SXR-64A
Supervised Wireless Receiver
and Zone Expander
Installation Instructions
(760) 438-7000 • FAX (760) 438-7043
USA & Canada (800) 421-1587 & (800) 392-0123
Toll Free FAX (800) 468-1340
www.linearcorp.com
SYSTEM OVERVIEW CONDITION DISPLAYS COMPONENT LOCATIONS
TYPICAL TRANSMITTERS
TX-91 TX-92 TX-94 T-90D TMD-90 TSD-90A
ST-23A LMT-1/303 MPX/303
UP TO 64 TRANSMITTERS
CAN BE USED
INTRODUCTION
The Model SXR-64A is a 64-channel, 12-zone, supervised wireless receiver/
annunciator designed for use in residential or commercial security systems. Housed
in a rugged metal enclosure, the SXR-64A connects to a hardwired alarm control
panel adding wireless capability to the panel.
The SXR-64A receives signals from a variety of security transmitters then processes,
displays and transfers the signal to the hardwired alarm control panel. Six unique
conditions for each transmitter channel can be shown on the unit’s display. Conditions
such as “Open Portal”, “Transmitter Low Battery”, “Transmitter Tamper” and “First
Alarm In” show the status of each transmitter in the system. Valuable features such
as Alarm Memory and Transmitter Status allow for quick system diagnosis and
troubleshooting.
The receiver’s eight alarm zones and four supervisory zones provide a fl exible
interface to the alarm control panel. Any or all of the zones can be used. All of the
solid state zone outputs can be either normally open or normally closed electrical
confi guration and can switch up to 100 mA @ 24 VDC.
An easy programming interface using four pushbuttons lets the installer quickly setup
the system. The UP, DOWN, ADVANCE and MEMORY buttons are located inside the
receiver case and are used for transmitter and system programming.
An on-board, high-gain, superheterodyne radio receiver gives the SXR-64A excellent
reception. The MODE indicator shows RF activity. The local whip antenna (supplied)
or remote external antenna (Model EXA-1000) connects to the receiver through a
standard type “F” connector.
The SXR-64A decodes Linear’s SX, S1, and MegaCode™ format transmitters. The
SXR-64A can be used as a direct replacement for Linear’s SS-32, SSR-32, & SXR-64
receivers with an installation bonus of being able to use up to 64 transmitters in the
system.
Power for the SXR-64A is provided from the alarm control panel. To control the alarm
memory, reset tamper and status alert conditions, an armed input on the receiver
connects to an armed output from the control panel.
CONDITIONS FOR ALL TRANSMITTERS
ROTATE ON THE DISPLAY
OPEN PORTAL
ALL TRANSMITTERS WILL CAUSE THIS CONDITION WHEN AN ALARM SIGNAL IS
SENT. THE CONDITION WILL REMAIN UNTIL A RESTORE SIGNAL IS SENT, UNLESS
THE TRANSMITTER IS SET AS "AUTO RESTORE". THE CHANNEL'S ZONE OUTPUT
WILL BE FAULTED WHEN THIS CONDITION IS DISPLAYED.
FIRST ALARM IN
WHEN THE PANEL IS ARMED, THE FIRST ALARM SIGNAL SENT WILL CAUSE THIS
CONDITION. IF THE CHANNEL IS SET AS "DELAYED", THIS CONDITION WILL OCCUR
AFTER ANY DELAYS IF THE PANEL IS NOT DISARMED. DISPLAY WILL CLEAR THE
NEXT TIME THE PANEL IS RE-ARMED.
ADDITIONAL ALARMS IN
WHEN THE PANEL IS ARMED, ADDITIONAL ALARM SIGNALS SENT WILL CAUSE THIS
CONDITION. IF THE CHANNEL IS SET AS "DELAYED", THIS CONDITION WILL OCCUR
AFTER ANY DELAYS IF THE PANEL IS NOT DISARMED. DISPLAY WILL CLEAR THE
NEXT TIME THE PANEL IS RE-ARMED.
TRANSMITTER LOW BATTERY
ANY TRANSMITTER THAT CAN SEND A LOW BATTERY SIGNAL WILL CAUSE THIS
CONDITION WHEN ITS BATTERY IS LOW. DISPLAY WILL REMAIN UNTIL A SIGNAL
FROM THE SAME TRANSMITTER WITH A GOOD BATTERY IS SENT.
FEATURES
✶ 64 Programmable Transmitter Channels
✶ 8 Alarm Zones
✶ 4 Supervisory Zones
✶ Rugged Metal Enclosure
✶ Six Condition Displays for Each Transmitter
✶ Alarm Memory with First-Alarm-In
✶ Automatic Supervised Operation
✶ Transmitter Contact State Monitoring
✶ Transmitter Tamper Monitoring
✶ Transmitter Low Battery Monitoring
✶ Transmitter Status Report Monitoring
✶ Easy Installer Programming Interface
✶ High-gain Superheterodyne Receiver
✶ Receiver Automatic Gain Control
✶ Antenna Connector
✶ Decodes 303.875 MHz SX, S1, & MegaCode™ Format Transmitters
✶ Optional Display Blanking while Armed
✶ RF Activity Indicator
✶ Positive or Negative Armed Input
ANTENNA CONNECTOR
TYPE "F" ANTENNA CONNECTOR FOR
CONNECTION TO LOCAL OR REMOTE
ANTENNA THROUGH RG-59 COAX
LIGHTS WHEN UNIT IS
IN PROGRAM MODE,
FLASHES WHEN RF IS
RECEIVED IN RUN
MODE
TEST POINTS
AUDIO TEST
POINTS FOR
LISTENING TO
RADIO INPUT
WITH BUTTSET
MODE LIGHT
TRANSMITTER DISPLAY
SHOWS THE TRANSMITTER'S
CHANNEL NUMBER AND IS USED
DURING PROGRAMMING
SHOWS THE TRANSMITTER'S
CONDITION AND IS USED DURING
PROGRAMMING
CONDITION DISPLAY
MEMORY LIGHT
LIGHTS DURING PROGRAM
MODE TO SHOW WHEN A
TRANSMITTER HAS BEEN
ENTERED OR AN OPTION
HAS BEEN SELECTED,
LIGHTS DURING RUN MODE
WHEN SYSTEM IS ARMED,
BLINKS DURING EXIT DELAY
MEMORY BUTTON
USED DURING PROGRAMMING
TO SELECT OPTIONS AND
ENTER TRANSMITTERS
SXR-64A RECEIVER ALARM CONTROL PANEL
INSTALLATION TIPS MOUNTING UNIT ANTENNA INSTALLATION
90% - 100%
OF FULL POWER
CONSTRUCTION
MATERIALS WILL
EFFECT RADIO RANGE
WALLBOARD AND
WOOD STUDS
RCVR
BASEMENT
MOUNT RECEIVER OR ANTENNA AS HIGH ABOVE
TRANSMITTER
MOUNTING WILL
EFFECT RADIO
RANGE
RIGHT
EARTH LEVEL AS POSSIBLE
RIGHT
CENTRALLY LOCATE RECEIVER
OR ANTENNA
TX
DOOR
Min.
3 ft.
RIGHT
RECEIVER (ANTENNA)
LOCATION EFFECTS
RADIO RANGE
Concrete
slab
floor
65% - 95%
OF FULL POWER
LIGHT CONCRETE
OR BRICK
LOCATING A RECEIVER OR ANTENNA BELOW
TRANSMITTERS AT THE OTHER END OF
Less
than
DOOR
3 ft.
above
slab
TX
WRONG!
OF FULL POWER
CONCRETE WITH STEEL
REINFORCEMENT OR
METAL LATH AND PLASTER
BASEMENT
WRONG!
EARTH LEVEL WILL IMPAIR RANGE
WRONG!
HOUSE MIGHT BE TOO FAR AWAY
Wall
Concrete
slab
floor
TX
10% - 70%
RCVR
WRONG!
TERMINAL BLOCK DETAILS TYPICAL CONTROL PANEL CONNECTION S1 FORMAT TRANSMITTER DETAILS
ZONE OUTPUTS
TEST OUTPUT
SXR-64A TERMINALS
FOR CONNECTION TO THE ALARM
CONTROL PANEL'S AUXILIARY
POWER OUTPUT. POWER INPUT
CAN BE FROM 11-16 VDC ONLY
FOR CONNECTION TO THE ALARM
CONTROL PANEL'S ARMED OUTPUT.
THE ARMED INPUT CAN BE SET FOR
ARMED-POSITIVE OR
ARMED-NEGATIVE POLARITY.
POWER INPUT
ARMED INPUT
1 2 3 4 5 6 7 8 9 1011121314151617181920
ZN1 COM ZN2 ZN3 COM ZN4 ZN5 COM ZN6 ZN7 COM ZN8 LB STS COM TMP TST ARM
FOR CONNECTION TO ALARM ZONE INPUTS ON THE ALARM
CONTROL PANEL. ZONE OUTPUT WILL ACTIVATE WHEN ANY
TRANSMITTER CHANNEL PROGRAMMED FOR THAT ZONE IS
IN THE FAULTED (ALARM/OPEN) CONDITION ("O" DISPLAYED
ON THE CONDITION DISPLAY).
FOR CONNECTION TO A TROUBLE ZONE ON THE ALARM
CONTROL PANEL. OUTPUT WILL ACTIVATE WHEN ANY
TRANSMITTER CHANNEL DISPLAYS AN "L" ON THE
CONDITION DISPLAY.
FOR CONNECTION TO A TROUBLE ZONE ON THE ALARM
CONTROL PANEL. OUTPUT WILL ACTIVATE WHEN ANY
TRANSMITTER CHANNEL DISPLAYS AN "S" ON THE
CONDITION DISPLAY.
FOR CONNECTION TO A TROUBLE ZONE ON THE ALARM
CONTROL PANEL. OUTPUT WILL ACTIVATE WHEN ANY
TRANSMITTER CHANNEL DISPLAYS A "P" ON THE CONDITION
DISPLAY OR WHEN ANY PROGRAMMING BUTTON IS
PRESSED WHILE THE SYSTEM IS ARMED.
FOR CONNECTION TO A TEST ZONE ON THE ALARM
CONTROL PANEL. OUTPUT WILL ACTIVATE WHEN ANY
TRANSMITTER THAT CAN SEND A TEST SIGNAL HAS ITS
TEST BUTTON PRESSED.
NOTES:
1. ALL COM TERMINALS ARE COMMON GROUND
AND CONNECTED TOGETHER.
2. ALL OUTPUTS CAN BE PROGRAMMED FOR NORMALLY
OPEN OR NORMALLY CLOSED OPERATION. EACH OUTPUT
RETURNS TO ANY COM TERMINAL.
3. EACH OUTPUT CAN SWITCH UP TO 100 mA @ 24 VDC
MAXIMUM.
LOW BATTERY OUTPUT
STATUS OUTPUT
TAMPER OUTPUT
TRANSMITTER TAMPER
ANY TRANSMITTER THAT CAN SEND A TAMPER SIGNAL WILL CAUSE THIS
CONDITION WHEN IT IS TAMPERED. DISPLAY WILL CLEAR THE NEXT TIME THE
PANEL IS ARMED.
TRANSMITTER STATUS ALERT
IF THE RECEIVER DOES NOT RECEIVE STATUS SIGNALS FROM A TRANSMITTER
THAT IS SET AS SUPERVISED, THIS CONDITION WILL BE DISPLAYED. THE RECEIVER
CAN BE SET FOR TWO OR EIGHT HOURS OF MISSING STATUS TRANSMISSIONS
BEFORE THE CONDITION OCCURS. DISPLAY WILL CLEAR THE NEXT TIME THE
PANEL IS ARMED.
7"
MOUNTING
5"
PATTERN
ATTACH CASE WITH
TWO SCREWS IN
KEYHOLE SLOTS,
THEN SECURE CASE
WITH TWO BOTTOM
SCREWS
Large
metal
appliance
(refrig.)
ZN1 COM ZN2 ZN3 COM ZN4 ZN5 COM ZN6 ZN7 COM ZN8 LB STS COM TMP TST ARM
1 2 3 4 5 6 7 8 9 1011121314151617181920
SXR-64A TERMINALS
USE SCREWS AND ANCHORS TO
MOUNT THE RECEIVER
5"
OUTPUTS PROGRAMMED
FOR NORMALLY OPEN
END-OF-LINE
RESISTORS
ALARM CONTROL PANEL
ZONE 8
COMMON
ZONE 7
ZONE 6
COMMON
ZONE 5
ZONE 4
COMMON
ZONE 3
ZONE 2
COMMON
ZONE 1
AUXILIARY
POWER
ARMED
OUTPUT
UP & DOWN BUTTONS
PRESS EITHER TO ENTER
PROGRAM MODE, UP
INCREASES AND DOWN
TERMINAL BLOCK
CONNECTIONS FOR ZONE AND
SUPERVISORY OUTPUTS,
POWER AND ARMED INPUTS
USE LOCAL
WHIP ANTENNA
(SUPPLIED)
DECREASES VALUE DISPLAYED
PRESS TOGETHER TO EXIT
PROGRAM MODE
WIRING KNOCKOUTS
FOR WIRING CONDUIT
CONNECTION
ADVANCE BUTTON
USED DURING PROGRAMMING
TO CHANGE ZONE NUMBERS
AND SELECT FUNCTIONS
- OR -
USE THE
MODEL EXA-1000
REMOTE ANTENNA
(OPTIONAL)
CONNECT ANTENNA
COAX DIRECTLY OR
USE UP TO 25 FEET
OF RG-59 COAX AS
AN EXTENSION
SET CHANNEL AND
SYSTEM SWITCH TO
ANY UNIQUE CODE
MODEL ST
MODEL ST-23A
CHANNEL
SWITCH
8
WHEN UPGRADING AN SS-32,
SSR-32, OR SXR-64 INSTALLATION,
THE TRANSMITTER SWITCH
SETTINGS CAN REMAIN THE SAME
EACH S1 FORMAT
TRANSMITTER MUST
BE SET TO A DIFFERENT
CODE
CHANNEL
SWITCH
SYSTEM
SWITCH
ST-23A NOTE: SET
SYSTEM SWITCH #1
TO OFF
MODEL ST-1
STATUS
JUMPER
RESTORE
JUMPER
SYSTEM
SWITCH
ST-1 & 50S40A NOTE: SET SXR-64A TRANSMITTER OPTION "A"
TO "ON" FOR THE CHANNEL THE TRANSMITTER IS PROGRAMMED TO.
TRANSMISSIONS WILL CAUSE A DOUBLE ZONE CLOSURE
CUT ST-1 JUMPERS
TO ENABLE STATUS
& RESTORE SIGNALS
OTHERWISE, THE LONG ALARM AND RESTORE
MODEL 50S40A
CHANNEL
SWITCH
CHANNEL
SWITCH
SYSTEM
SWITCH
SYSTEM
SWITCH
ENTERING SINGLE-CHANNEL TRANSMITTERS ENTERING MULTI-BUTTON TRANSMITTERS SETTING TRANSMITTER OPTIONS
NOTE: EACH MULTI-BUTTON TRANSMITTER USES ONE RECEIVER
CHANNEL AND A DIFFERENT OUTPUT ZONE FOR EACH BUTTTON
WITH THE PANEL DISARMED, PRESS [UP] OR [DOWN]
UNTIL THE DESIRED RECEIVER CHANNEL NUMBER
FOR THE MULTI-BUTTON TRANSMITTER IS DISPLAYED
RECEIVER CHANNEL NUMBER (40 SHOWN)
ZONE NUMBER (1 SHOWN)
ZONE
MEMORY LIGHT WILL BE OFF IF THE RECEIVER
CHANNEL IS VACANT (ONLY A VACANT RECEIVER
CHANNEL CAN ACCEPT A TRANSMITTER)
PRESS [ADVANCE] UNTIL THE DESIRED OUTPUT
ZONE NUMBER (1-8) FOR A TRANSMITTER BUTTON
IS DISPLAYED
RECEIVER CHANNEL NUMBER (40 SHOWN)
ZONE NUMBER (5 SHOWN)
ZONE
PRESS [MEMORY]
MEMORY LIGHT WILL BLINK, SHOWING THAT THE
RECEIVER IS READY TO ACCEPT THE TRANSMITTER
BUTTON
PRESS THE DESIRED TRANSMITTER BUTTON (TO
CREATE A DOUBLE-BUTTON LOCKOUT TRANSMITTER,
PRESS TWO BUTTONS AT THE SAME TIME)
MEMORY LIGHT WILL GO ON, SHOWING THAT THE
BUTTON WAS PROGRAMMED
REPEAT ZONE SELECTION TO PROGRAM ADDITIONAL
BUTTONS ON THE TRANSMITTER
CHANNEL
CHANNEL
OR
ZONE
OPTION
WITH THE PANEL DISARMED, PRESS [UP] OR
[DOWN] UNTIL THE DESIRED RECEIVER
CHANNEL NUMBER IS DISPLAYED
RECEIVER CHANNEL NUMBER (64 SHOWN)
ZONE NUMBER (8 SHOWN)
(FOR MULTI-BUTTON TRANSMITTERS, THE FIRST ZONE
NUMBER ENTERED IS DISPLAYED)
PRESS [ADVANCE] UNTIL THE DESIRED OPTION
LETTER (A-d) IS DISPLAYED
(LETTERS ARE DISPLAYED BETWEEN "8" AND "1")
CONFIGURATION OPTION DISPLAYED
(CHANNEL 64, OPTION "b" SHOWN)
FOLLOW THE TABLE BELOW AND USE THE [MEMORY]
BUTTON AND MEMORY LIGHT TO SELECT OPTIONS
FACTORY DEFAULT SETTINGS
OPTION
MEMORY LIGHT
OFF
AUTO-RESTORE TX
(PIR & PORTABLES)
NO TX STATUS
REPORTS
TX USES ENTRY &
EXIT DELAYS
UNARMED ALARM
MEMORY FOR TX
SELF-RESTORE TX
(DOORS & WINDOWS)
TX MAKES STATUS
REPORTS
TRANSMITTER
IS INSTANT
ALARM MEMORY
ONLY WHEN ARMED
OR
CHANNEL ZONE
CHANNEL ZONE
NOTE: ARMING THE CONTROL PANEL ANYTIME
DURING PROGRAMMING WILL CAUSE THE SXR-64A TO
EXIT PROGRAM MODE AND RETURN TO RUN MODE
WITH THE PANEL DISARMED, PRESS [UP] OR [DOWN]
UNTIL THE DESIRED RECEIVER CHANNEL
NUMBER (1-64) IS DISPLAYED
RECEIVER CHANNEL NUMBER (64 SHOWN)
ZONE NUMBER (1 SHOWN)
MEMORY LIGHT WILL BE OFF IF THE RECEIVER
CHANNEL IS VACANT (ONLY A VACANT RECEIVER
CHANNEL CAN ACCEPT A TRANSMITTER)
PRESS [ADVANCE] TO SELECT THE OUTPUT ZONE
NUMBER (1-8) FOR THE DISPLAYED
RECEIVER CHANNEL NUMBER
RECEIVER CHANNEL NUMBER (64 SHOWN)
ZONE NUMBER (3 SHOWN)
PRESS [MEMORY]
MEMORY LIGHT WILL BLINK, SHOWING THAT THE
RECEIVER IS READY TO ACCEPT A TRANSMITTER
ACTIVATE THE TRANSMITTER
THE MEMORY LIGHT WILL GO ON, SHOWING
THAT THE TRANSMITTER WAS ENTERED AND
THE RECEIVER'S DISPLAYED CHANNEL IS OCCUPIED
OR
CHANNEL
CHANNEL
ERASING SINGLE-CHANNEL TRANSMITTERS ERASING MULTI-BUTTON TRANSMITTERS SETTING RECEIVER OPTIONS
WITH THE PANEL DISARMED,
PRESS [UP] OR [DOWN] UNTIL "Fn" IS DISPLAYED
("Fn" IS BETWEEN "1" AND "64")
"Fn" DISPLAYED (RECEIVER OPTIONS FUNCTIONS)
PRESS [ADVANCE] UNTIL THE DESIRED FUNCTION
LETTER (1-d) IS DISPLAYED
CONFIGURATION OPTION DISPLAYED
(FUNCTION "b" SHOWN)
OR
CHANNEL ZONE
WITH THE PANEL DISARMED, PRESS [UP] OR [DOWN]
TO DISPLAY THE RECEIVER CHANNEL NUMBER WITH
THE SINGLE-CHANNEL TRANSMITTER TO ERASE
RECEIVER CHANNEL NUMBER (64 SHOWN)
IGNORE ZONE NUMBER (3 SHOWN)
MEMORY LIGHT WILL BE ON, SHOWING THAT THE
RECEIVER CHANNEL IS OCCUPIED
OR
CHANNEL ZONE
WITH THE PANEL DISARMED, PRESS [UP] OR [DOWN]
TO DISPLAY THE RECEIVER CHANNEL NUMBER WITH
THE MULTI-BUTTON TRANSMITTER TO ERASE
RECEIVER CHANNEL NUMBER (40 SHOWN)
ZONE NUMBER (5 SHOWN)
(THE FIRST ZONE NUMBER ENTERED FOR THE
MULTI-BUTTON TRANSMITTER IS DISPLAYED)
MEMORY LIGHT WILL BE ON, SHOWING THAT THE
RECEIVER CHANNEL IS OCCUPIED WITH A
TRANSMITTER BUTTON LINKED TO THAT ZONE
PRESS [MEMORY]
OR
FUNCTION
FUNCTION OPTION
★
MEMORY LIGHT
ON
★
★
★
★
FUNCTION
OR
PRESS [MEMORY]
MEMORY LIGHT WILL BLINK, SHOWING THAT THE
RECEIVER IS READY TO ERASE A TRANSMITTER
FROM THE DISPLAYED RECEIVER CHANNEL
PRESS [MEMORY] AGAIN
MEMORY LIGHT WILL GO OFF, SHOWING
THAT THE TRANSMITTER HAS BEEN ERASED
AND THAT THE RECEIVER'S CHANNEL IS VACANT
CHANNEL ZONE
MEMORY LIGHT WILL BLINK, SHOWING THAT THE
RECEIVER IS READY TO ERASE THE TRANSMITTER
BUTTON FROM THE RECEIVER'S CHANNEL AND ZONE
PRESS [MEMORY] AGAIN
MEMORY LIGHT WILL GO OFF, SHOWING THAT THE
TRANSMITTER BUTTON HAS BEEN ERASED
PRESS [ADVANCE] UNITL THE NEXT ZONE NUMBER
USED WITH THE SAME MULTI-BUTTON TRANSMITTER
IS DISPLAYED
RECEIVER CHANNEL NUMBER (40 SHOWN)
ZONE NUMBER (6 SHOWN)
REPEAT TO ERASE ANY ADDITIONAL BUTTONS THAT
WERE ENTERED FOR THAT TRANSMITTER
Fn #
MEMORY LIGHT
OFF
ARMED WHEN
ARM=GROUND
TBD
DISPLAY BLANK
WHEN ARMED
STATUS ALERTS
AFTER 2 HOURS
OUTPUTS
NORM. CLOSED
ONE OF THE
OTHER DELAYS
ONE OF THE
OTHER DELAYS
FOLLOW THE TABLE AND USE THE [MEMORY] BUTTON
AND MEMORY LIGHT TO SELECT FUNCTION OPTIONS
FACTORY DEFAULT SETTINGS
MEMORY LIGHT
ARMED WHEN
ARM=VOLTAGE
TBD
DISPLAY ON AT
ALL TIMES
STATUS ALERTS
AFTER 8 HOURS
OUTPUTS
NORMALLY OPEN
ENTRY DELAY
0 SECONDS
ENTRY DELAY
★
20 SECONDS
ON
Fn #
★
★
★
★
★
★
ONE OF THE
OTHER DELAYS
ONE OF THE
OTHER DELAYS
ONE OF THE
OTHER DELAYS
ONE OF THE
OTHER DELAYS
ONE OF THE
OTHER DELAYS
ONE OF THE
OTHER DELAYS
SET EXIT AND ENTRY DELAYS A LITTLE LONGER
THAN THE CONTROL PANEL'S DELAYS
TRANSMITTER COUNT VERIFYING TRANSMITTERS SYSTEM TESTING
WITH THE PANEL DISARMED,
PRESS [UP] OR [DOWN] UNTIL "Fn" IS DISPLAYED
("Fn" IS BETWEEN "1" AND "64")
"Fn" DISPLAYED (RECEIVER OPTIONS FUNCTION)
PRESS [ADVANCE] UNTIL THE DISPLAY SHOWS
THE OPTION "0"
OR
FUNCTION
WITH THE PANEL DISARMED,
PRESS [UP] OR [DOWN] UNTIL "Fn" IS DISPLAYED
("Fn" IS BETWEEN "1" AND "64")
"Fn" DISPLAYED (RECEIVER OPTIONS FUNCTION)
PRESS [ADVANCE] UNTIL THE DISPLAY SHOWS
THE OPTION "E"
TRANSMITTER
CONDITION
WITH THE PANEL DISARMED, OPEN A PROTECTED
DOOR OR WINDOW
THE CHANNEL NUMBER AND "O" SHOULD BE
DISPLAYED (CHANNEL 64, OPEN CONDITION SHOWN)
CLOSE THE PROTECTED DOOR OR WINDOW
★
MEMORY LIGHT
OFF
MEMORY LIGHT
ENTRY DELAY
★
40 SECONDS
ENTRY DELAY
★
60 SECONDS
EXIT DELAY
0 SECONDS
EXIT DELAY
★
20 SECONDS
EXIT DELAY
★
40 SECONDS
EXIT DELAY
★
60 SECONDS
ON
★
RECEIVER OPTION "FUNCTION 0"
FUNCTION OPTION
PRESS [MEMORY]
DISPLAY SHOWS TOTAL NUMBER OF TRANSMITTERS
IN MEMORY FOR 10 SECONDS
# OF TXS
NOTE:
PRESSING [UP] AND [DOWN] TOGETHER ANYTIME
DURING PROGRAMMING WILL CAUSE THE SXR-64A TO
EXIT PROGRAM MODE AND RETURN TO RUN MODE
FUNCTION OPTION
CHANNEL ZONE
RECEIVER OPTION "FUNCTION E"
PRESS AND RELEASE [MEMORY] THEN WAIT 5 SECONDS
DISPLAY SCROLLS THROUGH EACH CHANNEL AND
LINKED ZONE. VERIFY THAT EACH CHANNEL IS LINKED
TO THE CORRECT ZONE. (THE FIRST ZONE NUMBER
ENTERED FOR A MULTI-BUTTON TRANSMITTER IS
DISPLAYED)
ACTIVATE EACH TRANSMITTER. WHEN THE RECEIVER
DECODES THE TRANSMITTER, IT WILL BE REMOVED
FROM THE DISPLAY. CONTINUE TESTING UNTIL NO
TRANSMITTERS REMAIN ON THE DISPLAY. PRESS
THE [MEMORY] BUTTON OR WAIT 10 MINUTES TO END
THE TEST.
TRANSMITTER
TRANSMITTER
CONDITION
CONDITION
THE "O" SHOULD DISAPPEAR WHEN THE TRANSMITTER
RESTORES. DASHES WILL SHOW IF ALL PORTALS
ARE CLOSED.
ARM THE CONTROL PANEL THEN OPEN A PROTECTED
DOOR OR WINDOW (AFTER ANY DELAYS)
DISPLAY SHOULD SHOW AN "F" CONDITION FOR THE
FIRST ALARM IN
OPEN ADDITIONAL PROTECTED PORTALS. DISPLAY
SHOULD SHOW AN "A" FOR EACH ADDITIONAL ALARM
SIGNAL SENT. ALARM MEMORY WILL CLEAR WHEN
THE CONTROL PANEL IS DISARMED AND REARMED.
HOOKUP: MOOSE Z1100 & CADDX RANGER 9000 HOOKUP: C&K 236 & NAPCO MA1000 LINEAR LIMITED WARRANTY
(ZONES PROGRAMMED
NORMALLY CLOSED)
ZN1 COM ZN2 ZN3 COM ZN4 ZN5 COM ZN6 ZN7 COM ZN8 LB STS COM TMP TST ARM
1 2 3 4 5 6 7 8 9 1011121314151617181920
2.2K EOL
RESISTORS
ZN11COM2ZN23ZN34COM5ZN46ZN57COM8ZN6
SXR-64A TERMINALS
ZN710COM11ZN8
9
12
MOOSE Z1100
(ZONES PROGRAMMED
NORMALLY CLOSED)
ZN1 COM ZN2 ZN3 COM ZN4 ZN5 COM ZN6 ZN7 COM ZN8 LB STS COM TMP TST ARM
1 2 3 4 5 6 7 8 9 1011121314151617181920
3.3K EOL
RESISTORS
ZN11COM2ZN23ZN34COM5ZN46ZN57COM8ZN6
SXR-64A TERMINALS
ZN710COM11ZN812ZN915ZN1017COM16ZN11
9
CADDX RANGER 9000
28 29
AUX
POWER
18
(PROGRAMMED FOR
VOLTAGE WHEN ARMED)
8
J16
(PROGRAMMED FOR
GROUND WHEN ARMED)
1234
AUX
14 13
OUT
AUX
POWER
(ZONES PROGRAMMED
NORMALLY CLOSED)
ZN1 COM ZN2 ZN3 COM ZN4 ZN5 COM ZN6 ZN7 COM ZN8 LB STS COM TMP TST ARM
1 2 3 4 5 6 7 8 9101112131415161718 19 20
2.2K EOL
RESISTORS
Z1CZ2 Z3CZ4 Z5CZ6
C&K 236
(ZONES PROGRAMMED
NORMALLY CLOSED)
ZN1 COM ZN2 ZN3 COM ZN4 ZN5 COM ZN6 ZN7 COM ZN8 LB STS COM TMP TST ARM
1 2 3 4 5 6 7 8 9101112131415161718 19 20
2.2K EOL
RESISTORS
ZN115COM14ZN216ZN317ZN419ZN520COM18ZN6
SXR-64A TERMINALS
C
AUX
AUX
POWER
SXR-64A TERMINALS
21
NAPCO MA1000e
56
AUX
POWER
(PROGRAMMED FOR
VOLTAGE WHEN ARMED)
NOTE: THIS PANEL DOES NOT
SUPPLY AN ARMED SIGNAL.
USE A PUSHBUTTON TO
RESET THE ALARM MEMORY
WHEN THE PANEL IS ARMED.
SET SXR-64A DELAYS TO "0"
(PROGRAMMED FOR
GROUND WHEN ARMED)
E3 PGM
This Linear product is warranted against defects in material and workmanship for twelve (12)
months. The Warranty Expiration Date is labeled on the product. This warranty extends only
to wholesale customers who buy direct from Linear or through Linear’s normal distribution
channels. Linear does not warrant this product to consumers. Consumers should inquire from
their selling dealer as to the nature of the dealer’s warranty, if any. There are no obligations or
liabilities on the part of Linear Corporation for consequential damages arising out of or in
connection with use or performance of this product or other indirect damages with respect
RESET
to loss of property, revenue, or profi t, or cost of removal, installation, or reinstallation.
All implied warranties, including implied warranties for merchantability and implied warranties
for fi tness, are valid only until Warranty Expiration Date as labeled on the product. This Linear
Corporation Warranty is in lieu of all other warranties express or implied.
All products returned for warranty service require a Return Product Authorization Number (RPA#).
Contact Linear Technical Services at 1-800-421-1587 for an RPA# and other important details.
IMPORTANT !!!
Linear radio controls provide a reliable communications link and fi ll an important need in portable
wireless signalling. However, there are some limitations which must be observed.
✶ For U.S. installations only: The radios are required to comply with FCC Rules and Regulations
as Part 15 devices. As such, they have limited transmitter power and therefore limited range.
✶ A receiver cannot respond to more than one transmitted signal at a time and may be blocked
by radio signals that occur on or near their operating frequencies, regardless of code
settings.
✶ Changes or modifi cations to the device may void FCC compliance.
✶ Infrequently used radio links should be tested regularly to protect against undetected
interference or fault.
✶ A general knowledge of radio and its vagaries should be gained prior to acting as a wholesale
distributor or dealer, and these facts should be communicated to the ultimate users.
Copyright © 2003 Linear Corporation 220822 A