FIRE TUBE BOILER
Submittal Sheet
KHN-Sub-01
KNIGHT FIRE TUBE BOILER
JOB NAME ______________________________________________________________________
LOCATION _____________________________________________________________________
ENGINEER______________________________________________________________________
WHOLESALER __________________________________________________________________
CONTRACTOR __________________________________________________________________
MODEL NO. _____________________________________________________________________
TYPE GAS ______________________________________________________________________
EQUIPMENT TAG________________________________________________________________
NOTES
Input MBH
Model
Number
KHN055 8.3 55 95 51 44 6" 8-3/8" 11-1/8" 10-1/2" 13-1/4" 37-1/2" 32-5/8" 32-1/4" 13-1/4" 3-3/8" 1/2" 1" 2" 2" 160
KHN085 8.5 85 95 79 69 6" 8-3/8" 11-1/8" 10-1/2" 13-1/4" 37-1/2" 32-5/8" 32-1/4" 13-1/4" 3-3/8" 1/2" 1" 2" 2" 165
KHN110 11 110 95 102 89 7-3/8" 9-3/4" 11-1/8" 10-5/8" 14-5/8" 37-3/4" 33" 32-1/2" 14" 4-5/8" 1/2" 1" 3" 3" 170
KHN155 15.5 155 95 144 125 7-3/8" 9-3/4" 11-1/8" 10-5/8" 14-5/8" 37-3/4" 33" 32-1/2" 14" 4-5/8" 1/2" 1" 3" 3" 175
KHN199 19.9 199.9 95 185 161 7-1/2" 10-1/2" 11-1/8" 11-5/8" 15-3/8" 38" 33" 32-3/4" 14" 4-5/8"
KHN285 28.5 285 95 264 229 7-1/2" 10-1/2" 11-1/8" 11-5/8" 15-3/8" 38" 33" 32-3/4" 14" 4-5/8" 1/2" 1-1/4" 3" 3" 205
*Information subject to change without notice. Change “N” to “L” for LP gas models.
AFUE%
Heating
Capacity
MBH
Net
MBH
Gas
Water
Connect.
Connect.
1/2" 1-1/4" 3" 3" 195
Air
Inlet
Vent
Size
Shipping
WeightMin Max A B C D E F G H I J
Firing Codes
M9 Standard Construction
M7 California Code
Smart System™ Features
> Smart System Digital Operating Control
Multi-Color Graphic LCD Display w/Navigation Dial,
Soft Keys and Loch-N-Link™ USB programming
> Three Boiler Setpoint Temperature Inputs
Plus Domestic Hot Water Prioritization
> Built-in Cascading Sequencer for up to 8 Boilers,
with Cascade Redundancy
Multiple Size Boiler Cascade
Lead Lag
Efficiency Optimization
Front End Loading Capability
> Outdoor Reset Control with Outdoor Air Sensor
Programmable for Three Reset Temperature Inputs
> Programmable System Efficiency Optimizers
SH Night Setback
DHW Night Setback
Anti-Cycling
Outdoor Air Reset Curve
Ramp Delay
Modulation Factor Control
Boost Temperature & Time
> Four Pump Control
System Pump with Parameter for Continuous
Operation
Boiler Pump with Variable Speed Control
Domestic Hot Water Pump
Domestic Hot Water Recirculation
> Domestic Hot Water Prioritization
DHW tank piped with priority in the boiler loop
DHW tank piped as a zone in the system with the
pumps controlled by the SMART SYSTEM
DHW Modulation Limiting
Separately Adjustable Space Heat/DHW Switching
Times
> Building Management System Integration
0-10 VDC Input to Control Modulation or Setpoint
0-10 VDC Modulation Rate Output
0-10 VDC Input to Enable/Disable Call for Heat
> Access to BMS Settings through Graphic LCD
Display
> High-Voltage Terminal Strip
120 VAC / 60 Hertz / 1 Phase Power Supply
Three Sets of Pump Contacts
> Low-Voltage Terminal Strip
DHW Recirculation Pump Start/Stop
24 VAC Device Relay
Proving Switch Contacts
Flow Switch Contacts
Alarm on Any Failure Contacts
Runtime Contacts
DHW Thermostat Contacts
3 Space Heat Thermostat Contacts
System Sensor Contacts
DHW Tank Sensor Contacts
Outdoor Air Sensor Contacts
Cascade Contacts
0-10 VDC BMS External Control Contact
0-10 VDC Boiler Rate Output Contacts
0-10 VDC Variable Speed System Pump Signal
Input
0-10 VDC Signal to Control Variable Speed Boiler
Pump
Modbus Contacts
> Time Clock
> Data Logging
Hours Running, Space Heating
Hours Running, Domestic Hot Water
Ignition Attempts
Last 10 Lockouts
> Maintenance Reminder
Custom Maintenance Reminder with
Contractor Contact Information
Installer Ability to De-activate Service Reminder
> Low-Water Flow Safety Control & Indication
> Password Security
> Customizable Freeze Protection Parameters
Standard Features
> ENERGY STAR Most Efficient Product
> 95% DOE AFUE Efficiency
> Modulating Burner with up to 10:1 Turndown
Direct Spark Ignition
Low NOx Operation
ASME Stainless Steel Heat Exchanger
30 PSI ASME Relief Valve
> Vertical & Horizontal Direct Vent
PVC, CPVC, Polypropylene or SS Venting up to 100
feet
> Smart System Control
> Condensate Trap
> Other Features
Automatic Reset High Limit
Adjustable High Limit w/Manual Reset
Boiler Circulating Pump
Zero Clearances to Combustible Materials
12-Year Limited Warranty (See Warranty for
Details)
5-Year Limited Parts Warranty
Optional Equipment
CON·X·US® Remote Connectivity
Modbus Communication
BACnet MSTP
Flow Switch
Low-Water Cutoff w/Manual Reset & Test
Alarm Bell
Concentric Vent Kit
SMART SYSTEM™ PC Software
Condensate Neutralization Kit
BMS Gateway to LON or BACnet IP
Multi-Temperature Loop Control
Sidewall Vent Termination
Wireless Outdoor Sensor
LP Gas Conversion Kit