CREST
COMMERCIAL BOILER
Submittal Sheet
FBN-Sub-06
CREST COMMERCIAL CONDENSING BOILER
JOB NAME ______________________________________________________________________
LOCATION ______________________________________________________________________
ENGINEER_______________________________________________________________________
WHOLESALER __________________________________________________________________
CONTRACTOR __________________________________________________________________
MODEL NO. _____________________________________________________________________
TYPE GAS ______________________________________________________________________
EQUIPMENT TAG________________________________________________________________
NOTES
H
RELIEF
VALVE
66-5/8"
14-7/8"
10 -1/4"
DRAIN
BACK
4" FLG
OUTLET
4" FLG
INLET
80"
11"
8"
CONDENSATE
DRAIN
HIGH
VOLTAGE
LOW
VOLTAGE
VENT
B
C
D
E
G
A
TOP
AIR
GAS
F
SIDE
LOW
VOLTAGE
DRAIN
J
K
WATER
OUTLET
WATER
INLET
HIGH
VOLTAGE
Crest Heating Boiler Dimensions and Specifications
Model Input Input AHRI NET AHRI
Number MBH MBH Thermal Output Rating Turndown
Min. Max. % MBH MBH
FB*2500 125 2,500 92.0% 2,300 2,000 20:1
FB*3000 150 3,000 92.0% 2,760 2,400 20:1
FB*3500 200 3,500 92.0% 3,220 2,800 18:1
FB*4000 335 4,000 93.0% 3,720 3,235 12:1
FB*5000 500 5,000 93.0% 4,650 4,043 10:1
Notes: *Insert “N” for natural gas, “L” for LP gas models and “D” for dual fuel. Indoor installation only. Information subject to change without notice.
†
Turndown rate reduced on LP gas models. Low NOx on FB2500-FB5000 models, consult factory.
†
Gas Air Vent Operating Shipping
A B C D E F G H J K Conn. Inlet Size Wt. (lbs.) Wt. (lbs.)
34-1/4” 76-3/8” 70-1/4” 17-3/4” 26-1/8” 9-3/4” 27-3/8” 6-1/4” 78” 83” 2” 8” 9” 3,652 2,560
40-1/2” 83-5/8” 76-3/8” 17-3/8” 31-3/8” 9-7/8” 34-3/4” 8-1/2” 82-1/8” 87-1/8” 2” 10” 10” 4,126 2,920
40-1/2” 83-1/4” 75-5/8” 17-1/4” 31-3/8” 9-7/8” 34-3/4” 7-1/4” 81-1/8” 86-1/8” 2” 10” 10” 4,744 3,225
53-1/2” 109” 100-3/4” 31-1/4” 40-3/4” 14-1/2” 45-3/4” 12-1/2” 104-1/4” 108-1/4” 2-1/2” 12” 12” 6,900 4,750
53-1/2” 107” 100-3/4” 28” 40-3/4” 11” 45-1/2” 9” 104” 108-1/4” 2-1/2” 14” 14” 8,000 5,550
Codes & Registrations
NSI Z21.13/CSA Certified
A
ASME certified, “H” Stamp / National Board
California Code Compliant
CSD1 / Factory Mutual / GE Gap Compliant
Bay Area Air Quality Management
District Qualified
Canadian Registration Number (CRN)
AHRI Certified
Smart Touch™ Features
CON·X·US® Remote Connect
SMART TOUCH™ Touchscreen Operating Control
Full-Color 8” Touchscreen LCD Display
Built-in Cascading Sequencer for up to 8 Boilers
Built-in Redundancy
Cascade Multiple Sized Boilers
Lead/Lag Cascade
Efficiency Optimized Cascade
Front-End Loading Capability with Copper-Fin II®
and Power-fin® Boilers
Building Management System Integration with
0-10 VDC Input
BACnet MSTP Communications
Modbus Communications
Outdoor Reset Control with Outdoor Air Sensor
Password Security
Domestic Hot Water Prioritization
DHW tank piped with priority in the boiler loop
DHW tank piped as a zone in the system with
the pumps controlled by the Smart System
DHW Modulation Limiting
Separately Adjustable SH/DHW Switching Times
Low Water Flow Safety Control & Indication
Inlet & Outlet Temperature Readout
Freeze Protection
Service Reminder
Time Clock
Data Logging
Hours Running, Space Heating
Hours Running, Domestic Hot Water
Hours Running, Modulation Rate
Ignition Attempts
Last 10 Lockouts
Programmable System Efficiency Optimizers
Night Setback
Anti-Cycling
Outdoor Air Reset Curve
Ramp Delay
Boost Temperature & Time
Three Pump Control
System Pump
Boiler Pump
Domestic Hot Water Pump
High-Voltage Terminal Strip
120 VAC / 60 Hertz / 1 Phase Power Supply
(FB2500-3500)
208 VAC / 60 Hertz / 3 Phase Power Supply
(FB4000-5000)
System Pump, Boiler Pump and DHW Pump Power
Low-Voltage Terminal Strip
24 VAC Auxiliary Device Relay
Auxiliary Proving Switch Contacts
Alarm on Any Failure Contacts
Runtime Contacts
DHW Thermostat Contacts
Unit Enable/Disable Contacts
System Sensor Contacts
DHW Tank Sensor Contacts
Outdoor Air Sensor Contacts
Cascade Contacts
0-10 VDC BMS External Control Contact
Standard Features
Up to 93% Thermal Efficiency (AHRI)
Up to 99% Thermal Efficiency in Low
Temperature Applications
Modulating Burner with up to 25:1 Turndown
Direct-Spark Ignition
Low-NOx Operation
Sealed Combustion
Low Gas Pressure Operation
Vertical or Horizontal Venting
Category IV Venting up to 100 Feet
ASME “H” Stamped Heat Exchanger
316L Stainless Steel Fire Tubes
160 psi Working Pressure
On/Off Switch
Adjustable High Limit with Manual Reset
Low Water Cutoff with Manual Reset & Test
High & Low Gas Pressure Switches w/Manual Reset
Low Air Pressure Switches
Condensate Trap w/ Blocked Drain Switch
Drain Valve
System Sensor
Outdoor Air Sensor
Inlet & Outlet Temperature Sensors
High Voltage Terminal Strip
Low Voltage Terminal Strip
Downstream Gas Test Cocks
50 psi ASME Relief Valve
Temperature & Pressure Gauge
Zero Clearances to Combustible
Materials
10-Year Limited Warranty (See Warranty
for Details)
1-Year Warranty on Parts (See Warranty
for Details)
Optional Equipment
Alarm Bell
BMS Gateway - BACnet IP or LonWorks
Condensate Neutralization Kit
SMART TOUCH PC Software
Common Vent Kits
Dual Fuel Gas Train
75 psi ASME Relief Valve
100 psi ASME Relief Valve
125 psi ASME Relief Valve
150 psi ASME Relief Valve
Air Filter Box
Motorized Isolation Valve
Variable Speed Boiler Pump
Electrical Options (Shipped Loose):
208V/3Ø/60Hz (Models FB2500-3500 only)
480V/3Ø/60Hz
600V/3Ø/60Hz
Venting Options
Direct Vent Vertical
Direct Vent Horizontal
Vertical Vent with Sidewall Air Intake
Sidewall Vent with Rooftop Air Intake
Vertical Vent with Optional Room Air
Sidewall Vent with Optional Room Air
Common Vent