Listen Technologies IS 6132P User Manual

DCS 6000
User Manual
Digital Conference System
IS 6132P Interpreter Set
with firmware 5.3.xx or later
Danish Interpretation Systems DIS
Danish Interpretation Systems User Manual
Copyright © 2006 DIS IS6132 REV M.DOC 04-05-2006 No part of this publication may be reproduced or utilised in any form or by any means without permission in writing from the
publisher
Danish Interpretation Systems User Manual
List of Contents
List of Contents..................................................... 3
Important.............................................................. 4
Compliancy........................................................ 4
Installation precautions.................................... 4
Cleaning............................................................. 4
Repacking.......................................................... 4
Warranty ........................................................... 4
Description of the DCS 6000 system................... 5
Features.............................................................. 5
System components........................................... 6
Central equipment etc...................................... 6
Interpreter equipment...................................... 6
Conference equipment and channel selectors. 6
Operating instructions......................................... 7
IS 6132 P Interpreter Set..................................7
General description..........................................7
Features............................................................7
User Controls, indications & connectors.........7
Set up for each interpreters set.........................9
Normal operation...........................................11
System Setup........................................................14
Typical schematics...........................................14
Appendix..............................................................15
Language list....................................................15
Technical appendix..........................................16
Cabling...........................................................16
Accessories (not supplied).............................17
Technical specifications.................................17
Copyright © 2006 DIS IS6132 REV M.DOC 04-05-2006 No part of this publication may be reproduced or utilised in any form or by any means without permission in writing from the
publisher
Danish Interpretation Systems User Manual
Important
Compliancy
The equipment has been tested and found to comply with the limits of the following standards for digital devices:
EN55103-1 (Emission)
EN55103-2 (Immunity)
FCC rules part 15, class A (Emission)
This device complies with part 15 of the FCC rules. Operation is subject to the following conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial or light industrial environment. The equipment generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with the user manual it may cause harmful interference to radio communications.
You are cautioned that any changes or modifications not expressly approved in this manual could void your authority to operate this equipment.
exposed to direct sunlight, excessive dust or humidity, mechanical vibration or shock.
To avoid moisture condensations do not install the unit where the temperature may rise rapidly.
Cleaning
To keep the cabinet in its original condition, periodically clean it with a soft cloth. Stubborn stains may be removed with a cloth lightly dampened with a mild detergent solution. Never use organic solvents such as thinners or abrasive cleaners since these will damage the cabinet.
Repacking
Save the original shipping cardboard box and packing material; they will become handy if you ever have to ship the unit. For maximum protection, re-pack the unit as originally packed from the factory.
Warranty
The individual units in the DCS 6000 system are minimum covered by 12 months warranty against defects in materials or workmanship.
Installation precautions
Do not install the unit in a location near heat sources such as radiators or air ducts, or in a place
4
Manual 01 18 04445
Danish Interpretation Systems User Manual
Description of the DCS 6000 system
Features
The DCS 6000 system has the following main features:
Fully digital
Excellent sound quality
“State of the Art” fully digital integrated
interpretation, discussion and voting system offering interpretation, language distribution, conference microphone and voting facilities with attendance check with Chip Card ™.
New, unique digital DATA and AUDIO bus.
39 incoming channels (8 floor channels + 31
interpreted channels) and one Line input.
33 distributed channels (2 x floor + 31
interpreted channels)
The Delegate and Interpreter units are powered
and controlled by the CU 6010 Central Unit, which drives up to app. 200 units on 4 chains.
EX 6010 Extension Units or PS 6000 Power
Supplies available if more units are required
A total of 4000 units (delegate and/or
interpreter units) can be connected to the system.
Using screened CAT5 or CAT5e cabling (FTP
or STP) ensuring a very cost effective installation and easy set-up of portable systems
RS232/RS422 connection on CU 6010 for
external operation of the system of a PC or control system such as AMX or Crestron
The SW 6000 is an optional software package, which expands the functionality of the DCS 6000 system. The software runs on standard computer technology (Standard PC with Windows 2000 or XP).
Main features of the SW 6000 are:
Microphone management
Mimic panel operation
Interpretation management
Voting management
Message handling
Agenda handling
Data stored on SQL data base for easy
export/import of data as well as easy links to external databases
Multi language user interfaces
Supports different User types with different
priorities, user interfaces and control possibilities
Variety of printing facilities such as speaker’s
log, voting results, delegates list etc.
Firmware in Delegate units, Interpreter Units,
Central Units etc. upgradeable through serial PC-connection (RS232 or RS422)
Can be operated with or without a PC.
Added functionality and comprehensive
features provided by SW 6000 software package running on PC
Manual 01 18 04445
5
Danish Interpretation Systems User Manual
System components
The CU 6010 Central Unit supports all available units in the DCS 6000 series:
Central equipment etc.
EX 6010 Extension Unit PS 6000 Power Supply AO 6008 Audio Output box RP 6004 Repeater for four chains JB 6002 Junction Box with 2 outputs JB 6004 Junction Box with 4 outputs
Interpreter equipment
IS 6132P Interpreter Set LS 6032P Interpreter Loudspeaker
Conference equipment and channel selectors
CS 6032FV/H Channel Selector (flush mounted) CM/DM 6010P Conference Unit (portable) CM/DM 6020P Conference Unit (portable) with
XLR microphone connector
CM/DM 6070P Conference Unit (portable) with
two built-in channel selectors
CM/DM 6090P Conference Unit (portable) with
two built-in channel selectors and XLR microphone connector
CM/DM 6060F Conference Unit (flush mounted)
with one built-in channel selectors
CM/DM 6510F Conference Unit (flush mounted)
with Chip-card and 3 voting buttons
CM/DM 6560F Conference Unit (flush mounted)
with one built-in channel selector, Chip-card and 3 voting buttons
MU 6040C/D Microphone Unit for use with
customised front plate with Loudspeaker, Microphone and Buttons. Available in Delegate (D) and Chairman (C) version
AM 6040 Ambient Noise Microphone
6