual”.
Keep it on the side of the water heater or nearby for future reference.
Do obtain new warning and instruction labels from the
manufacturer for placement on the blanket directly over the existing labels.
Do inspect the insulation blanket frequently to make
certain it does not sag, thereby obstructing combustion air flow.
WARNING
Breathing Hazard - Carbon Monoxide Gas
• Do not obstruct water heater air intake(s) with insulating jacket or blanket.
• Gas and carbcn monoxide detectors are available.
• Install water heater in accordance with the instruction manual and NFPA54.
Air supply must be provided as required by the current edition of “National Fuel Gas Code”, ANSI Z223.1/
NFPA 54.
UNCONFINED SPACE
An Unconfined Space is one whose volume is not less than 50 cubic feet per 1,000 Btu/hr of the total input rating of all appliances installed in the space. Rooms communicating directly with the space in which the appliances are installed, through openings not furnished with doors, are considered a part of the unconfined space.
Makeup air requirements for the operation of exhaust fans, kitchen ventilation systems, clothes dryers and fireplaces should also be considered in determining the adequacy of a space to provide combustion, ventilation and dilution air.
UNUSUALLY TIGHT CONSTRUCTION
In unconfined spaces in buildings, infiltration may be adequate to provide air for combustion, ventilation and dilution of flue gases. However, in buildings of unusually tight construction (e.g., weather stripping, heavily insulated, caulked, vapor barrier, etc.) additional air must be provided using the methods described in the ”Confined Space” section that follows.
Breathing carbon monoxide can cause brain damage or death.
Always read and understand instruction manual.
100221773_2000189439_Rev. 01 www. lochinvar .com 17