Littelfuse KLKR SERIES Catalog Page

POWR-GARD® Fuse Datasheet

CLASSCCKLKRSERIESFUSES

600 VAC • 300 VDC • Fast-Acting • 1/10-30 A

Description

KLKR Series Class CC fuses are fast-acting fuses intended for general purpose branch circuit protection. Their compact size, fast-acting overload response, and highly currentlimiting design make them ideal for use in OEM equipment and control panels.

Features/Benefits

Meets UL and CSA standards

Class CC fuses are the smallest 600 V, 200,000 A.I.R. fuses approved for branch circuit protection

Rejection feature prevents use of fuses with lower interrupting ratings or voltage ratings when used with corresponding fuse holders

Extremely current limiting reduces damage caused by heating and magnetic effects of short-circuit currents

Applications

General purpose protections for equipment requiring fast overload protection

Specifications

Voltage Rating

 

AC: 600 V

 

 

 

 

 

 

DC: 300 V

 

 

 

Amperage Rating

 

1/10 – 30 A

 

 

 

Interrupting Rating

AC: 200 kA rms symmetrical

 

 

 

 

DC: 20 kA

 

 

 

Material

 

Body: Melamine

 

 

 

 

 

 

Caps: Nickel-plated Bronze

 

Fuse Weight

 

1/10 – 1 A: .030 lb (13.61g)

 

 

 

 

11/2 – 30 A: .034 lb (15.42g)

 

Approvals

 

AC: Standard 248-4, Class CC

 

 

 

 

 

UL Listed 1/10-30 A (File: E81895)

 

 

 

 

 

CSA Certified 1/10-30 A (File: LR29862)

 

 

 

DC: Littelfuse self-certified

 

Environmental

 

RoHS Compliant

 

 

 

Country of Origin

 

Mexico

 

 

 

Ordering Information

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AMPERAGE RATINGS

 

 

 

1/10

 

1/2

 

2 1/2

 

6

 

12

1/8

 

3/4

 

3

 

7

 

15

2/10

 

1

 

3 1/2

 

8

 

20

1/4

 

1 1/2

 

4

 

9

 

25

3/10

 

2

 

5

 

10

 

30

Dimensions Inches (mm)

1.50

.25

(6.4)

(38.1)

 

0-30 A

.41

(10.3)

.50

.125

(3.2)

(12.7)

 

Littelfuse KLKR SERIES Catalog Page

POWR-GARD® Fuse Datasheet

CLASSCCKLKRSERIESFUSES

Electrical Specifications

ORDERING

AMPERAGE

VOLTAGE

INTERRUPTING

WATTS LOSS AT 100%

WATTS LOSS AT 80%

TOTAL CLEARING I2T

AGENCY

RATING

RATING

APPROVALS RoHS

NUMBER

RATING

RATED CURRENT (W)

RATED CURRENT (W)

2

 

 

(A SEC) 200 kA

 

 

 

AC

DC

AC

DC

 

 

 

 

UL

VDE

 

KLKR001.T

1

600

300

200 kA

20 kA

 

0.20

0.38

80

KLKR006.T

6

600

300

200 kA

20 kA

 

0.77

1.36

210

KLKR012.T

12

600

300

200 kA

20 kA

 

0.83

1.58

6520

KLKR030.T

30

600

300

200 kA

20 kA

 

2.10

3.75

1720

Peak Let-Thru Curve

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1000000

 

 

 

 

 

 

 

 

 

 

 

 

100000

 

 

 

 

 

 

 

 

 

 

 

<![if ! IE]>

<![endif]>AMPERES

10000

 

 

 

 

 

 

 

 

 

 

 

<![if ! IE]>

<![endif]>THRU IN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30 A

 

 

 

 

 

 

<![if ! IE]>

<![endif]>LET-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

25 A

 

 

 

 

 

 

<![if ! IE]>

<![endif]>PEAK

 

 

 

 

 

20 A

 

 

 

 

 

 

 

 

 

 

 

15 A

 

 

 

 

 

 

 

 

 

 

 

 

12 A

 

 

 

 

 

 

 

1000

 

 

 

 

 

 

 

 

 

 

 

 

100

 

 

 

 

 

 

 

 

 

 

 

 

<![if ! IE]>

<![endif]>100

 

<![if ! IE]>

<![endif]>1000

<![if ! IE]>

<![endif]>10000

<![if ! IE]>

<![endif]>100000

<![if ! IE]>

<![endif]>200000

 

 

 

 

 

 

 

 

 

AVAILABLE FAULT CURRENT

 

 

 

 

 

 

 

 

 

 

 

SYMMETRICAL R. M. S. AMPERES

 

 

 

 

 

Loading...