Lincoln Electric IM554 User Manual

IM554
RETURN TO MAIN MENU
K283 DIGITAL WIRE SPEED METER
OPERATORʼS INSTRUCTIONS
Wire Guide
Display Button
The K283 is battery operated and can be operated in an ambient temperature of 32º to 120ºF (0º to 49ºC). Storage temperature range is -30º to 120ºF (-34º to 49ºC). A case is provided for storage when the meter is not in use.
INSTALLATION
Batteries are shipped loose and should be installed per instructions below.
1. Loosen screws to release cover.
June, 2011
K283 APPLICATION
For accurate control of welding procedures on con­stant voltage (CV) systems, use Lincolnʼs K283 wire speed feed meter.
The wire speed feed meter is a hand-held portable unit that can be placed on .030” to 7/32” (0.89 to 5.6 mm) diameter automatic or semiautomatic wire to measure wire feed speed in inches per minute. The unit can be used on any wire feeder where there is access to the wire.
DESCRIPTION
When the meter is used, a spring loaded guide keeps the pickup shaft on the wire to ensure accurate mea­surements. The speed is shown on a digital readout and is accurate within ±1% over a normal range of 100 to 600 inches per minute. The pickup shaft and guide are insulated from the case so the unit can be used when the wire starts. The meter displays the wire feed speed continuously and automatically updates reading very second. The last reading will be displayed for approximately 2 minutes before unit shuts off automat­ically.
2. Insert two AA batteries, matching polar­ity marked on inside of battery cavity.
If the wire speed feed meter is not to be used for sev­eral months, remove batteries from the unit to prevent corrosion.
OPERATION
Open the guide with attached spring handle and place pickup shaft on wire so that guide traps the electrode against the shaft. The shaft must be kept square with the wire for accurate readings. Brace meter against wire feeder case or something stationary so unit does not move while reading wire speed.
Push the button on the side of the unit to have the dig­ital display read wire speed in inches per minute.
To measure wire speed feed on the LN-22 and LN-23P with a S16001-A or S16001-B wire feed cable, push the sliding tube up on the cable so meter pickup shaft can be placed on the wire from the wire reel side. Check that the sliding tube does not rub on the pickup shaft.
For maximum life, the wire speed feed meter should be removed from the wire after wire speed has been determined. Leaving the meter on the electrode con­tinuously can lead to reduced guide life and expose the meter to mechanical abuse.
TROUBLESHOOTING
A flashing “B” indicates batteries are low and they should be replaced with four AA alkaline batteries. If there is not display and if temperature is below 32ºF (0ºC), warm up unit until display returns. Be certain that batteries make a good electrical connection with battery terminals and spring contacts.
PROBLEMS
(SYMPTOMS)
1. Flashing “B” (or total Display)
2. No Display
SOLUTION RECOMMENDED
PROBLEMS
1. Replace batteries.
2. a. Check batteries.
b. If temperature is below 32
(0oC), warm up unit until display returns.
c. Be certain that batteries make
a good electrical connection with battery terminals and that batteries make good contact with spring contacts inside meter housing.
COURSE OF ACTION
o
Contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance.
Date of Purchase: Serial Number: Code Number: Model: Where Purchased: