PRODUCT DESCRIPTION
The VB-2 and VB-3 Audio Modules are designed as add-on accessories for the DVS-1200. DVS-2400, and DVS-2408 Security Systems. Each module plugs directly into the unit’s circuit board. The modules provide voice prompts for operating the system and voice feedback for remote command of the system through a pushbutton telephone. The VB-2 module features 2-way audio and audio listen-only capabilities for Central Station monitoring.
The digitally synthesized human voice produced by the module annunciates important system information through the Console’s speaker or through a remote speaker. Both modules are pre-programmed with a multi-word vocabulary. Each time the system’s mode is changed, the voice module will sound the status of the Console and its sensors. The volume control adjusts the voice level.
With either the VB-2 or VB-3 installed, and the Console connected to a t elephone line, local or off-site telephone sets can be used to control and interrogate the DVS-2400 or DVS-2408. To gain access to the system, the user firs t enters their user code. The module’s voice will then prompt the user to press various telephone buttons to control the system. The DVS-1200 can be accessed only from off-side telephones.
The VB-2 module supports 2-way audio communications with the Central St ation. The small microphone supplied fits into the Console’s case. The microphone’s high-gain amplifier allows the Central Station to monitor the sounds in the installation. The Central Station operator can control the direction of the 2-way communications using a pushbutton telephone. In 2-way mode, the operator can talk back to the subscriber through the Console’s speaker or a remote spea ker.
1. COMPONENT LOCATIONS
MICROPHONE
TERMINALS (VB-2 ONLY)
EXTERNAL MICROPHONE (+)
MICROPHONE COMMON (-)
CONSOLE MICROPHONE (+)
MODULE-TO-CONSOLE
CONNECTOR
CUT JUMPER FOR USE WITH OLDER
DVS-2400/DVS-2408 OR IF
FEEDBACK OCCURS
DIGITAL VOICE
VOLUME CONTROL
(SUPPLIED WITH VB-2 ONLY)
GAIN JUMPER
MODULE-TO-CONSOLE
CONSOLE SPEAKER
MICROPHONE
2. CONNECT MICROPHONE 3. PLUG MODULE INTO CIRCUIT BOARD 4. MOUNT MICROPHONE
CONNECT BLACK MICROPHONE WIRE TO CENTER TERMINAL
CONNECT RED MICROPHONE WIRE TO THIS TERMINAL
SEE DVS-2408 INSTALLATION INSTRUCTIONS FOR USE WITH THE DVS-2408
MODEL VB-2
- ONLY -
LINEAR SECURITY SYSTEM
MODEL DVS-2400/DVS-2408/DVS-1200
CIRCUIT BOARD
MODEL: VB-2 OR VB-3
VOICE MODULE
WARNING !
SMALL ARROWS ON
VOICE MODULE POINT UP
REMOVE POWER FROM CONSOLE
LOCATION OF VOICE BOARD INSIDE CONSOLE (ARROWS MUST POINT UP)
START BY INSERTING THIS CONNECTOR PART WAY
COMPLETE INSTALLATION BY ALIGNING PINS ON OTHER CONNECTOR AND CAREFULLY PRESSING THE MODULE IN
BE SURE ALL CONNECTOR PINS ALIGN WITH CIRCUIT
BOARD SOCKETS
WARNING !
PRESS MICROPHONE FIRMLY INTO MICROPHONE MOUNTING HOLE
5. REMOTE SPEAKER & MICROPHONE 6. VOICE SYNTHESIS SETUP 7. REMOTE SYSTEM OPERATION
OPTIONAL REMOTE SPEAKER & MICROPHONE CONNECTIONS
REMOVE JUMPER
SYSTEM MAIN TERMINAL BLOCK
NOTE: REMOVE JUMPER WHEN
USING AN
EXTERNAL
SPEAKER
SPKR SPKR
MIC (-)
MIC (+)
RSM-1 TERMINAL BLOCK
AC AC EXT. SPKR (-) H/A ­H/A + RELAY N.O. RELAY DRY
VB-2 TERMINAL BLOCK
USE TWISTED PAIR WIRE FOR MICROPHONE
EXTERNAL MICROPHONE (+) MICROPHONE COMMON (-) CONSOLE MICROPHONE (+)
RSM-1 TERMINALS
LINEAR MODEL RSM-1
8. CENTRAL STATION AUDIO (VB-2 ONLY)
PROGRAM THE SYSTEM FOR THE DESIRED AUDIO MODE
PRS
7
PROGRAMMING STEP #76
MNO
6
HOM E
PROGRAM
0 FOR NO AUDIO MONITORING 1 FOR LISTEN-ONLY 2 FOR 2-WAY MANUAL 3 FOR 2-WAY FULL DUPLEX
AWAY
STORE PROGRAM
AFTER THE ALARM REPORT IS SENT THE SYSTEM WILL SWITCH TO THE PROGRAMMED AUDIO MODE FOR 90 SECONDS
2-WAY MANUAL
AUDIO MODE
THE "1" AND "3" KEYS ARE NOT USED IN LISTEN-ONLY AUDIO MODE
THE "1" AND "3" KEYS CAN BE USED IN FULL DUPLEX MODE, ALTHOUGH THE MODULE WILL SWITCH TO 2-WAY MANUAL MODE UNTIL THE NEXT CALL
ALL
AUDIO
MODES
START IN LEA RN MODE
PRS
7
PROGRAMMING STEP #78
TUV
8
HOM E
PROGRAM
1
1 FOR SPEAKER ENABLE
AWAY
STORE PROGRAM
SWITCH THE SYSTEM BETWEEN MODES TO TEST THE AUDIO OUTPUT
PRESS "9" TO DISCONNECT THE CALL
9
PRESS "3" TO LISTEN
3
PRESS "1" TO TALK
1
PROGRAM THE CONSOLE TO ENABLE AUDIO FROM THE MODULE TO THE SPEAKER
SYSTEM ARMED
HOME MODE
ADJUST THE MODULE'S VOLUME CONTROL TO SET THE VOICE LEVEL
MODEL VB-2
- ONLY -
FROM A HOUSE PHONE
PRESS
ENTER A USER CODE THEN PRESS #
CONSOLE WILL REPORT MODE, ALARMS, AND TROUBLE
PRESS "1" TO SWITCH SYSTEM TO OFF MODE
1
PRESS "2" TO SWITCH SYSTEM TO CHIME MODE
2
PRESS "3" TO SWITCH SYSTEM TO HOME MODE
3
PRESS "4" TO SWITCH SYSTEM TO AWAY MODE
4
PRESS "5" TO LISTEN TO ALARM STATUS
5
PRESS "6" TO LISTEN TO TROUBLE STATUS
6
7
PRESS "7" TO LISTEN TO SENSOR STATUS
DIAL THE INSTALLATION, LET IT RING TWICE, HANG UP AND DIAL THE INSTALLATION AGAIN (2ND CALL NEEDS TO BE 10-30 SECONDS AFTER 1ST CALL) THEN LISTEN FOR TONE
LINEAR LIMITED WARRANTY
This Linear product is warranted against defects in material and workmanship for twelve (12) months. The Warranty Expiration Date is labeled on the product. This warranty ext ends only to wholesale customers who buy direct from Linear or through Linear’s normal distribution channels. Linear does not warr ant this product to consumers. Consumers should inquire from their selling dealer as to the nature of the dea ler’s warranty, if any. There
are no obligations or liabilities on the par t of Linear corporat ion for consequenti al damages arising out of or in connection with use or performance of this product or other indirect damages with respect to loss o f p rop erty, revenue , or p rofit, o r cost of removal, installation, or reinstallation. All implied warranties, including implied warranties
for merchantability and implied warrantie s for fitness, are valid o nly until W arranty Expiration Date as labeled on the product. This Linear Corporation Warranty is in lieu of all other
warranties express or implied.
All products returned for wa rr anty se rvi ce r equir e a Retur n P r oduct Autho riza tion N umbe r (RPA#). Contact L inear Technical Service at 1-800-4 21-1587 for an RPA# and other important details.
Linear radio controls provide a reliable communications link and fill an important need in portable wireless signalling. However, there are some limitations which must b e observed .
For U.S. installations only: The radios are required to comply with FCC Rules and Regulations as Part 15 devices. As such, they have limited transmitter power and therefore limited range.
A receiver cannot respo nd to mor e than one transm itted signal at a time and may be blocked by radio signals that occur on or near their operating frequencies, regardless of code settings.
Changes or modifications to the device may void FCC compliance.
Infrequently used radio lin ks should be tested regu larly to pr otect against undetected interference or fault.
A general knowledge o f radio and it s vagaries shou ld be gained prior t o acting as a wholesale distributor or dealer, and these facts should be communicated to the ultimate users.
Copyright © 1999 Linear Corporation 214074 B
IMPORTANT !!!
CONNECTOR
2-WAY AUDIO
VOLUME CONTROL
MODEL VB-2
- ONLY -
NOTE: THE SYSTEM MUST BE CONNECTED TO A TELEPHONE LINE TO USE THESE FUNCTIONS
Loading...