Power Direct Vent / Sealed Combustion
Standard Features
• Power Direct Venting System - This 2-pipe closed combustion
system utilizes a stand alone vent to exhaust the byproducts
of combustion, and a separate air intake to provide fresh
combustion air to the unit. Vents to an outside wall using
3” or 4” PVC or CPVC pipe.
• Flammable Vapor Sensor - Sensor detects Flammable Vapors
and will not allow burner operation if vapors are present. The
sensor will also detect ongoing flammable vapor events and
prevent burner operation if present.
• Spark to Pilot Ignition System - The control utilizes a spark
to pilot ignition system. This saves fuel by only operating the
pilot during a hot water demand.
• Microprocessor Control - Electronic control constantly
monitors water temperature and burner status to consistently
and accurately maintain water temperature.
Power Direct Vent
Residential Gas
Water Heaters
• Non-CFC Foam Insulation - Improved formulation provides
uniform tank coverage with a thick blanket of insulating
foam. This non-CFC polyurethane closed cell foam minimizes
standby losses and maximizes heat retention.
• Glass-Lined Steel Tank - The durable glass lining assures
lasting protection against rust and corrosion while providing
clean, clear hot water. This tank is automatically formed,
rolled, and welded to assure a continuous seam for the glass
lining. Each tank is triple-tested to ensure quality.
• Heat Traps - Factory installed, minimizes heat loss
through piping.
• Dielectric Nipples - Factory installed waterways protect the
tank from corrosive action between dissimilar metals, while
providing piping convenience.
• Side Tappings- Provided for space heating applications.
• Temperature & Pressure Relief Valve
• Brass Drain Valve
• 6 Year Limited Warranty*
(See warranty for details)
• 10 Year Extended Warranty Available
(In residential applications)
* 3 year limited warranty on tank and 1 year limited warranty on Parts
when installed in commercial applications
• Concentric Vent Termination (optional) - 3" vent kit
allows for the air and vent to be terminated vertically or
horizontally through a single opening.
Dimensions and Specifications
Natural Gas LP Gas
Model Gal. Btu/hr GPH @ Btu/hr GPH @ 1st Energy Vent Ship.
Number Cap. Input 90ºF Rise Input 90ºF Rise Hour Factor A B C D E F G H Size Wt.
PRN050G 48 60,000 65 60,000 65 100 0.60 5 8-3/4" 22" 32" 65" 67" 52-1/4" 13-3/4" 15-3/4" 3" 212
PRN065G 65 65,000 70 65,000 70 114 0.59 62" 22" 32-1/4" 68" 69-1/2" 55-3/4" 13-3/4" 15-3/4" 3" 246
PRN075G 75 70,000 75 70,000 75 132 0.58 61-3/4" 26" 36" 67-3/4" 69-1/2" 54-1/4" 16-1/4" 19" 3" 301
Notes: All LP heaters are equipped with a cast iron burner. Replace “N” with “L” to indicate LP gas model.
All gas connections are 1/2”.
All water connections are 3/4” NPT on 11” centers.
FOR EASE IN ORDERING
BY MODEL NUMBER
110 VAC, 60 HZ, 3.1 AMP is required for power venting.
Maximum Horizontal & Vertical Vent Length is 45 feet
P R N 065 G
POWER
RESIDENTIAL
DIRECT VENT
NAT. GAS
GALLON
CAPACITY
FVIR
(60 equivalent feet, with 3 - 90º elbows), when using 3” pipe.
Maximum Horizontal & Vertical Vent Length is 85 feet
(100 equivalent feet, with 3 - 90º elbows), when using 4” pipe.
This heater is a 65,000 Btu/hr
Power Direct Vent
natural gas water heater with a
65 gallon storage capacity
Certified for Potable Water and Space Heating Applications
This water heater is suitable for water heating and space heating.
Toxic chemicals, such as those used for boiler water treatment shall
NEVER be introduced into this system. This water heater may
NEVER be connected to any existing heating system or components
previously used with non-potable water heating appliances.
RPD-06
Lochinvar Corporation • 300 Maddox Simpson Pkwy • Lebanon, TN 37090 • 615-889-8900 / Fax: 615-547-1000
www.Lochinvar.com
(Replaces RPD-05 11/10)