PRODUCT DATA SHEET
TWINDRIVE
TM
TD1
Features:
• Angle footrest 45°± 3°
• Angle headrest 68° ± 3°
• Compatible with HB10 and HB20
• EOP in TD1 280 version
• Toroidal Transformer in TD1 280 and EI core
Transformer in TD1 220
• Duty cycle: 10% ~ 6 min. per hour max. 2 min.
continuous use followed by 18 min. not in use
• Max. speed: 0.58 RPM with max. torque
• Installation dimension: 796 mm length x 90 mm
height x 90 mm width. Installation dimension
on the shaft 581 ± 1 mm
• Colour: Grey plastic on motor
housing RAL 7035, closing
device Grey RAL 7016
• Ambient temperature:
+5°C to +40°C
• Storage and transport
temperature:
-10°C to + 70°C
• Approved according to EN 60335-1
• EMC according to EN55014 -1 / EN55014 - 2
• Low built-in height
• Low noise level
Options:
• Emergency lowering (2 x 9V batteries)
• External Mains cut-off
• Internal mains cut off (only TD1 220)
• 1 extra channels for an extra motor (analogue
systems)
• Up to 2 extra channels for extra motors (only
TD1 280 with memory and Infrared)
• Memory (only TD1 280)
• Memory and Infrared (only TD1 280)
• Black
The TWINDRIVE™ TD1 is a completely new
product, which is part of the Comfort furniture
group and has been produced to supply the
growing demands for motorised systems in the
leisure bed area.
TD1 is characterised by the very low built in
height, which makes it unique in this market
and gives much more free height under the bed
than previous systems for e.g. storage or easy
cleaning access.
Dimension (mm):
Compatible actuators:
Actuators that are compatible with TD1:
LA27
LA31 with fast motor cannot be used in combination with TD1
Always choose LA27 and LA31 without brake otherwise there will it not be enough power in the 2 x 9 Volt batteries
for emergency lowering. In some cases where a standard HB is to run head, foot motor and the external actuator
simultaneous down it can happen that the actuator not will start if a brake is mounted. In the TD1 280 system with
memory and infrared the current cut-off down is not suffi cient to start up the extra actuator if a brake is chosen.
Cable for LA27
The cable used together with LA27 has to ordered separately:
LA27
(0705816)
Cable for LA31
The cable used in combination with LA31 is not possible to choose in the respectable ordering examples for the actuator. To
avoid any confusing write X when stating the cable and specify the cable as 0705825.
LA31
(0705825)
LA31
Mounting instructions:
Mounting instructions for TWINDRIVETM:
Before mounting, both mounting brackets must be pulled out to their outer position by pushing them back.
This gives freedom of movement to the bed bracket.
Mounting is done by pushing the bed bracket into the TD1 unit and thereafter pushing the mounting brackets back again.
IMPORTANT one must be completely sure that the mounting brackets are in place before TD1 is used.
If the TD1 unit is mounted in the bed it will not be able to fall out if it is under load because the spindle nut is designed to
hold it in place.
Dimensions axle distance: