Linear H318, H336 Quick Start Manual

®
ChannelPlus Enclosures
OpenHouse modules attach from the top
1
H290
H291
AC outlet
accessories
HC18A
18” cover
H318
18” enclosure
HC36A
36” cover
Mounting the enclosure
1. For tab mounting, install the mounting tabs
A. Select the proper slots for the wallboard thickness.
Slots A - For 3/8” wallboard Slots B - For 1/2” wallboard Slots C - For 5/8” wallboard
B. Insert mounting tab.
(Don’t worry if the tabs seem loose - they tighten up when screwed to the studs.)
2. Attach enclosure
Use the four screws provided. (The screws will force mounting tabs flat, tightening the tab.)
A C
B
A
C
16" on center
H336
36” enclosure
B
1) Hook from the top
2) Swing into place
3) Push button to lock
Telephone Master Hub (4 lines x 6 phones)
3
2
From
Expansion
Telco
R
4
T
R
3
T
R
2
T
R
1
T
ChannelPlus model H616
Telephones
Ports
RJ31X
Out
Mounting the H290/H291 AC outlet accessory
H290/H291 installs in any of 4 locations
The H290/H291 accessory brings AC power inside the H318 and H336 enclosures. The H290/H291 gives the installer a clean location to mount power adapters. Mount the H290/H291 in any corner of the enclosure using the four #6 screws provided. Installation of AC outlets should be done only by a qualified electrician.
1/2” knockouts for 120VAC
Wood
Stud
Or, when mounting without the tabs, use screws in the four slide mount slots.
1/8”
Stud
Enclosure
When mounting without using
Wallboard
the mounting tabs adjust the enclosure to protrude 1/8” beyond the wallboard surface.
Installing cables
Remove the knockouts as needed and line the holes with the grommets provided.
H272 Grommet
The H290/(H291) provides
OEM
AC ADAPTER
space for 4/(2) standard duplex receptacles. Wires should exit the H290/(H291) using the grommets provided. The grommets may be cut as shown.
Using wire ties with the OpenHouse grid
1) Fold back tip of wire tie and insert into hole
2) Push wire tie slowly into hole until tip snaps to next hole
3) Pull tip through second hole
®
4) Works horizontally too
H272
The H318 and H336 enclosures include H272 grommets. If you need more grommets, they are available as part number H272.
Remove paint shield and save.
Route cabling into enclosure.
Use H271 (not included) to
join 2 or more enclosures.
After cabling is routed, reverse paint
shield and return it to the enclosure to
protect cabling.
If H290 is installed, fold flaps on the paint shield to bend the shield over the H290 AC outlet accessory.
H271
Coupling tube
Installing the cover
An old electrician’s trick
When hanging a heavy cabinet cover, insert two nails (included) through the mounting holes on the cover. Guide the nails into the mating holes on the enclosure and let the cover hang from the nails while you attach the screws.
Grounding the cabinet
When used with model H290/H291 accessory, the grounding lug on the H290/H291 is used. Standard #10-32 grounding screws may be added to the tapped holes top or bottom.
Optional lock kit - H208
Remove knockouts on the cover to install optional lock kit H208. If an H290/H291 is used the cover must be fastened to the enclosure using the included screws (even when using the lock kit.) This is a UL requirement.
222683 B 222683 B
New features of the H318/H336
®
New tri-thread cover mounting
Home office - phone, TV, ethernet, satellite receiver, cable modem, hi-speed data Media center - phone, TV, ethernet, satellite receiver, AV modulators, hi-speed data Typical room - phone, TV, ethernet, satellite receiver
Best …
ethernet,
phone, TV, ethernet, cable modem
cable modem
Home office ­Media center - phone, TV, satellite receiver, AV modulators Typical room - phone, TV, ethernet
Better … Home office - phone, TV, Media center - phone, satellite receiver, AV modulators Typical room - phone, TV
Good ...
Compatible
screws thread fast and securely.
Bottom knockout accepts standard J-box.
3 RG-6
3 Cat-5
2 RG-6
2 Cat-5
2 RG-6
1 Cat-5
Home Office
he
m t
o
s fr
e
r
wi
ese
h
n
Ru
)
.
r
l
r
o
do
t
n
o
r
f
for
s
l
e
n
n
a
V h
T
ew
V a
o A
r
,
m
d
o
m
le
h cab
te is
i
l
-
G
R
n s.
i
l
e
h e 6
ep on
l
te
o 4
1 t
r
4
(
UTP
-
4
,
-5
t
t Ca
n
e
i m
se
s
e
y
t
w p
T o
i g.)
r
wi
n
u
r
e n
hom
y
l
t
c
re
i
e d
s
ou
h
e
h
t
f
o
s
o
o
r
s
u
3 RG-6
3 Cat-5
3 RG-6
2 Cat-5
3 RG-6
1 Cat-5
Media Center
d.
t
a e
h mes
sc
wir
-
ive
ce
e
te
i
l
t l
a
n
s
e
t
a
e
cr
r
o
t
t l
a
), s
l
e e d , e
b
ca
r
t
a a o
d
le
and
a
t
r
te
en
d
n
a n :
n
s ‘
n a
w
is o
s
i
rio
a
the v
m
o
r
f
2 RG-6
2 Cat-5
1 RG-6
2 Cat-5
1 RG-6
1 Cat-5
Typical Room
in ic
oo
r
e
r
g e e . t
in p
l w
o
l
fo
a s
r
o
R
a VC
ula
d
V mo
A
nna o
e
t
n
a
(
n
o
h
wir
)
s
r
PT wi
atio
c
i
n
ommu
c
o .(Th
ti
a n kn
c
lo
r
n
u
r
s
e m
u
o
H
n
e
Best
Better
Good
e
h
o t
t
e ter
c
e n ms d
e
h
nd t
omme
c
yer,
l
p
V
, D a e r
a D
. (A
ls
a
n
ig
s
r n c
ato
i
v si
e
l
e
t
s
e
l
d
n
a
t d ai
e e s
s
d
e
ld
e
for
d
e use
r
e
t
ce
e n
c
i
p
O
n
n a
i
s
e
bl
Remove rectangular knockout. Drop in J-box and attach with #6 sheet metal screws.
Quick, flexible mounting system
1
i
c
v
r
e
s
e
e r
W
er
m
ca
u
d
o
m
h
x
co
h
s i
Un
re a
i
o w
f
rv
e
h
t
o
t
a
c
e
Th
Install upper right screw.
(#6 - #10)
Center screw on stud.
Place screw 8 1/4” from
desired top of enclosure.
Wiring a house for OpenHouse
Model H318/H336
Service Center Enclosure
ChannelPlus
®
®®
Linear LLC
2055 Corte Del Nogal, Carlsbad, CA 92009, USA
760-438-7000 800-999-5225 fax: 760-931-1340
www.openhousesystem.com
© 2004 Linear LLC, Carlsbad, CA, USA
2
Slide enclosure on screw.
Use screwdriver to select
3/8”, 1/2”, or 5/8” drywall setback.
Tighten screw.
3
Install bottom right side screw.
(Use screwdriver as above to set
the depth of the enclosure.)
Slide enclosure on screw until
screwdriver hits stud.
Warranty
Linear LLC warrants the OpenHouse Model H318/H336 to be free from defects in material and workmanship for 15 years. The time period will be measured using the date code labeled on the product. Linear LLC is not responsible for damage to the product resulting from the buyer's improper handling, stocking or warehousing of the product. Any implied warranty arising from the sale of the product including implied warranties of merchantability and fitness for purpose are limited. Linear LLC shall not be responsible for any losses, damages or expenses, whether direct, consequential, or incidental arising from the use or the inability to use the product. Some states and countries do not allow limitations or how long an implied warranty lasts or the exclusion or limitation or incidental or consequential damages, so the above exclusions may not apply. The Linear LLC warranty gives specific legal rights in addition to other rights, which may exist and vary from state to state and country to country. The warranty is limited to repair or replacement of products returned, freight prepaid, to Linear LLC, there is NO PROVISION FOR LABOR COST OR OTHER REIMBURSEMENTS OF ANY KIND.
1. Failures due to product abuse, such as negligence, improper use, and electrical surge including damage from lightning, water damage or other damage due to natural disasters are not covered by the warranty. The most common form of product abuse is surge damage caused by lightning.
2. The warranty shall also be voided by any tampering with the date code, labels or other markings on the product.
3. Products that are damaged in transit to Linear LLC due to improper packaging or by the carrier (shipping company) will not be covered under the warranty. If the product was damaged or lost by the carrier, it is the sender's responsibility to create a claim against the carrier.
4. The user is responsible for all labor costs associated with removing, reinstalling and returning the product to Linear LLC.
Linear LLC, at its option, will repair or replace the defective product. Replacements will be made from B-Stock, if an exact replacement is not available, Linear LLC, at its option, will select the nearest equivalent product. The user is responsible for freight charges to Linear LLC. Linear LLC will return warranted repaired or replacements by UPS Ground or an equivalent service. A customer may pay the additional costs for second-day or next-day service. All products returned for warranty service require a Return Product Authorization Number (RPA#). Contact Linear Technical Ser vices at 1-800-999-5225 for an RPA# and other important details.
4
Install both left side screws. (Use screwdriver as above to set the depth of the enclosure.) The mount will flex to attach the enclosure to the stud without distorting the enclosure.
Loading...