IM554
K283 DIGITAL WIRE SPEED METER
OPERATORʼS INSTRUCTIONS
Wire Guide
Display Button
The K283 is battery operated and can be operated in
an ambient temperature of 32º to 120ºF (0º to 49ºC).
Storage temperature range is -30º to 120ºF (-34º to
49ºC). A case is provided for storage when the meter
is not in use.
INSTALLATION
Batteries are shipped loose and should be installed per
instructions below.
1. Loosen screws to release cover.
June, 2011
K283 APPLICATION
For accurate control of welding procedures on constant voltage (CV) systems, use Lincolnʼs K283 wire
speed feed meter.
The wire speed feed meter is a hand-held portable unit
that can be placed on .030” to 7/32” (0.89 to 5.6 mm)
diameter automatic or semiautomatic wire to measure
wire feed speed in inches per minute. The unit can be
used on any wire feeder where there is access to the
wire.
DESCRIPTION
When the meter is used, a spring loaded guide keeps
the pickup shaft on the wire to ensure accurate measurements. The speed is shown on a digital readout
and is accurate within ±1% over a normal range of 100
to 600 inches per minute. The pickup shaft and guide
are insulated from the case so the unit can be used
when the wire starts. The meter displays the wire feed
speed continuously and automatically updates reading
very second. The last reading will be displayed for
approximately 2 minutes before unit shuts off automatically.
2. Insert two AA batteries, matching polarity marked on inside of battery cavity.
If the wire speed feed meter is not to be used for several months, remove batteries from the unit to prevent
corrosion.
OPERATION
Open the guide with attached spring handle and place
pickup shaft on wire so that guide traps the electrode
against the shaft. The shaft must be kept square with
the wire for accurate readings. Brace meter against
wire feeder case or something stationary so unit does
not move while reading wire speed.
Push the button on the side of the unit to have the digital display read wire speed in inches per minute.
To measure wire speed feed on the LN-22 and LN-23P
with a S16001-A or S16001-B wire feed cable, push
the sliding tube up on the cable so meter pickup shaft
can be placed on the wire from the wire reel side.
Check that the sliding tube does not rub on the pickup
shaft.
For maximum life, the wire speed feed meter should be
removed from the wire after wire speed has been
determined. Leaving the meter on the electrode continuously can lead to reduced guide life and expose the
meter to mechanical abuse.
TROUBLESHOOTING
A flashing “B” indicates batteries are low and they
should be replaced with four AA alkaline batteries. If
there is not display and if temperature is below 32ºF
(0ºC), warm up unit until display returns. Be certain
that batteries make a good electrical connection with
battery terminals and spring contacts.
PROBLEMS
(SYMPTOMS)
1. Flashing “B” (or total Display)
2. No Display
SOLUTION RECOMMENDED
PROBLEMS
1. Replace batteries.
2. a. Check batteries.
b. If temperature is below 32
(0oC), warm up unit until
display returns.
c. Be certain that batteries make
a good electrical connection
with battery terminals and that
batteries make good contact
with spring contacts inside
meter housing.
COURSE OF ACTION
o
Contact your Local Lincoln Authorized
Field Service Facility for technical
troubleshooting assistance.