Linear SXR-64A User Manual

SXR-64A
Supervised Wireless Receiver and Zone Expander
Installation Instructions
(760) 438-7000 • FAX (760) 438-7043
USA & Canada (800) 421-1587 & (800) 392-0123
Toll Free FAX (800) 468-1340
www.linearcorp.com
SYSTEM OVERVIEW CONDITION DISPLAYS COMPONENT LOCATIONS
TYPICAL TRANSMITTERS
TX-91 TX-92 TX-94 T-90D TMD-90 TSD-90A
ST-23A LMT-1/303 MPX/303
UP TO 64 TRANSMITTERS CAN BE USED
INTRODUCTION
The Model SXR-64A is a 64-channel, 12-zone, supervised wireless receiver/ annunciator designed for use in residential or commercial security systems. Housed in a rugged metal enclosure, the SXR-64A connects to a hardwired alarm control panel adding wireless capability to the panel. The SXR-64A receives signals from a variety of security transmitters then processes, displays and transfers the signal to the hardwired alarm control panel. Six unique conditions for each transmitter channel can be shown on the unit’s display. Conditions such as “Open Portal”, “Transmitter Low Battery”, “Transmitter Tamper” and “First Alarm In” show the status of each transmitter in the system. Valuable features such as Alarm Memory and Transmitter Status allow for quick system diagnosis and troubleshooting. The receiver’s eight alarm zones and four supervisory zones provide a fl exible interface to the alarm control panel. Any or all of the zones can be used. All of the solid state zone outputs can be either normally open or normally closed electrical confi guration and can switch up to 100 mA @ 24 VDC. An easy programming interface using four pushbuttons lets the installer quickly setup the system. The UP, DOWN, ADVANCE and MEMORY buttons are located inside the receiver case and are used for transmitter and system programming. An on-board, high-gain, superheterodyne radio receiver gives the SXR-64A excellent reception. The MODE indicator shows RF activity. The local whip antenna (supplied) or remote external antenna (Model EXA-1000) connects to the receiver through a standard type “F” connector. The SXR-64A decodes Linear’s SX, S1, and MegaCode™ format transmitters. The SXR-64A can be used as a direct replacement for Linear’s SS-32, SSR-32, & SXR-64 receivers with an installation bonus of being able to use up to 64 transmitters in the system. Power for the SXR-64A is provided from the alarm control panel. To control the alarm memory, reset tamper and status alert conditions, an armed input on the receiver connects to an armed output from the control panel.
CONDITIONS FOR ALL TRANSMITTERS
ROTATE ON THE DISPLAY
OPEN PORTAL
ALL TRANSMITTERS WILL CAUSE THIS CONDITION WHEN AN ALARM SIGNAL IS SENT. THE CONDITION WILL REMAIN UNTIL A RESTORE SIGNAL IS SENT, UNLESS THE TRANSMITTER IS SET AS "AUTO RESTORE". THE CHANNEL'S ZONE OUTPUT WILL BE FAULTED WHEN THIS CONDITION IS DISPLAYED.
FIRST ALARM IN
WHEN THE PANEL IS ARMED, THE FIRST ALARM SIGNAL SENT WILL CAUSE THIS CONDITION. IF THE CHANNEL IS SET AS "DELAYED", THIS CONDITION WILL OCCUR AFTER ANY DELAYS IF THE PANEL IS NOT DISARMED. DISPLAY WILL CLEAR THE NEXT TIME THE PANEL IS RE-ARMED.
ADDITIONAL ALARMS IN
WHEN THE PANEL IS ARMED, ADDITIONAL ALARM SIGNALS SENT WILL CAUSE THIS CONDITION. IF THE CHANNEL IS SET AS "DELAYED", THIS CONDITION WILL OCCUR AFTER ANY DELAYS IF THE PANEL IS NOT DISARMED. DISPLAY WILL CLEAR THE NEXT TIME THE PANEL IS RE-ARMED.
TRANSMITTER LOW BATTERY
ANY TRANSMITTER THAT CAN SEND A LOW BATTERY SIGNAL WILL CAUSE THIS CONDITION WHEN ITS BATTERY IS LOW. DISPLAY WILL REMAIN UNTIL A SIGNAL FROM THE SAME TRANSMITTER WITH A GOOD BATTERY IS SENT.
FEATURES
64 Programmable Transmitter Channels
8 Alarm Zones
4 Supervisory Zones
Rugged Metal Enclosure
Six Condition Displays for Each Transmitter
Alarm Memory with First-Alarm-In
Automatic Supervised Operation
Transmitter Contact State Monitoring
Transmitter Tamper Monitoring
Transmitter Low Battery Monitoring
Transmitter Status Report Monitoring
Easy Installer Programming Interface
High-gain Superheterodyne Receiver
Receiver Automatic Gain Control
Antenna Connector
Decodes 303.875 MHz SX, S1, & MegaCode™ Format Transmitters
Optional Display Blanking while Armed
RF Activity Indicator
Positive or Negative Armed Input
ANTENNA CONNECTOR
TYPE "F" ANTENNA CONNECTOR FOR CONNECTION TO LOCAL OR REMOTE ANTENNA THROUGH RG-59 COAX
LIGHTS WHEN UNIT IS IN PROGRAM MODE, FLASHES WHEN RF IS RECEIVED IN RUN MODE
TEST POINTS
AUDIO TEST POINTS FOR LISTENING TO RADIO INPUT WITH BUTTSET
MODE LIGHT
TRANSMITTER DISPLAY
SHOWS THE TRANSMITTER'S CHANNEL NUMBER AND IS USED DURING PROGRAMMING
SHOWS THE TRANSMITTER'S CONDITION AND IS USED DURING PROGRAMMING
CONDITION DISPLAY
MEMORY LIGHT
LIGHTS DURING PROGRAM MODE TO SHOW WHEN A TRANSMITTER HAS BEEN ENTERED OR AN OPTION HAS BEEN SELECTED, LIGHTS DURING RUN MODE WHEN SYSTEM IS ARMED, BLINKS DURING EXIT DELAY
MEMORY BUTTON
USED DURING PROGRAMMING TO SELECT OPTIONS AND ENTER TRANSMITTERS
SXR-64A RECEIVER ALARM CONTROL PANEL
INSTALLATION TIPS MOUNTING UNIT ANTENNA INSTALLATION
90% - 100%
OF FULL POWER
CONSTRUCTION
MATERIALS WILL
EFFECT RADIO RANGE
WALLBOARD AND
WOOD STUDS
RCVR
BASEMENT
MOUNT RECEIVER OR ANTENNA AS HIGH ABOVE
TRANSMITTER
MOUNTING WILL
EFFECT RADIO
RANGE
RIGHT
EARTH LEVEL AS POSSIBLE
RIGHT
CENTRALLY LOCATE RECEIVER
OR ANTENNA
TX
DOOR
Min. 3 ft.
RIGHT
RECEIVER (ANTENNA)
LOCATION EFFECTS
RADIO RANGE
Concrete
slab floor
65% - 95%
OF FULL POWER
LIGHT CONCRETE
OR BRICK
LOCATING A RECEIVER OR ANTENNA BELOW
TRANSMITTERS AT THE OTHER END OF
Less than
DOOR
3 ft.
above
slab
TX
WRONG!
OF FULL POWER
CONCRETE WITH STEEL
REINFORCEMENT OR
METAL LATH AND PLASTER
BASEMENT
WRONG!
EARTH LEVEL WILL IMPAIR RANGE
WRONG!
HOUSE MIGHT BE TOO FAR AWAY
Wall
Concrete
slab floor
TX
10% - 70%
RCVR
WRONG!
TERMINAL BLOCK DETAILS TYPICAL CONTROL PANEL CONNECTION S1 FORMAT TRANSMITTER DETAILS
ZONE OUTPUTS
TEST OUTPUT
SXR-64A TERMINALS
FOR CONNECTION TO THE ALARM CONTROL PANEL'S AUXILIARY POWER OUTPUT. POWER INPUT CAN BE FROM 11-16 VDC ONLY
FOR CONNECTION TO THE ALARM CONTROL PANEL'S ARMED OUTPUT. THE ARMED INPUT CAN BE SET FOR ARMED-POSITIVE OR ARMED-NEGATIVE POLARITY.
POWER INPUT
ARMED INPUT
1 2 3 4 5 6 7 8 9 1011121314151617181920
ZN1 COM ZN2 ZN3 COM ZN4 ZN5 COM ZN6 ZN7 COM ZN8 LB STS COM TMP TST ARM
FOR CONNECTION TO ALARM ZONE INPUTS ON THE ALARM CONTROL PANEL. ZONE OUTPUT WILL ACTIVATE WHEN ANY TRANSMITTER CHANNEL PROGRAMMED FOR THAT ZONE IS IN THE FAULTED (ALARM/OPEN) CONDITION ("O" DISPLAYED ON THE CONDITION DISPLAY).
FOR CONNECTION TO A TROUBLE ZONE ON THE ALARM CONTROL PANEL. OUTPUT WILL ACTIVATE WHEN ANY TRANSMITTER CHANNEL DISPLAYS AN "L" ON THE CONDITION DISPLAY.
FOR CONNECTION TO A TROUBLE ZONE ON THE ALARM CONTROL PANEL. OUTPUT WILL ACTIVATE WHEN ANY TRANSMITTER CHANNEL DISPLAYS AN "S" ON THE CONDITION DISPLAY.
FOR CONNECTION TO A TROUBLE ZONE ON THE ALARM CONTROL PANEL. OUTPUT WILL ACTIVATE WHEN ANY TRANSMITTER CHANNEL DISPLAYS A "P" ON THE CONDITION DISPLAY OR WHEN ANY PROGRAMMING BUTTON IS PRESSED WHILE THE SYSTEM IS ARMED.
FOR CONNECTION TO A TEST ZONE ON THE ALARM CONTROL PANEL. OUTPUT WILL ACTIVATE WHEN ANY TRANSMITTER THAT CAN SEND A TEST SIGNAL HAS ITS TEST BUTTON PRESSED.
NOTES:
1. ALL COM TERMINALS ARE COMMON GROUND AND CONNECTED TOGETHER.
2. ALL OUTPUTS CAN BE PROGRAMMED FOR NORMALLY OPEN OR NORMALLY CLOSED OPERATION. EACH OUTPUT RETURNS TO ANY COM TERMINAL.
3. EACH OUTPUT CAN SWITCH UP TO 100 mA @ 24 VDC MAXIMUM.
LOW BATTERY OUTPUT
STATUS OUTPUT
TAMPER OUTPUT
TRANSMITTER TAMPER
ANY TRANSMITTER THAT CAN SEND A TAMPER SIGNAL WILL CAUSE THIS CONDITION WHEN IT IS TAMPERED. DISPLAY WILL CLEAR THE NEXT TIME THE PANEL IS ARMED.
TRANSMITTER STATUS ALERT
IF THE RECEIVER DOES NOT RECEIVE STATUS SIGNALS FROM A TRANSMITTER THAT IS SET AS SUPERVISED, THIS CONDITION WILL BE DISPLAYED. THE RECEIVER CAN BE SET FOR TWO OR EIGHT HOURS OF MISSING STATUS TRANSMISSIONS BEFORE THE CONDITION OCCURS. DISPLAY WILL CLEAR THE NEXT TIME THE PANEL IS ARMED.
7"
MOUNTING
5"
PATTERN
ATTACH CASE WITH TWO SCREWS IN KEYHOLE SLOTS, THEN SECURE CASE WITH TWO BOTTOM SCREWS
Large metal
appliance
(refrig.)
ZN1 COM ZN2 ZN3 COM ZN4 ZN5 COM ZN6 ZN7 COM ZN8 LB STS COM TMP TST ARM
1 2 3 4 5 6 7 8 9 1011121314151617181920
SXR-64A TERMINALS
USE SCREWS AND ANCHORS TO MOUNT THE RECEIVER
5"
OUTPUTS PROGRAMMED FOR NORMALLY OPEN
END-OF-LINE RESISTORS
ALARM CONTROL PANEL
ZONE 8
COMMON
ZONE 7
ZONE 6
COMMON
ZONE 5
ZONE 4
COMMON
ZONE 3
ZONE 2
COMMON
ZONE 1
AUXILIARY POWER
ARMED OUTPUT
UP & DOWN BUTTONS
PRESS EITHER TO ENTER PROGRAM MODE, UP INCREASES AND DOWN
TERMINAL BLOCK
CONNECTIONS FOR ZONE AND SUPERVISORY OUTPUTS, POWER AND ARMED INPUTS
USE LOCAL WHIP ANTENNA (SUPPLIED)
DECREASES VALUE DISPLAYED PRESS TOGETHER TO EXIT PROGRAM MODE
WIRING KNOCKOUTS
FOR WIRING CONDUIT CONNECTION
ADVANCE BUTTON
USED DURING PROGRAMMING TO CHANGE ZONE NUMBERS AND SELECT FUNCTIONS
- OR -
USE THE MODEL EXA-1000 REMOTE ANTENNA (OPTIONAL)
CONNECT ANTENNA COAX DIRECTLY OR USE UP TO 25 FEET OF RG-59 COAX AS AN EXTENSION
SET CHANNEL AND SYSTEM SWITCH TO ANY UNIQUE CODE
MODEL ST
MODEL ST-23A
CHANNEL
SWITCH
8
WHEN UPGRADING AN SS-32, SSR-32, OR SXR-64 INSTALLATION, THE TRANSMITTER SWITCH SETTINGS CAN REMAIN THE SAME
EACH S1 FORMAT TRANSMITTER MUST BE SET TO A DIFFERENT CODE
CHANNEL
SWITCH
SYSTEM SWITCH
ST-23A NOTE: SET SYSTEM SWITCH #1 TO OFF
MODEL ST-1
STATUS JUMPER
RESTORE JUMPER
SYSTEM SWITCH
ST-1 & 50S40A NOTE: SET SXR-64A TRANSMITTER OPTION "A"
TO "ON" FOR THE CHANNEL THE TRANSMITTER IS PROGRAMMED TO.
TRANSMISSIONS WILL CAUSE A DOUBLE ZONE CLOSURE
CUT ST-1 JUMPERS
TO ENABLE STATUS
& RESTORE SIGNALS
OTHERWISE, THE LONG ALARM AND RESTORE
MODEL 50S40A
CHANNEL
SWITCH
CHANNEL
SWITCH
SYSTEM SWITCH
SYSTEM SWITCH
ENTERING SINGLE-CHANNEL TRANSMITTERS ENTERING MULTI-BUTTON TRANSMITTERS SETTING TRANSMITTER OPTIONS
NOTE: EACH MULTI-BUTTON TRANSMITTER USES ONE RECEIVER CHANNEL AND A DIFFERENT OUTPUT ZONE FOR EACH BUTTTON
WITH THE PANEL DISARMED, PRESS [UP] OR [DOWN] UNTIL THE DESIRED RECEIVER CHANNEL NUMBER FOR THE MULTI-BUTTON TRANSMITTER IS DISPLAYED
RECEIVER CHANNEL NUMBER (40 SHOWN) ZONE NUMBER (1 SHOWN)
ZONE
MEMORY LIGHT WILL BE OFF IF THE RECEIVER CHANNEL IS VACANT (ONLY A VACANT RECEIVER CHANNEL CAN ACCEPT A TRANSMITTER)
PRESS [ADVANCE] UNTIL THE DESIRED OUTPUT ZONE NUMBER (1-8) FOR A TRANSMITTER BUTTON IS DISPLAYED
RECEIVER CHANNEL NUMBER (40 SHOWN) ZONE NUMBER (5 SHOWN)
ZONE
PRESS [MEMORY]
MEMORY LIGHT WILL BLINK, SHOWING THAT THE RECEIVER IS READY TO ACCEPT THE TRANSMITTER BUTTON
PRESS THE DESIRED TRANSMITTER BUTTON (TO CREATE A DOUBLE-BUTTON LOCKOUT TRANSMITTER, PRESS TWO BUTTONS AT THE SAME TIME)
MEMORY LIGHT WILL GO ON, SHOWING THAT THE BUTTON WAS PROGRAMMED
REPEAT ZONE SELECTION TO PROGRAM ADDITIONAL BUTTONS ON THE TRANSMITTER
CHANNEL
CHANNEL
OR
ZONE
OPTION
WITH THE PANEL DISARMED, PRESS [UP] OR [DOWN] UNTIL THE DESIRED RECEIVER CHANNEL NUMBER IS DISPLAYED
RECEIVER CHANNEL NUMBER (64 SHOWN) ZONE NUMBER (8 SHOWN) (FOR MULTI-BUTTON TRANSMITTERS, THE FIRST ZONE NUMBER ENTERED IS DISPLAYED)
PRESS [ADVANCE] UNTIL THE DESIRED OPTION LETTER (A-d) IS DISPLAYED (LETTERS ARE DISPLAYED BETWEEN "8" AND "1")
CONFIGURATION OPTION DISPLAYED (CHANNEL 64, OPTION "b" SHOWN)
FOLLOW THE TABLE BELOW AND USE THE [MEMORY] BUTTON AND MEMORY LIGHT TO SELECT OPTIONS
FACTORY DEFAULT SETTINGS
OPTION
MEMORY LIGHT
OFF
AUTO-RESTORE TX (PIR & PORTABLES)
NO TX STATUS REPORTS
TX USES ENTRY & EXIT DELAYS
UNARMED ALARM MEMORY FOR TX
SELF-RESTORE TX (DOORS & WINDOWS)
TX MAKES STATUS REPORTS
TRANSMITTER IS INSTANT
ALARM MEMORY ONLY WHEN ARMED
OR
CHANNEL ZONE
CHANNEL ZONE
NOTE: ARMING THE CONTROL PANEL ANYTIME
DURING PROGRAMMING WILL CAUSE THE SXR-64A TO
EXIT PROGRAM MODE AND RETURN TO RUN MODE
WITH THE PANEL DISARMED, PRESS [UP] OR [DOWN] UNTIL THE DESIRED RECEIVER CHANNEL NUMBER (1-64) IS DISPLAYED
RECEIVER CHANNEL NUMBER (64 SHOWN) ZONE NUMBER (1 SHOWN)
MEMORY LIGHT WILL BE OFF IF THE RECEIVER CHANNEL IS VACANT (ONLY A VACANT RECEIVER CHANNEL CAN ACCEPT A TRANSMITTER)
PRESS [ADVANCE] TO SELECT THE OUTPUT ZONE NUMBER (1-8) FOR THE DISPLAYED RECEIVER CHANNEL NUMBER
RECEIVER CHANNEL NUMBER (64 SHOWN) ZONE NUMBER (3 SHOWN)
PRESS [MEMORY]
MEMORY LIGHT WILL BLINK, SHOWING THAT THE RECEIVER IS READY TO ACCEPT A TRANSMITTER
ACTIVATE THE TRANSMITTER
THE MEMORY LIGHT WILL GO ON, SHOWING THAT THE TRANSMITTER WAS ENTERED AND THE RECEIVER'S DISPLAYED CHANNEL IS OCCUPIED
OR
CHANNEL
CHANNEL
ERASING SINGLE-CHANNEL TRANSMITTERS ERASING MULTI-BUTTON TRANSMITTERS SETTING RECEIVER OPTIONS
WITH THE PANEL DISARMED, PRESS [UP] OR [DOWN] UNTIL "Fn" IS DISPLAYED ("Fn" IS BETWEEN "1" AND "64")
"Fn" DISPLAYED (RECEIVER OPTIONS FUNCTIONS)
PRESS [ADVANCE] UNTIL THE DESIRED FUNCTION LETTER (1-d) IS DISPLAYED
CONFIGURATION OPTION DISPLAYED (FUNCTION "b" SHOWN)
OR
CHANNEL ZONE
WITH THE PANEL DISARMED, PRESS [UP] OR [DOWN] TO DISPLAY THE RECEIVER CHANNEL NUMBER WITH THE SINGLE-CHANNEL TRANSMITTER TO ERASE
RECEIVER CHANNEL NUMBER (64 SHOWN) IGNORE ZONE NUMBER (3 SHOWN)
MEMORY LIGHT WILL BE ON, SHOWING THAT THE RECEIVER CHANNEL IS OCCUPIED
OR
CHANNEL ZONE
WITH THE PANEL DISARMED, PRESS [UP] OR [DOWN] TO DISPLAY THE RECEIVER CHANNEL NUMBER WITH THE MULTI-BUTTON TRANSMITTER TO ERASE
RECEIVER CHANNEL NUMBER (40 SHOWN) ZONE NUMBER (5 SHOWN) (THE FIRST ZONE NUMBER ENTERED FOR THE MULTI-BUTTON TRANSMITTER IS DISPLAYED)
MEMORY LIGHT WILL BE ON, SHOWING THAT THE RECEIVER CHANNEL IS OCCUPIED WITH A TRANSMITTER BUTTON LINKED TO THAT ZONE
PRESS [MEMORY]
OR
FUNCTION
FUNCTION OPTION
MEMORY LIGHT
ON
FUNCTION
OR
PRESS [MEMORY]
MEMORY LIGHT WILL BLINK, SHOWING THAT THE RECEIVER IS READY TO ERASE A TRANSMITTER FROM THE DISPLAYED RECEIVER CHANNEL
PRESS [MEMORY] AGAIN
MEMORY LIGHT WILL GO OFF, SHOWING THAT THE TRANSMITTER HAS BEEN ERASED AND THAT THE RECEIVER'S CHANNEL IS VACANT
CHANNEL ZONE
MEMORY LIGHT WILL BLINK, SHOWING THAT THE RECEIVER IS READY TO ERASE THE TRANSMITTER BUTTON FROM THE RECEIVER'S CHANNEL AND ZONE
PRESS [MEMORY] AGAIN
MEMORY LIGHT WILL GO OFF, SHOWING THAT THE TRANSMITTER BUTTON HAS BEEN ERASED
PRESS [ADVANCE] UNITL THE NEXT ZONE NUMBER USED WITH THE SAME MULTI-BUTTON TRANSMITTER IS DISPLAYED
RECEIVER CHANNEL NUMBER (40 SHOWN) ZONE NUMBER (6 SHOWN)
REPEAT TO ERASE ANY ADDITIONAL BUTTONS THAT WERE ENTERED FOR THAT TRANSMITTER
Fn #
MEMORY LIGHT
OFF
ARMED WHEN ARM=GROUND
TBD
DISPLAY BLANK WHEN ARMED
STATUS ALERTS AFTER 2 HOURS
OUTPUTS NORM. CLOSED
ONE OF THE OTHER DELAYS
ONE OF THE OTHER DELAYS
FOLLOW THE TABLE AND USE THE [MEMORY] BUTTON AND MEMORY LIGHT TO SELECT FUNCTION OPTIONS
FACTORY DEFAULT SETTINGS
MEMORY LIGHT
ARMED WHEN ARM=VOLTAGE
TBD
DISPLAY ON AT ALL TIMES STATUS ALERTS AFTER 8 HOURS
OUTPUTS NORMALLY OPEN
ENTRY DELAY 0 SECONDS
ENTRY DELAY
20 SECONDS
ON
Fn #
ONE OF THE OTHER DELAYS
ONE OF THE OTHER DELAYS
ONE OF THE OTHER DELAYS
ONE OF THE OTHER DELAYS
ONE OF THE OTHER DELAYS ONE OF THE OTHER DELAYS
SET EXIT AND ENTRY DELAYS A LITTLE LONGER THAN THE CONTROL PANEL'S DELAYS
TRANSMITTER COUNT VERIFYING TRANSMITTERS SYSTEM TESTING
WITH THE PANEL DISARMED, PRESS [UP] OR [DOWN] UNTIL "Fn" IS DISPLAYED ("Fn" IS BETWEEN "1" AND "64")
"Fn" DISPLAYED (RECEIVER OPTIONS FUNCTION)
PRESS [ADVANCE] UNTIL THE DISPLAY SHOWS THE OPTION "0"
OR
FUNCTION
WITH THE PANEL DISARMED, PRESS [UP] OR [DOWN] UNTIL "Fn" IS DISPLAYED ("Fn" IS BETWEEN "1" AND "64")
"Fn" DISPLAYED (RECEIVER OPTIONS FUNCTION)
PRESS [ADVANCE] UNTIL THE DISPLAY SHOWS THE OPTION "E"
TRANSMITTER
CONDITION
WITH THE PANEL DISARMED, OPEN A PROTECTED DOOR OR WINDOW
THE CHANNEL NUMBER AND "O" SHOULD BE DISPLAYED (CHANNEL 64, OPEN CONDITION SHOWN)
CLOSE THE PROTECTED DOOR OR WINDOW
MEMORY LIGHT
OFF
MEMORY LIGHT
ENTRY DELAY
40 SECONDS
ENTRY DELAY
60 SECONDS
EXIT DELAY 0 SECONDS
EXIT DELAY
20 SECONDS
EXIT DELAY
40 SECONDS
EXIT DELAY
60 SECONDS
ON
RECEIVER OPTION "FUNCTION 0"
FUNCTION OPTION
PRESS [MEMORY]
DISPLAY SHOWS TOTAL NUMBER OF TRANSMITTERS IN MEMORY FOR 10 SECONDS
# OF TXS
NOTE:
PRESSING [UP] AND [DOWN] TOGETHER ANYTIME
DURING PROGRAMMING WILL CAUSE THE SXR-64A TO
EXIT PROGRAM MODE AND RETURN TO RUN MODE
FUNCTION OPTION
CHANNEL ZONE
RECEIVER OPTION "FUNCTION E"
PRESS AND RELEASE [MEMORY] THEN WAIT 5 SECONDS
DISPLAY SCROLLS THROUGH EACH CHANNEL AND LINKED ZONE. VERIFY THAT EACH CHANNEL IS LINKED TO THE CORRECT ZONE. (THE FIRST ZONE NUMBER ENTERED FOR A MULTI-BUTTON TRANSMITTER IS DISPLAYED)
ACTIVATE EACH TRANSMITTER. WHEN THE RECEIVER DECODES THE TRANSMITTER, IT WILL BE REMOVED FROM THE DISPLAY. CONTINUE TESTING UNTIL NO TRANSMITTERS REMAIN ON THE DISPLAY. PRESS THE [MEMORY] BUTTON OR WAIT 10 MINUTES TO END THE TEST.
TRANSMITTER
TRANSMITTER
CONDITION
CONDITION
THE "O" SHOULD DISAPPEAR WHEN THE TRANSMITTER RESTORES. DASHES WILL SHOW IF ALL PORTALS ARE CLOSED.
ARM THE CONTROL PANEL THEN OPEN A PROTECTED DOOR OR WINDOW (AFTER ANY DELAYS)
DISPLAY SHOULD SHOW AN "F" CONDITION FOR THE FIRST ALARM IN
OPEN ADDITIONAL PROTECTED PORTALS. DISPLAY SHOULD SHOW AN "A" FOR EACH ADDITIONAL ALARM SIGNAL SENT. ALARM MEMORY WILL CLEAR WHEN THE CONTROL PANEL IS DISARMED AND REARMED.
HOOKUP: MOOSE Z1100 & CADDX RANGER 9000 HOOKUP: C&K 236 & NAPCO MA1000 LINEAR LIMITED WARRANTY
(ZONES PROGRAMMED
NORMALLY CLOSED)
ZN1 COM ZN2 ZN3 COM ZN4 ZN5 COM ZN6 ZN7 COM ZN8 LB STS COM TMP TST ARM
1 2 3 4 5 6 7 8 9 1011121314151617181920
2.2K EOL
RESISTORS
ZN11COM2ZN23ZN34COM5ZN46ZN57COM8ZN6
SXR-64A TERMINALS
ZN710COM11ZN8
9
12
MOOSE Z1100
(ZONES PROGRAMMED
NORMALLY CLOSED)
ZN1 COM ZN2 ZN3 COM ZN4 ZN5 COM ZN6 ZN7 COM ZN8 LB STS COM TMP TST ARM
1 2 3 4 5 6 7 8 9 1011121314151617181920
3.3K EOL
RESISTORS
ZN11COM2ZN23ZN34COM5ZN46ZN57COM8ZN6
SXR-64A TERMINALS
ZN710COM11ZN812ZN915ZN1017COM16ZN11
9
CADDX RANGER 9000
28 29
AUX
POWER
18
(PROGRAMMED FOR
VOLTAGE WHEN ARMED)
8
J16
(PROGRAMMED FOR
GROUND WHEN ARMED)
1234
AUX
14 13
OUT
AUX
POWER
(ZONES PROGRAMMED
NORMALLY CLOSED)
ZN1 COM ZN2 ZN3 COM ZN4 ZN5 COM ZN6 ZN7 COM ZN8 LB STS COM TMP TST ARM
1 2 3 4 5 6 7 8 9101112131415161718 19 20
2.2K EOL
RESISTORS
Z1CZ2 Z3CZ4 Z5CZ6
C&K 236
(ZONES PROGRAMMED
NORMALLY CLOSED)
ZN1 COM ZN2 ZN3 COM ZN4 ZN5 COM ZN6 ZN7 COM ZN8 LB STS COM TMP TST ARM
1 2 3 4 5 6 7 8 9101112131415161718 19 20
2.2K EOL
RESISTORS
ZN115COM14ZN216ZN317ZN419ZN520COM18ZN6
SXR-64A TERMINALS
C
AUX
AUX
POWER
SXR-64A TERMINALS
21
NAPCO MA1000e
56
AUX
POWER
(PROGRAMMED FOR
VOLTAGE WHEN ARMED)
NOTE: THIS PANEL DOES NOT SUPPLY AN ARMED SIGNAL. USE A PUSHBUTTON TO RESET THE ALARM MEMORY WHEN THE PANEL IS ARMED. SET SXR-64A DELAYS TO "0"
(PROGRAMMED FOR
GROUND WHEN ARMED)
E3 PGM
This Linear product is warranted against defects in material and workmanship for twelve (12) months. The Warranty Expiration Date is labeled on the product. This warranty extends only to wholesale customers who buy direct from Linear or through Linear’s normal distribution channels. Linear does not warrant this product to consumers. Consumers should inquire from their selling dealer as to the nature of the dealer’s warranty, if any. There are no obligations or
liabilities on the part of Linear Corporation for consequential damages arising out of or in connection with use or performance of this product or other indirect damages with respect
RESET
to loss of property, revenue, or profi t, or cost of removal, installation, or reinstallation. All implied warranties, including implied warranties for merchantability and implied warranties for fi tness, are valid only until Warranty Expiration Date as labeled on the product. This Linear
Corporation Warranty is in lieu of all other warranties express or implied.
All products returned for warranty service require a Return Product Authorization Number (RPA#). Contact Linear Technical Services at 1-800-421-1587 for an RPA# and other important details.
IMPORTANT !!!
Linear radio controls provide a reliable communications link and fi ll an important need in portable wireless signalling. However, there are some limitations which must be observed.
For U.S. installations only: The radios are required to comply with FCC Rules and Regulations
as Part 15 devices. As such, they have limited transmitter power and therefore limited range.
A receiver cannot respond to more than one transmitted signal at a time and may be blocked
by radio signals that occur on or near their operating frequencies, regardless of code settings.
Changes or modifi cations to the device may void FCC compliance.
Infrequently used radio links should be tested regularly to protect against undetected
interference or fault.
A general knowledge of radio and its vagaries should be gained prior to acting as a wholesale
distributor or dealer, and these facts should be communicated to the ultimate users.
Copyright © 2003 Linear Corporation 220822 A
Loading...