Lincoln Electric TIG 225 Operator’s Manual

Operator’s Manual
PRECISION TIG ® 225
For use with machines having Code Numbers:
11317, 11318, 11319, 11320 Ready­Pak, 11321 Ready-Pak w/Cart
Register your machine:
www.lincolnelectric.com/register
Authorized Service and Distributor Locator:
www.lincolnelectric.com/locator
Save for future reference
Date Purchased
Code: (ex: 10859)
Serial: (ex: U1060512345)
© Lincoln Global, Inc. All Rights Reserved.
i
SAFETY
WARNING
CALIFORNIA PROPOSITION 65 WARNINGS
Diesel engine exhaust and some of its constituents are known to the State of California to cause can­cer, birth defects, and other reproductive harm.
The Above For Diesel Engines
ARC WELDING CAN BE HAZARDOUS. PROTECT YOURSELF AND OTHERS FROM POSSIBLE SERIOUS INJURY OR DEATH. KEEP CHILDREN AWAY. PACEMAKER WEARERS SHOULD CONSULT WITH THEIR DOCTOR BEFORE OPERATING.
Read and understand the following safety highlights. For additional safety information, it is strongly recommended that you purchase a copy of “Safety in Welding & Cutting - ANSI Standard Z49.1” from the American Welding Society, P.O. Box 351040, Miami, Florida 33135 or CSA Standard W117.2-1974. A Free copy of “Arc Welding Safety” booklet E205 is available from the Lincoln Electric Company, 22801 St. Clair Avenue, Cleveland, Ohio 44117-1199.
BE SURE THAT ALL INSTALLATION, OPERATION, MAINTENANCE AND REPAIR PROCEDURES ARE PERFORMED ONLY BY QUALIFIED INDIVIDUALS.
The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm.
The Above For Gasoline Engines
i
FOR ENGINE powered equipment.
1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running.
____________________________________________________
____________________________________________________
____________________________________________________
1.d. Keep all equipment safety guards, covers and devices in
position and tools away from V-belts, gears, fans and all other moving parts when starting, operating or repairing equipment.
____________________________________________________
1.e. In some cases it may be necessary to remove safety guards to guards only when necessary and replace them when the maintenance requiring their removal is complete. Always use the greatest care when working near moving parts.
___________________________________________________
1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors.
1.c. Do not add the fuel near an open flame welding arc Stop the engine and allow it to cool before refueling to prevent spilled fuel from vaporiz­ing on contact with hot engine parts and igniting. Do not spill fuel when filling tank. If fuel is spilled, wipe it up and do not start engine until fumes have been eliminated.
in good repair.Keep hands, hair, clothing and
perform required maintenance. Remove
1.f. Do not put your hands near the engine fan.
Do not idler by pushing on the throttle control rods while the engine is running.
or when the engine is running.
attempt to override the governor or
1.h. To avoid scalding, do not remove the radiator pressure cap when the engine is hot.
ELECTRIC AND MAGNETIC FIELDS may be dangerous
2.a. Electric current flowing through any conductor causes localized Electric and Magnetic Fields (EMF). Welding current creates EMF fields around welding cables and welding machines
2.b. EMF fields may interfere with some pacemakers, and welders having a pacemaker should consult their physician before welding.
2.c. Exposure to EMF fields in welding may have other health effects which are now not known.
2.d. All welders should use the following procedures in order to minimize exposure to EMF fields from the welding circuit:
2.d.1.
Route the electrode and work cables together - Secure them with tape when possible.
2.d.2. Never coil the electrode lead around your body.
2.d.3. Do not place your body between the electrode and
work cables. If the electrode cable is on your right side, the work cable should also be on your right side.
___________________________________________________
1.g. To prevent accidentally starting gasoline engines while turning the work, disconnect the spark plug wires, distributor cap or magneto wire as appropriate.
engine or welding generator during maintenance
2.d.4. Connect the work cable to the workpiece as close as possible to the area being welded.
2.d.5. Do not work next to welding power source.
Mar ʻ95
ii
SAFETY
ii
ELECTRIC SHOCK can kill.
3.a. The electrode and work (or ground) circuits are electrically “hot” when the welder is on. Do not touch these “hot” parts with your bare skin or wet clothing. Wear dry, hole-free
gloves to insulate hands.
3.b. Insulate yourself from work and ground using dry insulation. Make certain the insulation is large enough to cover your full area of physical contact with work and ground.
In addition to the normal safety precautions, if welding must be performed under electrically hazardous conditions (in damp locations or while wearing wet clothing; on metal structures such as floors, gratings or scaffolds; when in cramped positions such as sitting, kneeling or lying, if there is a high risk of unavoidable or accidental contact with the workpiece or ground) use the following equipment:
• Semiautomatic DC Constant Voltage (Wire) Welder.
• DC Manual (Stick) Welder.
• AC Welder with Reduced Voltage Control.
3.c. In semiautomatic or automatic wire welding, the electrode, electrode reel, welding head, nozzle or semiautomatic welding gun are also electrically “hot”.
3.d. Always be sure the work cable makes a good electrical connection with the metal being welded. The connection should be as close as possible to the area being welded.
3.e. Ground the work or metal to be welded to a good electrical (earth) ground.
ARC RAYS can burn.
4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards.
4.b. Use suitable clothing made from durable flame-resistant material to protect your skin and that of your helpers from the arc rays.
4.c. Protect other nearby personnel with suitable, non-flammable screening and/or warn them not to watch the arc nor expose themselves to the arc rays or to hot spatter or metal.
FUMES AND GASES can be dangerous.
5.a. Welding may produce fumes and gases hazardous to health. Avoid breathing these fumes and gases. When welding, keep your head out of the fume. Use enough ventilation and/or exhaust at the arc to keep
fumes and gases away from the breathing zone. When
welding with electrodes which require special ventilation such as stainless or hard facing (see instructions on container or MSDS) or on lead or cadmium plated steel and other metals or coatings which produce highly toxic fumes, keep exposure as low as possible and below Threshold Limit Values (TLV) using local exhaust or mechanical ventilation. In confined spaces or in some circumstances, outdoors, a respirator may be required. Additional precautions are also required when welding on galvanized steel.
3.f.
Maintain the electrode holder, work clamp, welding cable and welding machine in good, safe operating condition. Replace damaged insulation.
3.g. Never dip the electrode in water for cooling.
3.h. Never simultaneously touch electrically “hot” parts of electrode holders connected to two welders because voltage between the two can be the total of the open circuit voltage of both welders.
3.i. When working above floor level, use a safety belt to protect yourself from a fall should you get a shock.
3.j. Also see Items 6.c. and 8.
5. b. The operation of welding fume control equipment is affected by various factors including proper use and positioning of the equipment, maintenance of the equipment and the spe­cific welding procedure and application involved. Worker exposure level should be checked upon installation and periodically thereafter to be certain it is within applicable OSHA PEL and ACGIH TLV limits.
5.c.
Do not weld in locations near chlorinated hydrocarbon coming from degreasing, cleaning or spraying operations. The heat and rays of the arc can react with solvent vapors form phosgene, a highly toxic gas, and other irritating prod­ucts.
5.d. Shielding gases used for arc welding can displace air and
cause injury or death. Always use enough ventilation, especially in confined areas, to insure breathing air is safe.
5.e. Read and understand the manufacturerʼs instructions for this
equipment and the consumables to be used, including the material safety data sheet (MSDS) and follow your employerʼs safety practices. MSDS forms are available from your welding distributor or from the manufacturer.
5.f. Also see item 1.b.
vapors
AUG 06
to
iii
SAFETY
iii
WELDING and CUTTING SPARKS can cause fire or explosion.
6.a.
Remove fire hazards from the welding area.
If this is not possible, cover them to prevent
Remember that welding sparks and hot materials from welding can easily go through small cracks and openings to adjacent areas. Avoid welding near hydraulic lines. Have a fire extinguisher readily available.
6.b. Where compressed gases are to be used at the job site, special precautions should be used to prevent hazardous situations. Refer to “Safety in Welding and Cutting” (ANSI Standard Z49.1) and the operating information for the equipment being used.
6.c. When not welding, make certain no part of the electrode circuit is touching the work or ground. Accidental contact can cause overheating and create a fire hazard.
6.d. Do not heat, cut or weld tanks, drums or containers until the proper steps have been taken to insure that such procedures will not cause flammable or toxic vapors from substances inside. They can cause an explosion even been “cleaned”. For information, purchase “Recommended Safe Practices for the Containers and Piping That Have Held Hazardous Substances”, AWS F4.1 from the American Welding Society
(see address above).
6.e. Vent hollow castings or containers before heating, cutting or welding. They may explode.
Sparks and spatter are thrown from the welding arc. Wear oil
6.f. free protective garments such as leather gloves, heavy shirt, cuffless trousers, high shoes and a cap over your hair. Wear ear plugs when welding out of position or in confined places. Always wear safety glasses with side shields when in a welding area.
6.g. Connect the work cable to the work as close to the welding area as practical. Work cables connected to the building framework or other locations away from the welding area increase the possibility of the welding current passing through lifting chains, crane cables or other alternate cir­cuits. This can create fire hazards or overheat lifting chains or cables until they fail.
6.h. Also see item 1.c.
the welding sparks from starting a fire.
though
they have
Preparation
for Welding and Cutting of
CYLINDER may explode if damaged.
7.a.Use only compressed gas cylinders containing the correct shielding gas for the process used and properly operating regulators designed for the gas and
pressure used. All hoses, fittings, etc. should be suitable for the application and maintained in good condition.
7.b. Always keep cylinders in an upright position securely chained to an undercarriage or fixed support.
7.c. Cylinders should be located:
• Away from areas where they may be struck or subjected to
physical damage.
• A safe distance from arc welding or cutting operations and
any other source of heat, sparks, or flame.
7.d. Never allow the electrode, electrode holder or any other electrically “hot” parts to touch a cylinder.
7.e. Keep your head and face away from the cylinder valve outlet when opening the cylinder valve.
7.f. Valve protection caps should always be in place and hand tight except when the cylinder is in use or connected for use.
7.g. Read and follow the instructions on compressed gas cylinders, associated equipment, and CGA publication P-l, “Precautions for Safe Handling of Compressed Gases in Cylinders,” available from the Compressed Gas Association 1235 Jefferson Davis Highway, Arlington, VA 22202.
FOR ELECTRICALLY powered equipment.
8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment.
8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturerʼs recommendations.
8.c. Ground the equipment in accordance with the U.S. National Electrical Code and the manufacturerʼs recommendations.
6.I. Read and follow NFPA 51B “ Standard for Fire Prevention During Welding, Cutting and Other Hot Work”, available from NFPA, 1 Batterymarch Park,PO box 9101, Quincy, Ma 022690-9101.
6.j. Do not use a welding power source for pipe thawing.
Jan, 07
iv
SAFETY
iv
PRÉCAUTIONS DE SÛRETÉ
Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv­antes:
Sûreté Pour Soudage A LʼArc
1. Protegez-vous contre la secousse électrique:
a. Les circuits à lʼélectrode et à la piéce sont sous tension
quand la machine à souder est en marche. Eviter toujours tout contact entre les parties sous tension et la peau nue ou les vétements mouillés. Porter des gants secs et sans trous pour isoler les mains.
b. Faire trés attention de bien sʼisoler de la masse quand on
soude dans des endroits humides, ou sur un plancher metallique ou des grilles metalliques, principalement dans les positions assis ou couché pour lesquelles une grande partie du corps peut être en contact avec la masse.
c. Maintenir le porte-électrode, la pince de masse, le câble
de soudage et la machine à souder en bon et sûr état defonctionnement.
d.Ne jamais plonger le porte-électrode dans lʼeau pour le
refroidir.
e. Ne jamais toucher simultanément les parties sous tension
des porte-électrodes connectés à deux machines à souder parce que la tension entre les deux pinces peut être le total de la tension à vide des deux machines.
f. Si on utilise la machine à souder comme une source de
courant pour soudage semi-automatique, ces precautions pour le porte-électrode sʼapplicuent aussi au pistolet de soudage.
2. Dans le cas de travail au dessus du niveau du sol, se protéger contre les chutes dans le cas ou on recoit un choc. Ne jamais enrouler le câble-électrode autour de nʼimporte quelle partie du corps.
5. Toujours porter des lunettes de sécurité dans la zone de soudage. Utiliser des lunettes avec écrans lateraux dans les zones où lʼon pique le laitier.
6. Eloigner les matériaux inflammables ou les recouvrir afin de prévenir tout risque dʼincendie dû aux étincelles.
7. Quand on ne soude pas, poser la pince à une endroit isolé de la masse. Un court-circuit accidental peut provoquer un échauffement et un risque dʼincendie.
8. Sʼassurer que la masse est connectée le plus prés possible de la zone de travail quʼil est pratique de le faire. Si on place la masse sur la charpente de la construction ou dʼautres endroits éloignés de la zone de travail, on augmente le risque de voir passer le courant de soudage par les chaines de lev­age, câbles de grue, ou autres circuits. Cela peut provoquer des risques dʼincendie ou dʼechauffement des chaines et des câbles jusquʼà ce quʼils se rompent.
9. Assurer une ventilation suffisante dans la zone de soudage. Ceci est particuliérement important pour le soudage de tôles galvanisées plombées, ou cadmiées ou tout autre métal qui produit des fumeés toxiques.
10. Ne pas souder en présence de vapeurs de chlore provenant dʼopérations de dégraissage, nettoyage ou pistolage. La chaleur ou les rayons de lʼarc peuvent réagir avec les vapeurs du solvant pour produire du phosgéne (gas fortement toxique) ou autres produits irritants.
11. Pour obtenir de plus amples renseignements sur la sûreté, voir le code “Code for safety in welding and cutting” CSA Standard W 117.2-1974.
PRÉCAUTIONS DE SÛRETÉ POUR
3. Un coup dʼarc peut être plus sévère quʼun coup de soliel, donc:
a. Utiliser un bon masque avec un verre filtrant approprié
ainsi quʼun verre blanc afin de se protéger les yeux du ray­onnement de lʼarc et des projections quand on soude ou quand on regarde lʼarc.
b. Porter des vêtements convenables afin de protéger la
peau de soudeur et des aides contre le rayonnement de lʻarc.
c. Protéger lʼautre personnel travaillant à proximité au
soudage à lʼaide dʼécrans appropriés et non-inflammables.
4. Des gouttes de laitier en fusion sont émises de lʼarc de soudage. Se protéger avec des vêtements de protection libres de lʼhuile, tels que les gants en cuir, chemise épaisse, pan­talons sans revers, et chaussures montantes.
LES MACHINES À SOUDER À TRANSFORMATEUR ET À REDRESSEUR
1. Relier à la terre le chassis du poste conformement au code de lʼélectricité et aux recommendations du fabricant. Le dispositif de montage ou la piece à souder doit être branché à une bonne mise à la terre.
2. Autant que possible, Iʼinstallation et lʼentretien du poste seront effectués par un électricien qualifié.
3. Avant de faires des travaux à lʼinterieur de poste, la debranch­er à lʼinterrupteur à la boite de fusibles.
4. Garder tous les couvercles et dispositifs de sûreté à leur place.
Mar. ʻ93
v
EN 60974-10
SAFETY
v
vi
SAFETY
vi
EN 60974-10:
Thank You
viivii
for selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company product
••• as much pride as we have in bringing this product to you!
The business of The Lincoln Electric Company is manufacturing and selling high quality welding equipment, consumables, and cutting equip­ment. Our challenge is to meet the needs of our customers and to exceed their expectations. On occasion, purchasers may ask Lincoln Electric for advice or information about their use of our products. We respond to our customers based on the best information in our posses­sion at that time. Lincoln Electric is not in a position to warrant or guarantee such advice, and assumes no liability, with respect to such infor­mation or advice. We expressly disclaim any warranty of any kind, including any warranty of fitness for any customerʼs particular purpose, with respect to such information or advice. As a matter of practical consideration, we also cannot assume any responsibility for updating or correcting any such information or advice once it has been given, nor does the provision of information or advice create, expand or alter any warranty with respect to the sale of our products.
Lincoln Electric is a responsive manufacturer, but the selection and use of specific products sold by Lincoln Electric is solely within the control of, and remains the sole responsibility of the customer. Many variables beyond the control of Lincoln Electric affect the results obtained in applying these types of fabrication methods and service requirements.
Subject to Change – This information is accurate to the best of our knowledge at the time of printing. Please refer to www.lincolnelectric.com for any updated information.
CUSTOMER ASSISTANCE POLICY
Please Examine Carton and Equipment For Damage Immediately
When this equipment is shipped, title passes to the purchaser upon receipt by the carrier. Consequently, Claims for material damaged in shipment must be made by the purchaser against the transportation company at the time the shipment is received.
Please record your equipment identification information below for future reference. This information can be found on your machine nameplate.
Product _________________________________________________________________________________
Model Number ___________________________________________________________________________
Code Number or Date Code_________________________________________________________________
Serial Number____________________________________________________________________________
Date Purchased___________________________________________________________________________
Where Purchased_________________________________________________________________________
Whenever you request replacement parts or information on this equipment, always supply the information you have recorded above. The code number is especially important when identifying the correct replacement parts.
On-Line Product Registration
- Register your machine with Lincoln Electric either via fax or over the Internet.
• For faxing: Complete the form on the back of the warranty statement included in the literature packet accompanying this machine and fax the form per the instructions printed on it.
• For On-Line Registration: Go to our
“Product Registration”. Please complete the form and submit your registration.
Read this Operators Manual completely before attempting to use this equipment. Save this manual and keep it handy for quick reference. Pay particular attention to the safety instructions we have provided for your protection. The level of seriousness to be applied to each is explained below:
WEB SITE at www.lincolnelectric.com. Choose “Quick Links” and then
WARNING
This statement appears where the information must be followed exactly to avoid serious personal injury or loss of life.
CAUTION
This statement appears where the information must be followed to avoid minor personal injury or damage to this equipment.
viii
TABLE OF CONTENTS
Page
Installation.......................................................................................................................Section A
Technical Specifications ................................................................................................A-1,A-2
Safety Precautions ...............................................................................................................A-3
Select Suitable Location................................................................................................A-3
Environmental Rating....................................................................................................A-3
Grinding.........................................................................................................................A-3
Stacking ........................................................................................................................A-3
Lifting and Moving .........................................................................................................A-3
Tilting.............................................................................................................................A-3
Machine Grounding and High Frequency Interference Protection .......................................A-4
Input and Grounding Connections ................................................................................A-4
Input Reconnect Procedure ..........................................................................................A-5
Output Connections..............................................................................................................A-5
Connections For Tig (GTAW) Welding..........................................................................A-6
Tig Torch Connections ..................................................................................................A-6
Work Cable Connections ..............................................................................................A-6
Shielding Gas Connection.............................................................................................A-6
Remote Control Connection..........................................................................................A-6
Connections For Stick (SMAW) Welding .............................................................................A-6
Stick Electrode Cable and Work Cable Connection......................................................A-6
________________________________________________________________________________
Operation.........................................................................................................................Section B
Safety Precautions ...............................................................................................................B-1
Graphic Symbols ..................................................................................................................B-1
Product Description ..............................................................................................................B-2
Recommended Processes and Equipment ..........................................................................B-2
Recommended Processes.. ..........................................................................................B-2
Process Limitations ......................................................................................................B-2
Recommended Equipment/Interface.............................................................................B-2
Equipment Limitations...................................................................................................B-2
Welding Capability................................................................................................................B-2
Controls and Settings ...................................................................................................B-3, B-4
Power-Up Sequence ............................................................................................................B-4
Case Rear Components.......................................................................................................B-5
Operating Steps ...................................................................................................................B-6
Welding in TIG Mode ....................................................................................................B-6
Pulse TIG Mode ............................................................................................................B-6
Remote Control Operation ............................................................................................B-7
Benefits of the Precision TIG 225 .................................................................................B-7
Welding in Stick Mode..........................................................................................................B-8
Recommended electrode Amperage Ranges ......................................................................B-9
________________________________________________________________________________
Accessories.....................................................................................................Section C
Standard Equipment Options ................................................................................C-1
Factory Installed Options.......................................................................................C-2
Field Installed Options...........................................................................................C-3
________________________________________________________________________
Maintenance ....................................................................................................Section D
Safety Precautions ................................................................................................D-1
Routine and Periodic Maintenance........................................................................D-1
Spark Gap Adjustment ..........................................................................................D-1
________________________________________________________________________
Troubleshooting..............................................................................................Section E
Safety Precautions.................................................................................................E-1
How to Use Troubleshooting Guide.......................................................................E-1
Troubleshooting ..................................................................................E-2 THRU E-7
________________________________________________________________________
Diagrams .........................................................................................................Section F
Wiring Diagram ......................................................................................................F-1
Dimension Print ...............................................................................................F-2,F-3
________________________________________________________________________
Parts List..................................................................................P-536,P-210,P-66 Series
_______________________________________________________________________
viii
A-1

INSTALLATION

A-1
TECHNICAL SPECIFICATIONS - PRECISION TIG 225 (K2533-1AND K2535-1,-2)
INPUT - SINGLE PHASE ONLY
Standard Voltage
Input Current at Rated Output
Power Factor
Idle Current
208/230/1/60
42A / 39A Effective
and 94A / 85A Maximum
0.62 Min.
OUTPUT RANGE
Output Current
Range
5-230 Amps (AC) 5-230 Amps (DC)
Maximum Open
Circuit Voltage
(STICK AND TIG)
AC OCV: 75 DC OCV: 66
CC (Constant Current)
RATED OUTPUT
Process Duty Cycle**
GTAW
10% Duty Cycle
20% Duty Cycle
100% Duty Cycle
SMAW 10% Duty Cycle 20% Duty Cycle
100% Duty Cycle
**Chart gives max. rated Output Amps @% Duty Cycle (Based on a 10 minute cycle).
(Example; 180A@20% for AC/DC Stick and TIG)
* Inputs and ratings include a 20 amp rated load on the 115vac receptacle.
    
   ! " 
Weld Current*
225A AC/DC 180A AC/DC
90A AC/DC (BAL.)
80A AC (AUTO-BAL.)
225A AC/DC 180A AC/DC
90A AC/DC
#
$
3.0A/2.7A Max.
Type of Output
AC/DC
Weld Voltage (NEMA)
15.7 V AC/DC
15.2 V AC/DC
14.1 V AC/DC
14.0 V AC/DC
29.0 V AC/DC
27.2 V AC/DC
23.4 V AC/DC
%%&
-%& ,%& +%&
  . /
*%& )%& (%&
'%&
 $ $
01 23 / 3/  /  0 3/
 / 01 23/ 3/
#%& %&
%&
)% +% -% % '% )% +% -% #% #'%

1
Output Limits allow for continuous max. rated load on 115vac auxiliary receptacle.
2
Wiring and protection based on the 2005 U.S. National Electric Code.
Use a Super Lag type fuse or circuit breaker with a delay in tripping action.
Models with NEMA 6-50P plug may be used with a 50 amp protected 6-50R receptacle, or with a maximum 70 amp protected 6-50R
receptacle if dedicated for the welder.
PRECISION TIG 225
A-2
INSTALLATION
A-2
TECHNICAL SPECIFICATIONS - CANADIAN (K2533-2), INTERNATIONAL K2534-1)
K2533-2 INPUT (at Rated Output)
Voltage/Phase/Freq.
460/575/1/60
Voltage/Phase/Freq.
380/400-415/1/50/60
N80
Max. OCV.
75 V (AC) 66 V (DC)
Process Duty Cycle**
SMAW
15% 20%
100%
Current
18 A/15 A Effective
42 A/33 A Max.
Power Factor
0.62 Min.
K2534-1 INPUT (at Rated Output)
Current
21 A/20 A Effective
50 A/48 A Max.
Power Factor
0.62 Min.
OUTPUT RANGE
Weld Current
5-230 A (AC)
5-230 A (DC)
RATED OUTPUT
Weld Current*
225 A AC/DC
180 A AC/DC
90 A AC/DC
Idle Current
1.3 A/1.0 A Max.
Idle Current
1.5 A/1.4 A Max.
Output Type
CC (Constant Current)
AC or DC
Weld Voltage (NEMA)
29.0 V
27.2 V
23.4 V
GTAW
10% 20%
100%
225 A AC/DC
180 A AC/DC
90 A AC/DC (Bal.)
80 A AC (Auto-Bal.)
* Inputs and ratings include a 6 amp rated load on the 115vac receptacle. ** Based on a 10 minute cycle.
PHYSICAL DIMENSIONS
MODEL HEIGHT WIDTH DEPTH WEIGHT
Machine Only
(K2533-1,-2)
(K2534-1)
Ready-Pak
(K2535-1)
Ready-PakW/Cart
(K2535-2)
(2)
Dimensions are without Lift Eyebolt and Torch Holder
20.71 in. 526 mm
20.71 in. 526 mm
31.24 in. 794 mm
14.48 in. 368 mm
14.48 in. 368 mm
19.81 in. 503 mm
ENVIRONMENTAL RANGES
Operating Temperature -4°F to 104°F (-20°C to 40°C) Storage Temperature -40°F to 185°F (-40°C to 85°C)
(2)
25.62 in. 751 mm
25.62 in. 651 mm
38.01 in. 966 mm
15.7 V
15.2 V
14.1 V
14.0 v
Approx. 192 lbs.
87.1 kgs
Approx. 212lbs..
96.2 kgs.
Approx. 258lbs.
117.0 kgs.
PRECISION TIG 225
A-3
INSTALLATION

SAFETY PRECAUTIONS

Read entire installation section before starting installation.
WARNING
A-3
To install; remove the plug button from the case top and screw the Eyebolt securely into the threaded bracket beneath the case top per the below instruc­tions and warnings provided on the case top decal. Save the removed plug button (LE part No.T10397-2) to cover the hole when the lift Eyebolt is removed.
ELECTRIC SHOCK can kill.
Only qualified personnel should perform this installation.
• Turn the input power OFF at the disconnect switch or fuse box before working on this equipment.
• Do not touch electrically hot parts.
• Always connect the PRECISION TIG 225 to a power supply grounded per the National Electrical Code and any local codes.
---------------------------------------------------------------------------
SELECT SUITABLE LOCATION MOUNTING
Environmental Rating
The Precision TIG 225 power source carries an IP21S environmental rating. It may be used in normal indus­trial and commercial environments. Avoid using it in environments which have falling water such as rain.
Read and follow "Electric Shock Warnings" in the Safety section if welding must be performed under electrically hazardous conditions such as welding in wet areas or on or in the workpiece.
• The Precision TIG 225 must be located where there is free circulation of clean air such that air move­ment in and out the back air vents will not be restricted.
• Dirt and dust that can be drawn into the Precision TIG 225 should be kept to a minimum. Failure to observe these precautions can result in excessive operating temperatures and nuisance shutdown.
WARNING
• Use only Lincoln provided T4550-5 1/2-13 x 1.00 eyebolt.
• Fully engage threads and torque eyebolt to 38 ft. lbs.
• Re-torque eyebolt to 38 ft. lbs. before each lift.
• Lift only with equipment of ade­quate lifting capacity.
FALLING • Never lift welder with gas
EQUIPMENT can cylinder attached.
cause injury. •
• Lift only with equipment of adequate lifting capacity.
• Be sure machine is stable when lifting.
------------------------------------------------------------------------
An undercarriage, provided on the Ready-Pak™ w/Cart model, is also available to easily move the the unit. Refer to the Accessories section of this manual.
Do not attempt to lift the power source with an undercarriage attached.
The undercarriage is designed for hand moving only; mechanized movement can lead to personal injury and/or damage to the Precision TIG 225.
TILTING
Each machine must be placed on a secure, level sur­face, either directly or on a recommended undercar­riage. The machine may topple over if this procedure is not followed.
Never lift welder above personnel.
GRINDING
Do not direct grinding particles towards the welder. An abundance of conductive material can cause mainte­nance problems.
STACKING
Precision TIG 225 cannot
be stacked.
LIFTING AND MOVING
The PRECISION TIG 225 models are provided with an Eyebolt used for lifting the unit with a hoist.
PRECISION TIG 225