Linear H293 Owner's Manual

MECHANICAL
Groundedterminal <2inch cub fits into Open House enclosureswithroomfor power supplies Plastic case Fire retardant
The surge suppressor should onlybeused with athree-prongstandardAC outlet. The surge suppressor cannot provide complete protection withoutagroundedAC source.
THE NEED FOR SURGE PROTECTION
TheH293isshown in an H290 8-outlet box used in an OpenHouse structured wire grid system and inapower strip.The surge suppressor can plug into any of the outlets, and will protect all the other units plugged into an H290, H291, the power strip, oraJ­Box.
FOR INDOOR USE ONLY DO NOT:useindampareasor near water.
WARNING: This surge suppressor is NOTa
lightning arrestorand maynot protect against lightning induced voltage surges.
ChannelPlus
AC Surge Suppressor
Power Strip Installation
H290 Installation
OEM
AC ADAPTOR
Part no.: 123-456
U
L
STATUS
LED
Green - Steady
NORMAL-640 joules of protection
Replace Surge Suppressor SOON
Red-Steady
No more protection, REPLACE NOW
640joules 340joules 960joules
Hotto Neutral, peak Hotto Ground, Groundto Neutral, peak To tal, allterminals
Primary +Secondary, Hotto Neutral Secondary only, Hotto Neutral To tal: H-N, H-G, N-G
Maximum power line surge that canbe protected by unit
Maximum surge voltage
Maximum surge dissipation
Specifications
Clamping Vo ltage Maximum voltage allowed across suppressor400 volts
1 nanosecond
6000 volts
Maximum surge current
48,000amps 12,000amps 72,000amps
Response time
Time for clamping to start
Up to 35 dB
100KHz to 200MHz, filters the linetoreduce static andRFinterference
Noise filter reduction
Tested by Underwriters Laboratories to Maximum transientor “let through voltage afterclamping
UL-1449 rating 2nd edition
400 volts
CAUTION
RISKOFELECTRICAL SHOCK, DO
NOT OPEN
!
CAUTION: TO REDUCE THE RISKOF ELECTRICAL SHOCK,DO NOT REMOVE COVEROR BACK.NO USER-SERVICEABLEPARTS INSIDE. REFER SER­VICINGTO QUALIFIED PERSONNEL.
WARNING: To reduce the risk of fireor shock hazard, do not expose thisproductto rain or moisture.
This symbolistoalert youto the presenceof uninsulated dangerous voltage inside the product which could constitute a risk of electric shock.Do not openthe products case.
!
This symbolistoinformyou that important
operatingand maintenance instructionsare
included in the literature for this product.
The H293 bi-level Surge Suppressor
features a unique (patent pending) two-stage, 960 joule surge protection circuit. The first stage provides 640 joules of protection across the hot-to-neutral connection with a response of only one nanosecond before the clamping starts. With ordinary single-stage surge protectors, a surge higher than the rated number of joules, will disable the surge protector leaving the devices near it unprotected. With our surge suppressor, this event will disable only the first stage protection circuit, leaving its devices protected by the second stage. The second stage protection is still 340 joules across the hot-to-neutral connection, making it more than many single state surge protectors.
The H293 protection circuit clamps at 400 volts (UL 1449 rating) and provides protection from surges up to 6,000 volts without being damaged. It also provides protection up to 72,000 amps (48,000 hot to neutral, 12,000 hot to ground and 12,000 neutral to ground) without being damaged. A noise filter helps audio and video devices maintain steady performance by recuding static and RFI on the AC line.
There are built in status lights that indicate exactly how much protection is currently available (see Status Lights below). When a large surge or spike occurs beyond the specified limits, the suppressor should protect the attached equipment, but the primary protection circuit will now be inactive. Even so, in this believe design, there is still partial protection for the equipment that will work against a second large surge. It is advisable that when the lights indicate partial protection (Green - Flashing), the unit should be replaced soon.
The AC electrical lines can experience sudden surges in voltage (up to 6000 volts) from sources outside and inside the home. Outside sources could include industrial equipment being used nearby, while inside sources could be air conditioning units turning on and off, refrigerators and other major appliances. These can damage electronic components, cause loss of data, input/output errors, and computer system crashes. When spikes and surges occur in your home, the surge suppressor will protect your equipment by reducing these voltages to a safe level.
Green - Flashing
First stage gone - 340 joules of protection H-N
ChannelPlus
®
Transient V oltage Surge Suppresso
r
Model H293
OpenHouse Enclosures, Modules,
Accessories&Wall Plates
ChannelPlusmodelH628
DataHub(8 cables,TIA-568A) Category5Compliant
OUT
IN
532-2305MHzto1000MHz
OUTINOUT
IN
OUTINOUT
IN
SPLITTER
COMBINER
R
TelephonesFrom
Telco
ChannelPlusmodelH801
ComboHub(2 line sx6phones,1inpu tx4televisions)
R T
2
R T
1
ChannelPlusmodelH616
TelephoneMasterHub (4linesx 6phones)
Telephones
From Telco
RJ31X
Out
Expansion
Ports
R T
4
R T
3
R T
2
R T
1
Starter systems
RF splitters andtelephonepunch downs. Whenitis time to upgrade, just snapthis module outand replacewithone of more of the more sophisticated units.
Data hubs
Terminationblocks for the CAT-5 cables, Ethernet hubs. Bring the Internet to any room in the home. Or create ahome data network.
Telephone hubs
Connections for 1-4 phone linesto every room. Starter hub addsRJ­31Xjackfor security system dialer.
Coax panels
Distribute antenna or cableTVto every room of the house. Some models include bi-directionalamplifiers forinteractive cable systems. Some models include
IR engines.
modulator
inputs and
AV modulators (for service center)
Create a new TV channelfor afront door camera. Some models feature Cat-5 inputconnections.
TM
Compatible
Service center enclosures
Afull lineof OpenHouse compatible enclosures,from simple,inexpensive mounting plates to high capacity in-wall cabinets. AC outlets canbemounted inside the cabinetsusing aUL listed accessory.
AV modulators (for media center)
Create newTV channels for DVD, VCR, orasatellite receiver.These modulators sitinthe mediacenter.Someoffer true MTS stereo.
®
model 5445 quaddigitalmodulator
pllfrequency control
DCBA
program
select
Wall plates
Wall plate systemsfor allrooms. The typical room getsTV and telephone.The Homeoffice wallplate adds data ports. Themedia center wall plate adds satellite feeds.
IR Accessories
Controlvideo devicesfrom any room.
New products are addedall the time.
Visitour website to learn more:
www.openhouses
y
stems.com
OpenHouse
Typical R oom
Media C enter Home O ffice
Good
Better
Best
1 Cat-5
1 RG-6
1 Cat-5
3 RG-6
1 Cat-5
2 RG-6
2 Cat-5
1 RG-6
2 Cat-5
2 RG-6
2 Cat-5
3 RG-6
3 Cat-5
3 RG-6
2 Cat-5
2 RG-6
3 Cat-5
3 RG-6
Wiring a house f or OpenHouse
Th e cab l es in an O p enHo u se ru n fro m the vario u s rooms o f the hous e
di rectl y t o t he serv i ce ce nter l ocat i on.(T h is is know n a s ‘ ho me ru n ’
wir i n g. ) T wo t y pe s of w ire a re u sed f or c om m u nic a t io n an d
en terta i nment : Cat - 5, 4- UTP ( 4 Unshielded Twisted Pairs) wire handles
da ta o r 1 to 4 t ele p hone l ines. RG-6 coax h andl e s tel e visi o n (an t enna or
ca ble), s at ellit e dis h , cab l e mo d em, o r A V mo d ulato r sig n als. ( An AV
mo dulat o r cre ates n ew TV chan n els f o r front door c amera , DVD play e r, a
VC R o r a satell i te re ceive r.)
We recom m end t h e fo l lowin g pre - wire s chem e s . Run these wire s fro m
th e ser v ice c enter t o t he rooms indi c ated.
Good . ..
Typical room - phone, TV
Media center - p hone, satellite receiver, AV modulators
Home office - phone, T V,
Better …
Typical room - phone, TV, e thernet
Media center - p hone, T V, ethernet, satellite receiver, AV modulators
Home office -
Best …
cable modem
phone, T V, ethernet, cable m odem
Typical room - phone, TV, e thernet, satellite receiver
Media center - p hone, T V, ethernet, s atellite receiver, A V m odulators, h i-speed d ata
Home office - phone, T V, ethernet, satellite receiver, c able modem, hi-speed data
USA & Canada (800) 421-1587 & (800) 392-0123
(760) 438-7000 - Toll Free FAX (800) 468-1340
www.linearcorp.com
Copyright © 2009 Linear LLC 600-232 D
Linear LLC warrants this product to be free from defects in material and workmanship for 2 years. The time period will be
LIMITED WARRANTY STATEMENT
measured using the date code labeled on the product. Linear LLC is not responsible for damage to the product resulting from the buyer’s improper handling, stocking or warehousing of the product. Any implied warranty arising from the sale of the product including implied warranties of merchantability and fitness for pur pose are limited. Linear LLC shall not be responsible for any losses, damages or expenses, whether direct, consequential, or incidental arising from the use or the inability to use the product. Some states and countries do not allow limitations or how long an implied warranty lasts or the exclusion or limitation or incidental or consequential damages, so the above exclusions may not apply. The Linear LLC warranty gives specific legal rights in addition to other rights, which may exist and vary from state to state and country to country.
The warranty is limited to repair or replacement of products returned, freight prepaid, to Linear LLC, there is NO PROVISION FOR LABOR COST OR OTHER REIMBURSEMENTS OF ANY KIND.
1. Failures due to product abuse, such as negligence, improper use, and electrical surge including damage from lightning, water damage or other damage due to natural disasters are not covered by the warranty. The most common form of product abuse is surge damage caused by lightning.
2. The warranty shall also be voided by any tampering with the date code, labels or other markings on the product.
3. Products that are damaged in transit to Linear LLC due to improper packaging or by the carrier (shipping company) will not be covered under the warranty. If the product was damaged or lost by the carrier, it is the sender’s responsibility to create a claim against the carrier.
4. The user is responsible for all labor costs associated with removing, reinstalling and returning the product to Linear LLC.
Linear LLC, at its option, will repair or replace the defective product. Replacements will be made from B-Stock, if an exact replacement is not available, Linear LLC, at its option, will select the nearest equivalent product. The user is responsible for freight charges to Linear LLC. Linear LLC will return warranted repaired or replacements by UPS Ground or an equivalent service. A customer may pay the additional costs for second-day or next-day ser vice.
All products returned for warranty service require a Return Product Authorization Number (RPA#). Contact Linear Technical Services at 1-800-421-1587 for an RPA# and other impor tant details.