Linear 510 Owner's Manual

TRI-GARD 510 AUDIO DETECTOR
The Tri-Gard is a patentedpassive sonic glassbreak detector designed to detect the sound signals produced by the breaking of most types of uncovered glass, including 1/8" and 1/4" plate glass and 1/4" wired glass.
The Tri-Gard features two individual stages of frequency filtering, pro ­viding excellent rejection of audio signals out of the glassbreak spec­trum, and patented signal processing which analyzes all three sound dimensions- “Amplitude” (loudness), “Frequency” (tone, pitch) and the “Rate of Change” of the amplitude and/or frequency .
The maximum range is up to 60 feet from the unit in an open area ­hard acoustical environment. The IEI-510 is self adjusting to compen­sate for background noise and/or rising audio signals.
The TRI-GARD utilizes 3 LED'S to provide a constant visual readout. The green LED indicates power on normal status. The amber LED shows a reading of both amplitude and frequency. The red LED shows an alarm condition. The red LED can either automatically reset or can latch-in requiring the unit to be reset by power interruption. The unit will still detect with the LED on.
TRI-GARD 510 FEA TURES
• Patented state of the art three dimensional signal processing
• Automatic tracking level
• Analysis of the three sound dimensions: amplitude, frequency and rate of rise or rate of change
• 60 ' maximum range
• 3 LED indicators
• Contemporary styling
SPECIFICATIONS
S
ENSING:Audio/air,open space (enclosed area)
R
ANGE: 60 ft. radius
F
REQUENCY SPECTRUM: 4.1KHZ - 16KHZ
AMPLITUDE SPECTRUM: 74DB @ 5KHZ / C SCALE- ADJUSTABLE (MAX) S
ENSING FIELD: Omni-directional
S
ENSOR: Electret condenser (F .E.T .pre-amp)
D
ISCRIMINATION: AMPLITUDE/FREQUENCY/DIST ANCE/RATEOF RISE
SET UP ADJUSTMENTS: SENSITIVITY/ MEMORY LATCH RED LED I
NDICATORS : GREENLED- STATUS NORMAL
RED LED- ALARM CONDITION A
MBER LED- AMPLITUDE AND FREQUENCY
O
PERATINGV
OLTAGE: 10.5–16VDC filtered and regulated
V
OLTAGE
MONITOR: L
OW OR NO VOLTAGE CAUSES ALARM ACTIVA TION
V
OLTAGE
SUPERVISION: A
LARM RELAY
P
OWER CONSUMPTION
: 44 ma @13.6VDC normal, 50 ma max
O
PERATINGTEMPERATURE:14° to120° F. (-10° to 49° C)
R
ELAYACTIVATIONTIME:3 seconds
A
LARM LED: Latch orauto reset
A
LARM RELAY:SPDT (Form-C)- contacts 1Amp @30V AC/24 VDC
T
AMPER
CIRCUIT:Normally closed switch-contacts .1 Amp @ 30VAC/24VDC. I
NSTALLATION
: Hardwire 6 wires including 2 for tamper M
OUNTING:
Surface– screw andanchors included C
OLOR:White or Cabin Brown
S
IZE: 3" x 3" x .79"
WEIGHT: 2.2 OUNCES MOUNTING SCREW: #4 X3/4" SLOTTED PILOT HOLE- SCREW: 1/16" PILOT HOLE- ANCHOR: 3/16"
TRI-GARD510
AUDIO GLASSBREAK DETECTOR
INSTRUCTION BULLETIN
510 # 615-1000
510
MOUNTING LOCA TIONS
The IEI-510 Tri-Gard detection is omni-directional (360°) and should be located as close as possible to the glass being protected. Maintain equal distances from multiple panes. The unit may be wall or ceiling mounted.
NOTE: Do not mount the detector on the same wall as the protected surface. Do not obstruct the detector with partitions or barriers. Do not locate the detector within 30 feet of electro-mechanical bells having a diameter of 1-5" or air compressors which may be activated while the system is in the armed condition.
INST ALLA TION AND WIRING
Run power and alarm loop to unit. Concealed wiring may enter through square hole in base. Surface wire uses notch in case top. The unit may be mounted in any orientation. For wood and some types of ceiling tile, use the screw alone. For metal use screws and drill 1/16" pilot hole. For plaster or drywall use anchors provided with screws.
ALARM LED
Auto reset- Remove JP1 jumper from the pins and reinsert on one
pin only . On alarm the red alarm LED will light for 3 seconds and reset. Latch- To latch the red LED in memory leave JP1 on both pins.
Interrupt power for 5 seconds to reset latched LED.
Note: Alarm relay will reset after 3 seconds.
TESTING/SENSITIVITY ADJUSTMENT
The sensitivity is increased by rotating the potentiometer counter­clockwise. Rotating the potentiometer clockwise will decrease the sen­sitivity . For best results use the IEI-515 glass break simulator and follow the procedure on its label. The tester generates sufficient signal to set the sensitivity as low as possible to prevent nuisance alarms but high enough to detect glass breakage.
NOTE: FINAL TEST WITH THE 515 TESTER MUST BE PERFORMED WITH THE 510 COVER ON.
NOTE: The placement of objects in the room will vary the acoustics. Small displacements of the tester and objects near the 510 can make large differences in the sensitivity setting. This will appear to make the tests inconsistent. Therefore, use this test as a guide for the setting then take into consideration the environment (hard or soft), the dis­tance from the window to the detector and the ambient noise (watch for the yellow led on the 510- it will light if there is too much background noise present). If the tester has the 510 sensitivity set very low, for example, at 30+ foot setting in a living room it is probably a quirk of acoustics and you should set the sensitivity higher . If the yellow led is on frequently during conditions typical to when the alarm system will be armed you may need to reposition the detector and/or lower the sensitivity and add detectors to get the proper coverage.
IEI LimitedWarranty:
Because the manufacturer does not install or connect this security device the manufacturer cannot guarantee its performance. Therefore, there are no warranties, expressed or implied (except as stated below),attached to the sale or use of this product.
The manufacturer warrants against defects in material and workmanship in this device for 3 years from the date of manufacture.During the warranty period the manufacturer ,at its sole option,will repair or replace free of charge any defective unit returned freight pre ­paid. This warranty shall remain in force and ef fect for 3 years provided the unit was prop­erly installed and operated,has not been subject to misuse and has not been rep aired or altered other than by the original manufacturer.
The foregoing states the buyer's sole and exclusive remedy for any breach of warranty or for any claim,whether sounding in contract,tort, strict liability,or negligence,based upon any defect in this security device.
The manufacturer shall in no event be responsible for any incidental or consequential damages incurred by the buyer.
This warranty supercedes all previous warranties.
IEI-510 OPTIMUM LOCATIONS
427 TURNPIKE STREET, CANTON,MA02021 U.S.A. 800-343-9502 OR IN MA 800-733-9502
510 REV. 1.01 615-1000
MADE IN U.S.A.
Loading...