Lochinvar Corporation • 300 Maddox Simpson Pkwy • Lebanon, TN 37090 • 615-889-8900 / Fax: 615-547-1000
www.Lochinvar.com
ER2-02
PIP-10M-3/05-Printed in U.S.A
Standard Features
• 88% Thermal Efficiency
• Digital Temperature Control
• Gasketless Heat Exchanger
• CPVC or PVC Ready
• “Fail Safe” Ignition System
• Remote Control Ready
• Power Induced Blower
• Sealed Combustion Chamber
• Stainless Steel Burners
• Loch-Heat
TM
Ceramic Tile
• 24v Terminal Strip
• Built-in Air and Water
Pressure Switches
• Glass-Lined, Cast Iron Header
with Built-in Bypass
• Low NOx Emissions Meet the
Most Stringent Standards
• Outdoor Venting
• 3 Year Limited Warranty on
Heat Exchanger
• 2 Year Limited Warranty on Parts
(see warranties for details)
EnergyRite22Dimensions
FOR EASE IN ORDERING
By Model Number
This is an EnergyRite
2
Natural Gas Pool Heater
with 300,000 Btu/hr input.
E R N 301
EnergyRite
2
Series
Fuel
Type
Btu/hr
Input
*Note: Change “N” to “L” for LP Gas Models. No deration for LP on outdoor
applications. Output based on 88% thermal efficiency. Water connections 2" NPT.
MODEL Btu/hr Btu/hr SHIPPING
NUMBER INPUT OUTPUT INTAKE VENT WEIGHT
ERN151 150,000 132,000 4" 5" 235
ERN201 199,999 175,999 4" 5" 255
ERN251 250,000 220,000 4" 5" 275
ERN301 300,000 264,000 5" 5" 290
ERN401 399,999 351,999 5" 6" 315
MODEL GAS
NUMBER A B D E CONN.
ERN151 24-3/4" 23" 12-1/2" 6" 3/4"
ERN201 24-3/4" 26-1/2" 14-3/4" 6" 3/4"
ERN251 24-3/4" 30-1/4" 17" 6" 3/4"
ERN301 24-3/4" 33-3/4" 18-1/2" 6-1/2" 3/4"
ERN401 24-3/4" 41" 22-1/4" 7" 3/4"
Optional Equipment
• Cupro-Nickel Heat Exchanger
• Alarm Bell
• ASME Certification
• Combustion Floor Shield
• ASME Relief Valve
• Indoor Venting Solutions
POOL HEATER SIZING CHART
Desired Temperature Rise
Model 10°F 15°F 20°F 25°F 30°F
Number Pool Surface Area in Sq. Ft.
ERN151 1257 838 629 503 419
ERN201 1676 1117 838 670 559
ERN251 2095 1397 1048 838 698
ERN301 2514 1676 1257 1006 838
ERN401 3352 2235 1676 1341 1117
NOTE: Sizing is based on a 3-1/2 MPH average wind velocity for elevations
up to 2,000 feet above sea level. For each 1,000 feet above 2,000 feet
elevation, add 4% to the surface area of the pool.
SPA & HOT TUB SIZING CHART
Spa/Tub Size in US Gallons
Model 200 300 400 500 600 700 800 900 1000
Number
Time (Minutes) required to raise temperature
ERN151 23 34 45 57 68 80 91 102 114
ERN201 17 26 34 43 51 60 68 77 85
ERN251 14 20 27 34 41 48 55 61 68
ERN301 11 17 23 28 34 40 45 51 57
ERN401 9 13 17 21 26 30 34 38 43
NOTE: Sizing is based on a 30°F temperature rise. To adjust for other
temperature rises divide the time listed in the table by the temperature ratio.
Example: for a 15°F temperature rise divide by 2 (30/15=2).
Swimming Pool Sizing
• Determine your pool's surface area in square feet.
• Determine the desired temperature rise by subtracting
the average air temperature from the desired pool
temperature.
• In the table below locate the surface area equal to,
or just greater than, your pool's surface area at the
desired temperature rise.
• Read to the left for the appropriate EnergyRite²
model number.
Spa and Hot Tub Sizing
• Determine your Spa/Hot tub's capacity in U.S. gallons
by multiplying the surface area (in square feet) by the
average depth (in feet), then by a conversion factor of
7-1/2. (1 ft³ = 7-1/2 gallons)
• The table lists the time required (in minutes) to raise the
temperature of different size spa/hot tub's 30°F.
• In the table below locate the gallon capacity equal to
or just greater than your spa/hot tub's size in gallons.
• Select the desired heat up time.
• Read to the left for the appropriate EnergyRite²
model number.
EnergyRite22Pool and Spa Sizing Guides
Optional