Lochinvar PBN0501 User Manual

POWER-FIN®GAS BOILER 501, 751, 1001, 1300 MODELS
POWER-FIN
®
BOILER
Submittal Sheet
PB-Sub-10
JOB NAME ______________________________________________________________________ LOCATION ______________________________________________________________________ ARCH./ENGR.____________________________________________________________________ MECH. CONTRACTOR ___________________________________________________________ MODEL NO. _____________________________________________________________________ TYPE GAS ______________________________________________________________________ Btu/hr INPUT_____________________________________Btu/hr OUTPUT_________________ NOTES
Standard Features
• Up to 87% Thermal Efficiency
• Aquastat with Adjustable Differential
• Sequential & Diagnostic Control Panel
• Digital Display with Alarm & Status LEDs
• Radial Ceramic Burner
• Low NOx Operation Exceeds the most Stringent Air Quality Requirements
• ASME Copper Finned Tube Heat Exchanger
• Gasketless Heat Exchanger Design
• 160 PSI Working Pressure
• Temperature & Pressure Gauge
• Combustion Air Filter
• Hot Surface Ignition
• Adjustable High Limit with Manual Reset
• Down Stream Test Cock
• Zero Clearance to Combustible Materials
• Slide Out Control Panel
• ASME Pressure Relief Valve
• Pump Delay
• Freeze Protection
• Flow Switch
• Small Footprint
• Flame View Port
• 24 Volt Control System
• 10 Year Limited Warranty on Heat Exchanger (See warranty for details)
Optional Equipment
Place an X in the box by all options that apply
Alarm Bell Contacts for Air Louvers Contacts on any Failure Cupro-Nickel Heat Exchanger High Gas Pressure Switch Low Gas Pressure Switch Indoor/Outdoor Control Low Water Cut-Off w/ Manual Reset MP2Sequencer (F9 models only) Harmony Sequencer (M9 models only) Vent Diameter Reducer
Firing Control Systems
F=On/Off Fire M=Modulating Fire
F9 HSI (Standard) M9 Hot Surface Ignition
with Modulation F/M13 GE GAP/FM/IRI F/M7 California Code
Lochinvar Corporation • 300 Maddox Simpson Pkwy • Lebanon, TN 37090 • 615-889-8900/Fax: 615-547-1000
www.Lochinvar.com
1/07–Printed in U.S.A.
Power-Fin Boiler Dimensions & Specifications
Venting Options
Electrical Requirements
Boiler 15 Amp Circuit Required
Sidewall
Vertical
DirectAire Vertical w/ Sidewall Inlet
DirectAire Horizontal w/ Rooftop Inlet
Direct Vent Horizontal
Direct Vent Vertical
Direct Vent Horizontal w/ Reducer
Sidewall w/ Reducer
Intelligent Venting Solutions
Model Btu/Hr Btu/Hr D Gas Air Vent Ship.Wt.
Number Input Output A (F9) (M9) E F G H J Conn. Inlet Size (lbs)
PBN0501 500,000 425,000 44-1/2 5-1/4” 3-1/4” 7-3/4” 11-1/4” 33-3/4” 23-1/4” 6-3/4” 1” 5” 7” 505 PBN0751 750,000 637,000 52-1/4 5-1/4” 3-1/4” 7-3/4” 11-1/4” 41-1/4” 30-3/4” 7” 1-1/4” 5” 9” 554 PBN1001 1,000,000 850,000 59-1/4 4-1/4” 3-1/4” 7-3/4” 11-1/4” 48-1/2” 37-3/4” 7-1/4” 1-1/4” 6” 10” 603 PBN1300 1,300,000 1,105,000 67-3/4 4-1/4” 3-1/4” 7-3/4” 19-1/2” 57” 46-1/4” 8-1/4” 1-1/4” 6” 12” 652
Notes: Change "N" to "L" for LP Gas Model. No deration on LP Gas Models.
Water Connections are 2-1/2" on 6" centers. Performance Data Based on Manufacturer Test Results.